Climate Line Equipment WWW.ITALCOMSRL.COM
Fully automatic single-gas station for recovering, recycling, and recharging R1 34 refrigerant. ITA 1000 AUTOMATIC FUNCTIONS: RECOVERY OIL DISCHARGE VACUUM TRACER optional OIL REINTE- GRATION GAS CHARGING STANDARD FEATURES S ERV ICE A LARM : automatically informs the user when the filters require replacement. S IMPL IFIE D REFR IGERANT M ANAGEM ENT: by printing the report at the end of each recharging operation, the residual refrigerant in the bottle can be displayed for refrigerant transaction accounting FLUSH ING SOF TWARE for automatic flushing of series A/C systems. with AEK102- N7. For use GU IDED LEAK TE ST: permits programming a delay time after the vacuum phase to conduct visual inspection for leaks by checking the pressure gauges. DISTRIBU TOR GROUP : built-in, patented unit optimized for top performance and dependability. DATA BASE BASIC for immediate availability of vehicle refrigerant capacity data. USB POR T for software updates. OPTIONS S ANIFLUX (S ANI+): the first sanitizing system integrated in an A/C charging station. SANI FLUSH ING KIT (AEK102- N7): for flushing the A/C system with refrigerant. External bottle and metal adapters included. A/C DIAGNOS IS MODUL E (DIAKIT) : integrated, for all types of A/C systems, featuring printout of diagnosis and problem solution. S TATIC DIAGNOS IS KIT (KIT S TA001.00) for diagnosing A/C systems. AUTOM ATIC T R ACE R KIT ( UV KIT-7) featuring collapsible cartridges for injecting a predetermined quantity of tracer. DATA B AS E A DVANCE D (KIT DB 002.09): integrated database featuring the option of modifying user data.? XK790 B 000000 S TA ND ARD VE RS ION Type of refrigerant R 134a Service procedure Fully automatic or manual Voltage 220-240 V - 50/60 Hz Scale resolution 10 g Oil scale resolution 5 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 92 liter/min capacity, 0.1 mbar vacuum level Sealed compressor 12 cc, high-pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 12 litres, refillable Hoses 3 metres Overall size 55 x 60 x 105 cm Weight 90 kg Thermal printer S tandard equipment Pressure gauges Class 1 Bottle pressure gauge Class 2.5 Display LCD Bottle temperature sensor Integrated Bottle heater Automatic
ITA 750 Automatic single-gas station for recovering, recycling, and recharging R1 34 refrigerant. AUTOMATIC FUNCTIONS: RECOVERY OIL DISCHARGE VACUUM GAS CHARGING STANDARD FEATURES ALARMS : high pressure, full bottle, empty bottle. S E RV ICE A LARM : acoustic and visual, for maintenance and filter replacement request. S IMPL IFIE D R E FR IGE R ANT M ANAGE M E NT (for use with printer): by printing the report at the end of each recharging operation, the residual refrigerant in the bottle can be displayed for refrigerant transaction accounting VAC UUM PUMP : high performance, with acoustic signaling of end of vacuum. D IS TR IBU TOR GROUP : built-in, patented unit optimized for top performance and dependability. SOF TWAR E UPD ATE: via Internet and RS -232 serial port. OPTIONS XK760 B000000 STANDARD VERS ION Type of refrigerant R 134a Service procedure Automatic or manual Voltage 220-240 V - 50/60 Hz Scale resolution 10 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 92 liter/min capacity, 0.1 mbar vacuum level Sealed compressor 12 cc, high-pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 12 litres, refillable Hoses 3 metres Overall size 55 x 60 x 105 cm Weight 90 kg Thermal printer Optional Pressure gauges Class 1 Bottle pressure gauge Class 2.5 Display LE D Bottle temperature sensor Integrated Bottle heater Automatic DATA B AS E B AS IC (KIT DB 001.09): Coded, integrated database for immediate availability of vehicle A/C system refrigerant capacity data. THE RM AL PR INTE R ( S TM 0004): provides a complete report of station operations.
1 The first purification system integrated in an A/C recharging station SANI THE PROBLEM 2 DAMP + COLD + DARK FORMATION OF: BACTERIA + MOLD + ODORS PERSISTENT, ANNOYING ODORS ALLERGENS AND IRRITANTS THE SOLUTION REFRIGERANT RECHARGING SYSTEM COMBINED SYSTEM HOW DOES IT WORK O peration is fully controlled by the A/C charging station Fully integrated, automatic operation No operator intervention required PASSENGER COMPARTMENT AIR PURIFICATION SYSTEM SANI U ltrasound nebulization of the product Complete service in 30 to 35 minutes Certified purification liquid
OFFERING 4 SERVICE OPTIONS IN A SINGLE A/C STATION Patented Ecotechnics Flushing Kit 2 1 Patented 3 4 diagnosis system incorporated in the recycling stations PATE NT NO.: E P 1177924 US 6,629,420 Diagnosis is an increasingly critical tool for anyone - climate-control specialists and not -wanting to expand their business to include A/C system repair. 2 1 PATE NT PE ND ING ALL THE ADVANTAGES Easy to use F ast, accurate diagnosis of problems P rintout of diagnosis and possible remedial actions R eliability Cost savings, thanks to perfect station integration. 1 Why flush an A/C system? The compressor is a moving mechanical organ, and as such is subject to wear and - in time - to failure. F or correct repair in the case of compressor failure, it is essential to remove any metal shavings that may have accumulated inside the system - and which could jeopardize good operation - before the new compressor is installed. M any compressor manufacturers void their warranties on the new com - ponent if the A/C system is not cleaned, using a suitable flushing system, before the component is installed. Novelties The kit does not use solvents, only refrigerant for flushing. Thanks to the vacuum bottle, the kit guarantees complete, safe removal of all metal shavings. The vacuum in the bottle produces a ramrod effect, forcing the refrigerant through any obstructions in the system. All the Advantages S peeds up the flushing procedure, for considerable time-saving. The operator is free to do other work while the machine flushes the system. Environmentally friendly. F ull automation if used with Ecotechnics stations equipped with dedicated software. M ay be used with other charging stations (in the manual mode). S ince only refrigerant is used, flushing introduces no humidity into the A/C system. S ince no solvents are used, the kit complies with OEM manufacturers standards. S afe and easy to use. Standard equipment Adapters carry-case 5-liter bottle. Optional features M etal support: AEK102- N7-R 2. VW adapter: AEK102- N7-R 1. 2 Static Diagnosis This type of diagnosis utilizes the pressure and temperature values entered by the operator from the station pressure gauges and the thermometer, supplied as standard equipment.? Dynamic Diagnosis W ith the pressure and temperature sensors connected to the system, analysis is fully automatic and conducted in real time for the entire duration of measurement. Sherlock 2000 CLIMA TESTER AEK10 2-N7 AEK10 2-N7-R1 AEK10 2-N7-R 2
Leak Detection Products & Consumables AEK 203 COBR A KIT HD Leak detector kit for A/C circuits including: gog - gles, UV lamp, hermetic dye cartridge (55ml), injector. AEK107-3 EL ECT RON IC LEAK DETECTI ON : a single instru - ment for identi - fying all halogen gases, including CFC, HCFC, HF C AEK1 45-4 COBR A BO TTLE KIT - Leak detec - tion kit for A/C circuits, including: UV lamp, goggles, 6 bottles (7.4 ml each) of tracer, injector, 1 bottle (120 ml) tracer dye cleaner liquid AEK107-6 EL ECT RON IC LEAK DETECT OR for combustible gases (50-1000 ppm) ideal for Nitrogen + Hydrogen mix AEK1 45 Cobra lamp + safety goggles AEK1 47 R echargeable UV lamp 12 V, 50W AEK1 46 Tracer injection gun, including 1 bottle of univer - sal tracer (64 applications), hose and connection for R 134a, high-pressure adapter, air purge connector AEK1 60 AIR FR E SH Deodorant spray B ox of 5 sealed bottles of tracer AEK 203-C-5 (55 ml) AEK1 61 DY E C LEA NE R Liquid detergent for tracer (474 ml) B ox of 6 bottles of AC PO E oil AEK1 25-1- 6 (237 ml) AEK1 26-2 350-ml bottle of universal tracer AEK 204-H-5 B ox of 5 sealed bottles of oil for hybrid vehicles (55 ml) PMP 333 0 Oil for vacuum pump (350 ml) B ox of 6 sealed bottles of tracer AEK1 26-3-6 (125 ml) AEK 222-10 SA NIFLUX L I- QU ID B ox of 10 bottles (125 ml) AEK1 33 Package of 12 vials (7.4 ml each)
WWW.ITALCOMSRL.COM VIA PAGANINI, 7 36022 SAN GIUSEPPE DI CASSOLA (VI) ITALY PHONE +39(0)424.511233 FAX +39(0)424.390197 E-MAIL: INFO@ITALCOMSRL.COM