IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

Similar documents
enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

PCB Relays Single Relays

CII FCAC-150 Series Relay

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Class 1 laser beam sensor safe for your eyes

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

AUR300C. Advanced Ultraviolet Burner Controller

Class 1 laser beam sensor safe for your eyes

Digital Heater Element Burnout Detector K8AC-H

Class 1 laser beam sensor safe for your eyes

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018

02/11/2015

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

Operating Manual TR600

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018

VAMP 120 & 121. Arc flash detection units. Product picture

02/11/2015

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

Rules for Intruder Alarm Systems

E3M-V. Mark Sensor. Applications

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

PROTECT SRB 200EXi-1A

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Laser Collimated Beam Sensor

Ceiling Mount Temperature Sensor

Ultrasonic Reflective Sensor

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

onlinecomponents.com

Analog Room Pressure Monitor RPC Series

Latest update: Ordinance of the Ministry of Internal Affairs and Communications No. 25 of March 27, 2013

SHIMADEN DIGITAL INDICATORS

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Operating Manual MS220DA

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Pressure Switches Precautions 1 Be sure to read this before handling.

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03


Part 3 Troubleshooting

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Model Number Structure

Liquid Level Controller

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

Indoor Oxygen Monitor OX-600 Operating Manual

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

ARM SERIES Switching Relays With Priority

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

03.03.mmm REV.2 09/01

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

KILOVAC K1K High-Voltage Contactor

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

SCHMIDT LED Measured Value Display MD Instructions for Use

EMI Filter (Data Line) TRIGON COMPONENTS. Dimensions Table (mm)

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

CONTROL YOUR HOME FROM EVERYWHERE

NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Series Temperature Controller Instruction Sheet

TEMPERATURE CONTROLLER

E Specifications. Ver.1.2. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Ultrasonic Reflective Sensor

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Operating Manual MS220KA and MSR220KA

M7100 Pressure Transducer

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

BC-R10 Series. Burner Controllers

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Solid-State Contactor Specifications

Ultrasonic Proximity Sensor

U5700 Submersible Liquid Level Pressure Transducer

Table of Contents. Protective Relays

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Transcription:

To Be Discontinued IEC62055-31 UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays DZ RELAYS (ADZ) New New Horizontal terminal type FEATURES 1. IEC62055-31 UC3 compliant (short current 3,000 A) 2. High switching capacity 120 A 250 VAC (Resistive load) 3. Twin contacts for low temperature rise 4. Low operating power 1 coil latching: 1.4 W 2 coil latching: 2.8 W 5. Small size: W: 41 x L: 35 x H: 22 mm W: 1.614 x L: 1.378 x H:.866 inch TYPICAL APPLICATIONS 1. Smart meters 2. Charge station 3. Other industrial equipment Vertical terminal type RoHS compliant Protective construction: Dust cover type ORDERING INFORMATION Operating function 1: 1 coil latching 2: 2 coil latching Contact capacity 2: 120 A Contact material 1: AgSnO2 type (DC) 05: 5 V, 12: 12 V, 24: 24 V Terminal shape H: Horizontal type V: Vertical type ADZ 2 1 TYPES Contact arrangement 1 Form A Standard packing: Carton: 20 pcs.; Case: 100 pcs. Part No. Horizontal terminal type Vertical terminal type Horizontal terminal type Vertical terminal type 5 V DC ADZ12105H ADZ12105V ADZ22105H ADZ22105V 12 V DC ADZ12112H ADZ12112V ADZ22112H ADZ22112V 24 V DC ADZ12124H ADZ12124V ADZ22124H ADZ22124V 1 ASCTB338E 201703-T

DZ (ADZ) To Be Discontinued RATING 1. Coil data 1) 1 coil latching 2) 2 coil latching Set *Pulse drive (JIS C 5442-1996) Reset current [±10%] Coil resistance [±10%] 5 V DC *70%V or less of *70%V or less of 280.0 ma 17.9 Ω 12 V DC 116.7 ma 102.9 Ω 24 V DC 58.3 ma 411.4 Ω Set Reset current [±10%] Coil resistance [±10%] 5 V DC *70%V or less of *70%V or less of 560.0 ma 8.9 Ω 12 V DC 24 V DC 233.3 ma 116.7 ma 51.4 Ω 205.7 Ω power 1,400 mw power 2,800 mw Max. applied 130%V of Max. applied 130%V of 2. Specifications Characteristics Item Specifications Arrangement 1 Form A Contact Contact drop Max. 0.12V (at 120A), Max. 0.10V (at 20A) Contact material AgSnO2 type Nominal switching capacity (resistive load) 120 A 250 V AC Max. switching power (resistive load) 30,000 VA Rating Max. switching 276 V AC Max. switching current 120 A AC power 1,400 mw (1 coil latching) 2,800 mw (2 coil latching) Min. switching capacity (Reference value)* 1 100 ma 24 V DC Insulation resistance Min. 1,000 MΩ (at 500 V DC) Measurement at same location as Breakdown section. Breakdown Between open contacts 2,000 Vrms for 1min. (Detection current: 10 ma) Between contact and coil 4,000 Vrms for 1min. (Detection current: 10 ma) Electrical characteristics Overcurrent resistance Min. 3,000 A (Half-wave pulse of sine wave: 10 ms)* 4 Surge breakdown * 2 (Between contact and coil) 12,000 V Set time Max. 20 ms (Nominal applied to the coil, excluding contact bounce time) Reset time Max. 20 ms (Nominal applied to the coil, excluding contact bounce time) Functional 300 m/s 2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 μs) Shock resistance Mechanical Destructive 1,000 m/s 2 (Half-wave pulse of sine wave: 6 ms) characteristics Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10 μs) Vibration resistance Destructive 10 to 55 Hz at double amplitude of mm Mechanical Min. 10 5 (at 180 times/min.) Resistive load 120 A 250 V AC Min. 10 Expected life* 3 (operating frequency: ON : OFF = 10 s : 20 s) Electrical 100 A 276 V AC Min. 10 UC3 class (cosφ = 1.0 : 5,000, cosφ = 0.5 : 5,000, operating frequency: ON : OFF = 10 s : 20 s)* 5 Ambient temperature: 40 C to 85 C 40 F to 185 F Conditions Conditions for operation, transport and storage* 3 Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Unit weight Approx. 75 g 2.65 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock of ±1.2 50 μs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, operation, transport and storage conditions in NOTES. *4. IEC62055-31 UC3 compliant *5. Based on IEC62055-31 UC3, inductive load test was conducted after resistive load test, and expressed as total. 2 ASCTB338E 201703-T

To Be Discontinued DZ (ADZ) DIMENSIONS (mm inch) 1. Horizontal terminal type CAD Data 2±0.5.866±.020 The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 14.2±0.5.559±.020 External dimensions 3.2 dia..126 dia. 41.0±0.5 1.614±.020 35.0±0.5 1.378±.020 9.6.378 3.0.118 5.0.197 2.5.098 2 coil latching only Schematic (Top view) Set Coil Reset Coil 17.0±0.4.669±.016 4.7±0.4.185±.016 7.0.276 1±0.4.472±.016 11.7±0.5.461±.020 21.4±0.5.843±.020 2-4.3 dia. 2-.169 dia. 7.4±0.4.291±.016 1±0.4.472±.016 3-0.64 3-.025 8.1±0.5.319±.020 General tolerance: ±0.3 ±.012 2. Vertical terminal type CAD Data 2±0.5.866±.020 14.2±0.5.559±.020 External dimensions 3.2 dia..126 dia. 41.0±0.5 1.614±.020 35.0±0.5 1.378±.020 9.6.378 3.0.118 2.5.098 5.0.197 2 coil latching only Schematic (Top view) Set Coil Reset Coil 1±0.4.472±.016 17.0±0.4.669±.016 1.2.047 4.5.177 2-4.3 dia. 2-.169 dia. ±0.5 ±.020 4.7±0.4.185±.016 7.4±0.4.291±.016 3-0.64 3-.025 8.1±0.5.319±.020 General tolerance: ±0.3 ±.012 SAFETY STANDARDS VDE (Certified) File No. Contact rating 40038931 120A 250V AC (cosφ=1.0) 3 ASCTB338E 201703-T

DZ (ADZ) To Be Discontinued NOTES 1. For cautions for use, please read GENERAL APPLICATION GUIDELINES on page B-1. 2. Operation, transport and storage Following is the conditions of ambient temperature, humidity and air pressure in case of operation, transport and storage. 1) Ambient temperature: 40 to 85 C 40 to 185 F (Max.100A over 70 C 158 F) 2) Humidity: 5 to 85%RH (Not freezing and condensing) In addition the humidity range depends on temperature. The allowable ranges are as follows; 3) Air pressure: 86 to 106kPa Allowable range of ambient temperature and humidity for operation, transport and storage. 85 Allowable range 5 Humidity, %RH (Not freezing (Not below condensing 0 C 32 F) above 0 C 32 F) 40 0 40 32 Ambient temperature, C F 85 185 4) Condensing Condensing occurs when the relay is exposed to sudden temperature change in a high-temperature, high-humidity atmosphere. This may cause some troubles like insulation failure. 5) Freezing At temperature below 0 C 32 F, moisture may freeze. This may lead to some troubles like sticking of the moving portion of the relay or delayed operation. 6) Low-temperature, low-humidity atmosphere If the relay is exposed to a lowtemperature, low-humidity atmosphere for a long time, its plastic parts may become brittle and fragile. 3. Soldering and cleaning 1) In case of soldering, following conditions should be observed. Manual soldering: Max. 260 C 500 F (solder temperature) within 10s (soldering time) Max. 350 C 662 F (solder temperature) within 3s (soldering time) * Furthermore, because the type of PC board used and other factors may influence the relays, test that the relays function properly on the actual PC board on which they are mounted. 2) Since this is not a sealed type relay, do not clean it as is. Also, be careful not to allow flux to overflow above the PC board or enter the inside of the relay. 4. Terminal installation condition Installation torque for contact terminal (M4): 1.2 to 1.4 N m 5. Cautions for use 1) This relay is designed to dust cover type. Malfunction and contact failure may result if small insects get inside the relay. 2) Installation of M4 securing screw for contact terminal Do not apply excessive pressure on the terminals. This could adversely affect relay performance. Use a washer in order to prevent deformation. Keep the installation torque to within 1.2 to 1.4 N m (12 to 14 kgf cm). Also, use a spring washer to prevent it from loosening. 3) Through hole on the relay is for temporary fixing use. Do not fix relay through hole only. 4 ASCTB338E 201703-T