EK SE G DE FI Installatörshandbok SOR för NIE F/F Installer manual SOR for NIE F/F Installateurhandbuch SOR für NIE F/F sentajan käsikirja SOR NIE F/F SOR IH - 0
G English, Installer manual - SOR General With SOR, F/F together with: VPS can be connected to solar heating for hot water charging. VPS (only F) is connected to solar heating for hot water charging. VP/heater for hot water charging via heat exchanger. The heat pump prioritises charging from the solar panel. This accessory may require a program software update in your F/F. 0 or higher is the minimum software version for the pump. Component positions -S -X EK F The water from the solar panel can reach high temperatures. The hot water side must be supplied with a mixing valve. -X -F -X X Electrical components F Miniature circuit-breaker. 0 Contents x Cable ties X Terminal block, power supply ccessory card x x x x Unit box (comprising, F and X). Heating pipe paste luminium tape Insulation tape -X -X -X Terminal block, sensors and external blocking Terminal block, communication Terminal block, circulation pump, mixing valve and auxiliary relay x Temperature sensor (T), black -S DIP switch x Temperature sensor, high temp (T), transparent -F Fine wire fuse, TH0V Designations in component locations according to standard IEC - and -. 0
G Pipe connections Charge pump Place the charge pump (GP) on the return line to the solar panel according to the outline diagram. Temperature sensor Sensor, solar panel (T) is placed in the solar panel's submerged tube by the outlet from the solar panel. Sensor, solar coil (T) is positioned in submerged tube U (VPS). Install the temperature sensors with cable ties with heat conducting paste. NOTE Sensor and communication cables must not be placed near power cables. NOTE See manual for VPS for more information. Suitable flows/solar panel area Recommended flow is 0 l/h per m solar panel area.
G Outline diagram Explanation E External additional heat CM Expansion vessel, closed E External electrical additional heat F0 Safety valve, heating medium side QM - Shut-off valve, heating medium side QM RN Trim valve E00 Heat pump system T Temperature sensor, outdoor T Temperature sensor, hot water T Temperature sensor, external flow line T Temperature sensor, external return line E00 Heat pump EP Cooling module EP Cooling module F0 - Safety valve, collector side F F - Safety valve, heating medium side F HQ Particle filter HQ - HQ QM0 - Shut-off valve, brine side QM QM - Shut-off valve, heating medium side QM QN0 Reversing valve, heating/hot water RM0 - Non-return valve RM EP0 SOR ccessory card T Sensor, solar panel T Sensor, solar coil GP0 Pump station F Safety valve, solar GP Circulation pump, solar QM - Shut-off valve QM RM - Non-return valve RM QZ Hot water comfort ccessory card T0 Temperature sensor, hot water flow FQ Mixer valve, hot water GP Circulation pump, domestic hot water circulation RM Non-return valve RN0 Trim valve Miscellaneous P Manometer, brine side CM, CM CM CM CP0 CP0 E0 EP EP F F GP0, GP QM QM QM QM QM QM QM RM X X - X Expansion vessel, heating medium side evel vessel Expansion vessel, brine side ccumulator tank with solar coil uffer vessel Water heater Solar panel Ground-source heating/ground collector Safety valve, heating medium Safety valve, brine Circulation pump, heating medium external Filler valve, brine Venting valve, brine side Shut-off valve, heating medium flow Shut off valve, heating medium return Shut off valve, brine return Shut off valve, brine flow Shut-off valve Non-return valve Filling set, brine Connection, filling brine Designations in component locations according to standard IEC - and -.
G Outline diagram F with VPS and SOR -QM -E00-T -CM -F -QM -F -X -E00 -QM -CM -QM -E00 -HQ -QM -CP0 -EP0-T -E00-T -EP0 -T -EP -EP F -EP0 - -GP0 -RM T -RM -CM T P -F -GP -QM -QM -QM Outline diagram F with VPS and SOR -E -CM -E -F0 -QM -QM -RN -GP0 -RM -E00-T -E00-T -CP0 -GP -E00-T -EP0- -QZ- -QZ -GP -CM -P P -QM -F -QM -E00 -E00 -CP0 -RN0 -RM -FQ -T0 -X -X -QM -QM -HQ -F -QM -RM -QM -HQ -EP -EP -F -RM -QM -HQ -QM -RM -QM -E00-QN0 -E00 -T -EP0 -T -E0 -EP0-T -EP -EP -QM0 -RM0 -F0 -F -HQ -QM -GP0 -RM -CM T -RM T P -F -GP -QM -QM -QM
EK 0 0 0 0 N N G Electrical connection NOTE ll electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. The heat pump must not be powered when installing SOR. The electrical circuit diagram is at the end of this Installer handbook. X Connecting the supply Connect the power supply to terminal block X as illustrated. -X 0V 0Hz N -X Connecting communication This accessory contains an accessory card () that must be connected directly to the heat pump on the input card (terminal block -X) in F or on terminal block X in F. If several accessories are to be connected or are already installed, the following instructions must be followed. The first accessory card must be connected directly to the input card's terminal block (-X) in F or on terminal block X on F. The following cards must be connected in series with the previous card. Use cable type iyy, EKKX or similar. -X -X -X -X ON -X ON -X -X -X -X0 -X -X0 -X -X -X
ON -X -X 0 0 -X -X -X0 -XN G -X -X 0 0 -X The relay outputs on the accessory card can have a max load of (0 V) in total. Connecting sensors Use cable type iyy, EKKX or similar. Sensor, solar panel (T) Connect the sensor (solar panel) to -X:-. Sensor cable splicing must fulfil IP. Sensor, solar coil (T) Connect the sensor (solar coil) to -X:-. -X0 -X N -X Connecting solar panel cooling Connect solar panel cooling (if applicable) to -X: (N) and -X: (0 V). DIP switch The DIP switch on the accessory card must be set as follows. ON ON 0 Connection of the circulation pump (GP) Connect the circulation pump (GP) to -X: (0 V), -X: (N) and X: (). Unit box External -X N GP X
G Program settings Program setting of SOR can be performed via the start guide or directly in the menu system. lso see the Installer manual for F/F. This accessory may require a program software update in your F/F. 0 or higher is the minimum software version for the pump. Start guide The start guide appears upon first start-up after heat pump installation, but is also found in menu.. Menu system If you do not make all settings via the start guide or need to change any of the settings, this can be done in the menu system. Menu. - system settings ) ctivating/deactivating of accessories. Select: solar heating ) pplies to NIE F. Menu.. - accessories ) ctivating/deactivating of accessories. Select: solar heating ) pplies to NIE F. Menu.. - solar heating Settings for solar heating. Menu. - forced control Forced control of the different components in the heat pump as well as in the different accessories that may be connected. EP0--K: ctivating the circulation pump (GP). EP0--K: ctivating solar panel cooling. EP0--K: Signal to three way valve (QN). EP0--K: No function.