System TFEasyline serwisowej MVC lini kablowej SN TF Cable Easyline service MVC system for medium voltage line

Similar documents
System TF Easyline serwisowej MVC lini kablowej SN TF Cable Easyline service MVC system for medium voltage line

More than Just a Cable Supplier

More than Just a Cable Supplier

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

MINING CABLES POWER YOUR MINE WITH TF KABLE

Üntel is ready for CPR

fire resistant cables

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

DNVGL-CP-0401 Edition February 2016

Lloyd s Register Type Approval System Test Specification Number 3

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

DNVGL-CP-0399 Edition March 2016

The Quality Connection. BETAflam Fire Resistant Safety Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

THE TRUE FIRE SURVIVAL CABLE

INTERNATIONAL STANDARD

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

Overmoulded Cable Assembly Selector Guide

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Cables and cabling solutions for residential buildings: safety, comfort and environmental-friendliness

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Comtran Cable. Hub-LINK Cables for Transit Applications

Traction Cable Radox 3 GKW

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

speed pipe indoor system. Secure indoor networks.

Cable technology for highest safety requirements

Energy Division. CSJT MV cold shrinkable joint for 3-core cables with resin encapsulation

SAFE CABLING SYSTEMS IN TUNNELS UNDER FIRE

A cast iron case for our modular motors: High-voltage motors H-compact PLUS

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

Heat-Shrinkable Termination System for Cables up to 36 kv

PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. COMPANY PROFILE 2015

Solder joints point to point. Technology day AB Tehnik 2016 Technology Day AB Tehnik

On Electromagnetic Compatibility

English. Heating with logs & wood pellets 20-40

BS /1000V XLPE Insulation LSZH Sheath Cables

Custom Engineered Design. English

The Quality Connection. Cable fire protection Flammability tests on ship and offshore cables

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

Condensation drying for industry and trade

YOUR GUIDE TO UNDERSTANDING CPR

Nuclear Power Plant LSZH Cable Overview

PRODUCT CATALOGUE Norröna

WSD 1734 Issue 4 Automotive 150 C Rated MPCB Cable Specification

DNVGL-CP-0402 Edition February 2016

INTERNATIONAL STANDARD

Flexible Power Cable DLO

Important Safety Notice

Log fired heating system

FieldLink Cable solutions for Automation & Drives

Welcome to Brugg s world

Construction Products Regulation (CPR) and BS 6701

Flues and chimney systems

CABLES FOR ALARM AND SAFETY SYSTEMS

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

Tether and Umbilical Cables for Remotely Operated Vehicles

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

Photovoltaic Cables EN H1Z2Z2-K

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

English. Heating with logs & wood pellets 20-40

Cablosam Tapes for Fire-Resistant Cables

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

For more information on Tarkett go to

ETSI TS V1.2.1 ( )

The Quality Connection. BETAflam safety cables for highest demands

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

GAS CONTROL SYSTEMS SOLUTIONS OVERVIEW Manifold Systems Control Panels HP/UHP Regulators Pressure Gauges Valves&Fittings

CATEGORY 6A FTP RJ45 SOLUTION

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

A safe journey with Dräger CRUISE CATALOGUE

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

OIL & GAS INDUSTRY OTHER INDUSTRIES

User Manual. GPD 3000 e. gas detector

BT Cables Technical Seminar CIBSE South Wales Region. Nov 17

Fiber Distribution Box

PRODUCT CATALOG.

Reliable solutions for electrified railway systems

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

tesa tape Providing Adhesive Tape Solutions for Industry

Single core cables with reduced wall thickness

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Low Voltage Catalogue_Final ai 11/8/09 11:37:27 AM BICC 1 BICC Final Brochure-NEW.indd 1 7/5/10 3:02 PM

Catalogue Telecommunication Cables INTRODUCCIÓN

Special Provision No. 683S28 December 2017

Transportation. Distribution

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

water to water heat pumps

Efficient and economical solutions for water heating and air conditioning - Wieland Thermal Solutions at Mostra Convegno

Transcription:

System TFEasyline serwisowej MVC lini kablowej SN TF Cable Easyline service MVC system for medium voltage line

Leading producer of cables and cable systems The TELE-FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years. A stable development strategy based on full diversification of outlets enabled the strenghtening of the position of our company among world s leading cable companies with significant development potential. Services and products provided by TF Kable have numerous applications in the most important industry sectors they include more than 25,000 proven standard constructions. Furthermore, they include specialist assortment tailored to the individual needs of business partners. Additionally, our production facilities (in Poland, Serbia and Ukraine), the Bukowno-Poland recycling plant and commercial companies (responsible for the georegional distribution of products) demonstrate a significant development potential. This is also true in the case of our modern fire test laboratory in Krakow-Wielicka plant, which performs several hundred flammability pre-tests annually, and a laboratory of high and extra high voltages in Bydgoszcz. As a result of implementation of our growth strategy, in August 2017 TFKable Group acquired JDR Cable Systems Ltd, the leading manufacturer of submarine umbilicals and power cables to the global offshore energy industry. In the world s harshest environments and big water depths., JDR s world-leading products and services bring power and control to offshore oil, gas and renewable energy systems.

Experience and competence of the TELE-FONIKA Kable Group global relations Kraków Wielicka plant it produces cables and wires with voltage ranging from 1kV to 30kV, including rubber insulation, used in the extractive industry and wind farms; halogen-free cables and conductors (installed inside buildings); and signaling and control cables for special applications Fire Test Laboratory in the Krakow-Wielicka production plant it is equipped with apparatus that enables to conduct research ranging from basic tests of flame spreading on individual samples to flame spreading tests on bundles. Furthermore, it is equipped for testing density of emitted fumes and emission of corrosive gases Kraków Bieżanów plant production of overhead Laboratory of High and Extreme Voltages lines from alloyed aluminum, silver plated in the production plant in Bydgoszcz copperconductors for railway traction networks, made equipped with 4 Faraday cages (three for routine on robotic technology lines testing and one for cables and cable systems testing) JDR Cable Systems Ltd. Littleport (UK) Bydgoszcz plant the largest production center for medium, high and extra high voltage cables in Europe along with a stroke generator and its own research field for qualification tests with 500kV testing systems and 5000A heating transformer sets TF Cable Americas Bolingbrook (USA) JDR Cable Systems Ltd. Hartlepool (UK) Copper Cable Company Ltd. Leicestershire (UK) TELE-FONIKA Kable S.A. Myślenice (Poland) TELE-FONIKA Kable Central Europe GmbH Hilden (Germany) Myślenice plant production of copper and fiber optic telecommunication cables, computer cables and car cables Zajecar plant (Serbia) production of low and medium voltage cables, signaling and control cables, telecommunication cables, as well as halogen-free cables and wires Czernihov plant (Ukraine) production of nonflammable (N)HXH and N2XH cables, self-supporting AsXSn overhead cables, aluminum and copper wires JDR Cable Systems As a result of acquiring JDR Cable Systems Limited, TFKable has expanded its assets with two UK production Facilities. JDR manufactures submarine power cables as well as subsea umbilical cables consisting of components for power distribution, data transfer, monitoring and remote control, of offshore facilities. Additionally, our sales portfolio has been extended by offshore installation and maintenance services, located in JDR s service centres in the United States, UK, ensuring constant support for our business partners. UAB TELE-FONIKA Baltic Kaunas (Lithuania) up to 1kV, including assembly wires Bukowno-Poland plant (recycling of cable waste) TELE-FONIKA Kable S.A. (Branch) Dubai (UAE) it has the recycling capacity of approx. 10 thousand tons of cable waste per year. This allows for the recovery of fractions from individual materials with purity of over 99.5% JDR Cable Systems Ltd. (Sales Representative) United States, UK

TFEasyline MVC is a mobile medium voltage cable line constituting a complex solution from TFKable Group for professional power industry Basic Applications: Rapid power restoring on damaged overhead lines Temporary power supply to customers Repair works of power infrastructure The solution minimizes duration of power outage during scheduled repairs or during breakdowns of electrical power network. The above mentioned equipment consists of: 3-core cable ended with connector terminations, layed on dedicated cable drum metallic drum divided on special sections multifunctional cable trailer 1-core cables (bridges) which can be used to connect 3-core cable with overhead line or transformer switching module cable equipment (straight and angular connector terminations, outdoor terminations, cable joints) extra equipment (connection boxes, tracks, rollers, warning elements) guarantees safety and easy work of medium voltage power line

3-core power cable Cu/HEPR/CWS/PVC 1-core power cable Cu/HEPR/CWS/PVC DESCRIPTION CHARACTERISTICS DESCRIPTION CHARACTERISTICS Cable type Cu/HEPR/CWS/PVC Cable type Cu/HEPR/CWS/PVC Insulation material HEPR Insulation material HEPR Type of outer sheat PVC Type of outer sheat PVC Nominal voltage Uo/U 12/20 kv Nominal voltage Uo/U 12/20 kv Cross-sectional of main conductor 3x35 mm² Cross-sectional of main conductor 1x35 mm² Cross-sectional of metallic screen 16 mm² Cross-sectional of metallic screen 16 mm² Type of conductor 5 class Type of conductor 5 class Cable diameter 60 mm Cable diameter 28 mm Bending radius 0,7 m Bending radius 0,45 m AC proof voltage Current rating in normal conditions 42 kv AC/ 5 min <180 A Three sections of 1-core cables (bridges) ended with straight connector terminations and angular connector terminations Set no. 1 Temperature range From -10ºC do +50ºC (±5ºC) Fire resistance PE-EN 60332-3-23 UV resistance PN-HD 605; 2.4.16 Type test standard PN-HD 620 S2:10C Cable adapter to multiple rewind 50 Six sections of 1-core cables (bridges) ended with straight connector terminations and outdoor terminations Length of 1-core cable Protection 1-core cables on storage time Set no. 2 15 m Round plastic boxes Cable both sides ended with straight connector terminations on A250A interface Length on drum + < 800m

Cable drum DESCRIPTION Drum diameter Drum material Drum structure Protection of cable on drum CHARACTERISTICS 2500mm Powder painted construction steel Sectional YES Cable equipment straight connector termination DS250 angular connector termination DE250 outdoor termination CHE-F Line equipment switching module Aproximate dimensions of module B 800mm/L 1200mm/H 1000mm Weight of module : about 80 kg cable joints CVS250 Electrical characteristics of cable fittings DESCRIPTION Maximal voltage (Um) Impuls voltage (Uimp) Current rating Overload current (<8 hours) Short circuit current (1sek) CHARACTERISTICS 24 kv 125 kv 250 A 300 A <12,5 ka

An exemplary arrangement of elements of a mobile line TFEASYLINE MVC Advantages of the medium voltage cable service line: Easy and quick installation in any outdoor conditions High immunity to multiple reeling and unreeling main cable and 1-core cables (bridges) Improved immunity of cable equipment to switch on and off Completely compatibility with standard PN-HD 620S2:10C B category vertical flame spreading, according to PN-E 60332-2-23 Eca class of reaction to fire, according to requiments of PN-EN 50575 No need to apply for official permissions for line reeling- this significantly reduce the time of restoring power/failure repair Switching module H=1,1m D=1,3m, Width=0,8m

TELE-FONIKA Kable met 100% of the CPR requirements We provide reliability through demanded QUALITY The only modern Polish Fire Test Laboratory that allows more than three hundred tests of flammability for cables and wires annually Fully automatic Im320 E mixer designed for the production of rubber blends Implementation of the full range of products in E ca, D ca, C ca and B2 ca classes Assurance of control and measurement apparatus for several hundred flammability tests in the Fire Test Laboratory at the Production Plant in Krakow. Performing further tests of the examined construction in order to ensure their notification by the authorized certification body the Institute of Building Technology in Warsaw Implementation of new labels in accordance with the requirements of the CPR Directive Marking of cables and wires intended for building on the coating Limitation of the use of PVC materials for higher classes of products Compliance with the regulations of the Declaration of Performance (DoP) Positive results of the required audits ERCONET Media Management System Usage of 80% of waste heat from of the production process that enables the analysis and effective the operation of compressors management of energy media for hot water heating Implementation of uniform distribution Modern Cable Waste Recycling Plant with the processing power of any cable waste Modern Quality Control Laboratories equipped with specialized control and measurement devices Reduction of pollutant emissions through the modernization of boiler houses in production plants Specialization of production facilities that allows for effective production planning of TELE-FONIKA cables and wires in accordance with classes of reactions to fire and coexistence factors, including smoke generation, corrosive gases and flaming drops their categorization according to the application and their use in buildings, i.e. commercial, civil and industrial in compliance with fire safety regulations We have established a team of specialists, who will provide you with all necessary information and answer any questions related to the changes resulting from the CPR regulation CPR@tfkable.com

Sustainable development through values 8 production plants, including dedicated research units, namely the Fire Test Laboratory and the High and Extra High Voltage Laboratory 6 trading companies and sales and maintenance units in 8 countries > 3,5 thousand skilled workers > 25 thousand inspected and provided cable and wire constructions Implementation of projects for recipients in over 80 countries No. 1 the Polish market, based on the production technology having been developed since the early 20th century. > 500 production lines The production potential enhanced by high-end production of submarine systems and maintenance and installation services for the petroleum, gas and renewable energy industries Innovative environmentalfriendly technologies, including the Cable Waste Recycling Plant Myślenice plant: Bieżanów plant: Kraków plant: Bydgoszcz plant: Sales Department: 32-400 Myślenice, ul. Hipolita Cegielskiego 1, tel.: +12 372 71 00, 30-841 Kraków, ul. Nad Drwiną 20, tel.: +12 651 41 95, 30-663 Kraków, ul. Wielicka 114, tel.: +12 652 50 00, 85-957 Bydgoszcz, ul. Fordońska 152, tel.: +52 364 32 10, T: +48 52 364 32 97, info@tfkable.com www.tfkable.com energy@tfkable.com