DTS MOBATime's Distributed Time System

Similar documents
GPS or DCF 77. DTS Masterclock

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

INSTRUCTION MANUAL. Change Over Unit ECO for ETC 24R MOBATIME BE

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM RAMOS Ultra

N-8000 SERIES IP INTERCOM SYSTEM

Alarm module for leak detection with webserver

Security designed for your lifestyle

Panel Mounted Fault Annunciator Series

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Panel Mounted Fault Annunciator Series

Fire alarm system EBL512 G3

IntesisBox BACnet/IP Server - Notifier ID3000 series

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Call stations and extensions

ACTIVE INFRARED BARRIER

Combined CAN Sensor Unit Temperature, Humidity and Smoke

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

IndigoVision Alarm Panel. User Guide

CMC-TC Processing Unit II Assembly, Installation and Operation Manual

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

Window facia fault annunciators

Outdoor Temperature Sensor

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Solution F2. Fire Alarm Control Panels one step ahead.

Galaxy Pulsar Plus Digital Battery Plant Controller

CMC-TC Basic CMC DK

Fire Alarm Network Reference

securityprobe SNMP-based Environmental and Security Monitoring Solution

Dew point set DS 400

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

ME 3011C / Alarm Indication / Quick Reference Guide

DSE ELECTRONIC SIRENS Advantages & Functions

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

TELSEC MINI PRO User Guide

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Elemec3. Networked Public Address and General Alarm System (PA/GA)

SCR100 User Manual. Version:1.1 Date:Dec 2009

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

SC-F3G User Manual 1.0

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

LORAIN CIP 4890/48120 DC Power System

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Analog Annunciator Unit SACO 16 A3. Product Guide

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

CAN unit for Analog Sensors

GAI-Tronics Systems NEW! Elemec3 Digitally Controlled PA and General Alarm system PA/GA

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Universal fault annunciator for panel mounting

SIMATRIX NEO Modular Video Matrix

Typical applications include the vibration detector. Detection of vibrations and shocks

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Intelligent Single Loop Fire Alarm Control Panel

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

CMC- Top Concept A redefinition of rack security

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Danfoss gas detection units

GasGard 100 Control System

APC BC300 Series 40kW 208/450/480V User Guide

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

CMC-TC Processing Unit II DK

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

Solutions for Mass Notification Systems

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

P2267 NETWORK INTERFACE

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Model 135 Reference Document

Labkotec Ice Detector

Didactum Monitoring System 50

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

OVEN INDUSTRIES, INC.

Cold chain monitoring technologies. Facility monitoring

MiNi Server environment MoNitoriNg SySteM

Segment design & and Bus Diagnostics

TrueAlarm Fire Alarm Systems

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Annunciator Unit SACO 16 D1. Product Guide

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

AirFlow Sensor for Dry Contact connection

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Remote fiber testing to improve SLA s

Parameterisable compact fault annunciator with permanent display

Transcription:

Swiss Time Systems GPS or DCF 77 MOBA-NMS (Network Management System) DTS Masterclock DTS MOBATime's Distributed Time System LAN The multipurpose time server in the new LAN and based Distributed Time System by MOBATIME DTS 4135.timeserver The DTS 4135.timeserver sets new standards as a time reference for all clients in medium and large networks (LAN Ethernet/IP/UDP). It is highly precise and with its intelligent concept for redundant operation, it offers a high degree of reliability and availability. The DTS 4135.timeserver can either be synchronized from a time signal receiver (DCF 4500, GPS 4500 or IRIG/AFNOR time source), or from another or S time server in the LAN or Internet. The DTS 4135 can synchronize all slave clocks with movements, either with Multicast or Unicast (both with time zone server function). As a multipurpose device the time server is equipped with two independent IRIG/AFNOR outputs, two serial RS 232/RS 485 interfaces with script file programmable telegrams, two DCF or high accurate pulse /frequency outputs (RS 422 and optocoupler) and one additional DCF current loop output. The highest degree of system availability and reliability can be achieved by the master-slave operation of two DTS 4135.timeservers connected via fiber-optic (redundant operation). Alarms are signaled by alarm relay, SNMP messages or e-mails.

DTS 4135 - the innovative, precise time reference for networked, multifunctional systems Time precision Best accuracy can be achieved by synchronizing the DTS 4135.timeserver via a connected GPS receiver, and thanks to an intelligent time management. The internal time is adjusted to the time reference (e.g. GPS) in one step or slowly shifted (in adjustable micro steps) to avoid any time leaps (e.g. after a longer loss of the time source). To achieve utmost accuracy, the quartz drift and aging is continuously compensated. Front view Connectors: LAN connector RJ 45, 10/100 Mbit PC terminal connector, RS232 Sub-D 9p male USB connector for software update, file download to the DTS 4135 (e.g. telegram files, timezone table, etc.) and maintenance Top performance - even for large networks The high performance DTS 4135 timeserver can reply more than 250 and S requests per second. It can also work as an time reference for a network, being synchronized from a superior -Server (client and server at the same time). authentication Supports authentication for increased security, which allows the clients, to verify the received packets. LEDs: Mains power, alarm, synchronization and network transmission control Display: Time, date, status, alarm, IP, etc. Safe and convenient operation After configuring an IP address via serial interface (terminal program), operation over LAN via MOBA- NMS (SNMP), Telnet, SSH or SNMP protocols is possible. SSH and SNMP (MD5 authentication and DES for encryption) enable a secured connection. Special software is required for operation by SNMP protocol. Effective fault indication Alarms are reported by alarm relay, by e-mail, or via SNMP messages. Additionally, the display can be used to check the alarm state by pressing the red push button. Rear view Connectors: Power: Mains power connector, 2 DC power supply inputs, DC output (e.g. for GPS) Alarm: alarm relay contact, alarm input Synch. inputs: IRIG-B/AFNOR input (BNC), DCF current loop Synch. outputs: DCF current loop, DTS link (GBIC-module) Serial: 2 RS 232/485, both for script file progr. serial message IRIG: 2 IRIG-B/AFNOR outputs (BNC) IRIG DC: 2 DC level IRIG-B/ AFNOR outputs (both RS 422 & optocoupler) Pulses: 2 DCF or pulse/frequency outputs (both RS 422 & optocoupler) DTS device mounted in a 19 IT-Rack

DTS 4135 - the time source for LAN-based clock and time distribution systems The DTS 4135.timeserver is a versatile time reference in several respects. On one hand, it relays the external time signals with maximum precision and reliability. It is compatible with all unicast (IP based) or multicast devices, such as slave clocks with movement (e.g. NBU 190), digital clocks and digital information displays with synchronization. On the other hand, it can also synchronize the NMI (Network Management Interface), which can synchronize master clocks with MOBALine and DCF 77 output. Even PCs/workstations, photocopiers, printers, fax equipment, time recording terminals, access control systems, central fire alarm systems, image and sound recording equipment, and many other kind of clients in the network can be synchronized by means of the network time protocol (). DTS 4135.timeserver MOBA-NMS (Network Management System) DTS 4801.masterclock LAN WAN

DTS 4135 - highest priority for availability and reliability Redundant server operation To avoid time deviation between two DTS 4135.timeservers, they can be linked via a fiber-optic connection by using two GBIC modules. The two time servers automatically negotiate their state as master or slave. The slave is always synchronized by the master. In case of GPS failure, an automatic swap between master and slave state will occur. The parameters for the swap can be configured. The master DTS timeserver always has the better stratum level than the slave. Redundant power The DTS 4135.timeserver has several monitored power inputs for completely redundant power supply. The non-active power supply input is also monitored. Possible power variants: 24 VCD, non-redundant 230 VAC, non-redundant 24 VDC + 24 VDC, redundant 230 VAC + 24 VDC, redundant Redundant outputs Redundant IRIG-B/AFNOR, serial telegram, DCF and/or pulse/frequency outputs can be achieved by an External Change Over unit (ECO). Redundant operation (fiber optic link) Master GBIC modules Slave LAN WAN Redundant power Monitored inputs 90-240 VAC 24 VDC 24 VDC

Swiss SwissTime TimeSystems Systems DTS 4135 - versatile high precision master clock and time server DTS 4135.timeserver as server and master clock for high precision IRIG-B/AFNOR outputs, for RS 232/485 serial messages and technical pulses or frequencies. Central monitoring SNMP, e-mail Redundant Server DTS 413x.timeserver Time signal receiver GPS 4500 DCF 4500 LAN / WAN Services Clients Process controller Voice recording Building automation Audio and image recording RS 232/485 serial outputs Analog and digital clocks IRIG-B/AFNOR/DCF-FSK Computers High precision DCF, Pulse or Frequency outputs Process controller Process controller Building automation Sub-Master Clock DTS 4135, AFNOR syncrhonized The DTS 4135.timeserver features two IRIG-B/AFNOR outputs to synchronize analog and digital slave clocks, process controllers, voice recording systems and many other technical equipment. The DTS 4135.timeserver also features two RS 232/485 serial outputs. Programmable messages with script file allow the synchronization of any kind of technical equipment like e.g. computer server, process controller, fire supervision system, etc. For utmost precision of the synchronization, two high accurate pulse outputs are provided. They can either be used as DCF outputs (RS 422 and optocoupler) or periodical pulses. Typical applications are industries, power distribution stations and power plants, where high reliability, high precision, no time leaps and permanent availability are required.

DTS 4135.timeserver - Technical details Technical Data Time signal outputs DTS Links (Redundancy) -slave clock line Network services Network Interface IP configuration Operation LED indication Display Local time calculation Accuracy Time keeping (internal) DTS 4135 -> TCXO V4 (fully V3 compatible) / S, multicast DCF-time signal output (optocoupler passive) 2 x IRIG-B/AFNOR output, each with analog (BNC) and DC level (RS 422 and optocoupler) output 2 x DCF 77, programmable pulses/frequencies (RS 422 and optocoupler) 2 x RS 232/485 serial message programmable by script file Max. length of the fiberglass cable, e.g. multimode fiber Ø 50 µm: multimode fiber Ø 62.5 µm: For slave clocks synchronization by multicast or unicast (IP based) Time zone server function with up to 15 different time zone entries. client server, max. no. of and S client requests: SNMP V1, V2c, V3 (get, put, notification, trap) with MD5 authentication and DES for encryption E-Mail for alarm messages (2 addresses possible) DATE, TIME, FTP (for update) 10BaseT / 100BaseTX (IEEE 802.3) Data transmission rate: auto-negotiation / manual Connection: RJ45 (only shielded cable permitted) DHCP, static IPv4, IPv6 Serial terminal via RS 232 (front side, sub-d 9p male) Via LAN: MOBA-NMS, Telnet, SSH, SNMP (special software necessary) USB connector for software update, maintenance (config. and log files upload) or file download (e.g. telegram files, etc.) Power supply, synchronization status, LAN status, alarm, DCF input Display for status information: Time, date, IP, alarm, etc. (2 lines with 16 characters) Automatic, preprogrammed daylight saving time change Up to 80 pre-defined time zone entries and 20 user-definable entries All outputs can be individually allocated to a time zone (UTC or local time) GPS (DCF input) to server: GPS (DCF input) to DCF 77 / pulse output: to internal time: Redundant operation: master to slave GPS (DCF input) to IRIG (analog) GPS (DCF input) to IRIG (digital) Internal time to serial outputs (jitter: ± 10 ms) Synchronized with GPS: Hold over (after > 24h synch. from GPS) at 20 C ± 5 C: Hold over (after > 24h synch. from GPS) at constant temperature: After restart without synchronization (for 24h) at 20 C ± 5 C: MOSER-BAER AG Sumiswald/Geneva, Switzerland www.mobatime.com IRIG-B122, B123, B126 AFNOR A, AFNOR C, DCF- FSK, IRIG-B126 IEEE 1344 max. 550 m max. 275 m typical > 1250 request/sec typical < ± 100 µs typical < ± 10 µs typical < ± 100 µs typical < ± 1 µs typical < ± 100 µs typical < ± 10 µs typical < ± 10 ms ± 10 µs to UTC < ± 10 ms/d or < 0.1 ppm < ± 1ms/d or < 0.01 ppm < ± 250 ms/d or < 2.5 ppm DTS 4136 -> OCXO Hold over (after > 24h synch. from GPS) at 20 C ± 5 C: < ± 1 ms/d or < 0.01 ppm External time source External / S server (4 sources possible), or DCF 77 time signal receiver (optocoupler, e.g. DCF 4500), or GPS time signal receiver (optocoupler, e.g. GPS 4500), or IRIG-B 12x/AFNOR (analog) Manual time setting (only for test purposes) Alarm relay Potential free, opening contact for signalizing disturbances open -> alarm Alarm input 1 alarm input for monitoring of an external device, 18-36 VDC, max. 6 ma input open -> alarm Power supply AC input: 90 to 240 VAC / 50-60 Hz / 0.25 A 2 x DC input: 24 VDC +20 % / -10 % / 20 W DC output nominal 28 VDC, max. 400 ma Dimensions 19 rack, 1 rack unit, W x H x D 483 x 44 x 125 mm Weight Power reserve Ambient temperature Options No internal active running reserve, timekeeping with RTC for short power outages -5 to +50 C, 10-90 % relative humidity, without condensation Mini GBIC module (GigaBit Interface Converter) SX LC 1000Mbps, 3.3V fiber optic cable, 2xLC/LC50/125µm patch cable FiberChannel duplex 100 cm approx. 1.8 kg LE-800720.05