RA15/6T & TB Conversion Valve

Similar documents
RA 2000 Series RA 15/6T & TB Conversion Valve

Thermostatic Radiator Valves (Caleffi)

RA2000 Thermostatic Radiator Valves

Radiator Valve Program

CATALOG HD.CAT Danfoss Hydronic Comfort Controls MAKING MODERN LIVING POSSIBLE

RA2000 Commercial TRVs

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Mikrotherm. Manual Radiator Valves With presetting

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

caleffi hydronic valves page 1 of 12

Partner Valve/High Quality Ball Valve LENO MSV-S

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Data sheet Thermostatic sensors type RA 2000

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Temperature controller for steam (PN 25) AVT / VGS - external thread

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Control valves for floor heating systems. Floor Heating Manifolds

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

WAL-RICH CORPORATION SINCE 1950

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

13-1. Temperature Regulator

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Radiator Trap Radiator Valve

Thermostatic valves with radiator connection systems

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Commercial Product Selection Guide

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Multilux 4-Eclipse-Set

Automatic balancing valves ASV-PV (new generation) DN 32-50

Flush individual room control for floor heating systems

SECTION METERS AND GAGES FOR PLUMBING PIPING

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Thermostatic valve bodies

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

ProRadiant Controls, Valves and Actuators

3 years payback time. Millions of reasons to choose the best.

Series 1140 and 1141 Temperature Regulators

Hydronic Separator. Hydro Separator. Hydro Separator. 548 tech brochure Hydro Separator ASME. tech brochure 01076

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Section - A. Radiator Valves

INSTALLATION INSTRUCTIONS

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Pushbutton Switches. Nylon. Specifications. Heavy Duty, Metal Plunger. Specifications S13 S12

Radiator valve inserts

Thermostatic mixing valves with replaceable cartridge for centralized systems

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

2 DESCRIPTION OF SYSTEM COMPONENTS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

V2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS

Say heating. Say Herz. HERZ-Supply Engineering

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

VALVES SECTION 15100

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Domestic Product Selection Guide

ProRadiant Manifolds, Stations and Fittings

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Thermostatic valve bodies

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

HVAC No. MFG Part No. Description Size Price

STEAMPRO. Steam Generator Troubleshooting and Service Guide

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

... Green Building Details

Thermostatic mixing valves with interchangeable cartridges

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Automatic Temperature Controller (ATC)

TIMES SQUARE TWO-HANDLE THERMOSTAT

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Tuzio Milano Towel Warmer

Transcription:

Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from radiators with a heating demand. As a result of decreased supply water temperature, not all radiators will provide the output performance reflected in their catalog resulting in variations in performance when different radiators are combined. The RA15/6TB valve is designed for conventional two pipe systems where each radiator is individually supplied. A traditional supply and return manifold can be utilized when piping the RA15/6TB into the system. The RA15/T and TB is a special conversion valve that allows a single connection point- at the side of the radiator- to serve as both the supply and return for a hot water based system. One such application of the conversion valve is the transition of a cast iron 1-pipe steam radiator to hot water. With the conversion valve the system can be transformed to a conventional one pipe hot water (diverter) or two pipe hot water system. The RA15/6T valve is utilized for one pipe (diverter) systems allowing series piping of radiators without preventing flow to the loop and achieving individual control for each radiator. Within the body of the valve is an internal by-pass allowing system water to With the installation of the RA15/6T and TB valves any RA2000 thermostatic operator or TWA electronic actuator can be mounted, providing individual temperature regulation and controlled comfort for the room. Features: Compact design Minimized installation area Thermostatic operator or electric actuator control of valve Single entry valve connection to radiator Valve assembly for 1-pipe steam conversion to hot water Alternative method of piping for fin tube or baseboard addition Converted 1-pipe steam radiator Fin tube baseboard, system extension Alternative piping for baseboard application, piped as a conventional 2-pipe system 1

Applications (Cont.): Radiator Thermostatic Operators Manifold 24V ac, Electric Actuator RA15/6T piped to a manifold for individual distribution 24Vac, Electric Actuator Fin tube baseboard Thermostatic Operator Alternative piping for baseboard application, piped as a diverter system 2

Ordering Information: Valve Code No. Size Model Cv Connection 013G3270 Rp ½ int. thread 2 RA15/6T 2.34 1 013G3268 ½ G ¾ ext. thread 3 013G3215 RA15/6TB 1.17 Rp ½ int. thread 2 1 Cv = Cv bypass + Cv radiator. Max flow through radiator, approx. 35%. 2 Rp ½ int. thread are straight thread, non-npt thread. 3 G¾ ext. threading require fittings. Fittings and Spare Parts Fittings Code No. Description 013G4116 ½ Copper compression fitting for, 2pcs required, use with 013G3215 & 013G3270 only 013U0476 ½ M. NPT tailpiece for RA15/6T, 2pcs required, use with 013G3268 only 013U8608 ½ F. solder tailpiece for RA15/6T, 2pcs required, use with 013G3268 only 013U0496 ½ Union nut for RA15/6T, 2pcs required, use with 013G3268 only Spare Parts Code No. Description 013G0290 Packing gland 013G5190 Compact Adaptor for Wall Mount Operators. For use only on hot water system. 013G1350 Angle Adapter 3

RA2000 Thermostatic Operator: Operator Code No. Description Sensor Capillary 013G8250 Standard valve mounted dial and sensor Built-in - 013G8252 Standard valve mounted dial with remote sensor Remote 6 013G8240 Tamper resistance valve mounted dial and sensor Built-in - 013G2922 Tamper resistant valve mounted dial with remote sensor Remote 6 013G8562 6 013G8565 Combined remote mounted dial and sensor Built-in 16 013G8568 26 013G8564 Separate remote mounted dial and sensor Remote 6 + 6 Electronic Thermo-wax Actuators: Actuator Code No. Type Operation Actuator Position 088H3110 088H3111 088H3114 TWA-A actuator 24VAC, 2VA c/w valve position indicator ON/OFF NC NO NC, w/ end switch 082F1091 ABNM actuator 24VAC, 1.5VA requires control signal Proportional (0-10VDC) NC 4

Specifications: Suitable applications Max. working pressure Max. differential pressure Max. test pressure Max. flow temperature Connection 1) 1-pipe steam conversion to hot water systems 2) Hot water fin tube or baseboard applications 145 psi (10 bar) 8.7 psi (0.6 bar) 232 psi (16 bar) 248 F (120 C) RA15/6T RA15/6TB Rp ½ int. thread 1 Rp ½ int. thread 1 G ¾ ext. thread 2 1 Rp ½ int. thread are straight thread, non-npt thread 2 G ¾ ext. threading require fittings Design and Function: The RA15/6T and TB valves are a unique design assembly that offer control of radiators or fin tube baseboard through a thermostatic operator or electronic actuator control. The ½ connection to the radiator allows supply hot water to enter and through the same connection allows return water to leave. This circulation through the radiator is achieved through the 8 straight flow tube which is inserted into the radiator. The flow tube receives the return water, while hot water is delivered through the radiator connection. If the length of the radiator is long, the flow tube can be extended by soldering on a ¼ copper tube to the end of the flow tube. The extension to the flow tube results in a pressure drop of 0.02 FOH/in. The extension will allow cooler water furthest from the connection to leave the radiator and be replaced by hot water. Baseboard tubing Supply, thru nipple The valve body is also an ideal alternative in the conversion of a one pipe steam system into a hot water system. In considering the conversion valve for a 1-pipe steam system, verify that across the top of the radiator are push nipples. The push nipples located at the top of the radiator provides circulation for hot water within the radiator. Unfortunately, if the radiator lacks push nipples at the top, the effectiveness of the conversion valve is greatly reduced. Prior to the installation of the conversion valve, the potential 1-pipe steam radiator should be pressure tested to ensure it will be capable of handling the increased pressure from a hot water system. In addition the radiator should also be flushed to remove any debris from within that could potentially clog the valve or other components within the system. The supply and return lines to the valve can be done in copper or PEX tubing. In the event PEX tubing is used with the 013G3268 G ¾ external threaded valve, the PEX compression fittings to be used with the valve should be examined thoroughly to ensure compatibility with the valve. RA15/6TB RA15/6T 5

Construction: Materials in contact with water 1- Pressure pin Pipe supporting bushing PP 2- O-ring gland seal O-ring EPDM 3- Valve cone Valve cone NBR rubber 4- Valve body Pressure pin Chrome steel 5- Flow tube Lock washer Tin alloy Valve body and other metal parts Valve bodies are nickel plated Ms 58 brass 6

Dimensions inches (mm): Typical Specification: The valve shall be nickel plated and capable of delivering supply hot water and receiving return water through a single connection to the radiator. An incorporated flow tube shall receive the return from the radiator and be capable of extending its length. The valve shall be used on a closed loop water based system and have the option of a bypass function. The mountable control for the valve shall have the option of either a non-electric thermostatic operator or a 24V electric actuator. The thermostatic operator shall be available in either a valve or wall mounted dial operator. The valve mounted dial shall be a vapor charged operator and installed via snap-action mechanism or Allen key. The brass valve body shall have a packing gland assembly capable of replacement while the system is in operation. 7

Danfoss can accept no responsibility for possible errors in printed materials and reserves the right to alter its products without notice. All trademarks in this material are property of the respective companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss Inc. Toronto, ON Toll Free: 866-375-HVAC (4822) Tel.: 905-285-2050, Fax: 905-285-2055 www.na.heating.danfoss.com Danfoss Inc. Baltimore, MD Toll Free: 866-375-HVAC (4822) Tel.: 443-512-0266, Fax: 443-512-0270 www.na.heating.danfoss.com 8