Intelligent Earliest Warning Aspirating Fire Detector

Similar documents
-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

HART XL High Sensitivity Smoke Detection

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

HART XL High Sensitivity Smoke Detection

Why Hart XL Aspirating Smoke Detection?

FAAST. Fire Alarm Aspirating Sensing Technology

Aspir A ation spir P R O D U C T S

Aspirated Smoke Detectors

ID50series. intelligent fire alarm panels

Flexible Air-sampling Smoke Detection

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

The World's No. 1 Brand of Air-sampling Smoke Detector

EARLIEST SMOKE DETECTION WITH MAXIMUM FLEXIBILITY

Buys Time. Aspirating Smoke Detection

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

The World's No. 1 Brand of Aspirating Smoke Detector

FAAST. Fire Alarm Aspirating Sensing Technology

Video Imaging Detection Systems

intelligent fire alarm ID60series panels

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

and Aspirating Smoke Detection

FAAST PRODUCT RANGE Aspirating Smoke Detection

Aspiration Detection.

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

L CONNECTION NETWORK Commercial Controls

Buys Time. Aspirating Smoke Detection

The World s No. 1 Brand of Aspirating Smoke Detection

VESDA VLP. Engineering Specification

Early Warning Fire Detection Engineering

ID3000 intelligent. fire alarm panel

VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

LaserFOCUS VLF-250 Engineering Specification

Open-area Smoke Imaging Detection (OSID)

LEARNING SPECIAL HAZARD DETECTION TYPES

EXTINGUISHING SYSTEM DETECTION AND CONTROL

Different types of Fire Alarm System

FAAST. Fire Alarm Aspiration Sensing Technology

Building Technologies

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

CO/Smoke Detection PRODUCTS. Accessories Conventional Detectors and Modules

Open-area Smoke Imaging Detection (OSID)

TrueAlarm Analog Sensing

Desigo Fire Safety intelligent detectors for complete safety

ID3000 intelligent. fire alarm panel

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

Open-area Smoke Imaging Detection (OSID)

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Aspirating smoke detection

Section PERIMETER SECURITY SYSTEMS

SPEED, STABILITY, & RELIABILITY N EW! IntelliQuad TM PLUS Combination Smoke and Carbon Monoxide (CO) Detector

The World's No. 1 Brand of Aspirating Smoke Detector

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

High-precision aspirating smoke detectors for every requirement.

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

The Next Generation of VESDA Aspirating Smoke Detection Technology

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

For Complete Fire and Gas Solutions

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Open-area Smoke Imaging Detection (OSID)

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Ammonia Detection System Codes and Design Specifications

1.1 SCOPE 1.2 APPROVALS. A. The Aspirating Smoke Detector shall be tested, approved and/or listed by: 1.3 CODE, STANDARDS, AND REGULATION

Consultant Specification AGILE Wireless Fire Detection System

DS7400Xi Addressable Control/ Communicator

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Aspiration Systems for Smoke Detection

Advanced FireAlarm Panel 1-4Loop

Fire Detection System: An Overview

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

SPC-56 SHORT PLANT.

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Aspirating Smoke Detection

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Feature Summary. I. System

Advanced Fire Alarm Systems Training Program Outline (5 Day)

Aspirating Smoke Detection (ASD) Systems Fire Detection

Integrating Fire and Gas Safety with Process Control Systems:

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

End To End Optical Beam Smoke Detector. Additional Information

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

MINERVA MZX125 Digital Addressable Fire Detection System

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

ID2000. intelligent fire alarm panel

Industrial Grade Gas Detection

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

ONYXWORKS AND FIRSTVISION. Version 4

SALES SUPPORT DOCUMENT

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Keywords: VEWFD; Smoke detection; Smoke production; In-situ testing.

Section 8 System Operation

Transcription:

I N T E L L I G E N T A S P I R A T I N G CSFM MEA ISO 9001 Intelligent Aspirating Fire Detector Intelligent Earliest Warning Aspirating Fire Detector F I R E D E T E C T I O N

Before Fire Before Downtime New Advanced Detection Technology I ntelligent Aspirating Fire Detection There Is Fire... The new advanced intelligent CCD (Cloud Chamber Detection) technology from Protec combined the benefits of spot, laser, and cloud chamber detection into a single detector, and can detect before smoke. CCD provides paralleled technology which only detects combustion making it immune to false alarms from dust, dirt, temperature, and humidity which plague other early warning air sampling and spot detectors. The introduction of CCD technology now allows for an aspirating system to be ultra sensitive while eliminating the nuisance alarms associated with other detection technologies. Single Point Maintenance - Lower Cost The Most Sensitive Detector Available No False Alarms Four Stages of Fire Full Spectrum Detection ProSeries - Detection in Every Stage of Fire 1 2 3 4 Incipient, Smoke Flame Heat Before any Smoke Early Warning Laser Conventional Spot Detects in All Four Stages of Fire In addition to the advanced detection abilities when using CCD technology, single point maintenance allows for easily servicing the detection system. By eliminating the mandated yearly testing of each ceiling mounted spot detector (NFPA 72), the need for expensive lifts and hours of labor have been reduced to a few quick and simple tests performed at the detector. % Obscuration (obs/ft)* 100 90 80 70 60 50 40 30 20 10 0 UV and IR Sprinkler Time/Fire Propagation - Decreases response time before heat stage Now available with optional Gas Detectors: Ammonia Detection Carbon Monoxide Detection Combustible Gases Detection Single Point Maintenance 11

Standard Enhanced LCD Display with Custom Text High Pressure User Friendly Display ProSeries detectors may now be equipped with the industry s largest and most versatile LCD display. This new multifunction display allows users to easily identify and respond to an early warning alarm in addition to receiving detailed instructions via the display. 2nd July 2007, 23:51 LCD Display Features Program Display Troubleshoot Network Tower Two, 28th Floor Computer Room 2A, Subfloor Pipe Number 1 40% Current Alarms Section 4 Air Handlers Hot Row 6 - Report Alarm to Maintenance x320 Fire 1 - Call Supervisor Cell: 704-821-7920 Fire 2 - Evacuate All Personnel Fire 3 - Suppression Release 1 2 3 Custom Text: 1. Pin-point the detector location. 2. Identify each zone. 3. Provide custom instructions for your personnel to follow at each level of alarm. Real Time Graph Gain 7 100% Info Silence Reset Exit Menu 90% _ F3 Simplified Programming: The large easy to read LCD display allows for quick navigation through all of the unit s functions. 70% 50% _ F2 _ F1 20% _ Pre Analytical Tools: Analyze live Real Time and Historic Graphs to determine the growth or decline of an immediate fire threat. 0% Remote Display, Programmer And Network Hub A Remote Display or any unit with a display on a detector network, now allows you too easily Program, View, Display Historic Graph and Event Logs, Troubleshoot, and provide Alarm Notification for any unit on the network. The multifunction LCD display features easy to navigate menus and customizable text for naming detectors, zones, alarm levels and even specific instructions for personnel to follow. Remote Display P rogram Detectors View Historic Graph Real Time Graph Review Event Logs Troubleshoot Detectors Review Detector Statistics Alarm Notification Zone Identification Alarm Procedures Detector Network 12

Detector Network PC Network Internet Network Expanded Networking Abilities Multiple Detector Networking Options ProSeries detectors provide several networking options. From a simple RS485 Peer to Peer network between detectors using a detector LCD display or ProRemote as the network hub, to software driven networks using TCP/IP for access through any LAN, WAN, or internet connection. Peer to Peer Detector Networking Built-In RS485 Networking Simply use a shielded Belden 9841 type cable to network the units together via the internal RS485 connections. Network Simplicity Any unit with an LCD display, or a Remote Display, may be used to Program, View, Display Historic Graph and Event Logs, Troubleshoot, and provide Alarm Notification for any unit on the network. Remote Display A Remote Display may be placed in areas which are populated after hours such as guard stations or office areas. Remote Display Complimentary CirrusPro Networking Software for PC Available at no cost, CirrusPro Networking Software will allow you to easily Program, View, Display Historic Graph and Event Logs, or Troubleshoot any detector on the network via a PC. Simply connect a PC running CirrusPro software to any detector on a Peer to Peer network. 13

Peer to Peer RS232 Networking Solutions TCP/IP HLI Networking Software Remotely monitor a detector network using ProNet High Level Interface software via an internet, LAN, or WAN connection. Detailed graphic maps of an area are used to isolate alarms and display specific zone information. You may also Program, View Detector Status, Display Historic Graphs and Event Logs, as well as Troubleshoot any detector on the network. View entire detector network tree remotely via TCP/IP View status of any detector on network in any hazard Receive real time notification of any detector zone in alarm ProNet Realtime Remote Network Monitoring Software TCP/IP Connection TCP/IP module may be installed in any unit on the network Integrated TCP/IP Networking The ProSeries TCP/IP Interface Module works with ProNet software to access a detector network through any Internet, LAN, or WAN connection. This easy to install module is simply mounted inside a detector and is configured using the CirrusPro software. Any detector on the network, with or without a display, may act as the TCP/IP detector hub. 14

Industrial High Ceilings Extreme Hazards Difficult Applications When All Else Fails... Dirty Dusty Humid Gases High Ceilings Vapors High Airflow Chemicals High Temperatures Industrial and harsh environmental applications are traditionally difficult to protect with conventional detection methods. Exposure to dirt, dust, humidity and corrosive conditions can cause other aspirating fire detectors to fail in offering the reliable and cost effective solution that these "challenging" environments require. Accelerated wear on other systems from harsh conditions increases both maintenance of the installed system and the occurrence of false alarms. This creates a significantly more costly system to maintain, and false alarms caused by inappropriate detectors can disrupt normal business operations. MEA ISO 9001 The ProX4's advanced CCD technology is TRULY immune to dust, dirt, and pollutants that can cause false alarms in other detectors. The ProX4 can also detect at ceiling heights of up to 125', in winds up to 67MPH, protect more area than any other detector on the market, and has the largest aspirating pipe network available. Combined with single point maintenance, the ProX4 offers the greatest versatility and reliability at the lowest cost for your challenging environment. -Industrial The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments 15

ProX4 Zone 1 Zone 2 Zone 3 Zone 4 Computer Room 4 N maaul lo Nor F tsperation ProX4 Early Warning Harsh and Difficult Environments Cost Effective The Industrial Solution Behind The Technology PROTECTING INDUSTRIAL ENVIRONMENTS SINCE 1972 No False Alarms Unaffected by Stratification Lower Maintenance Costs Single Point Maintenance Ceiling Heights up to 125ft. 43,200 sq.ft. of Coverage Extreme Temperatures Air samples drawn into a ProSeries detector are passed through a CCD chamber for analysis. The CCD chamber amplifies the invisible.0025µm particles released during the overheating stage of a fire, prior to any smoke. These amplified particulate are directly proportional to the level of the fire event, and are detected via microscopic obscuration using a high output diode. Other foreign airborne objects such as dirt, dust and pollutants are inherently too large and in too few quantity to be detected. These foreign objects do not affect the ability of the CCD to identify the much smaller combustion particles. This in turn eliminates false alarms associated with other detection methods which use other technologies. For more information, please view the ProSeries technology video on our website, www.safefiredetection.com Typical ProSeries Engineered System: Sample Point Detector analyses air samples for combustion particulate To Fire Alarm Control Panel, Addressable Module, or ProSeries 485 Network Uninterrupted Power Supply with 24 hour battery backup An engineered sample pipe network uses a high pressure aspirator to draw air samples from the hazard back to the detector for analysis 16