THE TOWNSHIP OF CRANBURY

Similar documents
Flemington Borough Fire Safety 38 Park Ave Flemington, NJ 08822

Township of Maplewood

Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification

Requirements for Smoke Detector / Carbon Monoxide/ Fire Extinguisher Certification

Certificate of Inspection CHECKLIST

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

Certificate of Continued Occupancy Residential Application

Large Family Daycare Guideline

Smoke Alarm and Carbon Monoxide Alarm Installation

Rental Housing Inspection Guide

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

Smoke & Carbon Monoxide

Smoke Alarms and Carbon Monoxide Alarms

APPLICATION FOR Large Family Day Care Permit

SMOKE ALARMS City of Grand Rapids Building Safety Division

Melrose Fire Department

THE GENERAL ASSEMBLY OF PENNSYLVANIA SENATE BILL

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

Short-Term & Accessory Short-Term Rental Safety Certification

Residential-based Care Facility R-4 Guideline

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

CHILD CARE CENTER INSPECTION CHECKLIST 06C

Family Foster Home Fire Safety Evaluation Checklist Instructions

Denver Fire Department Fire Prevention Division

Residential Care Facilities Requirements

Apartment Fire & Safety Inspection. City of Guadalupe

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

Fire and Life Safety GUIDE

FIRE PREVENTION STANDARDS

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Short Term Accommodations Fire Code Requirements

Residential Large Family Daycare Facilities

For additional information regarding R-3.1 residential care facilities please contact (951)

MODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS

Residential Based Care Facility Guidelines

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Residential Care Facilities

Locations must be selected where the detector is not to be disturbed during the measurement period.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

WHEREAS, a photoelectric smoke alarm, in a smoldering fire, can alert a warning signal faster than a non-photoelectric smoke alarm; and

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

REQUIREMENTS & GUIDELINES

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

City of Madison Heights Landlord Licensing Program 300 W. Thirteen Mile Road Madison Heights, MI (248)

Section 8 Housing Choice Voucher Program. Housing Quality Standards (HQS) Inspection Checklist

INSTALLATION AND OPERATION MANUAL

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Conversion to Vacation Home Permit Life Safety Survey

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

Agency for Health Care Administration

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

PHOTOELECTRONIC SMOKE DETECTOR

C i t y o f G r o v e r B e a c h ADMINISTRATIVE SERVICES DEPARTMENT

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

(Inspector) Scott Ullrich Mailing Address (if Different from Business Location): Address. (FIRE) David Topping City State Zip

CITY OF DANIA BEACH Local Business Tax Receipt Division 100 W Dania Beach Blvd. Dania Beach, FL Phone: ext 3644 / Fax

a) Establishment of emergency procedures to be followed at the time of an emergency;

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

City of Boynton Beach Building Division

Residential Alcohol & Drug Rehabilitation Facilities

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

STATE OF MAINE Department of Public Safety Office of State Fire Marshal 52 State House Station Augusta, ME

Fire Safety Education in Multi- Unit Residential Buildings

Heat Alarm. Owner s Manual. Model CFH10. Rate of Rise Temperature Sensing Selectable Fixed Temperature Sensing Proprietary Wireless Connectivity

Smoke Alarm User Manual

Commercial Business Licensing Requirements

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

Smoke Alarm User s Guide

Frequently Asked Carbon Monoxide Questions

This section shall take effect on June 27, 2015 and transition period effective date of this section and June 27, 2016

A GUIDE TO THE ROCK ISLAND HOUSING CODE. Prepared By: The City of Rock Island Inspection Division

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

BUTTE COUNTY PERMIT NO: DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION* APN: Property Address. Policy Number. Carrier.

Heat Sensor. Owner s Manual

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Housing and Fire Safety Tips for Your Home & Property. Micki Jones, SFFD Rosemary Bosque, DBI May 6, 2015, SF Main Library

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Photovoltaic (Solar) Array Installation Guide

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

SECTION 915 CARBON MONOXIDE DETECTION

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

Smoke Alarm. Owner s Manual. Model CFS10. Combination Alarm

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

ORDINANCE NO

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR DÉTECTEUR DE FUMÉE PHOTOÉLECTRIQUE SUPERVISÉ SANS FILS. Model: EL-2703

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Johnson County, Kansas. Home Daycare Handbook 2013 Edition

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

Transcription:

THE TOWNSHIP OF CRANBURY FIRE SAFETY BUREAU 23-A North Main Street Cranbury, NJ 08512 PHONE 609-664-3137 FAX 609-395-8861 Dear Cranbury Resident/Real Estate Agent: There have been some changes to the Certificate of Smoke Alarm, Carbon Monoxide Alarm, and portable fire extinguisher compliance requirements. Effective January 1, 2019, all single station battery-operated smoke alarms must be ten-year sealed batteries. This is not required if alarms are interconnected. The inspector will ask for proof that the alarms are ten-year sealed batteries. Proof can be in the forms of a receipt stating it is a ten-year sealed battery, the original package the alarm came in, or the inspector may ask for the alarm to be removed so we may check and then have the alarm reinstalled. Effective January 1, 2019, as per NJAC 5:70-4.19 fire extinguishers must comply as follows. 1. The fire extinguisher shall be within ten feet of the kitchen and located in the path of egress. 2. The fire extinguisher shall be readily accessible and not obstructed from view. 3. The extinguisher shall be mounted using the manufacturer s hanging bracket so the operating instructions are clearly visible. 4. The fire extinguisher shall be an approved listed and labeled type with a minimum rating of 2A-10BC and be no more than 10 pounds. 5. The owner s manual or written operation instructions shall be provided during the inspection and left for the new occupant. 6. The extinguisher shall be serviced and tagged by a certified Division of Fire Safety contractor within the past 12 months, or the seller must have a receipt for a recently-purchased extinguisher. 7. The top of the extinguisher shall not be more than five feet above the floor.

THE TOWNSHIP OF CRANBURY FIRE SAFETY BUREAU 23-A North Main Street Cranbury, NJ 08512 PHONE 609-664-3137 FAX 609-395-8861 2019 APPLICATION FOR ONE- & TWO-FAMILY DWELLING CERTIFICATE OF SMOKE ALARM, CARBON MONOXIDE ALARM, AND PORTABLE FIRE EXTINGUISHER COMPLIANCE THERE IS NOW A $25.00 RE-INSPECTION FEE FOR EVERY TIME THE FIRE INSPECTOR NEEDS TO COME OUT TO COMPLETE THE INITIAL INSPECTION Please make sure that all detectors are in working order and batteries have been replaced within the past year Dwelling Location: Block: Lot: Street: Municipality: County: *Note: LISTED BELOW IS THE MINIMUN REQUIREMENTS FOR SMOKE AND CARBON MONOXIDE DETECTORS Sale of Home Home Rental Smoke detector on each level of the dwelling, including basements, excluding attic or crawl space; and Smoke detector and carbon monoxide alarm outside each separate sleeping area; and within 10 feet of bedrooms; and All smoke detectors are in working order. Carbon monoxide alarm(s) in working order. This is a story dwelling with without a basement. An inspection shall be conducted by the owner or an authorized representative of the owner. The smoke detectors required above shall be located in accordance with NFIPA 74; the carbon monoxide alarm(s) installed per NFPA-720. The detectors are not required to be interconnected. Battery powered detectors and alarms are acceptable. Note: AC powered and/or interconnected alarms and smoke detectors installed in homes constructed after January, 1977 shall be maintained in working order. See diagrams on back of this application for further information regarding installation. Please mail certificate to: Name Phone No. Street City State Zip Code Fax No. Contact Person: Phone No. Closing Date: I do hereby certify that the foregoing statements made by me are true. I am aware that if any of the foregoing statements made by me are willfully false, I will be subject to penalty. Sworn and subscribed to before me this day of, 20 Notary Signature Applicant Signature Printed Name Note: A check or money order payable to Township of Cranbury must accompany this application. Effective January 1, 2018 fees according to N.J.A.C. 5:70-2.3 CERTIFICATE OF SMOKE ALARM, CARBON MONOXIDE ALARM, AND PORTABLE FIRE EXTINGUISHER COMPLIANCE (CSACMAPFEC), are as follows: 1. Requests for a CSACMAPFEC received more than 10 business days prior to change of occupant $ 45.00 2. Requests for a CSACMAPFEC received 4 to 10 business days prior to change of occupant $ 90.00 3. Requests for a CSACMAPFEC received fewer than 4 business days prior to change of occupant: $161.00 4. Re-inspection fee $ 25.00 A CSACMAPFEC shall not be transferrable. If the change of occupancy specified in the application for a CSACMAPFEC does not occur within six months, a new application shall be required. ***APPLICATION AND RE-INSPECTION FEES ARE NON-REFUNDABLE***

Detectors are to be located on every level of a residence, (basement, first & second floors) excluding crawl spaces and unfinished attics and every separate sleeping area, between sleeping areas, and living areas such as the kitchen, garage, basement or utility room. In homes with only one sleeping area on one floor, a detector is to be placed in the hallway outside the bedroom as shown in Figure 1. In single floor homes with two separate sleeping areas, two detectors are required outside each sleeping area as shown in Figure 2. In multi-level homes, detectors are to be located outside sleeping areas and at every finished level of the home as shown in Figure 3. Basement level detection to be located in close proximity to be the bottom of basement stairwells as shown in Figure 3. WHERE NOT TO LOCATE DETECTORS: To avoid false alarms and/or improper operation, avoid installation of smoke detectors in the following areas: Kitchen smoke from cooking may cause a nuisance alarm Bathroom excessive steam from a shower may cause a nuisance alarm. Near forced air ducts used for heating or air conditioning. Air movement may prevent smoke from reaching detector. Near furnaces of any type air and dust movement and normal combustion products may cause a nuisance alarm. The 4 inch Dead Air space where the ceiling meets the wall, as shown in Figure 5. The peak of an A frame type of ceiling Dead Air at the top may prevent smoke from reaching the detector. FURTHER INFORMATION ON DETECTOR PLACEMENT: For further information about a smoke detector placement, consult the National Protection Association s Standard No. 74-1984, titled Household Fire Warning Equipment. For Carbon Monoxide alarms, the publication is Recommended Practice #720. These publications may be obtained by writing to the Publication Sales Department, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Carbon Monoxide alarms are to be located in every separate sleeping area per NFPA 720 and manufacturer s recommendations. There is now a $25.00 re-inspection fee for each time the inspectors need to come out after the initial inspection. Please make sure that the smoke and carbon monoxide detectors are working properly and the batteries are not older than 1 year. Batteries in the Smoke and Carbon Monoxide ALARMS should be replaced once a year. On the back of the detector it will list the approved replacement battery to use. Smoke and Carbon Monoxide manufacturers recommend the entire detector be replaced every ten years. If you are not sure how old the detector is, the date of manufacture can also be found on the back of the detector

Figure 1 Figure 3

REQUIREMENTS FOR FIRE EXTINGUISHERS AT TIME OF HOME RESALE Beginning November 1, 2005, legislation requires that fire extinguishers are to be provided at change of occupancy (resale) for one-and-two-family dwellings. Applications for Certificate of Smoke Alarm, Carbon Monoxide Alarm, and Portable Fire Extinguisher Compliance (CSACMAPFEC) will be required to provide a fire extinguisher at time of resale. New fire extinguishers are not required to be serviced and tagged by a company certified by the Division of Fire Safety. However, proof of purchase or receipt must be provided. The requirements for the type and placement of extinguishers are as follows: 1. At least one portable fire extinguisher shall be installed in all one-and-two-family detached dwellings upon change of occupancy. 2. The extinguisher shall be listed, labeled, charged and operable. 3. The size shall be no smaller than 2A:10B:C and no larger than 10 lbs. 4. The extinguisher must use hangers, or be in brackets supplied by the manufacturer. 5. Must be within 10 feet of the kitchen area. 6. Top of extinguisher should be located no higher than 5 feet above the floor. 7. The extinguisher should be visible and in a readily-accessible spot. 8. Should be near a room exit or travel way that provides an escape route to the exterior. 9. The extinguisher should be accompanied by an owner s manual or written information regarding the operation, inspection, and maintenance of the extinguisher. 10. Installed so the operation instructions are clearly visible. Questions regarding fire extinguisher placement and use may be directed to the Fire Safety Bureau at Cranbury Township.