ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26

Similar documents
INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK

Installer manual AHP/AHPS

Installer manual AHP/AHPS

Installer manual SAM 40. Supply air module IHB GB LEK

Installation and Operating Manual

Installer manual ELK 213 Immersion heater

User manual NIBE F135

User and Installer manual NIBE UKV 20

LEK MOS UK VPA 300/200, 450/ INSTALLATION AND MAINTENANCE INSTRUCTIONS VPA 300/200, 450/300

Installer manual NIBE FLM. Exhaust air module IHB GB LEK

User manual NIBE F2016

User manual NIBE F110

User manual NIBE F , 12, 16 kw Air/water heat pump UHB GB LEK LEK LEK

Installer manual SAM 40

Installer manual SMO 40. Control module IHB GB LEK

Installer manual SMO 20. Control module IHB GB LEK

Installer manual NIBE ERS

User manual NIBE F130. Hot water heat pump

Installer manual SMO 40

User manual NIBE F2040

BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE Hot Water Storage Tank with Coil

Installer manual NIBE VVM 310. Indoor module IHB GB

Installer manual NIBE ERS

Installer manual NIBE ERS

User manual NIBE F2300

Installer manual NIBE VVM 320. Indoor module IHB GB

User manual NIBE SPLIT HBS 05 AMS 10-8 / / 10-16, HBS / 05-16

User manual NIBE SMO 05. Accessories UHB GB LEK

Installer manual NIBE VVM 310. Indoor module IHB GB

Installer manual NIBE VVM 500. Indoor module APH

Operating manual NIBE F1345. Ground source heat pump OHB GB LEK

User manual NIBE F2300

Installer manual NIBE F135

User manual NIBE F2120 8, 12, 16, 20

Installer manual NIBE VVM 320. Indoor module IHB GB

User manual AMS 10 AMS 10-6 / 10-8 / / 10-16

Installer manual NIBE VVM 310

User manual NIBE F2120 8, 12, 16, 20

Installer manual NIBE F2026. Air/water heat pump IHB GB LEK

Installer manual NIBE VVM 500. Indoor module APH

Installer manual ELK 213 Immersion heater

Installer manual NIBE F1245. Ground source heat pump IHB GB

Installer manual NIBE VVM 500

User manual NIBE SMO 05

User manual NIBE VVM 500

Installer manual NIBE F1245PC. Ground source heat pump IHB GB

User manual NIBE VVM 310

Installer manual NIBE F750. Exhaust air heat pump IHB GB LEK

User manual NIBE SMO 20

User manual NIBE F470. Exhaust air heat pump UHB GB LEK

User manual NIBE F1255

Installer manual NIBE F470

Installer manual NIBE F2300. Air/water heat pump IHB GB LEK

Installer manual NIBE F370

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 1000 VEDEX 1000 M10527 LEK

MOS GB VEDEX INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 3300 LEK

Installer manual NIBE F370

Installer manual AXC 40. Accessories IHB GB LEK

Installer manual NIBE SPLIT HBS 05

INSTALLATION AND MAINTENANCE INSTRUCTIONS EVP EVP 500 LEK

User manual NIBE F1145

User manual NIBE F470

User manual NIBE SMO 20

User manual NIBE SMO 40

User manual NIBE VVM 320

User manual NIBE F470

Installer manual NIBE VVM 325. Indoor module IHB GB APH

User manual NIBE VVM 500

Installer manual SMO 40

Installer manual AXC 30

Installer manual NIBE F2300. Air/water heat pump IHB GB LEK

Outline principle. Application Buildings with water-borne heating systems. Alternative

INSTALLATIONS MANUAL GV-HR110. Passive ventilation / Heat recovery. Version

NIBE SPLIT ACVM 270 Air/water heat pump

Outline principle. Application Buildings with water-borne heating systems. Alternative

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

SOLAR 42 IHB LEK

Installer manual SMO 40

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.

Installer manual NIBE VVM 310

MOS GB VEDEX 3300 M10528 INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 3300 LEK

Installer manual NIBE VVM 500

Installer manual SMO 40

Outline principle. Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative

Installer manual NIBE F1255. Ground source heat pump IHB GB

INSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below.

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

Installer manual SMO 20

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication

Installer manual NIBE VVM 320

MOS GB NIBE VVM INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE VVM 300 VVM 300 LEK

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V

Installer manual NIBE F1145. Ground source heat pump IHB GB LEK

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V IHB GB

INSTALLATION AND MAINTENANCE INSTRUCTIONS MOS GB NIBE VVM 300 UK NIBE VVM 300 UK 230 V VVM 300 LEK

Transcription:

MOS GB 38-2 INSTALLATION AND MAINTENANCE INSTRUCTIONS 2352 LEK

Table of Contents For Home Owners General System description Principle of operation 3 Components 3 System diagram 3 Operation and maintenance General 4 Operation 4 Safety valve 4 Venting 4 Draining 4 Actions in the event of freeze risk 4 For the Installer General information for the installer Function 5 Pipe installation 5 Electrical installation 5 Draining 5 Installation alternative Components 6 FIGHTER 1320/1330 and F1330 7 F1345 10 Miscellaneous Electrical circuit diagram Technical specifications Dimensions 13 Component positions 14 List of components 14 Technical specifications 15 Dealing with malfunctions Low room temperature 16 1

For Home Owners General General In order to get the greatest benefit from the electric heater you should read the "For Home Owners" section in this Installation and Maintenance Instruction. is an electric heater that is intended for installation together with a heat pump for heating detached houses and small apartment buildings. is a Swedish-made quality product offering long life and reliable operation. The serial number* (95) must always be stated in all correspondence with NIBE. 069 Installation date Plumber Electrician Insert any notes here. Datum Sign *The serial number can be found at the bottom corner on the inside of the electric heater. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Rights to make any design or technical modifications are reserved. NIBE 20. 2

For Home Owners System description System description Principle of operation NIBE is an electric heater that is primarily intended for installation together with a heat pump for heating buildings. contains overheat protection and contactors for external control of the three power groups, 4.0, 7.0 and 15.0 kw. Time delay recommended in compliance with the Association of Swedish Electricity Utilities norms (always apply national regulations) when connected power output exceeds 6 kw. The electric module is principally an immersion heater installed in a water container, or an electric boiler without domestic hot water heater. The stainless electric coils and electric boiler tube are made from acid proof steel (SIS 2333), which gives a very long service life. Economical A small water volume and a well insulated cassette mean small heat losses. Components AV Shut-off valve BV Non-return valve CP Circulation pump EXP Expansion vessel FG Flow line sensor RG Return line sensor RV Control valve SÄV Safety valve NOTE! This is an outline sketch. Actual installations must be planned according to applicable standards. See the relevant outline diagram for connection to the different heat pumps. System diagram Additional heat from is controlled by the heat pump. EXP SÄV AV CP FG RV RG AV BV LEK LEK 3

For Home Owners Operation and maintenance Operation and maintenance General After installing, check with the installer that the installation is in good condition. Allow the installer to show controls and functions so that you are fully aware about how to use and maintain the installation. Check that the water pressure is correct; air may remain in the system after installing. This is why bleeding and pressure checks should be carried out again. Operation Electrical output is controlled externally by the heat pump. This means that the electrical output is connected and disconnected by the additional heater. Safety valve A safety valve that is installed in the heating system, in connection with the closed expansion system, must be exercised regularly, approximately 4 times per year to maintain the safety function or according to national regulations. Venting Regularly check that there is water in the system. Air can remain in the system after installation and the radiators and boiler should be bled again. After bleeding, the pressure must be checked and water topped up if necessary. Draining If draining the system of water, the electric module must be switched off to prevent damaging the immersion heater s electric coils. Actions in the event of freeze risk In the event of extreme cold, no part of the heating system must be switched off, there is a risk of frost damage. If a part of the heating system is thought to be frozen, contact the installer. If the heating system must be switched off for a long period of time, drain the water and ensure that the immersion heater cannot be started. 4

For the Installer General information for the installer General information for the installer Function Area of use for NIBE immersion heater is in combination with NIBE ground source heat pumps and air/water heat pumps. When the heating demand is greater then heat pump's capacity, the immersion heater connects automatically as additional heat. The electrical equipment is adapted to the heat pump's function. contains overheat protection and three contactors to control the three power stages 4, 7 and 15 kw. For best function the power should be binary controlled, that is 4, 7, 11, 15, 19, 22 and 26 kw. If there is no operating voltage from the heat pump, the largest power stage can be force controlled via thermostat. See the wiring diagram. Pipe installation The pipe installation must be carried out in accordance with applicable standards. Electrical installation must be installed via an isolator switch with a minimum breaking gap of 3 mm. NOTE Electrical installation and service must be carried out under the supervision of a qualified electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. Power supply The electric heater must be supplied with 400 V 3VAC 50Hz fused 3x40A The cable for the operational supply must be 5 x 1,5 mm 2. NOTE Reset the temperature limiter, it may have tripped during transport. NOTE In the event of any servicing all electrical supplies must be checked and disconnected. The immersion heater can be supplied with voltage from connected heat pump. LEK Draining The system is most easily drained by installing a drain valve to the lowest point of the piping. Draining via such a valve leaves a small amount of water in the immersion heater, which is therefore drained via drain connection (71). If the unit is normally drained via the immersion heater's drain connection, install a suitable drain valve. The immersion heater must be installed standing (see image above). An area of 500 mm is required in front of the immersion heater for service work. If this is not possible, detachable connections should be used. Circulation pump must be used to ensure the flow over the immersion heater. If the heating system s valves can close the circulation completely, a by-pass must be installed to prevent the flow through the immersion heater from being stopped. When the unit is off, an approved safety valve must be installed as well as a pressure expansion vessel. The safety valves must be checked about four times a year. This is done by quickly opening and closing the valves. The pressure is reset by filling with water. 5

For the Installer Installation alternative Installation alternative Components AV Shut-off valve BV Non-return valve ELK Immersion heater EXP Expansion vessel FG Flow sensor HR Auxiliary relay KB Brine RG Return temperature sensor RV Control valve SF Particle filter SÄV Safety valve UG Outdoor temperature sensor VBP Circulation pump VVG Hot water temperature sensor VXV Three way valve, VST 11/VST 20 AA5 BP6 BT1 BT6 BT25 BT71 CMX CP10 EB1 EB2 EB100 EP EP14 EP15 FL2 FL3 FL1X GP10 HQ1X KA1 QM11 QM2X QM30-QM59 QN10 RMXX RN11 XD1 XL27-XL28 Accessory card Pressure gauge Outdoor temperature sensor Temperature sensor, hot water charging Temperature sensor, heating medium flow, external Temperature sensor, heating medium return, external Expansion vessel Accumulator tank Immersion heater Immersion heater Heat pump Collector, brine side Cooling module A Cooling module B Safety valve, heating medium Safety valve, brine Safety valve Circulation pump, heating medium Particle filter Auxiliary relay, immersion heater filler valve Venting valve Shut-off valve Reversing valve, hot water/heating Non-return valve Trim valve Connection box Connection, filling brine 6

A B A B 50.0 C Varmvattentemperatur 1.0 13.43 I II For the Installer Installation alternative FIGHTER 1320/1330 and F1330 SÄV EXP VBP3 FG AV RV HR BV RG UG VXV RV BV AV KB-ut B SF AV VVG EXP AV P SF KB-in A F1330 SÄV RV BV HR VPB FIGHTER 1320/1330 / F1330 prioritises loading of hot water with half the output (heat pump module B) via a reversing valve. When the hot water heater/accumulator tank is fully charged, the reversing valve switches to the heating circuit. When there is a heat demand, module A starts first. For larger heating demands, module B is also started. FIGHTER 1320/1330 / F1330 connects in steps when the energy requirement exceeds the heat pump capacity. If HWH/ACC is fitted with an immersion heater and a junction box the "Extra hot water" function can be used. A by-pass contactor is recommended. Menu settings 1. Select Electric in menu 9.1.8 - "Additive". 2. Select Binary in menu 6.2.1 - "Immersionheater type". 3. Select 2 in menu 6.2.2 - "Immersionheatrelays". 4. Select "1" in menu 6.2.3 - "Steps at 2h delay", if a restriction of the electrical power for 5 kw within 2 hours from start-up is required. 5. Select "Auto" operating mode in order for the electrical addition to be permitted to start. Check the max. output setting on knob (101), in FIGHTER 1320/1330 / F1330. See the appropriate Installation and Maintenance Instructions for FIGHTER 1320/1330 / F1330 for more information. 7

For the Installer Installation alternative Electrical connection FIGHTER 1320/1330 Without thermostat, 2 active electrical steps 11 kw immersion heater step active. FIGHTER FIGHTER 1320/1330 X6 8 9 10 11 13 14 15 16 X9 1 2 3 4 N L1 L2 L3 PE 11 10 35 T With thermostat, 3 active electrical steps 26 kw immersion heater step active. 15 kw immersion heater step active in emergency mode. FIGHTER FIGHTER 1320/1330 X6 8 9 10 11 13 14 15 16 X9 1 2 3 4 N L1 L2 L3 PE 11 10 35 T NOTE The thermostat (35) must be adjusted so that the system's highest permitted temperature is not exceeded. The adjustment must not be so great that it limits the power. 8

For the Installer Installation alternative Electrical connection F1330 Without thermostat, 2 active electrical steps 11 kw immersion heater step active. F1330 X6 13 14 15 16 17 18 19 20 X9 1 2 3 4 N L1 L2 L3 PE 11 10 35 T With thermostat, 3 active electrical steps 26 kw immersion heater step active. 15 kw immersion heater step active in emergency mode. F1330 X6 13 14 15 16 17 18 19 20 X9 1 2 3 4 N L1 L2 L3 PE 11 10 35 T NOTE The thermostat (35) must be adjusted so that the temperature above the system's highest permitted temperature is not exceeded. 9

For the Installer Installation alternative F1345 -EB1 -FL10 -CM5 -EB1 -QM42 -QM43 -RN11 -GP10 -RM42 -EB100-BT25 -EB100-BT71 -BP6 P -QM21 -FL3 -CM3 -QM33 -EB100 -BT1 -XL27 -XL28 -QM34 -FL -QM53 -EB100 -HQ13 -EP15 -RM13 -QM57 -EB100 -QN10 -CP10 -EP -QM52 -RM11 -FL11 -QM51 -HQ -QM50 -RM10 -EP14 -HQ15 -QM56 -FL14 -RM -QM55 -HQ14 -QM54 -FL13 -AA5 -EB100 -BT6 -XD1 -KA1 -EB2 -QM11 -FL2 -CM1 -QM20 Module EP14 prioritises hot water charging via a reversing valve. When the hot water heater/accumulator tank is fully charged, the reversing valve switches to the heating circuit. The heat pump is controlled by an outdoor sensor combined with the flow line sensor which must be placed on the main pipe to the radiators. is connected automatically when the energy requirement exceeds the heat pump capacity. Menu settings 1. Set start diff additional heat and diff. between additional steps in menu 4.9.3 - degree minute setting. 2. Set whether there should be binary control or not, max step and fuse size in menu 5.1. - step controlled add. heat. See the Installer manual for F1345 for more information. 10

For the Installer Installation alternative Electrical connection F1345 Without thermostat, 3 active electrical steps 26 kw immersion heater step active. F1345 X9 PE 35 6 5 L3 T 4 3 2 1 X3 L2 L1 N 4 11 9 8 7 3 2 6 5 4 3 2 1 X2 1 10 With thermostat, 3 active electrical steps 26 kw immersion heater step active. 15 kw immersion heater step active in emergency mode. F1345 3 2 1 6 5 X4 X9 PE L3 35 T 4 3 2 1 X3 L2 L1 N 4 11 9 8 7 3 2 6 5 4 3 2 1 X2 1 10 NOTE The thermostat (35) must be adjusted so that the temperature above the system's highest permitted temperature is not exceeded. 11

Miscellaneous Electrical circuit diagram Electrical circuit diagram

Miscellaneous Technical specifications Technical specifications Dimensions 565 30 350 65 90 140 140 60 245 13

Miscellaneous Technical specifications Component positions 95 81 35 6 70 10 11 7 13 1 9 71 78 LEK List of components 1 Immersion heater (-R1) 6 Overheat protection (-B1) 7 Miniature circuit-breaker 9 Terminal block (-X9) 10 Contactor (-K1) 11 Contactor (-K2) Contactor (-K3) 13 Contactor (-K4) 35 Emergency mode thermostat (-B2) 70 Connection, flow line, G 40 71 Connection, return line, G 40 78 Cable grommet 81 Venting 95 Sign, serial number 14

Miscellaneous Technical specifications Technical specifications IP 44 Height Width Depth Weight Volume Supply voltage Output immersion heater Fuse immersion heater Enclosure class Max permitted pressure in the boiler Min flow Material immersion heater Material tube Part No. 560 mm 240 mm 135 mm 15 kg 4.5 litres 400 V 3NAC 50Hz 26 kw 40 A IP 44 0.7 MPa (7 bar) 00 l/h SIS 2333 EN 1.4301 SIS 2333 EN 1.4301 067 074 15

Miscellaneous Dealing with malfunctions Dealing with malfunctions In the event of a malfunction or disruption to normal operation, first check the points below: Low room temperature Circuit or main MCB tripped. Possible earth circuit-breaker tripped. The overheating protection has tripped. If the overheating protection has tripped, the function of the system s circulation pumps and valves must be checked. Reset by pressing in the button on the overheating protection, when the temperature has dropped below 80 C. Circulation pump stopped. Air in boiler or system. The pressure is to low in the expansion vessel. The load monitor or some external control unit may have blocked the power output. NOTE Work behind panels secured by screws may only be carried out by a qualified installation engineer. 16

2352 AT KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at CH NIBE Wärmetechnik AG, Winterthurerstrasse 710, CH-8247 Flurlingen Tel: (52) 647 00 30 Fax: (52) 647 00 31 E-mail: info@nibe.ch www.nibe.ch CZ Druzstevni zavody Drazice s.r.o, Drazice 69, CZ - 294 71 Benatky nad Jizerou Tel: +420 326 373 801 Fax: +420 326 373 803 E-mail: nibe@nibe.cz www.nibe.cz DE NIBE Systemtechnik GmbH, Am Reiherpfahl 3, 29223 Celle Tel: 05141/7546-0 Fax: 05141/7546-99 E-mail: info@nibe.de www.nibe.de DK Vølund Varmeteknik A/S, Member of the Nibe Group, Brogårdsvej 7, 6920 Videbæk Tel: 97 17 20 33 Fax: 97 17 29 33 E-mail: info@volundvt.dk www.volundvt.dk FI NIBE Energy Systems OY, Juurakkotie 3, 01510 Vantaa Puh: 09-274 697 0 Fax: 09-274 697 40 E-mail: info@nibe.fi www.nibe.fi FR AIT France, 10 rue des Moines, 67500 Haguenau Tel : 03 88 06 24 10 Fax : 03 88 06 90 15 E-mail: info@nibe.fr www.nibe.fr GB NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 00 Fax: 0845 095 01 E-mail: info@nibe.co.uk www.nibe.co.uk NL NIBE Energietechniek B.V., Postbus 2, NL-4797 ZG WILLEMSTAD (NB) Tel: 0168 477722 Fax: 0168 476998 E-mail: info@nibenl.nl www.nibenl.nl NO ABK AS, Brobekkveien 80, 0582 Oslo, Postadresse: Postboks 64 Vollebekk, 0516 Oslo Tel. sentralbord: +47 02320 E-mail: post@abkklima.no www.nibeenergysystems.no PL NIBE-BIAWAR Sp. z o. o. Aleja Jana Pawła II 57, 15-703 BIAŁYSTOK Tel: 085 662 84 90 Fax: 085 662 84 14 E-mail: sekretariat@biawar.com.pl www.biawar.com.pl RU "EVAN" 17, per. Boynovskiy, Nizhny Novgorod Tel./fax +7 831 419 57 06 E-mail: info@evan.ru www.nibe-evan.ru NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd Tel: +46-(0)433-73 000 Fax: +46-(0)433-73 190 E-mail: info@nibe.se www.nibe.eu