TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

Similar documents
TTV 4500 / TTV 4500 HP / TTV 7000

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TDS 20 R / TDS 30 R / TDS 50 R

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

TCH 2000 E OPERATING MANUAL DESIGNER GLASS CONVECTOR TRT-BA-TCH2000E-TC-001-EN

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

TDS 100. EN Operating Manual Electrical Fan Heater

PAC 2600 E OPERATING MANUAL PORTABLE AIR CONDITIONER TRT-BA-PAC2600E-TC-001-EN

B 400. Operating Manual Humidifier B 400

AW 20 S OPERATING MANUAL AIR WASHER TRT-BA-AW20S-TC-004-EN

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

PAC 2000 E OPERATING MANUAL LOCAL AIR CONDITIONER TRT-BA-PAC2000E-TC EN

TTK 1500 OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK1500-TC-001-EN

PAE 50 OPERATING MANUAL AIR COOLER TRT-BA-PAE50-TC EN

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

GLEB Kitchen exhaust fan

Waste water ejection unit

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

OPERATION AND MONTAGE MANUAL ROOF FANS

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

OPERATION AND MONTAGE MANUAL ROOF FANS

SHORT WAVE INFRARED PANEL DRYER

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Whole Room Dryer WRD, WRD/110

Universal vacuum. Operation Manual LS 5000 ESW. Machine no. Models. Universal vacuum LS 5000 ESW Original Operation Manual

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless

Operating Manual. VIENNA Hot Display

Kitchen Appliance Lift INSTRUCTION MANUAL

en Inverter FU 4/5. Operator s Manual

Operation Manual 322 KL

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

FHA 1100 A1 Domestic Water Pump

Operator s manual. Battery charger C 48/ en / 03

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

Instruction Manual. Electronic gas and smoke detector GRM

Copyright LIQUIDYN GmbH 08/2013 Version

Tempest TP420/180 Electric Pressure Washer

Instructions for Use

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

EHA Hoffmann International GmbH

Commercial backpack vacuum cleaner

IEC- Direct-driven radial fans with IEC-Standardmotor

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202

wan Travel Kettle designed for life For model: SK27010N v3.2 SK27010N.indd 1 12/02/ :12

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

Original Operating Instructions V-VTE

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Trotec PAC FT 2600 Portable air conditioner

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

KK70 Silent. Installation and Operating Instructions L V001

USER S MANUAL ATH WH220

RX550i Electric Pressure Washer

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions

Sip Vacuum Cleaner 1400/35 Wet & Dry

Panel Fan Series Operators Manual (Galvanized and Polymer)

Operating Instructions

DanVex AD-200 Adsorption air dehumidifier. Operation manual

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

NHS VERTICAL AGITATOR

K M. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

Operation Manual. Trash Water Pump ARTICLE Image similar

Operation Manual Airbrush Compressor AH28A ARTICLE 34247

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Models: RP-10, RP-15, RP-20. User Manual

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Kettle v1.2. Models: SK (all models) Helpline:

USER S AND MAINTENANCE MANUAL AUTOMATIC MOUNTING PRESS

Air handling unit. BlauAir RH USER S MANUAL

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Operation Manual. Pond Pump Series HJ and CQP

Original Operating Instructions V-VC

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

DEVIL CERAMIC SPACE HEATERS

Oscillating Belt/Spindle Sander 230V

Installation and assembly instructions. for standard configuration radial blowers

Operating Instructions

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

OPERATING & MAINTENANCE INSTRUCTIONS

K 5.80 M ( ) Caution! Do not use the unit without first having read the operating instructions.

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:...

Transcription:

TFV 900 EN OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

Table of contents Notes regarding the operating manual... 1 Safety... 2 Information about the device... 3 Transport and storage... 4 Start-up... 4 Operation... 5 Errors and faults... 6 Maintenance... 6 Technical annex... 7 Notes regarding the operating manual Symbols Hazardous electric current! Warns about hazards from electric current which can lead to injuries or even death. Danger! Warns of a hazard which can result in moderate to severe injuries. Caution! Warns of a hazard which can result in minor injuries or property damage. Wear hearing protection! Indicates the activities during which hearing protection is to be worn. TFV 900 The current version of the operating manual can be found at: http://download.trotec.com/?sku=1510002050&id=1 Legal notice This release replaces all previous versions. No part of this publication may be reproduced without written permission from Trotec. The same applies for electronically processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registered. Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour are reserved. The scope of delivery may vary from product images. This document was created with all due care. Trotec accepts no liability whatsoever for possible mistakes or omissions. Trotec Warranty and liability Damages caused by incorrect use by untrained people or start-up by unauthorised people are excluded from the warranty. The device complies with the fundamental health and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times. However, if faults in the functionality occur and cannot be remedied with the measures in the chapter Errors and faults, please get in touch with your dealer or distributor. When invoking the guarantee, the data given on the fan info sheet supplied with the device is to be quoted. When manufacturer's instructions or legal regulations have not been followed, or after unauthorised changes to the device are made, the manufacturer is not responsible for the resulting damages. Changes to the device or unauthorised replacement of individual parts can drastically impact the electrical safety of this product and leads to the forfeit of the warranty. Liability does not extend to damages to people or property caused by the device being used other than as described in the instructions in this operating manual. Subject to changes to technical design and model changes as part of constant development and product improvement without prior notice. No liability is accepted for damages resulting from improper use. In such cases, entitlements to a warranty are then also forfeited. EN Operating Manual Radial Fan TFV 900 1

Safety Carefully read the operating manual before using the device and keep it within reach! Danger! Improper handling can lead to injuries due to parts being whirled up. Do not use the device in rooms with a fire hazard or in potentially explosive rooms and do not install it there. The device is optionally also available for the operation in ex-proof areas and only these devices may be operated in an explosive environment. Only put up the device in an upright, stable position on firm ground. Ensure that the air inlet and outlet are not obstructed. Make sure that there are no loose items located in the immediate surroundings of air inlet and air outlet. Never reach or put objects into the device. Do not transport the device during operation. Ensure that all electric cables outside of the device are protected from damage (e.g. from animals). Never use the device if the cable or power connection is damaged! Only use connecting cables which are appropriate to the device power consumption, the length of its cable and its use. Avoid electrical overload. Connection cables must always be reeled off completely. Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition. Observe the storage and operating conditions (see chapter Technical data). Unplug the device from the mains before starting with maintenance, service or repair work. Only use original spare parts, for otherwise safe and functional operation cannot be ensured. Intended use The radial fan TFV 900 may be used for the large-scale ventilation of channel and pipe or tunnel systems, during welding work or sealing and floor coating in underground working, whilst adhering to the technical data and the safety instructions. The radial fan was designed for large volume flows of atmospheric air, also through connected air transport hoses over very long transport routes with high a counter-pressure. All other applications are considered improper use. Improper use The radial fan TFV 900 is not suited for installation in fluids or on flooded or boggy grounds. The device must not be used for transporting media other than atmospheric air, e.g. fluids or other gases. Any unauthorised changes, modifications or alterations to the device are forbidden. Personnel qualifications People who use this device must: be aware of the dangers that occur when working with high-pressure fans. have read and understood the operating manual, especially the Safety chapter. Electrically skilled person Electrically skilled personnel must be able to read and understand electric circuit diagrams, to put electrical systems into service and to maintain them, to wire control cabinets, to ensure the functionality of electrical components and to identify possible hazards from electrical and electronic systems. Instructed person Instructed persons have been informed of the tasks they were entrusted with as well as of potential hazards resulting from inappropriate behaviour. They are allowed to operate and transport the device and perform simple maintenance activities (cleaning the housing, cleaning the fan). The device is to be maintained and looked after by instructed personnel. Personal protective equipment Wear hearing protection! Wear hearing protection when spending a longer period of time in the vicinity of the device. Residual risks Hazardous electric voltage! Work on the electrical components must only be carried out by an authorised specialist company! Hazardous electric voltage! Before any work on the device, remove the mains plug from the mains socket! Danger due to strong air current! Risk of injury from parts being whirled up. Before switching the device on, make sure that there are no loose parts located near air inlet or outlet! Danger! Improper handling entails a risk of injury. Only use the device as intended! Danger! Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications! Behaviour in the event of an emergency 1. Immediately switch the device off via the emergency stop switch at the upstream distributor or the main switch at the device. 2. Remove persons from the danger area. 3. Disconnect the device from the electric circuit. 2 Operating Manual Radial Fan TFV 900 EN

4. Do not reconnect a defective device to the mains power. Information about the device Description of the device The high-pressure radial fan TFV 900 conveys up to 25,000 m³/h of air even over long hose distances with high counter-pressure. Freely blowing the devices reaches values of up to 33,600 m³/h. The fan motor is located outside of the main air stream and so enables the operation even in dusty surroundings. The device is splash-proof and suited for use outside under rough and aggressive surrounding conditions. The device can be connected to both intake and exhaust ducts. The device is provided with a star-delta connection for smooth start-up. In the standard version the device is delivered without a frame for stationary application. Optionally the device is also available with a frame (as depicted) for variable areas of use. As for a further option the device is also available as ex-proof version for the use in potentially explosive surroundings; only these devices may be operated in an explosive environment. The radial fan is integrated in a powder-coated steel housing with highly resistant two-component finish. The device is designed ready-to-install, the power box contains the relevant control and monitoring components for safe and functional operation. Device depiction 8 6 7 No Designation. 1 Frame (optional) 2 Crane lifting lugs (frame option) 3 Motor 4 Power box with control panel and mains connection with CEE plug 32 A 5 Air exhaust connection 6 Forklift pockets (frame option) 7 4 castors, lockable (frame option) 8 Air intake connection 1 2 3 4 5 6 EN Operating Manual Radial Fan TFV 900 3

Transport and storage Remove all packing materials which serve to protect the device during transport. Should the device be damaged, please contact the responsible dealer or manufacturer, where the purchase was made. The device with frame may only be lifted at the points provided with lifting gear (forklift pockets (6), crane lifting lugs (2)). The carrying capacity of the lifting gear must be suitable for the weight of the device (see Technical data). The device without frame may only be lifted at the lifting lugs provided at motor and fan. The carrying capacity of the lifting gear must be suitable for the weight of the device (see Technical data). For transport with a forklift drive in from the motor side, that's where the centre of gravity is to be found. The other forklift pockets are for the later fine adjustment on site. Only wheel the device with frame on firm, level ground. Make sure that nobody is situated in the direction of movement. Avoid pulling the device, this increases the risk of tripping and injury. The following should be observed before transporting the device using the castors: Caution! Trip hazard! Make sure that nobody is situated in the immediate proximity. The following should be observed before transporting the device using lifting gear: Danger! Risk of injury from suspended loads. Make sure that nobody is situated in the immediate proximity. Start-up Installation of the device Position the device on firm, dry and level ground. Depending on the permissible floor load capacity a panel for weight distribution may be required. When setting up the device, ensure a sufficient distance for air inlet and outlet as well as for operation (see Technical data). Ensure that extension cords are completely unrolled. Option with frame: Apply the parking brakes prior to start-up and secure the device against rolling away. The following points are to be checked before start-up: Make sure that both air inlet and air outlet are free from objects and/or obstacles. Manually check the freewheeling of the fan: Carefully rotate the rotor by hand, it should not rub against the housing. Connect the required air transport hoses with suitable tension belts with clamping lock to the air intake connection (8) or as needed to the air exhaust connection (5). Compare the values of the power connection to the technical data of the TFV 900. Observe the starting current of the device, the upstream fuse must be dimensioned accordingly. Before connecting the device to the mains, check the rotary field: clockwise rotating field required! First connect the fan plug to the power cable and then the cable to the distribution! Only instructed persons are allowed to perform the transport by use of lifting gear. Consider the centre of gravity when transporting the load. Storage Store the cleaned device in a dry location and protect it against dust. Before restarting the device, check the power cable for perfect condition. 4 Operating Manual Radial Fan TFV 900 EN

Operation Control panel 9 10 11 Switch-off 1. Press the red Control off button (12). The Operation lamp (10) goes out. The fan resumes in rundown operation for a few seconds and then comes to a halt. From this operating condition you can switch the device back on at any time. Shutdown 1. Switch the device off as previously described. 2. Upon standstill of the fan (wait for the end of the rundown operation!) turn the main switch (9) to position 0. 3. Now first pull the plug from the mains and only after that disconnect the plug connection directly at the device. 13 12 Power box The following components are located in the power box: No. Designation 9 Main switch 10 Operation lamp 11 Fault lamp 12 Control off button 13 Control on button Switch-on 1. Turn the main switch (9) to position I. The control unit is activated. The device is ready for operation. 2. Check the fan's direction of rotation! To do so, briefly press the green Control on button (13) and immediately afterwards the red Control off button (12): the fan must be turning in the direction of the arrow. Observe the arrows at the housing, only then can proper fan operation be guaranteed! If the fan rotates contrarily to the direction of the arrow, check the rotary field directly at the power box. If the rotational direction is correct, the device can be switched on. 3. Press the Control on button (13). The Operation lamp (10) is illuminated. The fan starts up smoothly in star operation and after a little while switches over to delta. Hence it supplies its maximum conveying capacity for continuous operation. 18 14 17 16 No. Designation 14 Changeover contactors Q3 15 Main switch Q1 16 Star-delta changeover switch for smooth start-up K1 17 Terminals 1...11 18 Motor protection switch F2 with blue reset button 15 EN Operating Manual Radial Fan TFV 900 5

Errors and faults The accurate functionality of the device was tested during production a number of times. If malfunctions occur nonetheless, check the device according to the following list: Fault Cause Possible solution The motor does not start Missing mains Check the power connection. or automatically voltage switches off again after Operation lamp (10) Press the Control on a short period of time off button (13). Fault lamp (11) illuminated Check, whether the motor protection switch F2 (18) has tripped. The fan performance / air flow rate is not as expected Motor protection switch tripped Wrong rotational direction of the fan Investigate and eliminate the cause: Louvers not free Air resistance too high Air transport hoses blocked or bent Motor or motor bearing defective Power cable defective Foreign object in fan Upon elimination of the fault's cause: Acknowledge the fault at the motor protection switch by means of the blue reset button, then take the device back into operation. Check the rotary field and change it, if required. Have the electric installation checked and, if required, defective parts replaced, but only by a qualified electrician. Repair work may only be performed by qualified electricians or Trotec. Maintenance Trotec radial fans are designed for long hours of operation with minimum maintenance effort. Safe operation of the device requires all built-in components to be checked and cleaned after 6 months at the latest or after every 4000 operating hours as well as all damaged components to be replaced. Observe the lubrication and maintenance intervals as indicated on the fan info sheet. Activities required before starting maintenance Do not touch the mains plug with wet or damp hands. Wait for the end of the rundown period if the device was in operation beforehand. Switch off the device at the main switch. Before any work, detach the mains plug! Repair work may only be performed by qualified electricians or Trotec. Cleaning the fan You may use compressed air for a thorough cleaning of the fan. Do not use a high-pressure cleaner for the fan! Always pay attention to unusual sounds, if in doubt, consult the manufacturer. 6 Operating Manual Radial Fan TFV 900 EN

Technical annex Technical data Parameter Value Type TFV 900 Article number 1510002050 Air volume flow - freely blowing - at an air pressure of 1,900 Pa 33,600 m³/h 25,000 m³/h Air discharge velocity 34.0 m/s 122.4 km/h Fan stage 1 Max. air pressure 2,150 Pa Max. transport medium temperature 80 C Nominal voltage 3/N/PE~ 400 V / 50 Hz Rotary field clockwise rotating field Nominal current 32 A Recommended fusing 32 A gl Nominal capacity 18.5 kw Surrounding conditions - permissible temperature range - type of protection -20 C to +40 C IP 55 Mains plug CEE 32 A Engine start-up star-delta changeover Noise level (at a distance of 1 m) 82 db(a) Weight - without frame - option with frame 450 kg 920 kg Dimensions (height x width x depth) - without frame - option with frame Wiring diagram 1650 x 1200 x 1770 (mm) 2200 x 1950 x 1900 (mm) EN Operating Manual Radial Fan TFV 900 7

Illustration of spare parts Note! The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual. 1 19 14 15 8 3 4 5 7 6 9 10 18 17 16 11 13 12 List of spare parts No. Spare part Article no. No. Spare part Article no. 1 Frame 1510002051 10 SP lamp green TFV 900 7141000625 3 SP motor TFV 900 7110000043 11 SP lamp red TFV 900 7141000626 4 see separate list (9/15 to 13) 12 SP button red TFV 900 7130000092 5 SP air exhaust connection d=630mm 7230000002 13 SP button green TFV 900 7130000093 5b SP air exhaust connection d=600mm 7230000005 14 SP contactor control TFV 900 7140000122 7 SP castor TFV900 7600000245 16 SP changeover switch star-delta K1 TFV 900 7140000120 8 SP air intake connection TFV 900 d=630mm 7230000003 17 SP terminals TFV 900 7214000009 8b SP air intake connection TFV 900 d=600mm 7230000004 18 SP motor protection switch F2 TFV 900 7140000119 9/15 SP main switch TFV 900 7130000091 19 SP rotor fan TFV 900 7150000007 8 Operating Manual Radial Fan TFV 900 EN

Declaration of conformity (Translation of the Original) EC Declaration of Conformity in accordance with EC Machinery Directive 2006/42/EC Trotec GmbH & Co. KG Grebbener Straße 7 D-52525 Heinsberg herewith declares, that due to its design and construction, and in the version introduced by us, the following machinery conforms with the relevant fundamental requirements of the listed EC directives. Important note: In case of improper use, installation, maintenance etc. or unauthorized changes of the factory-supplied device version, this declaration loses its legal validity. Device version: radial fan Models: TFV 900 Year of manufacture: as of 2009 Applicable regulations: Applied harmonised standards: 2006/42/EC 2006/95/EC 2004/108/EC EN 12100-1/2:2007 EN 13857:2008 EN 60204-1:2006 Machinery Directive Low Voltage Directive EMC Directive EN 60034-1:2007 EN 60034-5:2001 + A1:2007 EN 50081-2 Producer and authorised representative of the technical documentation: Trotec GmbH & Co. KG Grebbener Straße 7 D-52525 Heinsberg Phone: +49 2452 962-400 Fax: +49 2452 962-200 E-mail: info@trotec.com Heinsberg, 13 August 2009 Managing Director: Detlef von der Lieck EN Operating Manual Radial Fan TFV 900 9

Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com