Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1

Similar documents
POWER SHOWERS Models 4500M 5002M 4500T 5002T

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Unvented Electric Water Heater 10/15 litre Undersink

Alpha CombiMax 350 and 600

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Installation and User Instructions HS10U, HS15U.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Mira Elite QT 9.8kW / 10.8kW

Thermostatic Bar Valves

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Please do not hesitate to contact us with any enquiries.

HEAVY DUTY BRASS SHOWER PUMPS

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Water Regulations Tutorial # 6 Conservation

Closomat Lima Vita installation & user guide

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

Powerflow Unvented water heater

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Installation Instructions Thermostatic Bar Shower Valve ALTO ECOTHERM

WHHR Midi & Midi Lite

Mira Sport Max with Airboost

Energy. Installation guide

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

Electric Showers Installation Instructions & User Guide

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

Manual and Thermostatic Power Shower Units

Rota- Station and Plus Instructions

Puro Mini Dual Control Shower Mixer PU90010CP

Self-help Temperature Adjustment

Rota- Station and Plus Instructions (Mega Part & )

Inta City Shower Mixing Valve CT20010CP

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Telo Shower Mixing Valve TL10016CP

Dual Control Concealed & Exposed Thermostatic Shower Valve

Installation, operating and servicing instructions

Installation Instructions and User Guide

Aqua Sprint AQS8 Electric Shower

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

Plus Bath Shower Mixing Valve CP and PL30020CP

Enzo Concealed Shower Mixing Valve

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

Kiko Bath Shower Mixing Valve KK90015CP

Electric Showers. Installation Instructions & User Guide. AQUA PROFILE PLUS AQP8 & AQP9 Electric Shower. 2 Year Guarantee

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2

Dual Control Thermostatic Bath and Shower Mixer

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Water Regulations Tutorial # 7 Washroom

Installation, Operating and Maintenance Guide

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Auto Drain Installation Instructions.

Deluge Shower Mixing Valve 10045CP

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

INSTANTANEOUS ELECTRIC SHOWER

Auto Drain Installation Instructions.

HOTFLO 10 / 15. Fitting Instructions and User Guide

SURFACE WARM CEILING HEATERS

Shower Panels with a Thermostatic Sequential Control

The Water Regulations Solutions Specialist

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

IS09 ECN2087. EB3, EB4 & EB6 Automatic Fill Water Boilers INSTALLATION, USER & SERVICING INSTRUCTIONS

Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel Fax

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

SMART SHOWERS ELITE SP P0985 READ ME THIS IS A HIGH PERFORMANCE HIGH SPECIFICATION PUMP AND HAS PRECISE INSTALLATION REQUIREMENTS

900 Quadrant Steam Shower Cabin with 6 Body Jets

Installation, Operating and Maintenance Guide

ZIP VARIPOINT II Direct unvented water heaters.

Streamline Undersink. Fitting Instructions and User Guide

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Installation Instructions Air Sourced 310 Heat Pump Module

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Varsity Concealed Shower System

Mio Concealed Shower Mixing Valve MI40010CP

Autofill counter top water boiler

Installation and Servicing Instructions. Alpha GasSaver GS-1

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Thermostatic bar mixer valve with adjustable head Installation guide

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

WATER BOILER METOS MARINE WKI MG MW,

PERFORMANCE SHOWER PRODUCTS

Rio & Kiva height adjustable bath

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

Mira Meta 8.5, 9.5 and 10.8 kw Electric Shower

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

Transcription:

Arrow Valves Ltd Operating & Maintenance Manual ABLUTION PLANT Arrow Valves Tel 01442 823 123 Fax 01442 823 234 www.arrowvalves.co.uk Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1 Model shown BTHW-1 FOREWORD The Ablution Plant provides Fluid Category 5 backflow protection and a boosted hot water supply at a safe temperature. The operation is automatic. Dry running pump and heater protection is via a low level float switch in the cistern. SUPPORTING LITERATURE BTHW Ablution Plant Datasheet TMV5213 Datasheet Wiring Diagram AM139* Factory Commissioning Certificate WARNING Disconnect electrical power before removing electrical cover guard for any servicing Page 1 of 6

SECTION ITEM 1.0 INSTALLATION 2.0 COMMISSIONING 3.0 OPERATION 4.0 MAINTENANCE 5.0 FLOW LIMITING CARTRIDGE 6.0 HIGH LIMIT RESET BUTTON 7.0 FAULT FINDING 8.0 SEIZED PUMP 9.0 FILLING SOLENOID 10.0 OPTIONS 1.0 INSTALLATION 1.1. The Ablution Plant should be installed by a competent person with regard to the relevant requirements of the Health and Safety Regulations, building regulations, IEE Regulations, Water Supply (water fitting). Water Bye-Laws (Scotland) and other local Bye-laws. 1.2. Do not install in a potentially freezing location or above 25⁰ C. 1.3. Wall mount the unit ensuring sufficient clearance below the cabinet to connect the overflow pipe. Secure using suitable fasteners or the optional wall bracket code MIDIBRA (see section 1.4 for instructions). Do not mount above electrical equipment or where any discharge could cause damage. An optional Drip Tray is available code BTDT3. 1.4. Instructions for installing optional MIDIBRA wall bracket: 1.4.1. Offer bracket to wall as a template. 1.4.2. Mark centres of top of the two keyhole slots and mark centres of other two holes. 1.4.3. Remove bracket, drill and fit wall plugs to the four holes. 1.4.4. Fit bracket to DF cabinet with the supplied M6 flanged nuts. 1.4.5. Fit cabinet to wall with suitable fasteners. 1.4.6. Consider fitting screws to two lower holes in the cabinet. 1.5. The plant weighs 50kg dry and 60kg wet. Safe lifting practises should be used. 1.6. Electrical supply must be via a double pole isolator and RCD. The cabinet features a 20mm entry for conduit. The unit requires a 230V 50 Hz supply fused at 13 A (or 16A MCB). The switch must have a double pole disconnection with a separation gap of at least 3mm. See ratings plate for electrical details. 1.7. Adequately support the supply pipe normally 15mm copper tube. 1.8. Thoroughly flush the cold water supply pipe before connecting. The water supply pressure must be 1.0 bar min. (dynamic) - 10 bar max. 1.9. The flexible hose and servicing valve incorporating a strainer and flow limiter - provided must be installed. 1.10. The Servicing valve assembly incorporates an automatic flow limiter and strainer. Note - If the dynamic pressure is too low and the tank is running dry, remove flow limiter cartridge from servicing valve see 4.0. 1.11. The overflow discharges into the bottom of the unit. Connect overflow pipe to the front connector. Ensure any discharge would be conspicuous and not cause any damage. The rear overflow is to prevent the cabinet from flooding in the unlikely event of the main overflow not coping this can be connected to waste. 1.12. Connect outlet pipe, and optional cold boosted outlet if using option BTHW-OP1. See Drawing AM141*. Note - If pipe run is greater than 5m, a remote TMV (BTHW-1RTMV) should be used. 1.13. The overflow should be in accordance with Water Regulations - G16.8, G16.10 & G16.11. WARNING! If the overflow cannot cope, water will discharge via the weir slot in the door. 1.14. If the minimum outlet flow rate of 0.008 Lt/s (0.5 Lt/min) cannot be guaranteed fit an additional pressure vessel of at least 4 litres (pre-charge 2 bar). Page 2 of 6

2.0 COMMISSIONING 2.1. The unit is factory commissioned, but the outlet temperature must be checked and the TMV adjusted as required. Note - it is not possible to alter the outlet pressure. The pump is selfpriming. 2.2. Turn water supply on. The solenoid valve should commence filling and cease filling when the tank is full. 2.3. Open a tap connected to the outlet system. 2.4. Switch on the electrical power. 2.5. When a tap is opened - or trigger of ablution hose depressed - the pump should start automatically. Continue to draw off water until all air has been purged from the system. If the pump does not start, isolate the electrical supply and investigate. Check the pump has not seized see 7.2. 2.6. Turn heater on. 2.7. Once the heater is up to temperature its red neon will extinguish, this will take approximately 10.5 minutes. Set the water heater thermostat to 62 C min - G18.2. To check, hold the probe of a digital thermometer against the hot metal outlet of the heater hose whilst water is being drawn off. 2.8. Set the outlet temperature to the required temperature, 41 C max. To adjust the temperature, prise off the plastic cover of the TMV, invert cover and use as an adjusting tool to rotate the hexagon spindle. A brass lock nut is provided for locking the desired temperature. The plastic cover should then be replaced. 2.9. The table below shows the recommended maximum temperatures for use - Bidet max recommended temperature 38 o C NHS Estates Health Guidance Note Shower - max recommended temperature 41 o C NHS Estates Health Guidance Note Page 3 of 6

3.0 OPERATION 3.1. When electrically powered and all water draw offs closed, the pump should be at rest. When a tap is opened - or trigger of ablution hose depressed - the pump should start automatically. There may be about 1 second delay before the pump starts. 3.2. When all taps are closed, the pump should automatically stop within 3 seconds. 3.3. For applications with a continuous draw off less than 0.008 Lt/s (0.5 Lt/min) a pressure vessel of at least 4 Lt (pre-charge 2 bar) must be fitted to the system otherwise pump damage will occur due to the continuous stop/start cycling and this will invalidate the warranty. 3.4. The plant contains a small storage tank and a legionella risk assessment should be conducted. The greatest risk is associated with aerosol applications e.g. shower heads. These should be operated periodically to purge stagnant water and replenish the internal tank and outlet pipe work. Note the Automatic Tank Purge Option (BTHW-OP2) can automatically purge the internal tank but not the outlet pipe work. 3.5. The unit must be run at least once every two weeks to exercise the pump by drawing off water from the boosted system. Ensure the pump runs for 2 minutes. 4.0 MAINTENANCE 4.1. Check the pump runs by drawing water off from tap or trigger. Check the filling rate can cope with the maximum demand. If low inlet flow is suspected check and clean the inlet strainer in the servicing valve. See AF068A diagram -. 4.2. Close valve. 4.3. Unscrew hexagonal cap. 4.4. Remove strainer cartridge with long nose pliers. 4.5. Remove flow limiter from strainer (if fitted) by pushing out with small screwdriver. 4.6. Clean or replace basket and cartridge, with the same size and colour. 4.7. Insert flow rate cartridge into strainer - push to limit. 4.8. Insert strainer into valve push to limit. 4.9. Replace hexagonal cap. 4.10. Turn valve on. 4.11. If the pre-charge air pressure in the 0.5 Lt vessel needs to be checked, we advise that an air pressure gauge should not be used as air will escape. Instead, the pressure should be checked with a pressure gauge on the outlet water pipe; where the sudden drop in pressure with a slow draw off (pump switched off) indicates the pre-charge pressure, which should be 2.0 ± 0.3 bar. 5.0 FLOW LIMITING CARTRIDGE 5.1. If the BTHW-1 is using an aeration trigger it may be necessary to change the flow limiting cartridge to enhance the flow characteristics of the water from the trigger. Please note that this will affect the duration that warm water can be provided. 5.2. To change the flow limiting cartridge: 5.2.1. Isolate the power and water supplies. 5.2.2. Drain the system as far as possible by holding the trigger open. 5.2.3. Separate the push-fit connector at the end of the braided hose inside the unit, on the right hand side of the unit just above the shelf. 5.2.4. Use bent nose pliers to extract the flow limiting cartridge from the remaining connector, via the metal bar. 5.2.5. Insert new flow limiter (supplied) into connector with metal bar facing upward. 5.2.6. Reconnect the push-fit connector. 5.2.7. Reconnect power and water supplies. Page 4 of 6

6.0 HIGH LIMIT RESET BUTTON 6.1. In the event of the element overheating, a Safety Cut-Out Switch (High Limit Reset Button) switches off the electrical supply to the water heater. Use the following instructions to locate the Reset Button. 6.2. Serial numbers up to HW415 have a 10 litre water heater 6.2.1. To access the High Limit Reset Button, unscrew the grey access cover plate. 6.2.2. The cut-out is identified by a red button and is located in the centre of the top of the immersion heater. 6.2.3. To reset the heater, press down the red button. 6.3. Serial number HW416 and over have a 5 litre water heater 6.3.1. To access the High Limit Reset Button, gently prise off the front of the plastic housing (this is clipped in place at the top, bottom and both sides). 6.3.2. The cut-out is identified by a black button and is located in the centre on the front of the immersion heater. 6.3.3. To reset the heater, press down the black button. 6.4. Contact Arrow Valves for advice. 10 Litre Heater 5 Litre Heater 7.0 FAULT FINDING 7.1. See fault finding chart available to download from the BTHW Ablution page of the Arrow Valves website - https://www.arrowvalves.co.uk/media/wysiwyg/pdfs/am162b-bthw-fault-finding- CHART.pdf 8.0 SEIZED PUMP 8.1. If the pump has not been used for several weeks, it is likely to be seized. Use the following instructions to free the pump. 8.2. Serial numbers up to HW190 have a Grundfos Watermill pump 8.2.1. Isolate power! 8.2.2. Using a screwdriver, rotate the fan in the rear of the pump until free. 8.2.3. Restore power. 8.3. Serial number MD590 and over have a Stuart Turner pump 8.3.1. Isolate power! 8.3.2. Unscrew the four screws securing the metal plate to the right hand side of the pump. 8.3.3. Prise off the metal plate with a screwdriver to reveal the fan. 8.3.4. Manually rotate the fan until free. 8.3.5. Reassemble the pump. 8.3.6. Restore power. 8.4. Contact Arrow Valves for advice. Page 5 of 6

Grundfos Watermill Pump Stuart Turner Pump 9.0 FILLING SOLENOID 9.1. Under normal operation the Solenoid is closed open when energised, closed when deenergised. 9.2. If the BTHW s tank is constantly overflowing, with the power isolated, this is likely to be caused by dirt/debris trapped in the diaphragm of the Solenoid Valve. 9.3. Please use the following link to a service video for instructions on how to inspect and clean the Solenoid Valve - https://www.youtube.com/watch?v=qf-1imnbkc0&t=13s 10.0 OPTIONS Option Wall Mounting Bracket for Midi range Ablution Hose & Trigger Chrome Ablution FC5 Cold Water Outlet Option Automatic Tank Purge System 24h Remote TMV Option BTMD/BTHW Alarm BMS Volt Free Pressure Reducing Valve Drip Tray for Midi range Stainless Code MIDIBRA CSHT-2 BTHW-OP1 BTHW-OP2 BTHW-1RTMV BTBMS3 BTHW-PRV BTDT3 Wall Mounting Bracket Stainless steel wall bracket for the BTHW-1 unit. Ablution Hose & Trigger Chrome - Ablution hose and trigger supplied. Ablution FC5 Cold Water Outlet Option - An additional outlet that provides cold water only. Automatic Tank Purge System /24h - Purges the tank every day for legionella control. Remote TMV Option - Thermostatic Mixing Valve is supplied remote from the unit. BTHW Alarm BMS - Volt Free BMS fault monitor with changeover. Activates fault lamp and BMS relay if tank water level is too high or low, or if there is a low pressure fault. Pressure Reducing Valve (PRV) Factory fitted to the pump outlet to give a constant outlet pressure. Drip Tray Catches any water discharged through weir if inlet valve is faulty and overflow blocked. Page 6 of 6