TL\l DRAIN TRAP. , s. JA JAHR Series I GS. TATSU2 SS1VA/JAHRASeries. Pamphlet A

Similar documents
Pamphlet M JA3D / JA Series / G8 AIR & DRAIN TRAPS. TATSU2 SS1VG / JAHSeries

Pamphlet M AIR & DRAIN TRAPS. JA JAHR Series / G8 TATSU2 SS1VG / JAHRG Series

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

- Pamphlet A2404 TLV. ertrap a ic I Pump & Pump/Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

STAINLESS STEEL PRODUCT GUIDE. Pamphlet M8012

Pure Performance For Steam Mains and Tracers

Pamphlet A2000. TL\l. Free Float Steam Trap Series

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Our Know-How. Your Peace of Mind. Steam Solutions

Pure Performance For Steam Mains and Tracers

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Liquid Drainers LIQUID DRAINERS

Pamphlet M2012 BALANCED PRESSURE THERMOSTATIC STEAM TRAPS

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

STEAM TRAPS

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Steam Condensing Heat Exchanger SR-3 / SR-8

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Oil burners fuel unit with solenoid valve

Refrigerant Valves/Accessories

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Series 1140 and 1141 Temperature Regulators

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

THE THERMOSTATIC STEAM TRAP

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

UNIVERSAL STYLE STEAM TRAPS WU450 Series

AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER. Series : V050, V100, V200, V250, V300

THERMOSTATIC STEAM TRAPS

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

Heat Transfer Equipment

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Module 7: Air Supply System

Oil burners fuel unit with solenoid valve

THERMODYNAMIC STEAM TRAP

YALE Site Specifications AIR VENT SCHEDULE

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action.

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

Marine Heat Exchangers SALES SERVICE REPAIR

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

KRAL Screw Pumps. L Series.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

The right trap for the right application.

13-1. Temperature Regulator

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

INSTRUCTION MANUAL UFO3-BN UFO3F-BN UFO3-CN FREE BALL-BUCKET STEAM TRAP UFO SERIES. Copyright (C) 2007 by TLV Co., Ltd. All rights reserved.

Pump & Trap Combinations

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

ESCO. Committed. Group of Companies. to help conserve Steam Energy

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

Hoffman Specialty General Catalog

Disc Type Steam Trap TSD-42

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

Untreated Compressed Air is Destructive. Protect Your Equipment and Save Money

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS JH-B SERIES JH5RL-B JH5RH-B JH7RH-B JH7.

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

Silhouette. Feedwater Heater. Boiler Feedwater

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

TECHNICAL DATA. Wet 26a. February 22, 2009

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL

Honeywell Control Valve. HFP Asia Pacific

Model DE-3 Air Release Head

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

The Safest Connections...

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

BERMAD Fire Protection

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Installation S

CD-33/CD-33S Controlled Disc Steam Traps

MFP14 Automatic pumps for condensate and other industrial fluids

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

Refrigerated Air Dryer

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

INSTALLATION, OPERATION

Refrigerated Air Dryer

Packaged Steam Fired Water Heater

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

MFP14 Automatic pumps. for condensate and other industrial fluids

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

LIQUIDATOR UMT-TD Series Thermodynamic

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Climate Control System

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

Air. Pressure. Motion. nnnnnnnn

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Industrial Refrigeration. Brochure R/S CB 02/10

Installation, Operation & Maintenance Instructions

Transcription:

TL\l - Pamphlet A3200-2 AR & JA JAHR Series GS, s DRAN TRAP TATSU2 SS1VA/JAHRASeries - -

TW. Free Float Technology n todays world of automation, compressed air is used in many different industries including high-precision machinery and instrumentation. After air is compressed it is cooled by an after-cooler or in a receiver tanl<, where condensate is formed from the air as water droplets. This condensate also occurs in compressed air distribution piping, leading to rust and fluctuation in highprecision machinery, as well as causing a reduction in product quality. Air traps protect your equipment and products by discharging condensate automatically. Long Service Life The hinge-less lever-less free float has one moving part allowing for simple operation. With infinite sealing surfaces, the free float does not suffer from concentrated wear; maintaining initial performance quality over a long time period. JA JAHR Series/GS Continuous Condensate Discharge The float adjusts quickly to changes in condensate flow adjusting the valve seat opening, ensuring continuous rapid discharge without condensate backup. JA JAHR Series/GS Rubber Valve Seat for Tight Sealing The standardized rubber valve seat allows for tight sealing with the precision ground float. JA Series* /GS * JA7.2, JA7.5, JAB and JAHR Series equip fluorine resin valve seat. Valve Seat Cleaning Mechanism Equipped with an external plunger unit, blockage caused by oils and/or scale can be easily eliminated. JA Series (JA3D/JA3/JAS/JA7J Discharge High-Viscosity Condensate With a large ( %") orifice, unique intermittent discharge and selfcleaning function, high-viscosity condensate as well as condensate containing dirt/scale can be discharged. Discharges large amounts of condensate (up to approx. 16,000 lbs/hour). TATSU2

for the Highest Reliability Lil<e compressed air, after air or other inert gases are compressed they are cooled, and condensate is formed from air or the gas as water droplets. Condensate is the cause of many challenges resulting in rust and freezing in the pipes as well as a reduction in product quality. Drain traps for discharging condensate from both compressed air and inert gases protect your equipment and products by discharging condensate automatically as it forms while maintaining a tight seal. These traps are made with durable steel construction for a long service life. * Do not use with toxic, flammable or otherwise hazardous gases. Long Service Life The hinge-less lever-less free float has one moving part allowing for simple operation. With infinite sealing surfaces, the free float does not suffer from concentrated wear; maintaining initial performance quality over a long time period. SS 1 VA Series/JAHRA Series Continuous Condensate Discharge The float adjusts quickly to changes in condensate flow adjusting the valve seat opening, ensuring continuous rapid discharge without condensate backup. SS 1 VA Series/JAHRA Series Three Point Seating for Tight Sealing The high-precision ground float fits securely on the threepoint seating creating a high-quality seal even for metal valve seats comparable to that of rubber. SS 1 VA Series/JAHRA Series Valve Seat Materials for High-Temperature/Pressure For higher temperature and pressure applications, TLV Drain Traps offer choices in body and valve seat material to meet specific needs. The SS VA has all-stainless steel construction with a metal valve seat available for high-temperature applications. The JAHRA Series features cast steel bodies for high-pressure applications with tight-sealing provided by a rubber valve seat. SS 1 VA Series/JAHRA Series 2

JA JAHR Series /GS Sample Application: Benefits: Air Main Drip Air Outlet -t Air nlet + Pressure-balancing j Line Condensate Outlet tn:=:l~::::jl!l~d + TLV JA3 Air Trap (with built-in screen) Free float type for continuous condensate discharge. Only one moving part, the free float, simplifies operation and provides reliable service. Usable for installation in both horizontal and vertical piping (JA3D). External valve seat cleaning mechanism easily eliminates blockage (JA3D/JA series). Large orifice to reduce valve seat blockage (JA7 /GB). Large capacity (Max. 57400 lb/h) and/or high pressure (PMO 600 psig). Applications: Discharge of condensate in air lines (end of piping after receiver tanks, after coolers, etc.). Small compressed air lines (JA3D/JA3). Lubricated air compressor systems where small amounts of oil get into the condensate (JA7 /GB). JAH8R Operation Pressure-balancing Line 1 2 3 As condensate enters the trap, the float rises controlling the size of the valve seat opening. With the valve open, the condensate is continuously discharged. f a large condensate load enters the trap at once, the float rises to open the valve seat fully, increasing the condensate discharge capacity. f no condensate enters the trap, the float is fully lowered to close the valve seat. The water level remains above the valve seat, promoting tight sealing. No. Part Name No. Part Name G) Body G) Body Cover Cover @ Float @ Float Valve Seat Valve Seat Screen Strainer Balancing Plug Balancing Plug 0 Plunger GS 3 Body Materiaf ZA DC DC DC Cl Cl Cl Cl Cl cs cs cs Valve Seat Materiaf21 NBR NBR NBR NBR NBR PTFE PTFE PTFE NBR PTFE PTFE PTFE Connection 3 1 s s s F F F F F s SW, F SW, F SW, F Max. Operating Pressure (psig) 230 230 230 230 230 230 230 230 230 600 600 600 Max. Operating Temperature ( F) 212 212 212 212 212 302 302 302 212 302 302 302 Min. Condensate Load for Tight Sealing (lb/h) 22 22 44 41, 33 22 22 44 41, 33 1 ZA: Zinc Alloy, DC: Ductile Cast ron, Cl: Cast ron, CS: Cast Steel 2 1 NBR: Nitrile Rubber, PTFE: Fluorine Resin 3 1 S = Screwed, F = Flanged, SW= Socket Weld 1 Orifice No. 2 & 5

TATSU2 Sample Application: Receiver Tank + Air nlet Receiver Tank Benefits: Large ( 51s" diameter) valve seat for easy discharge of oil, rust and scale. Large condensate discharge capacity (approx. 16,000 lbs/hour). Automatic self-cleaning function during operation keeps the valve seat free of any blockage. TATSU2 Applications: Air piping containing oil, rust or scale. Air-using receiver tanks or other equipment with higher viscosity condensate. Operation Pressure-balancing Line Condensate and oil flow into the trap and accumulate. When the level in the trap body rises to a point where the floats rise and lift the float holder @, the pilot valve opens with the help of the coil spring@. ~" " J.. _-... When pilot valve opens, secondary pressure air enters the pressure chamber @ lowering the piston and opening the main valve to discharge condensate. -,,-----.,., While the condensate inside the float cover discharges, the floats fall and cause the pilot valve to close. The pressure in the pressure chamber @ is released to the outlet and the piston rises to close the main valve after a slight delay to allow the main valve to self-clean during discharge. TATSU2 Note: Y Strainer with Slowdown Valve ncluded Body Material Connection Model TATSU2 Cast ron Screwed Max. Operating Pressure (psig) 150 Min. Operating Pressure (psig) 30 Max. Operating Temperature ( F) 176 No. Part Name CD Body Cover @ Float @ Float Cover @ Float Holder @ Piston <V Main Valve @ Main Valve Seat Pilot Valve > Pilot Valve Seat Balancing Plug @ Openina Sprina 4

SS1VA Sample Application: Receiver Tank Air/nert Gas Air/nert Gas nlet,.,::::::.:......::::::.., Outlet + + SS 1 VA does not use a pressure-balancing line, so make sure that the inlet piping to:::::------ is short to prevent ~-~- air-binding. Use a gate valve or fullbore ball valve on the inlet piping. \ \ TLV SS 1 VA Drain Trap with nternal Strainer Conden"!te Outlet ~ Benefits: High-precision ground free float with three-point seating technology for tight sealing even during low-load conditions. Only one moving part, the free float, simplifies operation and provides reliable service. All-stainless steel body with long life for vertical installation. Small models allow installation even with limited space. Applications*: Discharge of condensate from compressed air or inert gas-using equipment (compressors, etc.) Discharge of condensate in compressed air or inert gas lines (end of piping after receiver tanks, aftercoolers, etc.). Small capacity compressed air or inert gas lines. * Do not use for toxic. flammable or otherwise hazardous gases. SS1VA Operation 1 3-Point Seating Support 2 3 As condensate enters the trap, the float rises controlling the size of the valve seat opening. With the valve open, the condensate is continuously discharged. f a large condensate load enters the trap at once, the float rises to open the valve seat fully, increasing the condensate discharge capacity. f no condensate enters the trap, the float is fully lowered to close the valve seat. The water level remains above the valve seat, promoting tight sealing. SS1VA-R Part Name G) Body Cover @ Float Orifice (Valve Seat) Screen 5 Model SS1VA-R SS1VA-M Body Material Cast Stainless Steel Cast Stainless Steel Valve Seat Material Nitrile Rubber Metal Connection Screwed Screwed Max. Operating Pressure (psig) 150 300 Max. Operating Temperature ( F) 212 428 ANSl/FC Leakage Rating Equivalent Class 4 Class 6 Class 3 Class 3 (Minimum AP Required for Rating (psi)) (0. ) ( 1.5) (0. ) ( 1.5)

JAH RA Series Sample Application: Main Line with Separator TLV JAHSRA Drain Trap (with built-in screen) Benefits: High-precision ground free float with three-point seating technology for tight sealing even during low-load conditions. Only one moving part, the free float, simplifies operation and provides reliable service. Durable pressure-resistant design. Small model allows installation even with limited space (JAHSRA). Applications*: Discharge of condensate from compressed air or inert gas-using equipment (compressors, etc.) Discharge of condensate in compressed air or inert gas lines (end of piping after receiver tanks, aftercoolers, etc.). Large capacity compressed air or inert gas lines. * Do not use for toxic, flammable or otherwise hazardous gases. JAHSRA.,,.. Operation 1 2 3 As condensate enters the trap, the float rises controlling the size of the valve seat : opening. With the valve open, the condensate is continuously discharged. f a large condensate load enters the trap at once, the float rises to open the valve seat fully, increasing the condensate discharge capacity. f no condensate enters the trap, the float is fully lowered to close the valve seat. The water level remains above the valve seat, promoting tight sealing. JAHSRA No. Part Name G) Body Cover @ Float Orifice (Valve Seat) Screen Balancing Plug Body Material Valve Seat Material Connection Model Max. Operating Pressure (psig) Max. Operating Temperature ( F) ANSl/FC Leakage Rating Equivalent (Minimum AP Required for Rating (psi)) JAHSRA-R JAH7RA-R Cast Steel Nitrile Rubber Cast Steel Nitrile Rubber Screwed, Socket Weld, Flanged Screwed, Socket Weld, Flanged 315 600 212 212 Class 4 Class 6 Class 4 Class 6 (0. ) ( 1.5) (0. ) ( 1.5) 6

Pressure-balancing Line Without a pressure-balancing line connected between the trap cover and a dry portion of the piping/receiver tank, air or gas binding can occur. Air or gas binding occurs when vapor in the trap cavity cannot be displaced by the incoming condensate, which prevents condensate from being discharged. + Balancing Line! - TLV JA Series Air Trap For Air Flow: TLV DC3A Cyclone Separator (with nternal Trap) )) ~ Balancing Line Receiver Tank Compressor Note: Since the SS VA is installed vertically, a balancing line is not generally required. However, to prevent air binding, use as short as possible straight and vertical inlet piping with a minimum nominal diameter of/,. Selection Guide Max. ANSl/FC Max. Applicable Operating Min. Body Piping Valve Seat Oper. Leakage Discharge Special Fluids Model Connection Press. Range Specific Material Direction Material Temp. Rating Capacity Feature (psig) (of) Gravity Equivalent (lb/h) 2 1 JA3D Zinc Alloy Horiz.Nert. 505 JA3 Screwed 605 Plunger for Ductile JAS manual Cast ron Horizontal 990 Nitrile valve JAFS 212 - Flanged Rubber cleaning JA7 3540 Vacuum - 230 Simple GB Screwed Vertical 2950 direct Cast ron passages JA7.2 ~- 20980 Air ~ :E 22 1.0 JA7.5 ".0 41400 ncreased <U ==- capacity 0 01 JAB _J c 44 3 1, 33 57400 Flanged Horizontal PTFE 302 -rj"= JAH7.2R c ill 20980 ncreased 0 Vl 22 capacity u~ JAH7.SR Cast Steel Vacuum - 600..c 41400 and high c 01 pressure JAHBR ~ i= 44 3 1, 33 57400 service Discharges TATSU2 Screwed Cast ron Vertical Nitrile High- 30-150 176-16280 Rubber Viscosity Condensate Cast Nitrile All SSVA-R Vacuum - 150 212 Class 4 (6) 285 Screwed Stainless Vertical Rubber parts are Air and stainless Steel nert SSVA-M Metal Vacuum - 300 428 Class 3 (3) 845 0.50 steel Gases JAHSRA-R Screwed, Nitrile Vacuum-315 Class 4 (6) 595 High Socket Weld, Cast Steel Horizontal Rubber 212 pressure JAH7RA-R Flanqed Vacuum - 600 Class 4 (6) 3035 service 1-1 Rating is equivalent for d1fferent1al pressures of 0. 1 psi ( 1.5 psi) and higher 2 1 Maximum operating pressure. maximum differential pressure and condensate discharge capacity are affected by the specific gravity of the condensate. 3 1 Orifice No. 2 & 5 4 1 Do not use with toxic. flammable or otherwise hazardous gases. Full product details (sizes. pressures. capaeities and materials) are included in the individual specification data sheets (SOS). 1 CAUTON 1 CAUTON To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. DO NOT DSASSEMBLE OR REMOVE THS PRODUCT WHLE T S UNDER PRESSURE. Allow internal pressure of this product to equal atmospheric pressure and its surface to cool to room temperature before disassembling or removing. Failure to do so could cause burns or other injury. READ NSTRUCTON MANUAL CAREFULLY. - TW CORPORATON Manufacturer SO 9001SO14001 13901 South Lakes Drive, Charlotte, NC 28273-6790 Phone: 704-597-9070 Fax: 704-583-1610 TL\X M-hw f E-mail: tlv@tlvengineering.com For Technical Service 1-800 "TLV TRAP" ca.1n1 Kakogawa, Japan (M) nternet- World Wide-web URL http;uwww.tlv.com Pam phlet A3200-2 Rev. 4/2016 Specifications subject to change without notice.