Climate Line Equipment

Similar documents
PATENTED PATENT PENDING PATENTED PATENTED

PATENTED PATENT PENDING PATENTED PATENTED

PATENTED PATENT PENDING PATENTED PATENTED

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

AC1234 PRODUCT RANGE.

BAC 4000a BAC 5000yf

Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651

2004 HVAC. Heating, Ventilation and Air Conditioning - Hummer H2. Fastener Tightening Specifications Specification Application

Fully responsive touch screen command center...

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

AIR CONDITIONNING 95 CODE 002

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Hybrid Conversion Kit Procedure Guide

Mobile Air-Con Service Solution. AC7000 Operation Manual

User manual Flushing device VAS 6337/1a

CERTUS 11 / 12 EVACUATION & REFRIGERANT CHARGING EQUIPMENT FOR FLAMMABLE GASES

ACS product range. robinair.com

ARIAZONE 5001 FAHD R-134a or R-1234yf DATABASE. Automotive Air Conditioning Service Station OPERATOR MANUAL

FULLY AUTOMATIC A/C SERVICE UNIT USE AND INSTRUCTION MANUAL

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Best Practices for Mobile A/C Refrigerant System Service

Automotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Cooling System Equipment

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

208 For more information visit our website at

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Freeze Dry Systems and Accessories

CC Series VACUUM PUMPS

Freeze Dry Systems and Accessories

AC690PRO PART NO OPERATOR GUIDE

AIR CONDITIONING WORKSHOP EQUIPMENT

Ariazone 601HD Refrigerant Recovery&Recycling unit

AIR CONDITIONING WORKSHOP EQUIPMENT

LEAK DETECTION INDUSTRY LEADING SENSITIVITY

IS YOUR WORKSHOP R1234YF READY?

DHR Accessories Requirements. Site Preparation Guide

MicroRay IR-100 NEW. Inspection MicroRay IR-100

COMPUTERIZED UNIT FOR RECOVERY, RECYCLING, VACUUM, CHARGE AND FLUSHING. User s manual ENGLISH

A/C-Service Unit 7KG-MOBIL Art.-No

Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds

Climate Control. The Andrew Page Air Conditioning Service Range. Equipment Consumables Training

Bottle cooler controllers Solutions for static, ventilated and open coolers

Air Conditioning Workshop EquipmEnt 2013 / 2014

Air conditioning. Product special

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

Refrigerant Recovery Unit, Model RRU134

User s manual. SECU smart

The complete approach to the care and management of A/C & refrigeration systems

UV-Leak Detection System R 134a. UV-Lamp 12 Volt / 50 Watt 14/663. Workshop Requirements, Workshop Devices and Working Security.

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

Direct-Q 3, 5, 8 system Direct-Q 3 UV, 5 UV, 8 UV system User manual

Sensistor ISH2000 Hydrogen Leak Detector

Leak testing in the HVACR Industry

Equipment. Application of refrigerants and heat transfer fluids Application of brazing alloys Application of insulation EQUIPMENT

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

1.1 Glossary Operator Safety Regulations General User and Maintenance Warnings KONFORT 700R SERIES USER SAFETY...

SOLUTIONS TO KEEP IT COOL

Ariazone 5001 HFO-1234yf

B -MG0 i gle G Detecti A rm Ma a nstructio. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

RECOVERY/RECYCLE/RECHARGE

WORKSHEET 4-4 (ON-CAR) HFC-134a Recovery

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

A new wave in automated instrument washing. Introducing the new HYDRIM G4 series

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

RLD-H10P Refrigerant Leak Detector

An ISO 9001 : 2008 Certified Company

Freeze Dry Systems and Accessories

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

RLD-H10G Refrigerant Leak Detectors

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

HEATER & AIR CONDITIONING SYSTEM

Model AC Original Instructions. Recover, Recycle, Recharge Machine for R1234yf A/C Systems

A2Z Ozone Inc. Clean Water and Pure Air for ALL around the world! Product Catalog 2014/15

TECHNICAL INFORMATION L / A 1

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

EC 160 CO 2. Incubator

Operating Manual. Model K/ K Recovery/Recycling/Recharging Unit

GreenTronic. for R1234yf (HFO) With built in Refrigerant Analyzer and Nitrogen Test device OPERATING MANUAL. Rev

EcoMaster - Residential Pools up to 40,000 Gallons

Advance Advance+ Preset

A new wave in automated instrument washing and disinfection Introducing the new HYDRIM G4 WD series

portable gas analyser

USER MANUAL AVL DITEST ADS 130D AIRCONDITION DIAGNOSTIC SYSTEM FUTURE SOLUTIONS FOR TODAY. Revision: Firmware version:

R100 Oil-Less Refrigerant Recovery Unit

USING R-134A REFRIGERANT

SAM-MAX Refrigerant Monitors

Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN ZVSHK 1) DVGW 2) for Professionals

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

WHYNTER Eco Pure Air Purifier

Transcription:

Climate Line Equipment WWW.ITALCOMSRL.COM

Fully automatic single-gas station for recovering, recycling, and recharging R1 34 refrigerant. ITA 1000 AUTOMATIC FUNCTIONS: RECOVERY OIL DISCHARGE VACUUM TRACER optional OIL REINTE- GRATION GAS CHARGING STANDARD FEATURES S ERV ICE A LARM : automatically informs the user when the filters require replacement. S IMPL IFIE D REFR IGERANT M ANAGEM ENT: by printing the report at the end of each recharging operation, the residual refrigerant in the bottle can be displayed for refrigerant transaction accounting FLUSH ING SOF TWARE for automatic flushing of series A/C systems. with AEK102- N7. For use GU IDED LEAK TE ST: permits programming a delay time after the vacuum phase to conduct visual inspection for leaks by checking the pressure gauges. DISTRIBU TOR GROUP : built-in, patented unit optimized for top performance and dependability. DATA BASE BASIC for immediate availability of vehicle refrigerant capacity data. USB POR T for software updates. OPTIONS S ANIFLUX (S ANI+): the first sanitizing system integrated in an A/C charging station. SANI FLUSH ING KIT (AEK102- N7): for flushing the A/C system with refrigerant. External bottle and metal adapters included. A/C DIAGNOS IS MODUL E (DIAKIT) : integrated, for all types of A/C systems, featuring printout of diagnosis and problem solution. S TATIC DIAGNOS IS KIT (KIT S TA001.00) for diagnosing A/C systems. AUTOM ATIC T R ACE R KIT ( UV KIT-7) featuring collapsible cartridges for injecting a predetermined quantity of tracer. DATA B AS E A DVANCE D (KIT DB 002.09): integrated database featuring the option of modifying user data.? XK790 B 000000 S TA ND ARD VE RS ION Type of refrigerant R 134a Service procedure Fully automatic or manual Voltage 220-240 V - 50/60 Hz Scale resolution 10 g Oil scale resolution 5 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 92 liter/min capacity, 0.1 mbar vacuum level Sealed compressor 12 cc, high-pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 12 litres, refillable Hoses 3 metres Overall size 55 x 60 x 105 cm Weight 90 kg Thermal printer S tandard equipment Pressure gauges Class 1 Bottle pressure gauge Class 2.5 Display LCD Bottle temperature sensor Integrated Bottle heater Automatic

ITA 750 Automatic single-gas station for recovering, recycling, and recharging R1 34 refrigerant. AUTOMATIC FUNCTIONS: RECOVERY OIL DISCHARGE VACUUM GAS CHARGING STANDARD FEATURES ALARMS : high pressure, full bottle, empty bottle. S E RV ICE A LARM : acoustic and visual, for maintenance and filter replacement request. S IMPL IFIE D R E FR IGE R ANT M ANAGE M E NT (for use with printer): by printing the report at the end of each recharging operation, the residual refrigerant in the bottle can be displayed for refrigerant transaction accounting VAC UUM PUMP : high performance, with acoustic signaling of end of vacuum. D IS TR IBU TOR GROUP : built-in, patented unit optimized for top performance and dependability. SOF TWAR E UPD ATE: via Internet and RS -232 serial port. OPTIONS XK760 B000000 STANDARD VERS ION Type of refrigerant R 134a Service procedure Automatic or manual Voltage 220-240 V - 50/60 Hz Scale resolution 10 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 92 liter/min capacity, 0.1 mbar vacuum level Sealed compressor 12 cc, high-pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 12 litres, refillable Hoses 3 metres Overall size 55 x 60 x 105 cm Weight 90 kg Thermal printer Optional Pressure gauges Class 1 Bottle pressure gauge Class 2.5 Display LE D Bottle temperature sensor Integrated Bottle heater Automatic DATA B AS E B AS IC (KIT DB 001.09): Coded, integrated database for immediate availability of vehicle A/C system refrigerant capacity data. THE RM AL PR INTE R ( S TM 0004): provides a complete report of station operations.

1 The first purification system integrated in an A/C recharging station SANI THE PROBLEM 2 DAMP + COLD + DARK FORMATION OF: BACTERIA + MOLD + ODORS PERSISTENT, ANNOYING ODORS ALLERGENS AND IRRITANTS THE SOLUTION REFRIGERANT RECHARGING SYSTEM COMBINED SYSTEM HOW DOES IT WORK O peration is fully controlled by the A/C charging station Fully integrated, automatic operation No operator intervention required PASSENGER COMPARTMENT AIR PURIFICATION SYSTEM SANI U ltrasound nebulization of the product Complete service in 30 to 35 minutes Certified purification liquid

OFFERING 4 SERVICE OPTIONS IN A SINGLE A/C STATION Patented Ecotechnics Flushing Kit 2 1 Patented 3 4 diagnosis system incorporated in the recycling stations PATE NT NO.: E P 1177924 US 6,629,420 Diagnosis is an increasingly critical tool for anyone - climate-control specialists and not -wanting to expand their business to include A/C system repair. 2 1 PATE NT PE ND ING ALL THE ADVANTAGES Easy to use F ast, accurate diagnosis of problems P rintout of diagnosis and possible remedial actions R eliability Cost savings, thanks to perfect station integration. 1 Why flush an A/C system? The compressor is a moving mechanical organ, and as such is subject to wear and - in time - to failure. F or correct repair in the case of compressor failure, it is essential to remove any metal shavings that may have accumulated inside the system - and which could jeopardize good operation - before the new compressor is installed. M any compressor manufacturers void their warranties on the new com - ponent if the A/C system is not cleaned, using a suitable flushing system, before the component is installed. Novelties The kit does not use solvents, only refrigerant for flushing. Thanks to the vacuum bottle, the kit guarantees complete, safe removal of all metal shavings. The vacuum in the bottle produces a ramrod effect, forcing the refrigerant through any obstructions in the system. All the Advantages S peeds up the flushing procedure, for considerable time-saving. The operator is free to do other work while the machine flushes the system. Environmentally friendly. F ull automation if used with Ecotechnics stations equipped with dedicated software. M ay be used with other charging stations (in the manual mode). S ince only refrigerant is used, flushing introduces no humidity into the A/C system. S ince no solvents are used, the kit complies with OEM manufacturers standards. S afe and easy to use. Standard equipment Adapters carry-case 5-liter bottle. Optional features M etal support: AEK102- N7-R 2. VW adapter: AEK102- N7-R 1. 2 Static Diagnosis This type of diagnosis utilizes the pressure and temperature values entered by the operator from the station pressure gauges and the thermometer, supplied as standard equipment.? Dynamic Diagnosis W ith the pressure and temperature sensors connected to the system, analysis is fully automatic and conducted in real time for the entire duration of measurement. Sherlock 2000 CLIMA TESTER AEK10 2-N7 AEK10 2-N7-R1 AEK10 2-N7-R 2

Leak Detection Products & Consumables AEK 203 COBR A KIT HD Leak detector kit for A/C circuits including: gog - gles, UV lamp, hermetic dye cartridge (55ml), injector. AEK107-3 EL ECT RON IC LEAK DETECTI ON : a single instru - ment for identi - fying all halogen gases, including CFC, HCFC, HF C AEK1 45-4 COBR A BO TTLE KIT - Leak detec - tion kit for A/C circuits, including: UV lamp, goggles, 6 bottles (7.4 ml each) of tracer, injector, 1 bottle (120 ml) tracer dye cleaner liquid AEK107-6 EL ECT RON IC LEAK DETECT OR for combustible gases (50-1000 ppm) ideal for Nitrogen + Hydrogen mix AEK1 45 Cobra lamp + safety goggles AEK1 47 R echargeable UV lamp 12 V, 50W AEK1 46 Tracer injection gun, including 1 bottle of univer - sal tracer (64 applications), hose and connection for R 134a, high-pressure adapter, air purge connector AEK1 60 AIR FR E SH Deodorant spray B ox of 5 sealed bottles of tracer AEK 203-C-5 (55 ml) AEK1 61 DY E C LEA NE R Liquid detergent for tracer (474 ml) B ox of 6 bottles of AC PO E oil AEK1 25-1- 6 (237 ml) AEK1 26-2 350-ml bottle of universal tracer AEK 204-H-5 B ox of 5 sealed bottles of oil for hybrid vehicles (55 ml) PMP 333 0 Oil for vacuum pump (350 ml) B ox of 6 sealed bottles of tracer AEK1 26-3-6 (125 ml) AEK 222-10 SA NIFLUX L I- QU ID B ox of 10 bottles (125 ml) AEK1 33 Package of 12 vials (7.4 ml each)

WWW.ITALCOMSRL.COM VIA PAGANINI, 7 36022 SAN GIUSEPPE DI CASSOLA (VI) ITALY PHONE +39(0)424.511233 FAX +39(0)424.390197 E-MAIL: INFO@ITALCOMSRL.COM