GENANO AIR PURIFICATION TECHNOLOGY

Similar documents
Air Purification System. Instruction Book CLI-AP20

Cool Mist Ultrasonic Humidifier

AirInstinct Air Purifier

TOTALCLEAN AIRPURIFIER. instruction manual. YEARGuarantee AP-25A-GB

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle

GENANOTUBE XS (MEDICAL)

WHYNTER Eco Pure Air Purifier

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

HEPA Air Purifier with Ion Flow Technology

Note: Verify that plastic bags are removed from filters, if equipped or installed, before first use (see page 8) CONTENTS

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

Owners Manual Model: XXL

THANK YOU FOR PURCHASING THE LV-PUR131 TRUE HEPA AIR PURIFIER BY LEVOIT. GET STYLE #LevoitLove #LevoitLifestyle

SAFETY INSTRUCTIONS. General Safety Instructions. Safety Instructions Operating Instructions Troubleshooting Tips Customer Service

COOL MIST HUMIDIFIER USER MANUAL FOR MODEL: PAU1. Your Source for Home Comfort

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

3-In-1 Heated Wrap WarmtH WHere you Need It lk rints:1/1,b _P rap eated W utput:100% _O _3-in-1 H S x4.75 H 97_IN 43 ize:5 W 73 S

Register your product and get support at. AC4076. User manual

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

Welcome to a Healthy Home

IMPORTANT SAFETY INSTRUCTIONS

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

(The chances are you re never going to read me) Owner s Manual. Model S10E.

Air always contains a certain amount of water in the form of vapour. This determines the

Model CWA200 Owner s Manual

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

Comefresh CF-8608 Air Purifier

Instruction Manual Item No.: V~, 60Hz

Important Safeguards. Save these instructions for future reference. (continued on next page)

owner s manual Air filtration system 99 % For models : EP1625 / EP2020 / EP2532

Professional HEPA Air Cleaner

SAVE THESE INSTRUCTIONS

BioZone Scientific International contact information

Clean Air Optima HEPA UV ionizer air purifier CA-508

Steam Bug. World's smallest steam iron great for travel

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

Personal Ultrasonic Humidifier. FALLH-01 series

ELECTRIC FIREPLACE OWNER S MANUAL

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

Warranty. Hello! Owner s manual. Return this card now for: Models: Registration Card. Ultra Quiet Air Purifier

KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea

USER MANUAL SAVE THESE INSTRUCTIONS

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

Register your product and get support at AC4002 AC4004. User manual

Model Instruction Manual. Coleman Limited One-Year Warranty. 26 Quart Power Cooler. For use with 12 VDC only

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

RECHARGEABLE CYCLONIC VACUUM CLEANER WITH POWER BRUSH

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

INSTRUCTIONS AND WARRANTY

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

5) Do not start or stop the unit by inserting or pulling out the power plug.

Instruction Leaflet. 99% HEPA air cleaners MODEL BAP

User Manual. TN1500 Embedding Center. Read Prior to Operation! Always keep this manual near the unit! WP

YOUR PORTABLE AIR PURIFIER

Portable Air Conditioner

Ultra Lightweight Household & Commercial Vacuums

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

I N S T R U C T I O N S

Instruction Manual Item No.: V~, 60Hz

O w n e r s M a n u a l

Shiatsu Neck and Shoulder Massager KNEADING MASSAGE FOR HARD-TO-REACH MUSCLES

User Manual Watt Drop-In Induction Range. Model: ID18DB 08/2017. Please read and keep these instructions. Indoor use only.

USE & CARE INSTRUCTIONS

Ultrasonic Humidifier

Operating Instructions

Infra-Heat Lumbar Cushion & Extender

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL

Electric Digital Kettle

DZ5080 US Index01 19/09/07 10:50 Page 2

DEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR

O w n e r s M a n u a l

MODEL 7000 SUCTION UNIT

31468_S-8300_IB 6/15/06 4:09 PM Page 1. Tourmaline Ceramic Curved Plate Styler. Use and Care Guide S-8300

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

MINI ELECTRIC CONVECTION HEATER

Electrostatic Air Purifier

ULTRASONIC HUMIDIFIER

Please read this manual carefully before use to ensure proper usage and save

T100 Air Purifier USER MANUAL

Introduction. Features. Benefits. Records

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

OPERATION & INSTALLATION MANUAL AIR PURIFICATION SYSTEM (APS300)

IMPORTANT SAFETY INSTRUCTIONS

OPERATING INSTRUCTIONS

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

Replacement Filter Information

Thermal Electric Wine & Beverage Chiller. Model: WC-20TL (20 Standard Bottle Capacity) Instruction Manual

AIR PURIFIER WITH GERMICIDAL UV LIGHT

Tower Ceramic Heater

Air Purifier. Purificador de aire. Use and Care Guide Manual de uso y cuidado. Model / Modelo : HAP52010E

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

DIGITAL Warm & Cool Mist Humidifier

OWNERS INSTRUCTION MANUAL

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

ADORABLE Air Purifiers

Transcription:

GENANO AIR PURIFICATION TECHNOLOGY GENANO 310 AIR PURIFICATION DEVICE OPERATING INSTRUCTION This manual is for the Genano 310 log. Version. GENANO LTD Kimmeltie 3 FI- 02110 Espoo FINLAND Tel + 358 (0) 9 7743 870 Fax + 358 (0) 9 7533 130 info@genano.fi

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 GENANO 310 PURIFICATION DEVICE FOR INDOOR CLIMATE 3 IMPORTANT SAFETY INSTRUCTIONS 3 CONTENTS 4 TECHNICAL FEATURES 4 INSTALLATION AND OPERATING INSTRUCTIONS 5 PARTS AND INDICATIONS OF SYMBOLS 5 BEFORE USE 5 INSTALLATION 6 WASHING LIQUID 6 POSITIONING 6 WALL MOUNTING 7 OPERATION OF THE DEVICE 7 NORMAL OPERATION 7 RUNNING OUT OF WASHING LIQUID 8 ERROR/SERVICE 9 RESETTING PROGRAM SETTINGS 9 POWER WASH 9 GAS ABSORPTION PLATE 10 WARRANTY 12 IMPORTANT SAFETY INSTRUCTIONS 13 TROUBLESHOOTING GUIDE 14 READ OWNERS MANUAL CAREFULLY!

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 3 GENANO 310 PURIFICATION DEVICE FOR INDOOR CLIMATE The GENANO 310 is an air purification device based on Genano s unique MFI system. Genano s patented MFI removes even the smallest impurities from indoor air. These impurities can consist of viruses, bacteria, mould spores, animal dander as well as traffic originated soot. These ultra fine-particles (UFP) have recently been recognized to constitute a health hazard. UFP s easily penetrate into bronchial regions and can pass directly into the blood circulatory system. In many cases, fine-particles are the origin for cardiac and vascular discomfort, cancer and even premature death. The MFI system is equipped with a gas absorber for the removal of harmful gases and ozone. The continued use and maintenance of the 310 air purifier will ensure you a comfortable breathing environment. The GENANO 310 is self-cleaning and requires only regular filling of Genano washing fluid + water and to regularly empty the dirty flush water basin. Clean the basin soon after the washing if you want to ensure that there will not grow any unwanted growing material. The GENANO 310 air purifier has been tested by independent certification organizations. These experts have officially certified that the cleaning results exceed 98% for atmospheric particles and microbs in the 0.003-10µm range. IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this appliance. When using an electric air cleaning device, basic precautions should always be followed, including the following: DANGER To reduce the risk of electric shock: 1. Do not reach for a plug of an air purifier device that has fallen into water. Disconnect power at source then unplug immediately. 2. Do not use in close vicinity while bathing or in a shower. 3. Do not place in heavily moist atmosphere, water or other liquid. 4. Do not place or store an air purifier device where it can fall or be pulled over. 5. Unplug this air purifier device before moving or transporting it to another location. 6. When discarding material used in this air purifier device, follow instructions issued by local authorities for disposal. See enclosed sheet for instructions. 7. Ensure that wall socket is grounded. 8. Lock the bottom basin when G310 is operated near children or pets. IMPORTANT! To reduce the risk of electric shock, this equipment has a grounding type plug that has a third (grounding) terminal. This plug is only allowed to connect into a grounding type power outlet. If there is no grounded outlet installed, contact qualified personnel to install the proper outlet. Do not alter the plug in any way. WARNING! Due to its mode of operation the electronic air purifier may occasionally emit sparks. Never use the air purifier in a place where flammable gases or liquids or large amounts of dust may combine with air to form an explosive mixture.

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 4 CONTENTS 1 Bottle: Genano washing fluid (1 ltr) OR 1 Bottle: Genonex anti-bacterial washing fluid (5ltr) 1 Mixing/water can *To make refilling the 310 as easy as possible. Notice the marks on the side for easy measuring *only use approved Genano washing fluid in any of Genano s machines 1 plastic basin container *empty basin on a regular basis and clean away any remaining residue every month with a towel or soft brush DO NOT SCRATCH BASIN 1 GENANO 310 air purification unit with mains power cable *contains 1 gas absorber to handle gas emissions. Make sure filter is changed annually TECHNICAL FEATURES Use: Dimensions: Weight, approx: Chassis: Indoor air environment only 450mm x 385mm x 1470mm 55kg Capacity: 100-250m 3 /h Operating voltage: Power consumption: Cleaning range: Ambient temperature: Aluminum, zinc coated steel 200-240V, 50/60Hz 140W max >0.001µm +5 - +60 C Humidity level of air: 0-95% Positioning: stand vertically on an even base or wall mount. Unit has bottom wheels for portability. Always maintain vertical position. NEVER USE OR STORE HORIZONTALLY *If machine is stored horizontally then flush out all washing liquid with regular water Washing: Automatically runs washing cycle once a week. Always fill with GENANO washing fluid and water when the yellow FILL WATER light comes on. Empty the flush water basin regularly. 385 mm 1470 mm 450mm Clean air distributed Polluted air sucked into the air cleaner

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 5 INSTALLATION AND OPERATING INSTRUCTIONS PARTS AND INDICATIONS OF SYMBOLS A. BOTTOM BASIN (basin for flush water / clean water container) B. SIGNAL LIGHTS - OPERATION Green light OK - AUTOMATIC WASH/DRYING Green light - CLOSE BASIN Green light - ERROR/SERVICE Red light - FILL WATER Yellow light C) B) C. OPERATION SWITCHES - MAIN SWITCH (ON/OFF) A) - POWER WASH BEFORE USE - FAN SETTINGS/CAPASITY 100m 3 /h to 250 m 3 /h *Maximum air volume output may vary depending on air purification needs and version type This product should always be transported in a vertical position. If transported horizontally let device dry 8 hours in vertical position before switching on. Standing vertically on a stable, even base or wall mount. ATTENTION: NEVER USE HORIZONTALLY.

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 6 INSTALLATION 1. It is recommended to fill the water container before switching the device ON. 2. Open the bottom basin by unlocking (d) and using the attached handle (e). 3. Fill the water container (g) with water and washing fluid mixture (See instructions below) (max. about 1,5 liters) D E DO NOT CONNECT VOLTAGES OTHER THAN THE FACTORY LABELED RE- QUIREMENT. 4. Make sure that the main switch is in the OFF position (see above). Plug the main power cable into GENANO 310 before you plug in the main cable into a grounded power socket. 5. Push the main switch into ON - position. G LOCK THE BOTTOM BASIN WHEN OPERATED NEAR CHILDREN OR PETS WASHING LIQUID Genonex is premixed so just pour into watering container and pour in container (g) Take 1,5 liters of distilled water and 1 dcl of Genano MFI-washing fluid and mix in the watering can provided POSITIONING When position your unit please try to observe the following: Position the unit where the people are working or staying for maximum effect (preferably in the center of the area). Do not treat unit as furniture and place in a corner for aesthetics or behind solid abject for cover. The closer the unit is to the people the better results they will feel!! Take care of normal ventilation. Do not position G310 in rooms where is no ventilation. Be sure to position away from air intake vents so clean air isn t drawn immediately into the air ducts.

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 7 WARNING! Due to its mode of operation the electronic air purifier may occasionally emit sparks. Never use the air purifier in a place where flammable gases or liquids or large amounts of dust may combine with air to form an explosive mixture. WALL MOUNTING It is possible to mount the GENANO 310 unit on the wall using brackets provided by Genano. Simply fasten the mounts to a wall capable of supporting 70kg by placing both brackets on the wall vertical to each other and 800mm apart from the metal mount (picture 1). Then simply slide the unit onto the wall mounts taking care that the metal tab slides into the holders on the back of the 310 unit (picture 2) Picture 1. Placing the mounting GENANO 310 Back panel Picture 2. Wall 800mm Place unit by sliding wall mount into metal holder on back of unit Holder Fastener Wall mount OPERATION OF THE DEVICE NORMAL OPERATION Genano 310 is cleaning air when OK-light is illuminated. The device efficiently collects atmospheric particles on the collection surfaces. Washing of the collection surfaces takes place automatically once a week. Important! It is recommended to let the unit be continuously ON to ensure the weekly washing. During the flushing of the collection surface the green WASH light is on. After the flushing cycle has ended the GENANO310 starts its drying period. During the drying cycle the 310 is silent and the green WASH light on. Do not open the door immediately after the wash cycle. Allow time for the washing liquid to drain into the basin.

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 8 The washing cycle lasts about 5-10 seconds, the drying period can vary (1min 8 hours) *If the unit is very wet inside it could take longer to dry). *If the machine does not restart after a few hours then call your service representative. NOTE: It is normal that the WASH light is on after the device has completed flushing and the device is totally quiet. The GENANO 310 continues its normal air cleaning operation automatically when the drying period is over. NOTE: Clean the basin after the washing operations if you want to ensure that there will not remain any harmful material. RUNNING OUT OF WASHING LIQUID The device is unable to perform the automatic washing function, if the container has run out of water* The yellow FILL WATER light is on (See signal lights) The 310 will continue its normal air cleaning operation even if one automatic wash cycle is missed due to a lack of washing mixture. However, the device stops the air-cleaning operation if washing liquid/water is still not added after week to the wash water container. Fill up the water container according to instructions given in the info sheet. Do not switch the unit OFF. The yellow FILL WATER light will be lit until the water container is filled. The device turns ON only after the filling up of the water container with the washing mixture. 1. Add washing mixture to the water container according to the installation instructions 2. Empty and clean the flush water basin if necessary 3. Shut the bottom basin. The device automatically starts the normal air cleaning operation after the bottom basin is closed. The FILL WATER light turns off and green OK light illuminates again. If the bottom basin is not closed during the operation, the green CLOSE BASIN light illuminates and the air cleaning operation is turned off automatically. The device automatically continues normal operation when the bottom basin is closed and the CLOSE BASIN light turns off.

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 9 ERROR/SERVICE Record all steps taken when the service light comes on. Include recent events, moves and what lights were on before the service light came on. This will help your Genano service representative identify and solve the problem quicker. If the normal operation is disturbed, the red ERROR/SERVICE light is continuously lit. If the ERROR/SERVICE light is on then: 1. Check that there is water in the water container 2. Check that the basin door in closed 3. Perform power wash If the ERROR/SERVICE light has still not gone out then reset unit (see instructions below). If ERROR/SERVICE light is still on check the troubleshooting guide for a possible solution. If no solution can be found then contact an authorised Genano service representative. RESETTING PROGRAM SETTINGS 1. Switch the unit OFF and wait about 20 seconds. 2. Switch ON. POWER WASH The power wash function can be performed by using the power wash switch (check c operation switches on page 5). This operation is useful if the air cleaning operation is interrupted due to increased dirtiness of the collection surface. The flashing ERROR/SERVICE light illustrates the device is extremely dirty. It is recommended that the power wash be performed every 6 months even if no operational problems have occurred. Perform the Power Wash as follows: 1. Empty the flush water basin and fill the wash water container before performing the power wash. 2. Press the power wash switch and hold it down until the 310 machine starts the wash cycle (about 5 seconds) The Power wash lasts about 5 seconds. Following the power wash the AUTOMATIC WASH/DRYING light is on while the machine dries. The drying cycle can last a few minutes or longer depending on how damp the machine is. Do not open the door immediately after the wash cycle. Allow time for the washing liquid to drain into the basin. 3. Once the drying cycle is complete the unit will resume normal operation

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 10 NOTE: Clean the basin after the washing operations if you want to ensure that there will not remain any harmful material. GAS ABSORPTION PLATE Besides particles, the Genano air cleaner can also remove gases. Using a gas absorption plate, different kinds gases can be removed from the indoor air e.g. traffic originated sulphurand nitrogen oxides as well as ozone. The typical exchange period of the gas absorption plate is 12 months. Gas absorber replacement can only be performed by service personnel authorised by Genano Ltd. ATTENTION: DO NOT OPERATE THE GENANO 310 UNIT WITHOUT THE GAS ABSORPTION PLATE Gas Absorber Exchange dates Date of purchase Gas Absorber Exchange dates

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 11

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 12 WARRANTY GENANO 310 MULTIFUNCTION-ION, MFI, and NANOBIO are Registered Trademarks for Genano Limited Corporation products. All Rights Reserved. FULL 12 MONTHS WARRANTY Genano Ltd warrants each new MFI Air Cleaning Product, Model against defects in materials or workmanship for a period of one year from the date of purchase, and agrees to repair or replace any defective product without charge. IMPORTANT: This warranty does not cover damage resulting from accident, misuse or abuse, lack of reasonable care, the affixing of any attachment not provided with the product or loss of parts or subjecting the product to any but the specified voltage. Use of unauthorized replacement parts will void this warranty. GENANO CORPORATION WILL NOT PAY FOR WARRANTY SERVICE PERFORMED BY A NON-AUTHORIZED REPAIR SERVICE AND WILL NOT REIMBURSE THE CONSUMER FOR DAMAGE RESULTING FROM WARRANTY SERVICE PERFORMED BY A NON-AUTHORIZED REPAIR SERVICE. NO RESPONSIBILITY IS ASSUMED FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. In order to obtain warranty service, simply contact the nearest Authorized Genano Service Location. It is suggested that for your protection you return shipments of products by insured transport, insurance prepaid. Damage occurring during shipment is not covered by this warranty. NOTE: No other warranty, written or oral, is authorized by Genano Ltd Finland. This warranty gives you specific legal rights, and you may also have other rights which vary from country to country. Some countries do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion and limitations may not apply to you +. 1. Never operate this device if it has a damaged cord or plug, if it has been dropped or damaged. Return the device to an Authorized Genano Service Location for examination and repair. 2. Keep the cord away from heated surfaces. 3. Never drop or insert any object into any opening. 4. Do not plug in this air cleaning device outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered. 5. Do not use this device with a damaged or broken part, as injury may occur. 6. Always attach plug to device first, then to outlet. Be certain that plug is inserted firmly into device. To disconnect, turn device off, then remove plug from outlet. 7. To prevent possible damage to the cord, do not wrap cord around the air cleaning device. 8. Never put air cleaning device in direct, hot sunlight or store in pouch at a temperature above 140 F (60 C).

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 13 IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this appliance. When using an electric air purifier device, basic precautions should always be followed, including the following: DANGER To reduce the risk of electric shock: 1. Do not reach for a plug of an air purifier device that has fallen into water. Disconnect power at main source then unplug immediately. 2. Do not use in close vicinity while bathing or in a shower. 3. Do not place in heavily moist atmosphere, water or other liquid. 4. Do not place or store an air purifier device where it can fall or be pulled over. 5. Unplug this air purifier device before moving or transport to another location. 6. When discarding material used in this air purifier device, follow instructions issued by local authorities for disposal. 7. Ensure that wall socket is grounded. 8. Lock the bottom basin when G310 is operated near children or pets. WARNING To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Supervision is necessary when operated near children or the disabled. 2. Use this air purifier device for its intended indoor use, only, as described in manual. Do not use attachments not recommended by Genano Ltd. 3. Never use in an area with heavy wood dust or explosive chemicals. READ OWNERS MANUAL CAREFULLY! Manufactured for: GENANO LIMITED (FINLAND)

TT /JSan GENANO 310 OPERATING INSTRUCTION Page 14 Troubleshooting guide Warning! Repairs and maintenance work must be carried out by qualified personnel only. SYMPTOM The power does not turn on. Check connection to the mains. Check that power is switched on. Check the service door is not open. CORRECTIVE ACTIONS The green WASH-light is on when device is not washing. Wait until the drying period is over. If after a few hours the unit does not restart then reset the system If error continues after resetting contact an authorized repair service Red SERVICE/ERROR-light is continuously on. Wait several hours. Execute Power-wash. Reset default program settings (Switch the unit OFF and wait about 20 seconds then restart). If error continues after resetting contact an authorized repair service. Device is leaking water. It is possible that device leaks water if transported horizontally. Wait 8 hours before first use. Check that the flush water basin is in its place. Empty basin if necessary If leaking continues contact an authorized repair service. Operating lights are not functioning. Check connection to the mains. Check that power is switched on. Reset program settings. Increase water light is not working when the water tank is empty. Contact an authorized repair service. Airflow through the device is poor or it smells of metallic gases. Turn device off and contact an authorized repair service.