SIHI LPH-X - Liquid Ring Vacuum Pump

Similar documents
SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

PRODUCT INFORMATION. Liquid ring vacuum pumps Liquid ring compressors. Series LVP

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Specially Designed Waste Water & Sewage Pumps

Selfpriming Centrifugal Pumps. Type HZS/HZSA

Experience In Motion. SIHI Liquid Ring Compressors

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm

Excellent Engineering Solutions. Solids Handling Pumps. Recessed Vortex Impeller Pumps CLEAR LIQUID

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

Liquid ring vacuum pumps

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump

Pumps Mixers Aeration Controls Services SCANPUMP PROCESS PUMPS, BE SERIES. NO-COMPROMISE PUMPING.

CR A-F-A-E-HQQE 3x400/ HZ

Vertical Ring-section Pump WKTB. Type Series Booklet

CLOSED COUPLED CENTRIFUGAL PUMPS

SIHI multi Modular multistage pumps

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

CR A-F-A-V-HQQV 3x400D 50 HZ

MODERN TECHNOLOGIES AND LONG - TERM EXPERIENCE

Installation, Operation and Maintenance Manual. 3AV 1 to 3AV 430

MARINE. High efficiency pumps you can rely on

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

UP/UPS-B/UPN Hot Water Service Circulators

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

Premium freezers combining functionality, elegance and energy efficiency

CombiBloc Close-coupled centrifugal pumps

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

SECTION STEAM CONDENSATE PUMPS

GLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF. Vertical Submersible Pump

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

Wilo IL Vertical Split-Coupled Inline Pumps

DIAPHRAGM VACUUM PUMPS FOR AUTOCLAVES

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA

TP /4-A-F-A-BQQE 400D 50HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

SL S.S.N.51D

SIHI Dry GD S Sizes S450, S650

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

EMVO SINGLE STAGE OIL SEALED ROTARY VANE VACUUM PUMPS SUPERVANE (ROTARY VANE+BOOSTER COMBINATION VACUUM SYSTEMS)

Industrial Pump Solutions

Liquid Ring Vacuum Pumps, Compressors and Systems

CRN A-F-G-E-HQQE 3x400D 50 HZ

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

Self-priming centrifugal pumps

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SIHI dry Dry running vacuum pumps

MCV - MCH - MCHZ Multistage pumps

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

HIGH PRESSURE DOUBLE CASE PUMPS

Transformer oil coolers BETA & CETA

SL EX.4.51D

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

EVMSU - Vertical Multistage Pumps. Product Catalog

CombiPrime Self-priming centrifugal pumps

micropac. Personal Gas Detection Instruments

DIAPHRAGM VACUUM PUMPS

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y HVN. Double Suction, Heavy Duty API 610 Process Pump (BB2)

Design and Construction Standards SECTION PLUMBING EQUIPMENT

IWAKI HI-CERA PUMPS V

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

Accuracy counts! Sensors with analog output

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Torqueflow Sydex. Fluid Management. K Range Pumps

TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS

CNS CENTRIFUGAL MULTISTAGE WATER DESCALING PUMPS BB4 TYPE API 610 ENGINEERING FLOW SOLUTIONS

DUPLEX CONDENSATE TANK SYSTEM

Experience In Motion. SIHI Multi Modular Multistage Pumps

KRAL Screw Pumps. L Series.

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Lenntech. Tel Fax bar. Multistage Pumps.

VersaFlow Mag 2000 FL Electromagnetic Flow Sensor Technical Datasheet. Specification. Solution with high-tech ceramics. Highlights.

Multifunction pump for handling gaseous liquids in process engineering

CR20-07 A-F-A-E-HQQE 3x400/ HZ

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

CombiBloc. Close-coupled centrifugal pumps

Inline-Pumps Type NCV /NCVL

FEATURES. Vacuum Motor. Moving Ahead With Technology

Transcription:

- Liquid Ring Vacuum Pump Two Stage LPH 45008, LPH 45311, LPH 45316 Pressure Range: Suction Volume: 33 to 1013 mbar 55 to 258 m³/h CONSTRUCTION Sterling SIHIliquid ring vacuum pumps have a simple but robust construction with the fo lowing features and benefits: Near isothermalcompression Oilfree,with no internallubrication Capable ofhandling almost a lgases and vapours Able to handle quantities ofliquid carry over Low maintenance and safe operation Low noise and almost vibration free Available in a wide range ofmaterials Broad range ofapplications O-ring sealing as standard Cavitation protection as standard Drain hole as standard Built-in solids drain Rotating meta lic parts are non contacting to minimise wear ATEX compliance Sterling SIHIliquid ring vacuum pumps ofthe range LPH 45008, LPH 45311 and LPH 45316 are two stage pumps. In addition,the LPH 45008 and LPH 45316 can be used as compressors without any modification. (see the Technical Catalogue - Liquid Ring Compressors) APPLICATIONS Evacuation and pumping ofdry gases and saturated vapours. The pumps can also handle liquids. These units o fer pressures in the range of33...900 mbar(a)to atmospheric. Much lower pressures are available by using ancilaries such as ejectors and lobular boosting pumps. Typicalapplication areas include: Chemicaland pharmaceuticalindustry for distilation,drying and degassing Food and beverage industry for low temperature cooking, and bottle filing Electronic industry for impregnation and drying Plastics & Rubber industry for degassing Healthcare for sterilisers and generalvacuum Note By continuously feeding the pump with a sma lamount ofservice liquid (usua ly water),the heat due to gas/vapour compression is conducted away. This also replenishes the liquid ring and ensures that it does not become saturated with process media. Recharging the pump with service liquid at ambient temperature enables the unit to condense evacuated gases /vapours. It can therefore be used for solvent recovery. The condensed gas and liquid can be separated in a liquid separator. More information is provided in the accessory catalogues. The integrated solids drain permits the removalofany entrained solids whilst the pump is operating. The service liquid can therefore, simply be re-circulated. The rotation of the pump is clockwise when viewed from the drive end. GENERAL TECHNICAL DATA Pump Type Units LPH 45008 LPH 45311 LPH 45316 Speed 50 Hz rpm 1450 60 Hz rpm 1740 Maximum overpressure on compression bar 1.5 Maximum permissible pressure diference bar 1.5 1.5 1.2 W ater pressure test (Overpressure) bar 3.0 Moment ofinertia ofrotating parts ofpump and ofwater content kg. m² 0.05 0.063 0.09 Noise levelat 80 mbar suction pressure db (A) 65 Minimum permissible pu ley diameter for V belt drive mm 160 Max. gas temperature: dry saturated Service liquid: Max. permissible temperature Max. viscosity Max. density C mm²/s kg/m³ 100 90 1200 Liquid capacity up to middle ofshaft litre 4.0 5.5 7.0 Maximum flow resistance ofthe heat exchanger bar 0.2 C C In selecting a pump,avoid choosing one which is likely to be operating at a combination ofits maximum permissible limits e.g. maximum viscosity and maximum permissible pressure diference. 120 100 VACUUM TECHNOLOGY LPH LII 3 133.71225.58.01 E 08/03

Materials Materials Position Number Component 0A 0B SZ 4B 10.60 Casing 0.6025 1.4408 10.90 Central Body 0.6025 1.4408 13.70, 13.71 Guide Disc 0.6025 1.4404 23.50, 23.51 Impeller 2.1096.01 1.0619 1.4517 21.00 Shaft 1.4021 1.4401 43.30, 43.31 Mechanical Seal, Type SIHI FK (AG ) 43.30, 43.31 Mechanical Seal, Type Sterling GNZ (AF ) Cr-Steel / Carbon / Butadiene rubber Cr Ni Mo-Steel / Carbon / Viton SiC / Carbon / Viton SiC / Carbon / Teflon Cut-away diagram LPH 45008, LPH 45311, LPH 45316 2

Performance Characteristics LPH 45008 150 m³/h 1740 rpm suction volume flow 100 50 1450 rpm LPH 45008 0 10 40 60 100 200 400 1000 suction pressure mbar kw power absorption 4 3 2 1 1450 rpm 1740 rpm LPH 45008 0 10 40 60 100 200 400 1000 suction pressure mbar The operating data is valid under the following conditions: Process media: - dry air: 20 C - steam saturated air: 20 C Service liquid: - water: 15 C Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure) The suction volume is related to the suction pressure Tolerance on operating data is 10% The maximum consumption of make up water occurs at the lowest suction pressure 3

Performance Characteristics LPH 45311 200 m³/h suction volume flow 150 100 1740 rpm 1450 rpm LPH 45311 50 10 40 60 100 200 400 1000 suction pressure mbar kw power absorption 5 4 3 2 1450 rpm 1740 rpm 1 LPH 45311 0 10 40 60 100 200 400 1000 suction pressure mbar The operating data is valid under the following conditions: Process media: - dry air: 20 C - steam saturated air: 20 C Service liquid: - water: 15 C Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure) The suction volume is related to the suction pressure Tolerance on operating data is 10% Maximum consumption of make up water occurs at the lowest suction pressure 4

Performance Characteristics LPH 45316 300 m³/h suction volume flow 200 100 1740 rpm 1450 rpm LPH 45316 0 10 40 60 100 200 400 1000 suction pressure mbar 8 kw power absorption 6 4 2 1450 rpm 1740 rpm LPH 45316 0 10 40 60 100 200 400 1000 suction pressure mbar The operating data is valid under the following conditions: Process media: - dry air: 20 C - steam saturated air: 20 C Service liquid: - water: 15 C Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure) The suction volume is related to the suction pressure Tolerance on operating data is 10% Maximum consumption of make up water occurs at the lowest suction pressure 5

Dimensions LPH 45008, LPH 45311, LPH 45316 N 1 = Gas-Inlet DN 40 N 2 = Gas-Outlet DN 40 u B = Connection for Service Liquid G ½ u c = Connection for Cavitation Protection G 1 / 8 u e = Connection for Drain G 1 / 8 u se = Connection for Dirt Drain G 1 / 8 u L = Connection for Air Cock G ½ u m = Connection for Pressure Gauge G ¼ u m1 = Connection for Drainage Valve or Liquid Level Sensor G ¼ a m 1 m 2 o 3 Approx Weight (mm) (mm) (mm) (mm) (kg) LPH 45008 239 353 299 526 65 LPH 45311 269 383 329 556 70 LPH 45316 339 453 399 626 80 6

LPH 45008, LPH 45311, LPH 45316 with Top-Mounted Liquid Separator N 1 = Gas-Inlet DN 40 N 2 = Gas-Outlet DN 50 u A = Liquid Drain G 1 u F = Connection for Make Up Water Ø18 u c = Connection for Cavitation Protection G 1 / 8 u c1 = Connection for Cavitation Protection G 1 / 8 E-Motor 50 Hz Approx Size kw Base- a b c d e 1 e 2 h h 1 h 2 h 3 l l 1 v o 1* Weight IP 55 EEx e ll T3 plate [mm][mm][mm][mm] [mm] [mm][mm][mm][mm][mm] [mm] [mm][mm] [mm] [kg] LPH 100 L 3.0 - S303 239 390 25 19 600 350 65 877 592 117 920 339 160 375 140 45008 112 M - 3.6 395 150 LPH 112 M 4.0-269 997 369 165 45311 132 S - 5.0 S344 450 30 24 660 400 80 1012 607 132 1020 180 455 205 LPH 132 S 5.5-339 439 200 45316 132 M - 6.8 495 235 *Dimensions dependent upon motor supplier Flange dimensions according to DIN 2501 PN 10 (mm) DN 40 50 k 110 125 D 150 165 Number x d 2 4 x 18 4 x 18 7

LPH 45008, LPH 45311, LPH 45316 with Side-Mounted Liquid Separator N 1 = Gas-Inlet DN 40 N 2 = Gas-Outlet DN 50 u A = Liquid Drain G 1 u c = Connection for Cavitation Protection G 1 / 8 u c1 = Connection for Cavitation Protection G 1 / 8 u e1 = Connection for Drainage G ½ u F = Connection for Make Up Water Ø18 u FL = Connection for Liquid Level Indicator G ½ E-Motor 50 Hz Approx Size kw Base- a b c d e 1 e 2 h h 1 l l 1 v o 1* Weight IP 55 EEx e ll T3 plate [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg] LPH 100 L 3.0 - S303 239 390 25 19 600 350 65 0 920 339 160 375 160 45008 112 M - 3.6 395 170 LPH 112 M 4.0-269 369 170 45311 132 S - 5.0 S344 450 30 24 660 400 80 15 1020 180 455 210 LPH 132 S 5.5-339 439 215 45316 132 M - 6.8 495 250 * Dimensions dependent upon motor manufacturer Flange Connection Dimensions according to DIN 2501 PN 10 (mm) DN 40 50 k 110 125 D 150 165 Number x d 2 4 x 18 4 x 18 8

Make-up Liquid Consumption in [m³/h] dependent upon suction pressure, speed, drive type and temperature difference. SIHI LPH-X Suction pressure in [mbar] Pump Type Speed (rpm) 33 120 200 400 KB KB KB KB Temperature FB Temperature FB Temperature FB Temperature Difference C Difference C Difference C Difference C 10 5 2 10 5 2 10 5 2 10 5 2 LPH 45008 1450 0.17 0.28 0.48 0.17 0.28 0.46 0.18 0.29 0.46 0.18 0.28 0.43 1750 0.23 0.36 0.56 0.9 0.22 0.35 0.53 0.8 0.22 0.34 0.51 0.75 0.22 0.33 0.46 LPH 45311 1450 0.19 0.31 0.51 0.20 0.32 0.50 0.21 0.33 0.50 0.21 0.31 0.45 0.65 1750 0.24 0.38 0.59 0.25 0.38 0.55 0.26 0.38 0.54 0.25 0.36 0.49 LPH 45316 1450 0.24 0.38 0.61 1.0 0.25 0.40 0.60 0.9 0.27 0.40 0.59 0.85 0.25 0.36 0.49 1750 0.30 0.47 0.69 0.31 0.47 0.65 0.32 0.47 0.64 0.30 0.41 0.53 FB = Total service liquid flow rate on once-through system KB = Flow of make-up water when combined with partial recirculation liquid at a temperature of 10 C, 5 C, 2 C, warmer than makeup water. FB Product Code order details Range + Size Hydraulic and Bearings Shaft Seal Materials Casing Sealing 45008 A B 1.Hydraulic Two greased roller bearings AGE AG1 AFJ AFK Mechanical seal type SIHI FK, O-Rings Butadiene rubber Mechanical seal type SIHI FK, O-Rings Viton Mechanical seal type Sterling GNZ, O-Rings Viton Mechanical seal type Sterling GNZ, O-Rings Teflon coated (Viton heart) 0A 0B SZ 4B Main parts from cast iron (GG) and impellers in bronze Similar to 0A, but impellers in steel Similar to 0A, however impellers and guide discs are in stainless steel Main parts out of stainless steel 1 O-Ring Sealing LPH 45311 AB AGE, AG1, AFJ, AFK 0A, 0B, SZ, 4B 1 45316 Motor Selection Table E-Motor 50 Hz 1450 rpm 230 or 400 V Motor Protection IP 55 kw Size Motor Description Motor Protection EEx e ll T3 kw Size Motor Description 3.0 100 L LB 3.6 112 M MK e.g. 4.0 kw AC motor 4.0 112 M MB 5.0 132 S NK (50 Hz, 400 V ) at 1450 rpm 5.5 132 S NB 6.8 132 M PK Example of an Order: The pump LPH 45311 AB AGE 0A 1 with 4.0 kw AC motor (50 Hz, 400 V ) 1450 rpm has the complete order number: LPH 45311 AB AGE 0A 1 MB.For motors with other voltages and frequencies please request information. 9

Spare Parts Order Number Material Design 0A Group Spare Parts Kit LPH 45008 LPH 45311 LPH 45316 10.00 Hydraulic 65 006 832 65 006 833 65 006 834 20.00 Shaft 65 006 712 65 006 711 65 006 710 30.00 Bearing 65 006 746 40.00 Shaft seal AGE 65 006 747 40.00 Shaft seal AFJ 65 006 841 Material Design SZ Group Spare Parts Kit LPH 45008 LPH 45311 LPH 45316 10.00 Hydraulic 65 006 751 65 006 752 65 006 753 20.00 Shaft 65 006 712 65 006 711 65 006 710 30.00 Bearing 65 006 746 40.00 Shaft seal AGE 65 006 747 40.00 Shaft seal AFJ 65 006 841 Material Design 0B Group Spare Parts Kit LPH 45008 LPH 45311 LPH 45316 10.00 Hydraulic 65 006 743 65 006 744 65 006 745 20.00 Shaft 65 006 712 65 006 711 65 006 710 30.00 Bearing 65 006 746 40.00 Shaft seal AGE 65 006 747 40.00 Shaft seal AFJ 65 006 841 Material Design 4B Group Spare Parts Kit LPH 45008 LPH 45311 LPH 45316 10.00 Hydraulic 65 006 751 65 006 752 65 006 753 20.00 Shaft 65 006 757 65 006 758 65 006 759 30.00 Bearing 65 006 746 40.00 Shaft seal AG1 65 006 761 40.00 Shaft seal AFK 65 006 842 10

Accessories Recommended Accessory Material Execution LPH 45008 LPH 45311 LPH 45316 Top Mounted Liquid Separator Type / Weight XBa 1040 / 10 kg XBa 1340 / 14 kg Top mounted separator Service liquid pipework, standard execution Service liquid pipework, thermostatic control 24V Cavitation protection pipework +Brass + Brass SIHI-Part No. 43 051 766 43 053 806 SIHI-Part No. 20 058 985 20 058 993 SIHI-Part No. 20 059 008 20 048 978 SIHI-Part No. 20 040 424 20 040 423 Side Mounted Liquid Separator Type / Weight XBp 0413 / 28 kg Side mounted separator Service liquid pipework, standard execution Service liquid pipework, thermostatic control 24V Cavitation protection pipework Pressure pipework (bend) 1.0254 Liquid level indicator Sterling SIHI - Gas Ejector +Brass + Brass Brass + Plexiglas + Plexiglas SIHI-Part No. 43 051 835 43 051 831 SIHI-Part No. 20 058 979 20 058 987 20 058 980 20 058 988 SIHI-Part No. 20 049 503 20 050 725 SIHI-Part No. 20 044 682 20 044 681 SIHI-Part No. 35 003 165 35 003 166 SIHI-Part No. 43 014 911 43 040 384 43 052 694 43 053 532 20 058 981 20 058 989 At service liquid temperature 15 C Type / Weight GPV 4011 / 13 kg - GPV 4012 / 20 kg At service liquid temperature 30 C Type / Weight GPV 4311 / 12 kg GPV 4312 / 13 kg GPV 4313 / 13 kg Sterling SIHI - Non Return Ball Valve Intermediate flange execution XCk 40 Flange execution with glass cylinder XCk 406 Drain Valve XCg 015 Double nipple ½ -¼ Air Inlet Valve Motor Motor Standard execution IP 55 Coupling for Motor IP 55 Pump side Motor side 0.6025 +Butadiene Rubber 0.6025 +Teflon 1.4408 +Teflon 0.6025 +Butadiene Rubber 0.6025 +Teflon 1.4408 +Teflon Steel Brass SIHI-Part No. Weight SIHI-Part No. Weight 43 016 890 / 2.8 kg 43 016 891 / 2.8 kg 43 030 996 / 5.2 kg 43 014 651 / 7.0 kg 43 014 652 / 7.0 kg 43 014 650 / 7.0 kg SIHI-Part No. 43 014 545 43 014 546 SIHI-Part No. 43 049 216 43 013 084 SIHI-Part No. 43 014 257 43 014 271 Size Power Weight Type / Weight SIHI-Part No. 100 L 3.0 kw 20 kg B 95 / 2.6 kg 43 021 426 43 021 432 112 M 4.0 kw 28 kg Coupling guard Steel SIHI-Part No. 43 042 248 Motor in EEx e ll T3 execution Coupling for Motor EEx e ll T3 Pump side Motor side Size Power Weight Type / Weight SIHI-Part No. 112 M 3.6 kw 30 kg BDS 103 / 3.1 kg 43 026 564 43 025 940 132 S 5.0 kw 65 kg Coupling guard Brass SIHI-Part No. 43 042 249 Baseplate Steel Type / Weight SIHI-Part No. S 303 / 36 kg 43 040 635 BDS 103 / 3.1 kg 43 026 564 43 025 941 132 S 5.5 kw 45 kg B 95 / 2.6 kg 43 021 426 43 021 433 132 M 6.8 kw 80 kg S 344 / 48 kg 43 040 637 11

www.sterlingfluidsystems.com Europe www.sterlingfluidsystems.com/europe Sterling Fluid Systems (Austria) W ien Telephone: +43 (0)1 680 050 Fax: +43 (0)1 680 0521 E-Mail: sales_austria@ sterlingsihi.de Sterling Fluid Systems (France) Trappes Telephone: +33 (0)1 34 82 39 00 Fax: +33 (0)1 34 82 39 61 E-Mail: sterlingsihi@ easynet.fr Sterling Fluid Systems (Greece) Athens Telephone: +30 (0) 210 957 07 83 Fax: +30 (0) 210 956 81 21 E-Mail: sales_greece@ sterlingsihi.de Sterling Fluid Systems (Netherlands) Beverwijk Telephone: +31 (0)251 263 232 Fax: +31 (0)251 226 309 E-Mail: info@ sihi.nl Sterling Fluid Systems (Schweiz) Schaffhausen Telephone: +41 (0)52 6440606 Fax: +41 (0)52 6440616 E-Mail: info@ sterlingfluid.ch Sterling Fluid Systems (Belgium) Groot-Bijgaarden Telephone: +32 (0)2 481 7711 Fax: +32 (0)2 481 7737 E-Mail: sales@ sterlingfluidsystems.be Sterling SIHI(Germany) Itzehoe Telephone: +49 (0)4821 77101 Fax: +49 (0)4821 771274 E-Mail: sales@ sterlingsihi.de Sterling Fluid Systems (Hungary) Veszprém Telephone: +36 (0)88 40 66 33 Fax: +36 (0)88 40 66 35 Mail: sales_hungary@ sterlingsihi.de Sterling Fluid Systems (Polska) W arzawa Telephone: +48 (0) 22 849 7097 Fax: +48 (0) 22 849 6726 E-Mail: sterling@ sterling.pl Sterling Fluid Systems (Spain) Madrid Telephone: +34 91 709 1310 Fax: +34 91 715 9700 E-Mail: mibsa@ stnet.es Sterling Fluid Systems (Czech Republic) Olomouc Telephone: +420 (0) 68 551 6651 Fax: +420 (0) 68 551 6653 E-Mail: sterling@ sterling.cz Sterling SAT Dägeling Telelphone: +49 (0) 4821 9000-0 Fax: +49 (0) 4821 9000-501 E-Mail: sat@ sterlingsat.com Sterling Fluid Systems (Italy) Cologno Monzese Telephone.:+39 02 82 41 Fax: +39 02 82 24 220 E-Mail: sterlingitaly@ sidro.it Sterling Fluid Systems (Romania) Bucuresti Telephone: +40 (0) 21 610 7188 Fax: +40 (0) 21 210 8287 E-Mail: sales_romania@ sterlingsihi.de Sterling Fluid Systems (UK) Altrincham/Cheshire Telephone: +44 (0)161 9286371 Fax: +44 (0)161 9252129 E-Mail: uksales@ sterlingfluid.com Sterling Fluid Systems (USA) Grand Island Telephone: (1) 716 773 6450 Fax: (1) 716 773 2330 E-Mail:mail@ sihi.com Americas www.sterlingfluidsystems.com/americas Sterling Fluid Systems (Canada) Guelph Telephone: (1) 519 824 4600 Fax: (1) 519 824 7250 E-Mail: mail@ sihi.com Sterling Fluid Systems (Asia) Singapore Telephone: (65) 6863 0828 Fax: (65) 6863 0868 E-Mail: asia.marketing@ sterlingasia.com Sterling Fluid Systems (Malaysia) Selangor Darul Ehsan Telephone: (60) 3 8070 0198 Fax: (60) 3 8070 0204 E-Mail:sfsmsia@ tm.net.my Asia www.sterlingfluidsystems.com/asia SIHI(Australia) Bayswater Telephone: (61) 3 9720 1500 Fax: (61) 3 9720 4076 E-Mail: sfsaus@ ozemail.com.au Sterling Fluid Systems (Philippines) Muntinlupa City Telephone: (63) 2 809 4908 Fax: (63) 2 807 2013 E-Mail: philippines@ pacific.net.ph Sterling Fluid Systems (China) Shanghai Telephone: (8621) 6336 3488 Fax: (8621) 63268487 E-Mail: info.china@ sterlingasia.com Sterling Fluid Systems (Thailand) Bangkok Telephone: (66-2) 319 2567 Fax: (66-2) 319 2573/4 E-Mail:sfsthai@ sterlingthai.co.th