icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

Similar documents
VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

VISTA-50P VISTA-50PUL

RE6100 Series Helix Security and Automation Platform

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

User's Manual VISTA-40 N7003V1 6/97

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

U ser's Guide PC6010

Watchguard WGAP864 User Manual

Contents. Glossary

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Simon XTi Quick Operation Guide

ADEMCO VISTA SERIES User Guide

/10 Rev A

AdvisorOne Quick Operation Guide

User's Manual 5120XM N8031 6/96

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

XRSuper6. User s Guide

AXI LED USER MANUAL (REV. 1.0)

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Lyric Gateway. User Reference Guide. Ref: LCP300-L/LCP300-LC /16 Rev A

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

Tomorrow s technology for today s security needs.

ReadyGuardR-2. Security Systems. User Guide. K /08 Rev. A OFF ARMED READY PLAY ESCAPE VOLUME AWAY 4 5 RECORD TEST ADD STAY LIGHTS ON

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C

LYNXR-2 Series Security System

Safewatch Pro 3000 System Manual

Security System. User s Guide for the Text Command Center

9,67$36HULHV 6HFXULW\6\VWHPV 8VHU*XLGH K5309-1V1 7/02

LYNX Touch L5210 Series Security System

Security System. User Guide for the LED Command Center

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

User s Guide FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA. K5309-5V5 11/08 Rev. A OFF 3 STAY 2 AWAY 1 OFF A B C D 5 TEST 8 CODE 9 CHIME FA260 # FA560

Power864. User s Guide. Now classified in accordance with ANSI/SIA CP (SIA-FAR)

5HDG\*XDUG5 6HFXULW\6\VWHP 8VHU*XLGHIRU5HDG\*XDUG5. K5481-1V2 10/03 Rev. A OFF STAY ESCAPE AWAY ADD DELETE AUX STAY

Independent Zone Control (I.Z.C.)

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

INSTALLATION GUIDE XTLN-WIFI PANEL

XTL/XTLN/XTLN-WiFi USER GUIDE

Control/Communicator Installation Manual

DESTINY OWNER S MANUAL

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

VISTA-20PMT. Security. Systems. User s Guide. Monitronics

Using Your. Security System With LED Keypad S5030, S5031, S5032

XTL Series USER GUIDE

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

LED Keypads D720 Series User s Guide

9,67$ 6(D 6\VWHP 6HFXULW\ 86(5 *8,'( N7229AUV2 12/99

L900 series USER MANUAL

Wireless Security System

SIMPLIFIED HOME SECURITY AND CONTROL

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

Summit 3208GLD USER MANUAL. Electronics Line

NX-148 LCD CODE PAD TABLE OF CONTENTS

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

USING DEVICE COMMANDS

LYNX Touch Security System

Silencing an Alarm All/Perimeter Home/Away Systems Area Systems

ADEMCO LYNX XL SERIES Security System

XRSuper6. User s Guide

XT30/XT50 U S E R G U I D E

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

DSC PowerSeries NEO Quick Start Guide

Installation and Setup Guide

EVO192 v3.0 Fire and Burglary What s New

About Your Security System. General System Operation. Fire Detection. Testing. Monitoring

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

D1265. User's Guide. Touchscreen Keypad

Silencing an Alarm All/Perimeter and Home/Away Systems. Area Systems. What to do when a trouble tone is sounding

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

Contents. Programming Worksheets 22. Appendix A: Guidelines for Locating Smoke Detectors 27. Index 28

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA

Installation Manual RF55O1-433

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

About Your Security System. General System Operation. Fire Detection. Testing. Monitoring

User Guide V3 4/13 Rev. C

Simon XT User Manual R-11 and R-11-CN P/N REV B ISS 13JAN11

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

IDS816 User Manual H Issued January 2009

NetworX NX-8V2. LED Keypad User Manual

System Introduction. 1.1 Specifications

ADEMCO LYNX XL SERIES Security System

First page of this international document resides under separate cover: 20SEaCOV.ps


0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Destiny Destiny Owners Manual

Transcription:

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module. The icontrol Networks, Inc. OpenHome Converge Panel Interface Module (PIM) is a professional state-of-the-art device that allows you to manage your wired system and its sensors from your TouchScreen. 1 Overview The Converge PIM is designed to allow the TouchScreen to takeover an a previously installed wireless system so that its various elements operate as part of the new overall security system. LED Status Condition On solid Description Panel Interface module is in bootup mode. The v2 PIM has 2 possible installation configurations: - Multi Keypad configuration where the PIM is attached to the alarm panel or wall mounted near the alarm panel. In this configuration one PIM supports up to four supported traditional security keypads. No traditional keypad can be left directly connected to the security panel. Maximum of 4 keypads supported. - One PIM per keypad configuration where the PIM is placed in the wall behind each supported traditional security system keypad. In this configuration each keypad requires its own PIM and no traditional keypad can be left directly connected to the security panel. Maximum of 4 keypads supported. Supported sensors are added as zones in TouchScreen of the proper type IF they have been setup correctly in the legacy system 2 Technical Details Physical Dimensions Device Height Width Depth Printed circuit board assembly (PCBA) 1-7/8 in (4.8 cm) 2-3/4 in (7 cm) ½ in (1.3 cm) PCBA in plastic casing 2-5/8 in (6.6 cm) 3-1/2 in (9 cm) 3/4 in (1.9 cm) Voltage: 12VDC (power-limited) Current: 120mA (LED lit) Blinking Off 3 Installation Guidelines Panel Interface module is in locate mode and is ready to be paired with the TouchScreen. Normal operation Important: The PIM must be installed at least 0.3 inches (0.8 cm) away from any metal structure and be used at distances of more than 8 inches (20 cm) away from a location that a user will be standing or sitting for extended periods. The control panel system warranties are voided by the installation of the Panel Interface Module. Note: The TouchScreen can manage up to 31 total ZigBee devices including the PIM(s) added to the system. However, the devices/zones that are managed by the TouchScreen through the PIM do not add to the device-count. For example, IF a) the control panel system is managing 48 zones, and b) the TouchScreen is managing 30 ZigBee devices plus a PIM connected to that keypad/ control panel, THEN the total number of devices managed by the TouchScreen is 79. A. Verify the system is working properly and the zones are programed correctly. B. Identify all the existing/connected Zones are working properly; it is recommended to create a Zone list.

If the Zone numbers are not consecutive, the zone numbering order will be modified when the control panel is taken over by the TouchScreen. For example, if the zones are 1, 3, 5, 6 before activation pairing, they will become 1, 2, 3, 4 after activation pairing. Only the numbering is modified. C. The PIM supports two separate installation configurations: - Multi Keypad configuration (page 2) A single PIM can control a maximum of four keypads - One PIM per keypad configuration (page 3) Up to four PIMs can be installed directly behind four keypads. 5. Install the PIM between the control panel and the keypad as shown in the following figure. Multi Keypad configuration: Perform the following steps AT THE METAL CABINET containing the control panel to install a single PIM that will control up to four keypads. 1. Remove the red and black flying leads from the battery located in the control panel. 2. Remove the A/C power of the control panel by unplugging the AC transformer from the wall outlet. 3. Install the PIM into an aperture on top of the cabinet shown in the figure to the left. Secure the PIM with the nut. Do not install the PIM inside the metal cabinet. 4. Cut the wire that connects the keypad to the control panel. Copyright 2011 icontrol Networks Page 2 The PIM cable labeled To Keypad connects to the cables still connected to the keypads. The PIM cable labed To Panel connects to the cable coming from the control panel. 6. Connect wires based on their colors: red, black, green, and yellow/white. The wire colors identify their functions: Yellow/white Transmit from control panel to keypad Green Transmit from keypad to control panel Red DC power from the control panel to the keypad Black

7. Cover each connection with a wire connector as shown in the following figure: A phone line is no longer needed for the control panel. The TouchScreen uses a Broadband connection as the primary communication path, with GPRS cellular back-up as a secondary path. It is recommended to disconnect the gray 620 cord from the RJ31X jack. 10. Within 90 seconds of applying power to the control panel the PIM(s) are in locate mode and ready to be paired with the Touchscreen. One PIM per keypad configuration Up to four PIMs can be installed directly behind four keypads. One PIM is in direct communication with the TouchScreen (alpha). The rest of the PIMs communicate with the TouchScreen through the alpha PIM. For UL/ETL applications: Do not leave an operational keypad directly connected to the control panel. Doing so renders the control panel inoperable. 8. Reconnect power to the control panel by plugging in the A/C transformer and then re-connect the red and black flying leads to the back-up battery located in the control panel. 9. Within 90 seconds of applying power to the control panel the PIM(s) are in locate mode and ready to be paired with the Touchscreen. If the status LED on the PIM is NOT blinking three times every five seconds, it is possible that the PIM needs to be reset to factory default. The Panel Interface module is installed between the keypad and the control panel. If it is removed from its plastic casing, then it is installed within an industry standard PVC box. This box must be designed and listed for use with non-metallic sheathed cable in accordance with Article 314 of the National Electrical Code. All boxes must be listed to UL514C. This box is not provided as part of the installation kit. It must be provided by the installer. Perform the following steps BEHIND EACH KEYPAD. 1. Remove the red and black flying leads from the battery located in the control panel. 2. Remove the A/C power of the control panel by unplugging the AC transformer from the wall outlet. 3. Cut the wire that connects the keypad to the control panel. Copyright 2011 icontrol Networks Page 3

4. Install the PIM between the control panel and the keypad as shown in the following figure. Connect wires based on their colors: red, black, green, and yellow/white. 5. Cover each connection with a wire connector as shown in the following figure: The wire colors identify their functions: Yellow/white Transmit from control panel to keypad Green Transmit from keypad to control panel Red DC power from the control panel to the keypad Black 6. Reattach the keypad to the mounting surface. 7. Repeat the above steps for each keypad. Remember, one PIM is required for each operational keypad. Do not leave an operational keypad directly connected to the control panel! Doing so renders the control panel inoperable. 8. Reconnect power to the control panel by plugging in the AC transformer and then re-connect the red and black flying leads to the back-up battery located in the control panel. 9. Within 90 seconds of applying power to the control panel the PIM(s) are in locate mode and ready to be paired with the Touchscreen. Copyright 2011 icontrol Networks Page 4

4 Adding a Panel Interface Module Typically the PIM is added to the TouchScreen during the initial Activation as described in the Home Installation Guide. The following procedure is used when a PIM is added after Activation. A. Before beginning this process, record the Zone names assigned to each zone and their zone numbers. B. From the TouchScreen Home screen, tap the Settings app. C. When the TouchScreen Keypad screen appears, enter the Installer keypad code (this code is the same for all TouchScreens installed by your company). D. When the Technician keyboard pad appears, enter your Technician ID and select Done. The Technician Settings menu appears E. Select Home Devices. The Home Devices menu is displayed. F. Tap Panel Interface > Add Panel Interface Boards. The Locating Key Pads screen is displayed. The PIM can be located only within the first 90 seconds of being powered up. If keypad screen should display Scanning for Network. If it displays No Network Found, then press any button on the keypad to restart the process or cycle power to the PIM. Remember that a zone managed by the control panel might have multiple sensors within that zone. When these zones are paired with the TouchScreen, they will be located as a single sensor. For example, a wired zone that has five window sensors (in series) will be managed by the TouchScreen as if it were a single sensor. G. Tap Next. The TouchScreen scans the premises for PIM(s) that can be paired, which must meet the following requirements: - Defaulted - Not currently paired with another TouchScreen - In Search Mode (LED blinking 3 times every 5 seconds) H. Follow the TouchScreen prompts to complete the add process and pair the PIM with the TouchScreen. When the TouchScreen asks that you trip to pair the PIM, press any number on the keypad. If ALL available installed PIMs are not found, select Done to return to the Technician Settings menu without adding. I. When a panel is paired with the TouchScreen, any LEGACY key fobs previously paired with the system are deleted/disabled. They will not be used with new system. J. When all the PIMs are located and paired, select Next. The TouchScreen begins locating the zones connected to the control panel. This operation can take a few minutes. When all the zones are found, an icon is displayed for each zone in the Configure Panel Interface Sensors screen. Note: When zones connected to the control panel are found by the TouchScreen, it automatically configures their functionality (for example, Entry/Exit, Perimeter, etc.) and sensor type (for example, /Window, Motion Detector, etc.) based on various criteria. Section 11 Zone Auto-Configuration describes the mapping of sensors that are auto-configured by the TouchScreen. It is necessary to review the newly added sensors to determine whether they require manual configuration. K. Tap a Zone icon to configure the following: o Display icon (such as a window or door icon) o Zone Function (Entry/Exit, Perimeter, or 24-Hour Inform) o Zone Label (a user-defined identifier for the zone) L. After all the zones are configured, tap Next. Copyright 2011 icontrol Networks Page 5

Additional sensors can be added and managed from the TouchScreen. Additional sensors cannot be added to the control panel after a PIM has been paired with the TouchScreen. Congratulations! You have successfully added your PIMs. Your legacy system keypad can now be used to enter keypad codes to arm/disarm the icontrol OpenHome Converge system as well as turn off zones (bypass zones). Additionally, the legacy keypad information screen displays messages from the icontrol system. 5 Managing the System from the Keypad The following operations can still be performed from the control panel keypad(s): Arm Stay Arm Away Zone Bypass No other keypad features are supported. Panic buttons, On/Off, and Communications Test can no longer be performed from the keypad after the control panel and zones have been paired with the TouchScreen. These functions are now performed from the TouchScreen. Arming the System Zones To use the legacy keypad to Arm the system: A. Enter your 4 digit keypad code plus the desired arming state (below). B. Press Away to arm the system in Arm Away mode (or 2, if there is no dedicated key). Press Stay to arm the system in Arm Stay mode (or 3, if there is no dedicated key). Press Instant to arm the system in Arm Night mode (or 7, if there is no dedicated key). Disarming the System Zones To use the legacy keypad to Disarm the system: A. Enter your user code. B. Press 1 to disarm the system. Bypassing Zones To use the legacy keypad to bypass a zone: A. Enter your user code. B. Press Bypass (or 6, if there is no dedicated bypass key). C. Press the two-digit zone number. 6 Deleting a Panel Interface Module Deleting a PIM removes all associations with the control panel from the TouchScreen. To delete a PIM from the TouchScreen: A. From the TouchScreen Home screen, select the Settings app. B. When the TouchScreen Keypad screen appears, enter the Installer keypad code (this code is the same for all TouchScreens installed by your company). C. When the Technician keyboard pad appears, enter your Technician ID and select Done. The Technician Settings menu is displayed. D. Select Home Devices. The Home Devices menu is displayed. E. Tap Panel Interface > Delete Panel Interface Boards. The Remove Panel Interface Boards and Zones screen is displayed. F. Tap Next. A confirmation dialog is displayed that says Are you sure you want to remove all PIMs and zones? Copyright 2011 icontrol Networks Page 6

G. Tap Yes. The all the PIMs added to the TouchScreen are deleted. Additionally, all zones connected to the control panel are also removed from the icontrol TouchScreen. This process might take up to 15 minutes depending on how many zones are connected to the control panel. The zones that were previously connected to the control panel are still programmed. If a PIM is re-paired with the TouchScreen, it finds the zones just as it did before. 7 Swapping a Panel Interface Module with a New One If a keypad does not respond to system changes (such as, zone status, keypad strokes), there is a possibility that the PIM is defective. If a PIM has been found to be defective, you must swap it out with a functional one. A. Review the zone numbering and the sensors connected through non-functioning control panel. B. Delete all installed PIMs from the system using the procedure Panel Interface from the TouchScreen as described in Section 6, Deleting a Panel Interface Module. C. Power down the control panel: 1. Remove the red and black flying leads from the battery located with the Vista control panel. 2. Remove the AC power. Note: It is important that steps 1 and 2 are performed in this order. D. Install the new PIM as described in Section 3, Installation Guidelines. E. Power up the control panel: 1. Return A/C power and then the red and black flying leads from the battery located in the control panel. 2. Within 2 minutes of applying power to the control panel, the PIM(s) are in search mode and ready to be paired with the Touchscreen. If the LED on a PIM does not blink three times each five seconds, there is a possibility that the PIM must be reset to factory default. See section 4. F. Add the PIM(s) to the TouchScreen as described in Section 4. G. Test the sensors connected through the control panel to ensure the TouchScreen recognizes when they are defaulted and that the connected zones can be bypassed using the keypad. 8 Setting the Panel Interface Module to Factory Default Perform the following steps within 10 minutes of power-up to set the PIM to factory default. Do not press any other keys on the keypad prior to the defaulting process. A. From the legacy keypad, press and hold the [1] and [*] keys at the same time momentarily. The legacy keypad beeps once. Otherwise, repeat this step. For all these steps, it is important to press the keys at the same time. If at any time during this procedure, the keypad beeps twice or chimes, you must disconnect the battery power from the control panel and start this process from the beginning. B. Press and hold the [3] and [#] keys at the same time momentarily. The legacy keypad beeps once. C. Press and hold the [1] and [*] keys at the same time momentarily. The legacy keypad beeps once. D. Press and hold the [3] and [#] keys at the same time momentarily. The legacy keypad beeps once. E. Power cycle the control panel. Copyright 2011 icontrol Networks Page 7

Within 2 minutes of power cycling, a 6160 keypad displays icontrol OpenHome and the LED on the Panel Interface module flashes 3 times every 5 seconds. The keypad displays Scanning For Network. Within approximately 90 seconds, if the PIM has been defaulted, the keypad displays No Network. TouchScreen Reports The TouchScreen will report on troubles communicating with the PIM. 9 Troubleshooting Cannot Turn Off Sounds for a Single Keypad If the Touch Screen is set to play a sound for a zone event, then all the wired keypads will chime for that zone event. If the TouchScreen is set to silent for a zone event, no keypads will chime for that zone event. Incorrect Zone Mapping If a zone is incorrectly configured in the control panel, it might not be correctly configured when added to the TouchScreen. The zone needs to be reconfigured on the TouchScreen after it has been added. Defective PIM If a keypad is unresponsive (either to user input or zone/sensor changes) the PIM is defective. Delete all the PIMs from the TouchScreen and replace it. Add the PIM(s) to the TouchScreen. Cannot pair keypad Unsupported firmware version on the control panel Unsupported keypad Copyright 2011 icontrol Networks Page 8

10 Supported Control Panels Note: See the following subsections for supported devices for the control panels The following Ademco control panels are supported: Vista 15P v3.0 or greater - To verify, open the panel and ensure the chip is labeled WA15Pxx-N.n where N >= 3. Vista 20P v3.0 or greater To verify, open the panel and ensure the chip is labeled WA20Pxxx-N.n where N >= 3. The version of firmware on an control panel cannot be modified. The following DSC control panels are supported: PC1616, PC1832 PC1864 PC580 (Power 432) PC1555 Classic (Power 632) PC1555MX (Power 632) PC5010 (Power832) PC5020 (Power864) Ademco Panels: Supported Keypads The following control panel keypads are supported for both types of Honeywell keypads: Honeywell 6148 Fixed-English Keypad - Supports fixed-english LCD display - 12 keys - 2 status LEDs(Armed and Ready) Honeywell 6150 Keypad - Supports fixed-text display - 16 keys - 2 status LEDs(Armed and Ready) Honeywell 6160 Alpha Display Keypad - Supports 32-character message display - 16 keys, including 4 function keys - 2 status LEDs (Armed and Ready) Honeywell 6160V Talking Alpha Display Keypad - Supports 32-character message display - 16 keys, including 4 function keys - 3 status LEDs (Armed, Ready, and Message) - Record and Playback voice messages are not supported - 6160RF not supported Keypads should say Honeywell on cover; however, they are sometimes re-branded and a decal is placed over the Honeywell logo Copyright 2011 icontrol Networks Page 9

Ademco Vista System: Auxiliary Device Current Draw Worksheet The current draw for the Honeywell Vista 15P and 20P is a maximum of 600mA. Use the following worksheet to calculate the total current draw from the system. If the devices connected to the Vista 15P or 20P exceed the maximum draw threshold, you need to add an auxiliary power supply to the system. Honeywell Vista Auxiliary Device Current Draw Worksheet Device Panel Interface module Hardwired Motion Detectors* 120mA 4219 Zone Expander 30mA 4229 Zone Expander/Relay Unit 100mA Hardwired Glassbreak Detectors* Hardwired Smoke Detectors* 5881/5882 RF Wireless Receiver 60mA 5883 RF Wireless Transceiver 80mA Current 25-30mA* (approx.) 25mA* (approx.) 5mA* (standby) 130mA* (alarm) No. of Devices 6148 Fixed-English Keypad 55mA** NOT SUPPORTED 6150 Keypad 70mA 6150V Keypad 6160 Alpha Display Keypad 150mA ** NOT SUPPORTED 6160V Alpha Display Voice Keypad 190mA ** NOT SUPPORTED 6270 TouchCenter keypad NOT SUPPORTED 8132/8142 Touchscreen keypad NOT SUPPORTED (Current available from Aux. terminals = 600mA max.) TOTAL= TOTAL CURRENT * If using hardwire devices such as smoke detector, glassbreak, and/or motion detectors, refer to the manufacture specifications for that particular unit s current draw. The above current calculations are approximate. ** Values are for devices in alarm; alarm for a keypad means armed with backlighting on and sounder active. DSC Panels: Supported Keypads This section lists the control panels currently supported by the PIM and the supported associated keypads. PC1616, PC1832, PC1864 The following keypads are supported for these DSC panel types: Keypad Type Keypad Type PC5532Z LED PK5500 RFK5500 ICON PK5501 RFK5501 PK5508 RFK5508 PK5516 RFK5516 LCD LED LED PC580 (Power 432) The following keypads are supported for this DSC panel type: Keypad Type Keypad Type Keypad Type LCD5500Z LCD PC5508Z LED PK5500 RFK5500 ICON PC5516Z LED PK5501 RFK5501 LCD PC5532Z LED PK5508 RFK5508 LED PK5516 RFK5516 LED PC1555 Classic (Power 632) The following keypads are supported for this DSC panel type: Keypad Type Keypad Type LCD5500Z LCD PC5508Z LED PC5516Z PC5532Z LED LED Copyright 2011 icontrol Networks Page 10

PC1555MX (Power 632) The following keypads are supported for this DSC panel type: Keypad Type Keypad Type Keypad Type LCD5500Z LCD PC5508Z LED PK5500 RFK5500 ICON LCD5501Z LCD PC5516Z LED PK5501 RFK5501 LCD LCD5501Z32 ICON PC5532Z LED PK5508 RFK5508 LED PK5516 RFK5516 LED PC5010 (Power832) The following keypads are supported for this DSC panel type: Keypad Type Keypad Type Keypad Type LCD5500Z LCD PC5508Z LED PK5500 RFK5500 ICON LCD5501Z LCD PC5516Z LED PK5501 RFK5501 LCD LCD5501Z32 ICON PC5532Z LED PK5508 RFK5508 LED PK5516 RFK5516 LED PC5020 (Power864) The following keypads are supported for this DSC panel type: Keypad Type Keypad Type Keypad Type LCD5500Z LCD PC5508Z LED PK5500 RFK5500 ICON LCD5501Z LCD PC5516Z LED PK5501 RFK5501 LCD LCD5501Z32 ICON PC5532Z LED PK5508 RFK5508 LED PK5516 RFK5516 LED 11 Zone Auto-Configuration During the Locating Sensor step, the TouchScreen identifies the zones monitored by the control panel and maps them as specific sensor types and functionality types. After pairing the sensors with the TouchScreen, ensure that the sensors and zones have been properly mapped. A zone mapping worksheet is available separately. Ademco: Control Panel s Auto-Configured by TouchScreen Code Vista 00 Zone Not Used (bypassed) Ignored 01 02 Entry/Exit Burglary Zone Mapped to TouchScreen Entry/Exit Zone Sensor Type 03 Perimeter Burglary Perimeter Window 04 Interior Follower Interior Follower Motion Detector 05 Trouble by Day/Alarm by Night Provides an instant alarm if faulted when armed in the Away, Stay, Night-Stay, Instant or Maximum (night) modes. During the disarmed state (day), the system will provide a latched trouble sounding from the keypad 06 24-hour Silent Alarm Usually assigned to a zone containing an emergency button. Sends a report to the central station but provides no keypad display or sounding. Entry/Exit Zone Type Panic Copyright 2011 icontrol Networks Page 11

Ademco: Control Panel s Auto-Configured by TouchScreen Ademco: Control Panel s Auto-Configured by TouchScreen Code Vista 07 24-hour Audible Alarm Assign to a zone that has an emergency button. Sends a report to the central station, and provides an alarm sound at the keypad, and an audible external alarm. 08 24-hour Auxiliary Alarm Assign to a zone containing an emergency button, or to a zone containing monitoring devices such as water or temperature sensors. 09 Supervised Fire Provides a fire alarm on short circuit and a trouble condition on open circuit. A fire alarm produces a pulsing bell output. 10 Interior w/delay Provides entry delay if tripped when the panel is armed in the Away mode. 12 Monitor Zone A dynamic monitor of a zone fault/trouble (not alarm). 14 24 Hour Carbon Monoxide Monitor Panic Mapped to TouchScreen Audible 24 Hour Fire 24 Hour Interior Follower Sensor Type 24 Hour Inform Entry/Exit Zone Type Water Sensor Smoke Alarm Motion Detector Code Vista 16 Fire w/verification Provides a fire alarm when zone is shorted, but only after alarm verified. System verifies alarm by resetting zones for 12 seconds after short is detected. A subsequent short circuit within 90 seconds triggers fire alarm. 20 Arm-Stay Arms the system in Stay mode when the zone is activated. 21 Arm-Away Arms the system in Away mode when the zone is activated. 22 Disarm Disarms the system when the zone is activated. 23 No Alarm Response Can be used on a zone when an output relay action is desired, but with no accompanying alarm. Mapped to TouchScreen Fire 24 Hour Entry/Exit Zone Type Entry/Exit Zone Type Entry/Exit Zone Type Entry/Exit Zone Type Sensor Type Smoke Alarm 24 Silent Burglary Entry/Exit Zone 77 Key Switch 81 AAV Monitor 90 91 92 93 Configurable Ignored Copyright 2011 icontrol Networks Page 12

DSC: Control Panel s Auto-Configured by TouchScreen Code Vista Mapped to TouchScreen Sensor Type 00 Zone Not Used (bypassed) Ignored 01 02 03 04 05 06 07 08 09 10 12 14 16 20 21 22 23 24 77 81 90 91 92 93 Copyright 2011 icontrol Networks Page 13

icontrol Networks Model: 4000001604 FCC ID Y6Q-4000001604 IC: 9454A-4000001604 Compliances FCC Notice This device has been designed, constructed, and tested for compliance with FCC Rules that regulate intentional and unintentional radiators. As the user of this device, you are not permitted to make any alterations or modifications to this equipment or to use it in any way that is inconsistent with the information described in this quick-start guide, without the express written permission of SMC Networks. Doing so will void your warranty to operate this equipment. Security products and alarm systems do not offer guaranteed protection against burglary, fire, or other emergencies. They may fail to warn for diverse reasons, including (but not limited to): power failure, dead batteries, improper installation, coverage, coverage areas overlooked during installation, defeat by technically sophisticated intruders, component failure, or inadequate maintenance. Alarm systems should be checked weekly to ensure that all devices are working properly. AN ALARM SYSTEM IS NOT A SUBSTITUTE FOR INSURANCE The exterior of the device should be labeled with the following instructions Zigbee Panel Interface module is integrated with Contains FCC ID: Y6Q-SMCTB01Z and Contains IC ID 9454A- SMCTB01Z. This device complies with Part 15 of the FCC rules. Operation of this device is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. The IC designation preceding the radio certification number indicates that this device complies with the Industry of Canada specifications. Limitations of Security Products Copyright 2011 icontrol Networks Page 14