Maintaining electrical supply on wood

Similar documents
Think connected. Conducting electricity. Routing data. Controlling energy.

Solutions for the health care sector

TEST REPORT FIRES-FR AUNE

Solutions for airports and railway stations

CLASSIFICATION OF FUNCTION IN FIRE IN ACCORDANCE WITH DIN : with direct field of application FIRES-CR AUPE

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

fischer Fireproof pipe installation Certified fire protection for safe fixings. MLAR MLAR Fire resistance classification R 120 according DIN EN

Compressor Kit for ToughTek F340e Fireproofing Pump

Smoke extraction duct of sheet steel

fischer Fireproof pipe installation Certified fire protection for safe fixings. MLAR MLAR R 30

Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.

onlinecomponents.com 144

COMPONENT SOLUTIONS for the lighting industry

INTERNAL FRAMING PROFILES

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

Zehnder ZIP Radiant Ceiling Panels

Bathroom & accessories

HEINRICH KIPP WERK. Clamping technology Standard elements Operating parts

Ceiling air diffuser INDULTHERM INDULTHERM-e

FV 40.2 Premium Class Glass and dishwashing machine

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Operating Instructions

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

STEGO Products stand for perfect Thermal Management.

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Hexagon nuts Ð Product grade C

PATTERSON FAN MANUAL. Operating, Installation & Parts Manual (OIPM) Patterson Fan Company, Inc Blythewood, SC

CR A-F-A-E-HQQE 3x400/ HZ

Notice. Approval number: Z Scope of validity By: 08 January 2013 to: 01 November 2017

OWNERS MANUAL MODEL: Steamer PART NUMBER: 120 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD.

ZIP Radiant Heating and Cooling Ceiling Panels. Catalog

CONCEALED CEILING SYSTEMS INSTALLATION GUIDE

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

STAND ALONE DRYER BASE. Parts Manual

Hand-drawn curtain rails. wide channel

Modular Drawer Cabinets Installation Instructions

Standard Specification for Hardened Steel Washers [Metric] 1

TP /4-A-F-A-BQQE 400D 50HZ

iq Star LYRA II chilled beam cassette

Catalogue: TEH_02G. Hardware for Sliding Doors (Glass)

Mist eliminators for Flue Gas Desulphurization

Performance Specifications LSF LIFT-SMOKE-FREE

Standard Specification for Hardened Steel Washers [Metric] 1

Catalogue: TEH_02G. Hardware for Sliding Doors (Glass)

1-WAY CEILING CASSETTE FAN COIL UNIT

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

STEGO Products stand for perfect Thermal Management.

CABINET PARTS For Model: KSSS48QJX00 (Stainless Steel)

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

Smoke extract fan SMHA HATCH

CHILLED BEAM CASSETTE IQ STAR LYRA

lindab we simplify construction Lindab Modular air handling units Transport and assembly manual

Warnings, Safety Information and Guidance

Fresh air supply systems

Silent Gliss. Venetian Blind Systems

Installation Manual. Top of Pole Mount Edition v1.01. For models:

Technology for life. Unit heater LH

Global-Tek (Singapore) Pte Ltd

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

MPS-425 e-drum set. assembly instructions

Unistrut Channel and Metal Framing Cable Tray Cable Ladder Cable Basket Pipe and Cable Clamps Electrical and Mechanical Solutions

sunwarm air Application and Installation Guide (for Solar Air Collectors)

AQUAPEUTICS MONACO INSTALLATION MANUAL

Installation Instructions ZUG30 Heater Kit/Cover

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

European Technical Assessment. ETA-14/0028 of 22 September General Part. Technical Assessment Body issuing the European Technical Assessment:

OVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS ELONGATED TWO-PIECE TOILET K-17737T/K-17737T-S

UMA-1020 Light Weight Suspended Ceiling Kit

Industrial Cable Support HALOGEN-FREE - FIRE RETARDANT - OPTICAL FIBER DUCTING

Installation Instructions

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Installation and Operating Instructions

Multipoint Technical Data

AMF Baffles acoustic optimising design elements for the highest requirements. Product description. Features and product properties

ProfiPlus. Open-fronted stackable storage bins smart systems by design

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Leuze electronic. Mounting systems. for optical electronic sensors

Proportioners for Stationary Extinguishing Systems

ACBH/ACBV ACTIVE CHILLED BEAM INSTALLATION MANUAL. Date: 05/12 Reference # : L-50.

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

LINDOFLAMM thermal engineering.

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

iq Star LYRA II chilled beam cassette

Eldon Product Overview

CMA-440 Light Weight Suspended Ceiling Kit

Patterson Fan Manual. Operating, Installation & Parts Manual (OIPM) Patterson Fan Company, Inc Blythewood, SC

Written By: John Bamford

Furring Channel Resilient Mount - Direct Fixing. Ceiling Systems. intex.com.au / intex.co.nz. Intex

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

Fire protection unit


Axial fans The right fan for every house

User Guideline LMD-E 200 LMD-E 200. Hook-On Ceiling Hook-On / Lay-On Type ceiling panels - removable Standard installation.

Premium Cabinet Loudspeakers. Installation manual

BUSINESS PLAN CEN/TC 433 ENTERTAINMENT TECHNOLOGY EXECUTIVE SUMMARY

HELM GT-Hardware for Sliding Doors (Glass and Timber) Sliding hardware

Transcription:

Maintaining electrical supply on wood Cable systems according to DIN 4102 Part 12 Building Connections

Maintaining the supply of electricity when working on sustainable wood In many buildings, the maintenance of the electrical supply in case of fire is mandatory - even in buildings made of wood. If there is a fire, safety-relevant systems, such as emergency lighting and fire alarm systems with supply cables, must continue to function for at least 30 minutes. Fire protection and wooden structures - at first, this sounds like a major contradiction. However, the secure fastening of routing systems on wood is possible with the simultaneous maintenance of the electrical supply according to DIN 4102 Part 12. With a special fastening option on wooden components for our fire protection-tested cable support systems, we at OBO have developed a secure solution for maintaining electrical supply on wood. On the basis of test certificates, standards and evaluations, OBO has had surveyor's comments compiled by an independent engineers' office. The result is that maintaining the supply of electricity when working with unprotected wooden components in fire protection terms is possible without difficulty if specific parameters are taken into account. 2

THE EXPERT from the division for maintaining electrical supply 3

Maintaining electrical supply on wood Its positive properties have led to wood becoming ever more important as a building material. As a renewable resource, wood is sustainable, provides a good atmosphere in the room and is also lighter than reinforced concrete. Fire protection with wooden components is not a contradiction: Although wood as a material is one of the combustible materials, its special properties in case of fire are more beneficial. A layer of charcoal forms on the surface facing the fire, protecting the wood below against oxygen and thus preventing further burning. The remaining unburned residual cross-section in the wooden component can be determined, taking the necessary component dimensions for secure fastening into account. If the wooden component fulfils all the requirements, the type of cable system is specified. OBO offers a product portfolio for maintaining electrical supply, which has been tested and continuously expanded over time. You can find OBO cable systems, which are approved according to general construction testing certificates (AbP), for any application and use them to implement the necessary cable runs in the building. Flange head screw HT 6 Flange head HT 6x60 TD HT 6x80 TD HT 6x100 TD HT 6x120 TD System benefits Self-tapping wood screw for fireproof fastening of cable systems for maintaining the electrical supply according to DIN 4102 Part 12 on supporting wooden structures. The flange head shape allows installation without an additional washer. Flange head screw HT 10 Flange head HT 10x60 TD HT 10x80 TD HT 10x100 TD HT 10x120 TD Safe installation on non-fire-protected wooden components takes place with screws specially approved for connection in wood, for which a proof of use is available in the form of a European Technical Approval (ETA). OBO wood screws are the ideal solution for reliable fastening on wood, guaranteeing the maintenance of electrical supply according to DIN 4102 Part 12. 4 System benefits Self-tapping wood screw for fireproof fastening of cable systems for maintaining the electrical supply according to DIN 4102 Part 12 on supporting wooden structures. The flange head shape allows installation without an additional washer.

Basic information on the subject of wood Suitable wooden elements for the installation of an electrical cable system that maintains the supply of electricity include walls (that close off or do not close off rooms), ceilings and supports made of solid wood. These elements, which are not protected in case of fire, must have verified proof of the used state and, additionally, must be measured for a fire resistance period of 30 or 60 minutes (hot measurement). The surveyor's comments no. GA-2016/034-Mey contain the results of an evaluation by an external engineering office of the possible installations on wooden components. This document describes and documents all the relevant information on the various routing systems. An appropriate general construction test certificate (AbP) is always required as proof for cable systems to be installed. When a so-called "standard support structure" is used, appropriate surveyor's comments are additionally required as proof. Maintaining electrical supply on wood Wooden element Surveyor's comments Cable system according to DIN 4102 Part 12 E30 / E60 Basic calculatory proof on the state of use for solid wood 1 General construction test certificate 2 Surveyor's comments Determination of the carrying capacity of the wooden element in case of fire (hot measurement) F30/F60 Fastening of the cable system with wood screws AbP 1 SC 2 5

Installation options on wooden components Cable route at the side of the beam in a lengthwise direction Cable route under the beam in a lengthwise direction 6

Installation principle Taking the existing building structure and the required cable route in the building into account, different installation options are required on the wooden element. These can be summarised into the following four different groups: Individual cable routing maintaining the electrical function Cable route on the side of the beam in a lengthwise direction Cable route under the beam in a lengthwise direction Cable route vertically on the beam Cable route under the beam in a transverse direction When the basic cable route has been specified, the most suitable installation option can be selected from the available surveyor's comments. The following pages contain some examples of the possible routing systems. Cable route vertically on the beam Cable route under the beam in a transverse direction 7

Cable route under the beam in a lengthwise direction: Installation with clamp clips and profile rail Type Designation 2056 M... Clamp clip CML3518P Profile rail HT 6x...TD Flange head Cable route on the side of the beam in a lengthwise direction: Installation with grouped supports Type Designation 2031 M 15 Grouped support 2031 M 30 Grouped support 2031 M 70 Grouped support HT 6x...TD Flange head Cable route on the side of the beam in a lengthwise direction: Installation with individual clips and FireBox Type Designation 733... Cable and pipe spacer clip T100... FireBox T160... FireBox T350... FireBox HT 6x... TD Flange head 8

Routing of cables that maintains electrical supply on cable trays 9

Cable route at the side on the bar in the lengthwise direction: Installation with cable tray and sloping threaded rod locking Type Designation SKS 6... Cable tray MWA 12... Bracket ABR Connection component ABS Connection component, sloping GLB-P... Fire protection plate HT 10x... TD Flange head Additional accessory parts are required for the system, e.g. connectors and hexagonal nuts. Cable route under the beam in the transverse direction: Installation with standard support structure of a cable tray on a U transverse profile and double-sided suspension with threaded rods Type Designation SKS 6... Cable tray US 3... BSB U support Fire protection clamp 2078 M10 Threaded rod HT 10x... TD Flange head Additional accessory parts are required for the system, e.g. connectors and hexagonal nuts. 05 BSS Funktionserhalt an Holz / en / 07/06/2018 (LLExport_04652) / 07/06/2018 10

Vertical cable routing that maintains electrical supply and is routed in cable routing duct 11

Cable route under the beam in a lengthwise direction: Installation with cable routing duct Type Designation LKM... Cable routing duct HT 6x... TD Flange head Cable route vertically on the beam: Installation with vertical ladder and strain relief Type Designation LG6...VS Vertical ladder 2056 M Clamp clip ZSE90-... Strain relief CML3518P Profile rail KSI-P... Calcium silicate plate HT 6x... TD Flange head Additional accessory parts are required for the system, e.g. connectors. 12

Routing of cables that maintains electrical supply on cable and mesh cable trays 13

Cable route under the beam in a lengthwise direction: Installation with cable tray without additional threaded rod locking Type Designation RKSM 6... Cable tray US 5 K... U suspended support AW 55... Bracket GLB-P... Fire protection plate HT 10x...TD Flange head Additional accessory parts are required for the system, e.g. spacers and hexagonal bolts. Cable route under the beam in the transverse direction: Installation with a mesh cable tray Type Designation GRM 55... Mesh cable tray US 3 K... U suspended support AW G 15... ABG BSB HT 10x... TD Bracket Connection component Fire protection clamp Flange head Additional accessory parts are required for the system, e.g. threaded bolts and hexagonal nuts. 14

15

Depending on the amount of wood burned, from a mechanical point of view, the wood screw is the most critical component in the area of the burned wood. Depending on the routing system, it is not always possible to exploit the maximum permitted mounting parameters of the system. For example, it is necessary to reduce the maximum permitted support distance for a routing system. Furthermore, it may be necessary to install an additional fire protection plate between the routing system component to be fastened and the wooden element. On the one hand, the fire protection plate protects the surface of the wood against the impact of fire. On the other, it distributes the occurring mechanical load over a greater area, meaning that, if there is a fire, the component, e.g. a bracket, is not pushed into the burned wood. All the relevant information on this can be found in the system drawings of the surveyor's comments no. GA- 2016/034-Mey. You can download the comments on secure fastening on wooden elements directly using the QR code or from http://obo.eu/gs_bss. Surveyor's comments 16

Planning checklist The available surveyor's comments describe all the relevant measures and mounting details for secure fastening of our systems on wooden elements. Amongst other things, the contents comprise: Definition of the matching wood screw (length and nominal thickness) for every installation principle Specification of relevant installation parameters such as support and fastening spacings Distinction according to maintaining electrical supply for 30 or 60 minutes Naming of the appropriate proofs for the routing systems as basic proof for maintaining electrical supply 17

OBO support: Help from the fire protection experts Some 40 years of experience in fire protection make OBO a reliable partner. We want to pass on our theoretical and practical knowledge to our customers and have developed a wide range of offers to do this: Personal service: Telephone consultation and e-mail support Field service around the world Fire protection seminars Online offer: Fire protection guide and catalogue Mounting instructions and films Selection aids Certificates OBO Construct app Customer Service Germany +49 (0)2373 89-1700 First consultation, concrete question or a comprehensive problem: Via OBO's Customer Service, you can reach a direct contact who can help you in any matter connected with fire protection. Our technically qualified Customer Service is in constant contact with our product managers and developers and can offer rapid help with practical solutions. In the case of more comprehensive enquiries or tricky challenges, you will be forwarded to the appropriate fire protection expert. Or we can organise a member of our field service to develop solutions with you on site. You can obtain basic knowledge and information on the latest developments in fire protection at our seminars, at which OBO experts and external speakers will share their knowledge with you. 18

"In Customer Service, we do not rely on flyers and catalogues, but give you concrete, solution-orientated advice." Technical support You can find "help to help yourself" on the Internet: Use the OBO Construct app to find out about the suitable sealing systems yourself. In addition, in the download area of www.obo-bettermann.com, you will find all the proofs of use, mounting instructions and selection aids for our fire protection products. International service Fire protection regulations differ from country to country. This is why our fire protection experts are in constant contact with our foreign subsidiary companies. You can also rely on our help in international construction projects. 19

OBO Bettermann Holding GmbH & Co. KG P.O. Box 1120 58694 Menden GERMANY Customer Service Germany Tel.: +49 (0)2373 89-1700 Fax: +49 (0)2373 89-1238 export@obo.de www.obo-bettermann.com