Heat Recovery Unit HERU web-version
HERU 50 and 75 Heat recovery unit HERU is designed to suit places like houses, offices and other buildings where there is a big demand for high temperature efficiency, low energy consumption, quiet operation and high reliability. HERU can be mounted in a warm or cold area, as it is insulated with 50 mm mineral wool covered on both sides with pre-galvanized sheet metal. The unit is equilateral why it can be connected from any side. > Efficiency 77 79 %. > Rotating heatexchanger made in aluminium, centrally placed in the unit. > Radialfans with B-wheels and external rotor motor, easy to remove and clean. > Bagfilters class F5 or F7. (F7 for standard). > Pressure switches indicating dirty filters. > Control unit. 2 HERU 180 Heru 180 has the same design as HERU 50 and 75, but a higher capacity and more features. > Efficiency 82 84 %. > Programmable timer for full/half speed. > Adjustable thermostat for starting/stopping the rotor. > Adjustable thermostat that stops the unit at too low inlet air temperature. > Pressure switches indicating dirty filters. > 7-step transformer for individual adjustment of the fanspeed. > Bagfilters class F5 or F7. Accessories: > Electrical duct heater with pulser. > Hot water battery with 3-way valve and control equipment. > Cold water battery with 3-way valve and control equipment.
HERU 180 S HERU 180 S is the best equipped heat recovery unit we produce. With HERU 180 S you are controlling the inlet as well as the outlet temperature to get the most accurate temperature. HERU 180 S is prepared for connection to hot/cold water battery* *Data, see page 7. Accessories for HERU 180 S > Electrical duct heater (5 kw) with pulser. > Hot water battery (5 kw) with 3-way valve and control equipment. > Cold water battery (2,5kW) with 3-way valve and control equipment. > Damper actuator. > Room sensor with set point. Features for 50, 75 & 180 Control equipment for HERU 180 S The control equipment consists of regulator, microprocessor controlled, with following functions: > Full/half speed. > Constant inlet air temperature or room regulating of the temperature. 1=rotor off/on. 2=rotor off/on and duct heating in sequence. 3=rotor off/on duct heater and cool water battery in sequence. > After-heat from el. or hot water battery. > Cooling from cool water battery. > Filter pressure governor. > 7-step transformer for individual adjustment of the fan speeds. > Set point adjustment. > Reading temperatures and temperature efficiency. > Input for extended operating time. > Input for smoke detector,which stops the unit and shuts the damper. > Filter governor alarm and frost protection limiter. > Connection for buzzeralarm. HERU s exceptionally high efficiency can be traced to the exchanger. Normally this type of exchanger can only be found in much more expensive units. A combination of area and material gives this exchanger its superior qualities. The air flow in Heru is regulated by two dependable and quiet running radial fans. The fans are connected with quick switches and are easily removed for cleaning. 3 Because the walls are insulated with 50mm mineral wool the Heru can be placed in a warm or cold area, according to need.
Measurements HERU 50 and HERU 75 Measurements HERU 180 and HERU 180 S 4 Technical data HERU 50 HERU 75 HERU 180/180 S Voltage Current Power Frequenzy Weight Connections 230V 0,58A 132W 50Hz 63 Kg Ø160 mm Voltage Current Power Frequenzy Weight Connections 230V 0,90A 200W 50Hz 63 Kg Ø160 mm Electric connection: Plug directly to earthed terminal. Operating central: All connections to be made by an authorized electrician Voltage Current Power Frequenzy Weight Connections 230V 1,87A 403W 50Hz 130 Kg Ø250mm
Pressure and flow HERU 50, F7 filter HERU 75, F7 filter Flow m 3 /h Flow m 3 /h Static pressure, Pa Static pressure, Pa 1 = min 2 = normal 3 = max Flow m 3 /s Flow m 3 /s HERU 180, F5 filter Flow m 3 /h HERU 180, F7 filter Flow m 3 /h Static pressure, Pa Static pressure, Pa 5 Flow m 3 /s Flow m 3 /s Transformer curves HERU 180 Curve no 1 2 3 4 5 6 7 100V 130V 150V 170V 190V 210V 230V
Sound data HERU 50 and HERU 75 Flow/ Position of LpA LwA Static pressure measuring db(a) tot 63 125 250 500 1k 2k 4k 8k To environment 31 38 34 31 32 32 29 26 28 30 HERU 50 41 l/s 110 Pa Inlet 63 50 54 54 58 57 54 50 36 Outlet 49 42 44 41 44 38 33 33 18 To environment 38 45 35 37 40 41 35 31 30 30 HERU 75 60 l/s 100 Pa Inlet 66 47 56 59 61 60 56 51 37 Outlet 51 39 47 43 47 39 30 22 9 Sound data HERU 180 and HERU 180 S 6 Inlet Outlet To environment Flow/ Position of LpA LwA Static pressure measuring db(a) tot 63 125 250 500 1k 2k 4k 8k 180 l/s 110 Pa Inlet 75 61 67 68 71 66 60 55 45 155 l/s 200 Pa Inlet 74 57 66 68 71 65 60 55 44 125 l/s 300 Pa Inlet 76 55 67 69 73 66 60 55 45 80 l/s 415 Pa Inlet 77 54 66 71 74 66 60 55 45 180 l/s 110 Pa Outlet 60 47 55 54 55 47 39 25 9 155 l/s 200 Pa Outlet 61 47 54 56 57 48 40 26 9 125 l/s 300 Pa Outlet 62,5 46 57 57 58 48 41 27 11 80 l/s 415 Pa Outlet 63 46 53 58 60 50 41 28 13 230 V 100 Pa To environment 45 52 39 42 46 47 42 44 41 39 190 V 100 Pa To environment 45 52 37 40 45 47 41 43 40 38 170 V 100 Pa To environment 43 50 36 41 44 45 40 41 39 38 150 V 100 Pa To environment 42 49 36 39 43 46 37 37 37 37 Explanations to sound data The sound data have been compiled by means of sound measurement methods as follows: Pressure and flow: ISO 5801 Determination of acoustic sound level in duct: ISO 5136 Determination of acoustic sound level in reverberation room: ISO 3741 Designations L WA tot: Total A-weighted sound power level db(a) (ref 10-12 W)=the sum of the sound power level in the octave ranges. L WA : A-weighted sound power level in octave range db(a) (ref 10-12 W). L pa : A-weighted sound pressure level in db(a) according to normed A-weightening correction and relating to an effective absorption area of 20 m 2 with half spherical translation at a distance of 3 meters.
Accessories for HERU 180 ELECTRICAL DUCT HEATER (5 kw) CIRCULAR DUCT HEATER FOR HOT WATER (5kW) Water battery data - hot water Air Hot water Flow Speed Input temp Output temp Power 0,2m 3 /s 2,2 m/s 10 C 30,5 C 5kW Flow Speed Input temp Output temp Pressure drop 0,1 l/s 0,86 m/s 60 C 40 C 15kPa 7 CIRCULAR DUCT COOLER FOR COOLING WATER - (2,5 KW) Water battery data - cooling water Air Cold water Air Cold water Flow Speed Input temp Output temp Power 0,2m 3 /s 2,2 m/s 25 C, 50%Rh 14,4 C 2,5kW Flow Speed Input temp Output temp Pressure drop 0,16 l/s 0,8 m/s 7 C 12 C 12,4kPa Flow Speed Input temp Output temp Power 0,15m 3 /s 1,7 m/s 25 C, 50%Rh 13,5 C 2kW Flow Speed Input temp Output temp Pressure drop 0,13 l/s 0,6 m/s 7 C 12 C 8,8kPa