Call stations and extensions

Similar documents
Cerberus PACE Operating terminals / Call stations Operation Manual

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Mimic display driver, LED ribbon cable

Fire control panels FC360

Output module (230 V)

Fire control panels FC726 FC726-XA

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

Multi line separator module

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Dear Customer! FIRE FIGHTERS CALL STATION - INTRODUCTION

Input module, input/output module

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Vocia VACIE. Reference Guide

Fire control panel for modernization

FC723 Fire control panel

AUDIO- AND ALARMMANAGEMENT

Electronic timeswitch

FC724 Fire control panel

VACIE REFERENCE GUIDE REVISION 1.2.6

FC722 Fire control panel

OH720, OP720, HI720, HI722

Entero Voice Alarm system.

FC722 Fire control panel

FC724 Fire control panel

N-8000 SERIES IP INTERCOM SYSTEM

Input module, input/output modules

PA/VA solutions for transport industry

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

16 Zone Voice Evacuation VA & PA Sound System

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

DSE ELECTRONIC SIRENS Advantages & Functions

Get all messages across, no matter what.

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FT2080 Fire terminal (Touch) Mounting Installation

Notification. Public Address & Voice Alarm Systems

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Frost Protection Thermostat

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

FDOOT221, FDO221, FDT221

Voice Alarm system integration

VOICE ALARMING SYSTEM»ONE-BOX-DESIGN« EN / EN 54-4 / VDE / EN / VDE 0828 THE SIMPLE»ALL-IN-ONE«SOLUTION.

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Elemec3. Networked Public Address and General Alarm System (PA/GA)

AE300. Integrated Voice Alarm System

FT2080 Fire terminal (Touch) Mounting Installation

Room thermostat with 24-hour time switch and large LCD

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

IC60 Sintony 60 Intrusion Control Panel

FDCW241 Radio gateway Mounting

New Products sounds more than safe..

PUBLIC ADDRESS SYSTEM

ASA linear smoke detector

FC2020 Fire control panel

FDM273 Radio manual call point Mounting

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Public Address Project Combisound System

Radio fire detection system

Solutions for Mass Notification Systems

Bosch Plena Public Address and Voice Alarm System The fast route to safety

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

Denon USA A/V Receivers

School Paging. IP/SIP Intercom and Paging. Prepared by: John Vellone

OOH740, OOHC740 Automatic fire detectors

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

XC10 Extinguishing control panels

TABLE OF CONTENTS. HEADQUARTERS Severo Ochoa, Málaga, Spain Tel / Fax

The Ultimate, Digital Public Address & Voice Alarm System FLEXIBILITY UNLIMITED

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

X-618 Digital Public Address and Voice Alarm System. Cherian George Product Manager PAVA systems

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

RVL479. Heating Controller. for use with a partner unit

Panel Mounted Fault Annunciator Series

1592P01. for liquids in piping DN

USER MANUAL FOR OPERATING SYSTEM

Operation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc.

Networked Public Address and Voice Evacuation

SI120 Guarto Easy I. Alarm system. Fire & Security Products

SP40S-D. Kingfisher Company, inc. Features: Description:

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

GAI-Tronics Systems NEW! Elemec3 Digitally Controlled PA and General Alarm system PA/GA

FDOOT241-A9-Ex Multisensor fire detector

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Fire control panel detect 3004 plus and accessories

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

Fume Hood Operating Display Panel

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

Frost Units for air temperature monitoring

tyco PAVA IP Audio Voice Alarm Router tyco PAVA Systems Features : K ƉƟŽŶĂůD ŽĚƵůĞƐ

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

600 Range Dialer Installation Manual. Version 1.0

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

SOUND SYSTEMS NEW PRODUCTS

IP-based Building Management Control

Transcription:

Novigo Call stations and extensions PT2001-A1, PT2002-A1, PT2008-A1, PT2009-A1, PTO2001-A1, PTO2002-A1, PTO2003-A1, PTO2004-A1, PTO2005-A1, PTO2006-A1, PTO2008-A1 EN 54-16-certified alarm and business microphones for demanding digital and network-based public address and evacuation applications Fully redundant configurable system with no 'Single Point of Failure' Ethernet interface ('PACE-Net') for networking with other system components Serial interface ('PACE-Bus') for connecting to internal and external components Real-time configuration, remote maintenance, and remote monitoring via the 'PACE-Design' system software Real-time audio transmission and integrated real-time recorder for delayed announcements Analog NF audio inputs and outputs, plus analog and digital control inputs and outputs Freely configurable buttons with insertable labels Can be extended with button and key switch modules Up to 115 buttons can be configured per call station Availability of fire brigade call station that conforms to ÖNORM F 3003 Integrated speaker and monitored microphone Integrated Micro-SD card reader for alarm messages and music 2018-10-22 Control Products and Systems

Features and Functions Desk call stat. (19 buttons) PT2001-A1 Call station with electret condenser microphone and gooseneck Full network participant in a Novigo system 2-line text display 19 freely configurable buttons with status indicator Insertable labels for custom button identification Monitored microphone Integrated speaker 1x additional NF audio input (line/mic) and 1x additional NF audio output 4x digital inputs, 6x digital outputs Live speech / real-time audio transmission and integrated real-time recorder for delayed announcements Integrated Micro-SD card reader/writer with max. 2 GB card capacity for alarm messages and music Recording capacity: 256 files with a total duration of approx. 3 hours Provision of alarm announcements, alarm tones, and music 2x Ethernet LAN interfaces for connection to 'PACE-Net' Can be extended using button modules with status indicator and key switches Desk call station extension (24 buttons) PTO2001-A1 Optional button extension for the desk call station PT2001-A1 24 freely configurable buttons Up to 4x button extensions per desk call station PT2001-A1, offering a total of 115 buttons Insertable labels for custom button identification Desk call station extension (Kaba) PTO2002-A1 Call station extension for PT2001-A1 with key switch (Kaba) For enabling call station operation Figure similar Desk call station extension (Nordic) PTO2003-A1 Call station extension for PT2001-A1 with key switch (Nordic) For enabling call station operation 2

ITEC SPM-DM microphone DCS PTO2004-A1 Dynamic gooseneck microphone Supercardioid characteristics Excellent suppression of background noise Highly dynamic performance and wide frequency band with low distortion XLR connection Mounting kit DCS (19"/5HU) PTO2005-A1 19" mounting kit for call stations For mounting call stations in a 19" cabinet 5HU Fire brigade call stat. (AT) PT2002-A1 Alarm call station with standard-compliant housing and control panel Full network participant in a Novigo system 7 standardized and pre-configured buttons 3 standardized and pre-configured displays Removable hand-held microphone with speak button Microphone and line monitoring Real-time audio transmission with constant latency: 4.6 ms analogin/analog-out Integrated real-time recorder for delayed announcements Integrated industrial Micro-SD card reader/writer with max. 2 GB card capacity for alarm messages and music Recording capacity: 256 files with a total duration of approx. 3 hours Provision of alarm announcements, alarm tones, and music 2x Ethernet LAN interfaces for connection to 'PACE-Net' 3

Desk call station (analog, 3+1) PT2008-A1* Call station with 3 configurable zone buttons plus speak button Electret condenser microphone with gooseneck Symmetrical audio transmission Audio output 0 db (line volume) Control signals for zones 1-3 and 'Speak' Connection to control panel via CAT5 cable or above (max. 150 m) and RJ45 connector Supplied adapter module for connection to control panel Insertable labels for custom button identification Robust sheet steel housing * The desk call station PT2008-A1 does not have approval in accordance with EN 54-16. Desk call station (RS485, 8+1) PT2009-A1 Call station with 8 configurable, illuminated zone buttons plus speak button Electret condenser microphone with gooseneck Symmetrical audio transmission, analog RS485 data transmission ('PACE-Bus') Audio output 0 db (line volume) Connection to control panel via CAT5 cable or above (max. 500 m) and RJ45 connector Up to eight call stations can be configured in a cascade 'daisy chain' Adapter module PTO2008-A1 for connection to the control panel Option to add up to three extension modules, each with 8 zone buttons Integrated audio amplifier (1 watt) and speaker Addressable via 8-way SIP switch in device Insertable labels for custom button identification Robust sheet steel housing Desk call station extension (RS485, 8) PTO2006-A1 Optional button extension for desk call station PT2009-A1 Up to 3 button extensions possible for desk call station PT2009-A1, offering a total of 32 buttons 8 configurable, illuminated zone buttons Insertable labels for custom button identification 4

Desk call stat. int. (8+1) PTO2008-A1 Adapter for connecting the desk call station PT2009-A1 to a control panel Use System Novigo is a network-based voice alarm and announcement system that complies with the requirements of EN 54-16 and allows for a decentralized and redundant system structure. The avoidance of a 'Single Point of Failure' is an important feature of the system design. A typical Novigo system is comprised of a digital audio matrix, amplifiers, operating terminals, and call stations. Ethernet switches are used to link these components to a network via copper or fiber-optic cables. Novigo systems are configured in real-time using the 'PACE-Design' system software. An EN 54-4-certified power supply guarantees uninterrupted operation and high system availability. Novigo is designed for the following applications: Alarms and evacuation Automatic activation of acoustic alarm and evacuation signals through a connected hazard detection system, such as a fire detection system Manual activation of acoustic alarm and evacuation signals by trained staff Live announcements made by trained staff Playback of announcements recorded in advance Announcements Background music Live announcements, with optional delay feature Playback of announcements recorded in advance Novigo covers both applications within one integrated system. It complies with the stringent requirements that apply to voice alarm systems in line with EN 54-16 and the extremely high standards for the audio quality and convenience of a standard announcement system. 5

PT2001-A1 call station Novigo offers a range of call stations for various applications. The alarm and business call station PT2001-A1 is designed for the following applications: Selecting speaker circuits Selecting an audio source Transmitting live announcements Controlling and monitoring the Novigo system For other applications, see Call stations Up to four additional button modules can be fitted to extend the desk call station PT2001-A1 to a maximum of 115 buttons. An optional key switch module enables all or individual call station buttons to be released or locked individually. PT2008-A1 and PT2009-A1 call stations The desk call station PT2008-A1 is designed for small business applications. The desk call station PT2008-A1 does not have approval in accordance with EN 54-16. The desk call station PT2009-A1 is designed for small to medium-sized business applications. The desk call station PT2009-A1 is pending approval in accordance with EN 54-16. Up to three additional button modules can be fitted to extend the desk call station PT2009-A1 to a maximum of 32 buttons. PTO2008-A1 adapter The adapter PTO2008-A1 connects the desk call station PT2009-A1 to a control panel when required. PTO2005-A1 mounting kit The mounting kit PTO2005-A1 allows a desk call station to be installed in a 19" cabinet. PT2002-A1 fire brigade call stat. (AT) The network-based fire brigade call station PT2002-A1 is designed for use by the fire brigade or trained security personnel. The alarm and system status can be monitored. The integrated hand-held microphone can be used to make live announcements. The pre-configured alarm announcement buttons can be used to play stored alarm and evacuation announcements. Live announcements or stored alarm and evacuation announcements can be played throughout the entire building or in single areas. The system interrupts all other audio outputs throughout the building or in the selected areas as soon as an alarm announcement button or the speak button of the hand-held microphone is pressed. 6

Type Overview Call stations Type PT2001-A1 PT2008-A1* PT2009-A1 PT2002-A1 Designation Desk call stat. (19 buttons) Desk call stat. (analog, 3+1) Desk call stat. (RS485, 8+1) Fire brigade call stat. (AT) Order number S54451-B6-A1 S54451-B32-A1 S54451-B33-A1 S54451-B9-A1 W x H x D mm 220 x 55 x 220 (without microphone) 105 x 65 x 185 (without microphone) 200 x 300 x 157 Weight 2.2 kg 1.1 kg 4.5 kg Network 'PACE-Net' (Ethernet) (2x) (2x) 'PACE-Bus' (RS485) Max. cable lengths (copper) Buttons and displays Number of configurable buttons Buttons configurable for: 100 m 500 m 500 m 100 m 19 3 8 - Announcements (pre-assigned) - Control signals (pre-assigned) Text display Memory Micro-SD card reader Real-time recorder 7

Type PT2001-A1 PT2008-A1* PT2009-A1 PT2002-A1 Inputs and outputs Integrated speaker Additional audio outputs Additional audio inputs Digital control inputs and outputs Analog control inputs 1 1 2 2 Included Not included * Not approved in accordance with EN 54-16 Microphone extensions Type PTO2001-A1 PTO2002-A1 PTO2003-A1 PTO2006-A1 Designation Desk call stat. ext.(24 btn) Fig. similar Desk call stat. ext. (Kaba) Desk call stat. ext.(nordic) Call station ext. (RS485, 8) Order number S54451-B7-A1 S54451-B8-A1 S54451-B48-A1 S54451-B51-A1 W x H x D mm 220 x 55 x 220 95 x 55 x 220 105 x 65 x 185 Weight 1.9 kg 0.98 kg 1.0 kg Properties Number of buttons 24 8 Key switch Compatible with: PT2001-A1 PT2009-A1 Compatible Not compatible Accessories You will find more information on suitable accessories in the data sheet with document ID 'A6V10430563'. 8

Order numbers Type Designation Order number Call stations PT2001-A1 Desk call stat. (19 buttons) S54451-B6-A1 PT2008-A1 Desk call stat. (analog, 3+1) S54451-B32-A1 PT2009-A1 Desk call stat. (RS485, 8+1) S54451-B33-A1 PT2002-A1 Fire brigade call stat. (AT) S54451-B9-A1 Microphone extensions PTO2001-A1 Desk call stat. ext.(24 btn) S54451-B7-A1 PTO2002-A1 Desk call stat. ext. (Kaba) S54451-B8-A1 PTO2003-A1 Desk call stat. ext.(nordic) S54451-B48-A1 PTO2006-A1 Call station ext. (RS485, 8) S54451-B51-A1 PTO2008-A1 Desk call stat. int. (8+1) S54451-B58-A1 Microphone PTO2004-A1 ITEC SPM-DM microphone DCS S54451-B49-A1 Mounting kit PTO2005-A1 Mounting kit DCS (19"/5HU) S54451-B50-A1 9

Product documentation You will find more information on the Novigo system and its components in the following documents: Title IT security policies Novigo IT security policies* System documentation Novigo planning* 'PACE-Design' configuration* Novigo mounting / installation Novigo operation Data sheets System data sheet Document ID A6V11439692 A6V11467812 A6V11474760 A6V11467817 A6V11467803 A6V11467196 19" cabinets A6V11467209 Digital audio matrix Power amplifier Operating terminals Call stations Power supply and batteries Accessories and options Environmental declaration Novigo environmental declaration A6V11467202 A6V11467204 A6V11467198 A6V11467200 A6V11467207 A6V11467211 A6V11546319 *You can obtain these documents from the product support platform via the following link: https://psp.sbt.siemens.com/. Download center https://siemens.com/bt/download Enter the document ID in the search field. 10

Notes Safety CAUTION National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage. Observe national provisions and comply with the appropriate safety regulations. Configuration 'PACE-Design' is the Windows-based software used to configure and monitor a Novigo system. With the 'PACE-Net' API, other control systems can be connected, including danger management systems and media control systems. Comprehensive monitoring and logging features make it easier to operate large-scale systems. DSP and controller software can be updated from any point within the network. Example PT2001-A1 System Tree Keypad Config Table Different functions can be assigned to each switch, for example: Zone selection Speak switch All zones Gong Deleting Alarm messages Volume +/-, up/down, etc. Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 11

Technical data Call stations Supply PT2001-A1 Power supply DC 24 V (18 V...32 V) Current consumption Number of inputs / outputs Audio inputs 0 db (external source) Audio outputs 0 db (to amplifier / external) 260 ma Analog control inputs 0...10 V 6 (plug-in terminal blocks) 2 1 PT2002-A1 Digital inputs 4 (Schmitt trigger inputs on plug-in terminal blocks) Digital outputs 6 (Open collector outputs on plug-in terminal blocks) Digital inputs Input voltage Max. permissible voltage Input current at 10 V Digital outputs Max. voltage Max. current Analog control inputs Voltage range Resolution Input current at 10 V Interfaces Serial interfaces Ethernet connection 100Base-TX Max. cable lengths (copper) Low <1.6 V / High >8 V 18 V ~0.2 ma 36 V 200 ma per output / total 500 ma (total of all switched outputs) DC 0...10 V 8 bit ~0.2 ma RS232 (9600, 19200, 57600, 115200 baud) 2x RJ45 100 m 12

Audio properties Frequency band PT2001-A1 40 Hz...20 khz / -1 db Distortion factor <0.0005 % Total dynamic range Inputs: Phantom voltage Input impedance Outputs: Max. output level Output impedance Ambient conditions 103 db PT2002-A1 Symmetrical; max. amplification freely selectable between -20 db...+60 db +12 V; switchable 6.6 kohm Out1: Speaker, 1 W Out2: Symmetrical +15 db 300 Ohm Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments (without moisture condensation) Storage in humid environments (without moisture condensation) Dimensions and weights W x H x D mm 220 x 55 x 220 (Housing without microphone) 10...90 % rel. 5...90 % rel. 200 x 300 x 157 Weight 2.2 kg 4.5 kg Protection category and color Protection category (IEC 60529) Color Light gray Red Standards EN 54-16 ÖNORM F 3033, EN 54-16 Approval ÖNORM F 3012 IP30 13

Supply PT2008-A1 PT2009-A1 Power supply DC 10...12 V (via RJ45) DC 24 V (via RJ45) Current consumption Max. 100 ma Max. 50 ma Number of inputs / outputs Audio outputs 0 db (to amplifier / external) Interfaces Serial interfaces RS485 Max. cable lengths (copper) Ambient conditions 1 500 m Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments (without moisture condensation) Storage in humid environments (without moisture condensation) Dimensions and weights W x H x D mm 10...90 % rel. 5...90 % rel. Housing without microphone 105 x 65 x 185 Housing with microphone 105 x 330 x 185 Adapter for connection to control panel Weight Protection category and color Protection category IEC 60529 Color 45 x 42 x 68 mm 70 x 36 x 70 mm 1.1 kg IP20 Light gray Standards EN 54-16 14

Microphone extensions PTO2001-A1 PTO2002-A1 PTO2003-A1 PTO2006-A1 Power supply DC 24 V (18 V...32 V) Number of buttons and key switches Buttons 24 8 Key switch (Kaba) 1 Key switch (nordic) 1 Ambient conditions Operating temperature -5 +40 C Storage temperature -20 +70 C Operation in humid environments (without moisture condensation) Storage in humid environments (without moisture condensation) Dimensions and weights W x H x D mm Housing 10...90 % rel. 5...90 % rel. 220 x 55 x 220 95 x 55 x 220 105 x 65 x 185 Weight 1.9 kg 0.98 kg 1.0 kg Protection category and color Protection category (IEC 60529) Color IP30 Light gray Standards EN 54-16 IP20 15

Mounting kit PTO2005-A1 Type Mounting kit DCS (19"/5HU) Height units 5HU Material Metal Dimensions and weights W x H x D mm 483.6 x 52.3 x 216.9 Weight 400 g Color Light gray Standards EN 54-16 Microphone Type Connection Audio properties Directional characteristics Frequency band -6 db Sensitivity Nominal impedance Ambient conditions PTO2004-A1 Dynamic microphone XLR / M Supercardioid 100...10000 Hz -56 db V/PA (1.58 m V/PA) ±3dB; 1Pa = 94 db SPL 500 Ohm Operating temperature -10 +50 C Storage temperature -20 +70 C Operation in humid environments (without moisture condensation) Storage in humid environments (without moisture condensation) Material Dimensions and weights 10...90 % rel. 5...90 % rel. Metal W x H x D mm 41 x 360 x 41 Weight Protection category and color Protection category (IEC 60529) Color 170 g IP30 Black Standards EN 54-16 16

Environmental compatibility The product environmental declaration for 'Novigo VANSYS 3.0' contains data and information on the product's environmentally compatible design features and its ratings; for example, its RoHS conformity, composition, packaging, environmental benefits, and disposal information. You can obtain the document A6V11546319 via the following Internet address: https://siemens.com/bt/download Enter the document ID in the search field. 17

Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2018 Technical specifications and availability subject to change without notice. 18 Document ID Edition 2018-10-22