Typical Anti-Sweat Heaters run 24 hours a day 365 days a year in order to keep reach-in cooler and freezer doors free of condensation.

Similar documents
Professional Refrigerated Displays for Confectionery & Ice Cream

Measure Guidelines. for EnergySmart Grocer (ESG)

PPL Electric Utilities Energy Efficiency and Conservation Program

Air to water Heat Pump System

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

2 Building Type. 3 Trade Ally/Contractor Information. Refrigeration Rebate Worksheet. Retrofit New Construction

DES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT. 806 E. Hoffman Street Des Moines, IA ADDENDUM NO.

These units are available now from the Distribution Center. For a list of available models, click here.

BLOOD PLASMA Walk-in Freezers

incomparably cool XC21 The most quiet and efficient central air conditioner you can buy*

Refrigerant and Energy Regulations Update

Proven Energy-Saving Technologies for Commercial Properties

ACT - VS ULTIMATE ENERGY SAVING TECHNOLOGY NEW - ENERGY SAVING VARIABLE SPEED DRYERS BY FRIULAIR

The Impact of Product Innovation and Up-Marketing on Appliance Purchase Behavior

COMMERCIAL ENERGY SAVINGS GUIDE

quick start guide Product features RF4287HA English Surround Multi Flow

Sustainable Techniques in Refrigerated Space

Equipment Efficiency Guide

All Freestanding SxS Refrigerators

Air to water Heat Pump System

Repair Parts List REFRIGERATOR MODEL NUMBER GT15B83V. When requesting service or ordering parts, always provide the following information:

Cool Savings Program Report

Refrigeration Systems Handbook

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

quick start guide Product features RFG26M*** English Counter Height Design Surround Multi Flow Secure Auto Close Door System Twin Cooling System

Walk-in Refrigerated Rooms. An Overview of Requirements, Options and Construction Details

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations. KaTom Restaurant Supply, Inc.

Thermo Fisher Scientific ULT Clinic. Peter Diebold Cold Storage Specialist

Direct Install Program Eligible Measures Listing:

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

A Complete Line Of Remote Rack Refrigeration Systems

Modular Active. Chilled. Beams

at a glance Energy FinAnswer Case Study: Albertsons Energy FinAnswer is the best-run, best-delivered program we ve been involved with.

B a r Re f r i g e r a t i o n

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

2018 Special-Lite ALUMINUM HARDWARE & LITES

VWR Laboratory Refrigerators and Freezers

SDG&E s Business Energy Solutions Program 2018 Product Catalog

Non-Intrusive Load Monitoring (NILM) Presentation to the EEAC May 25 th, 2016

REVCO MECHANICAL CRYOGENIC FREEZER

XP21 The most quiet and efficient heat pump you can buy*

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

Incentive & Measure Specifications

Low-Income Refrigerator Replacement Selecting the Worst of the Worst

Sub-Zero offers two distinctive different models with

Tube-in-tube heat exchanger Type HE

Copeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration

Global. Refrigeration, INC. QUALITY REFRIGERATION PRODUCTS Grant Avenue, Cleveland, OH

Understanding Applications for Alternative Refrigerants

One of the most popular units within the inventory

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

2007 Itemized (Express Efficiency) Measures

Extended Range DUAL TEC Motion Sensor

Refrigeration Product Sales Training FREEDOM Collection

Evaluating Cost and Energy Implications in Refrigerator Design

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Commercial and Professional Refrigeration Products: Promoting Energy Efficiency with Legislation, Empowered Stakeholders and Rebates

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations

Suction Accumulators. Introduction. Suction Accumulators

- TECHNICAL NOTES SUPPLEMENT TO PROJECT WORKSHEET -

GE Profile and GE Bottom-Freezer Refrigerators. The Ultimate in Refrigeration. Rethought. Reinvented. Revolutionized. We bring good things to life.

AHRI Standard 1250P (I-P) 2009 Standard for Performance Rating of Walk-In Coolers and Freezers

Reduce your energy use and save money year-round with ENERGY STAR certified appliances.

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Case Study: SUPERMARKET APPLICATION

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

LV Installation Manual

Heat Pump Water Heater Commercial Leaflet 2012

The Glass Sentry line of anti-sweat heater controls is designed to conserve the electricity consumption of the heater

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

Using Adaptive Defrost Control Technology to Improve Energy Savings in the Food Service Industry.

Drop-Ins Wide offering Exceptional Performance

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

How to Meet 2017/2020 Energy Regulations

PLEASE READ CAREFULLY BEFORE OPERATION

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Side-by-side combined refrigerator-freezer

A REA L IGHTING A DIFFERENT WAY OF LIGHT

Maluna Unhinged vs Yeti Tundra Thermal Performance Comparison January 2017

2012 Catalog Version AUG 2012 Noritz America Corporation. All rights reserved.

LV Installation Manual

Walk-Ins & Refrigeration Systems

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

UNDER-COUNTER WINE COOLERS

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

NOVA Products. Quality Refrigeration Since Reach-in, Roll-in & Pass-Thru Cabinets & Heated Cabinets. Open Air Merchandisers

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

TrueAlert Addressable Notification

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

REACH-IN SAFETEMP (-AAC)

Upgrade Your Comfort

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

Instrumentation and Controls Group

CN7232 Advanced Garage Ventilation Controller

2017 Synthetic Greenhouse Gas Levy Report

SAVCFB/SAFDFB Quiet Cool Built-In 91cm width All Freezer

2016 Synthetic Greenhouse Gas Levy Report

ThermoSaver TM Hot Gas Defrost System

Transcription:

Typical Anti-Sweat Heaters run 24 hours a day 365 days a year in order to keep reach-in cooler and freezer doors free of condensation. The reality is that this function is only needed approximately 15-20% of the time. All of that additional runtime equates to excessive energy use and expense. Madison Energy Anti-Sweat Heater Door Controls provide a means to reduce energy by up to 80% by modulating the Anti- Sweat Heaters with sensor based technology so that they only operate when needed.

Realize dramatic energy savings in your reach-in refrigeration systems with the Madison Energy Anti-Sweat Heater Controls (ASH-DC). The built-in programmed maintenance cycle (PMC) technology assures that all display cases remain sweat, frost and ice free. Random-start technology assures that the PMC will cycle at different times on different cases even if there is a loss of power, which is what allows the Madison Energy ASH-DC to save significantly more energy than all other competitors.

Typical Refrigerator Case Configuration Refrigerated Cases without ASHDC All heaters activated all the time, continuously using energy Refrigerated Cases with ASHDC Use up to 80% less energy by activating heaters only on doors that require heat

ASHDC-MT Anti-Sweat Heater Door Control (Coolers) CAPTURE ALL POTENTIAL ANTI-SWEAT HEATER SAVINGS Anti-Sweat Heater Door Control utilizes a digital moisture sensor to activate the anti-sweat heaters only when the threat of moisture is present. The ASHDC-MT controller is mounted in the inside of the walk-in cooler, out of sight of customers. The maintenance free operation of the ASHDC-MT controller has a sensitivity slide switch to maximize savings while assuring sweat-free doors year round. EXCLUSIVE PROGRAMMED MAINTENANCE CYCLE PMC TECHNOLOGY Built-in to assure that all areas of the display case remain sweat, frost and ice free. The PMC activates the heaters for 15 minutes, once every three hours. Manufacturers of glass display doors recommend that anti-sweat heaters do not remain off for long periods of time. Sweat, frost and ice can build up in areas such as mullion chambers, electrical raceways, door gaskets, etc. if heaters are not activated and remain on for at least 15 minutes. In addition, the PMC has been engineered with random start technology, assuring that the PMC will cycle at different times on different cases, even if there is a loss of power. The random start technology also assures that the ASHC-MT Anti-Sweat Heater Door Control System will capture significant demand savings on your anti-sweat load.

ASHDC-LT Anti-Sweat Heater Door Control (Freezers) EXCLUSIVE TWO-CHANNEL TECHNOLOGY Maximize the energy efficiency of your glass display doors with ASHDC-LT Anti-Sweat Heater Door Control System. The exclusive two-channel technology operates door heaters independently from frame and mullion heaters. Customers utilizing ASHDC-LT realize 5-20% savings on their overall energy usage. ASHDC-LT is easily installed in your existing cases and walk-ins, with no additional wiring necessary. Precise placement of the moisture sensors offers maximum savings while assuring proper heater control. EXCLUSIVE PROGRAMMED MAINTENANCE CYCLE PMC TECHNOLOGY Built-in to assure that all areas of the display case remain sweat, frost and ice free. The PMC activates the frame and mullion heaters for 15 minutes, then activates the door heaters for 15 minutes, once every three hours. Manufacturers of glass display doors recommend that anti-sweat heaters do not remain off for long periods of time. Sweat, frost and ice can build up in areas such as mullion chambers, electrical raceways, door gaskets, etc. if heaters are not activated and remain on for at least 15 minutes. In addition, the PMC has been engineered with random start technology, assuring that the PMC will cycle at different times on different cases, even if there is a loss of power. The random start technology also assures that the ASHDC-LT Anti-Sweat Heater Door Control System will capture significant demand savings on your anti-sweat load.

Features Mid-temperature range (MT) and low-temperature range (LT) controllers available Built-in programmed maintenance cycle (PMC) technology Selective heater activation only when condensations level reach a specific threshold MT controls utilize digital moisture sensors that activate upon threat of moisture LT controls utilize two-channel technology that operates doors independently from the frame and mullion heaters Precise placements of sensors assure proper heat control

Benefits Maximize energy savings up to 80% Display cases remain sweat, frost and ice free Easy to install into existing display cases and walk-ins without additional wiring Materials and components exceed UL and ULC standards Limited three-year replacement warranty Eligible for utility rebate programs

5 West Hargett St. 4 th Floor Raleigh, NC 27601 Phone: 919-443-2404 www.themadisonenergygroup.com