BA2702-P Linear Actuator

Similar documents
BA4000 Series Curtain Machine

Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

AX51 with Munters Drive

RC Series Discharge Cones

BI28SP Ceiling Inlet. Instruction Manual. BI28SP Ceiling Inlet. Bi-Flow, Spring Actuated. Models: BI28SP BI28SP-01

Flatsided Discharge Cone Models: 54GC & 54GCX

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans

MD Munters Drive. Instruction Manual. Munters Drive * Motor and Controller Replacement Kit. Motor & Controller Replacement kit for AX and VX Fans

IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

VX51 and VX55 with Munters Drive 51 and 55 Exhaust Fan

AIR HEATING PRODUCTS

Manual for use and maintenance. + CE Declaration of conformity. TU600 - TU800 Chimney fan. Ag/MIT/UmGB /14 rev 1.0

Positive Pressure Filtered Swine Facilities

WDP. Installation manual WDP. Gutter system. Ag/MIT/UmEN /14 rev 1.0

STT 3000 Series STT250 /150 Surge Protection Device Specifications

M I S T E L I M I N AT I O N. Mist elimination in Flue Gas Desulphurization. The buck stops here.

MFS. Manual for use and maintenance. + CE Declaration of conformity MFS. Air circulation fan. Models: MFS36 - MFS52. Ag/MIT/UmGB /13 rev1.

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Evaporative Humidifier/Cooler FA6 for AHU s Technical manual FA6. HC/MMA/TGB /10 pdf SOS ReklamStudio

Beckhoff short profile

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

High performing temporary space heaters

14" - 24" CLASSIC Direct Drive Fans

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

FieldLink Cable solutions for Automation & Drives

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Contents. Introduction. Introduction About This Report 1. Sustainability & Strategy. Social Respect for Human Rights and Diversity 15

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

JAZ. Operator s Manual. Diesel/Kerosene Air Heaters JAZ 42 JAZ 80 JAZ 80 W JAZ 125 JAZ 160

Shredders from Metso. Lindemann Eta Shred

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Accuracy counts! Sensors with analog output

Waterpik Water Flosser Model WF-02

EQUIPMENT Operation Manual

Crushers from Metso Recycling. Metso EtaCrush

OneWireless Gauge Reader WGR400 Series Specifications 34-XY July 2009

Installation Instructions

MVX 2000 Multivariable Pressure Transducer. Specifications 34-SM March Introduction. Proven Sensor Technology. Flow Computer Benefits

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

PTG, SWT Series. Heat Recovery Systems

CRA24-B3 controlled residential ventilation

Signal converters SVE4 Product overview

LC-3DPRINT BOX. Instruction For Use. LC-3DPrint Box

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

E + M III. Suitable for interfaces. up to CATEGORY 4 per EN E197638

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Instruction Manual GP110 GelPump

Spiral dewaterer. Optimal for dewatering of solids in water treatment systems

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

Product catalogue. Solutions for the Dairy segment

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Labeling and Identification Products

Advantages of automatic boiler bottom blowdown

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Corning LSE 6L Digital Water Bath

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

24 & 30 Quiet Design Oscillating Wall Mount Fan

International standards used locally worldwide ISO/TC 67

Seals for rotary equipment. Superdeal and Goodeal TM

Compressor Kit for ToughTek F340e Fireproofing Pump

EQUIPMENT Operation Manual

AutoM Click to go to the page. AutoM Auto Shaker Filter

Chloride FilterPro Power Filter (7 Amps)

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

BUILD the clinic you ve always imagined.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

STANDARD T6 (200 C) SENSOR CABLE RANGE

Battery Industry EFFICIENT APPLICATIONS SOLUTIONS

EQUIPMENT Operation Manual

Fire-Resistant. Automatic Doors

Window Accessories Whitmatic

Waterpik Water Flosser Model WP-450/462/ 463/465/470

ED Range Condensate Drains. Reliable, energy efficient removal of compressed air condensate

IMPORTANT SAFETY INFORMATION

WORLDS MOST ADVANCED ANTI-PRY DESIGN 2018 PRODUCT CATALOGUE

Waterpik Water Flosser Model WP-150/152

Security Trade Control by a Japanese company. 20 July, 2017 Shozo HIRATA NEC Corporation

... Desiccant Cartridges Conventional and Oil Separator Cartridges (OSC) ... products derived from proven Knorr-Bremse Technology. Product Information

Waterpik Water Flosser Model WF-06

Future development of the furniture industry A look at the next 3-5 years

Laundry. a wide range of automatic peristaltic dosing systems. innovation > technology > future

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

Model CAC 500M Media Air Cleaner

Installation & Operating Instructions

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

Pure Glass. saturn.clipsal.com

Pet Hair Eraser CORDED HAND VACUUM USER S GUIDE 87R4 SERIES V. Product View. Assembly. Operations. Maintenance and Care.

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

USER S OPERATING AND INSTRUCTION MANUAL

Owner's Manual. Voltage Converter. Reverse. 110V to 220V STEP UP. For International Power Connectivity Converts U.S. 110V to Foreign 220V

Metso in filtration. Mechanical dewatering by pressure

MUNTERS SERVICE GUIDE. Service, maintenance & upgrades. Your Trusted Global Service Partner

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

TAYAMA PREDICTS THE FUTURE OF WORLD CUT FLOWER PRODUCTION

This is azbil. A Company Shaping the Future with Automation

Transcription:

Instruction Manual Linear Actuator with Potentiometer BA2702-P Linear Actuator Model: BA2702-P QM1246r0 1

BA2702-P Linear Actuator Instructions for Use and Maintenance Thank You: Thank you for purchasing a Munters Linear Actuator. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service. Please Note: To achieve maximum performance and insure long life from your Munters product it is essential that it be installed and maintained properly. Please read all instructions carefully before beginning installation. Warranty: For Warranty claims information see the Warranty Claims and Return Policy form QM1021 available from the Munters Corporation office at 1-800-227-2376 or by e-mail at aghort.info@munters.com. Conditions and Limitations: Products and Systems involved in a warranty claim under the Warranty Claims and Return Policy shall have been properly installed, maintained and operated under competent supervision, according to the instructions provided by Munters Corporation. Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation or maintenance shall not be considered a defect under the Warranty. 2 QM1246r0

Index Chapters Page 1. Unpacking the Equipment 4 1.1 Parts List 4 1.2 Dimensions 4 2. Installation Instructions 5 3. Electrical Wiring 7 4. Open Limit Switch Adjustment 9 QM1246r0 3

Unpacking the Equipment 1. 1.1 Parts List Before beginning installation, check the overall condition of the equipment. Remove packing materials, and examine all components for signs of shipping damage. Any shipping damage is the customer's responsibility and should be reported immediately to your freight carrier. Each BA2702-P includes: 1 - Linear Actuator with Potentiometer 1 - Power connection cable, 4 wire 1 - Potentiometer connection cable, 3 wire 2 - Mounting Bracket Bases 2 - Holding Clamp Bracket 1 - Hardware Package: Hardware Package for BA2702-P ID Qty. Cat. No. Description [A] 8 --- M6 x 40mm Socket Head Bolt [A] Actuator Specifi cations Power: 110-120 VAC Amps: 1.43 Phase: 1 Frequency: 60 Hz Load Capacity: 750 lbs. 1.2 Machine Dimensions 37 5 8 Full Close 61 5 8 Full Open 6 1 2 Note: These actuators are designed to open or close Aero-Baffle, Munters modular-inlets or curtains accordingly from signals received from any one of Munters Air-Monitor Controls or Environmental Computer Controls. 4 QM1246r0

Installation Instructions 2. 1.1 Installation Step 1 Install the Vent Machine in the location specified on your ventilation system drawing. Vent Machine must be attached to structure capable of withstanding a load capacity to 750 lbs. [340 kg]. Step 2 Fasten the 2 Mounting Bracket Bases to a 2x8 or other framing, 16 O.C. in line with the main cable for the inlets and secure with lag screws (not provided). See Figure 1. 16 O.C. Mounting Bracket Base 2x8 or other framing Lag Screw (not provided) Figure 1 QM1246r0 5

Chapter 2 Installation Instructions Step 3 Place the Vent Machine in the Mounting Bracket Bases and secure in place using (2) Holding Clamp Brackets and (8) Socket Head Bolts [A]. See Figure 2. Vent Machine Mounting Bracket Base Socket Head Bolt [A] Holding Clamp Brackets Figure 2 Step 4 Loop Main Cable through hole in end of Vent Machine and fasten to itself as shown. See Figure 3. End of Vent Machine Cable Thimble Cable Clamps Figure 3 Main Cable 6 QM1246r0

Electrical Wiring 3. Step 5 All wiring should be in accordance with National, State and Local electrical codes. Attach 3 wire connection cable and 4 wire connection cable quick connect ends to Vent Mancine in the appropriate location. See Figure 4.! WARNING High Voltage, disconnect power before servicing. Vent Machine 4 Wire cable Electrical Connections 3 Wire cable Figure 4 QM1246r0 7

Chapter 3 Electrical Wiring Step 6 Connect the Power cable (4 wire) and Potentiometer (3 wire) to the computer control as shown. See Figure 5.! WARNING High Voltage, disconnect power before servicing. Vent Machine Bottom Cover Potentiometer Cable (3 Wire) Black ( ) Yellow (L) Red (+) Green (Ground) White (Neutral) Red (Open) Black (Close) Power Cable (4 Wire) Figure 5 8 QM1246r0

Open Limit Switch Adjustment 4. Close Limit Switch is preset, attach inlets to Vent Machine in the close position. Step 7 Using the Computer Control run the Vent Machine to the desired maximum open position. Step 8 Remove the Vent Machine Bottom Cover Step 9 Loosen the screw in the center of the White Plastic Cam (next to the Limit Switch). Step 10 Adjust the upper portion of the White Plastic Cam so that the extended point engages the Limit Switch. Step 11 Retighten the screw in the center of the White Plastic Cam. Step 12 Test Vent Machine by using the manual mode (close/open) of the Computer Controller. Extended Point on Cam --> White Plastic Cam --> Limit Switch QM1246r0 9

BA2702 Vent Machines are developed and produced by Munters Corporation, Lansing, Michigan U.S.A. 1-800-227-2376 Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE-164 26 Kista, Sweden. Phone +46 08 626 63 00, Fax +46 8 754 56 66. Munters Corporation 2691 Ena Drive Lansing, MI 48917 U.S.A. Phone +1 800-227-2376, Fax +1 517-676-7078 www.munters.us Australia Munters Pty Limited, Phone +61 2 6025 6422, Brazil Munters Brasil Industria e Comercio Ltda, Phone +55 41 3317 5050, Canada/US Munters Corporation Lansing, MI Phone +1 517 676 7070, China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481 121, Denmark Munters A/S, Phone +45 9862 3311, India Munters India, Phone +91 20 3052 2520, Indonesia Munters, Phone +62 818 739 235, Italy Munters Italy S.p.A., Chiusavecchia, Phone +39 0183 52 11, Japan Munters K.K., Phone +81 3 5970 0021, Korea Munters Korea Co. Ltd., Phone +82 2 761 8701, Mexico Munters Mexico, Phone +52 818 262 54 00, Russia Munters AB, Phone +7 812 448 5740, Singapore Munters Pte Ltd., Phone +65 744 6828, South Africa and Sub-Sahara Countries Munters (Pty) Ltd., Phone +27 11 997 2000, Spain Munters Spain S.A., Phone +34 91 640 09 02, Sweden Munters AB, Phone +46 8 626 63 00, Thailand Munters Co. Ltd., Phone +66 2 642 2670, Turkey Munters Form Endüstri Sistemleri A.Ş, Phone +90 322 231 1338, USA Munters Corporation Lansing, MI Phone +1 517 676 7070, Vietnam Munters Vietnam, Phone +84 8 3825 6838, Export & Other countries Munters Italy S.p.A., Chiusavecchia Phone +39 0183 52 11 10 QM1246r0