MODEL MARINE WIND TRACKER

Similar documents
METEOROLOGICAL INSTRUMENTS

MODEL WIND TRACKER

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS

Sintrol Snifter A2 EX. Manual. Version 1.2.3

CLEANROOM MONITOR CR3A Network - Installation Instructions

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Sintrol Snifter A1+ Manual. Version 1.2.2

Software Version 2.01 LEVEL MONITOR MODEL 220

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Oakton TEMP 9500 Advanced Multiparameter Controller

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

TEMPERATURE CONTROLLER (STANDARD MODEL)

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

/8 DIN Level Indicator

Mark 25 Ultrapure Water Conductivity Analyzer

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Carbon Monoxide Transmitter

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

Oakton TEMP 9000 Advanced Thermocouple Controller

Analog Room Pressure Monitor RPC Series

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

eed quality electronic design USER s MANUAL

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Snifter ATEX22 VERSION. User Manual. Distributor

Beacon 800 Gas Monitor Operator s Manual

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

I/A Series 716C 1/16 DIN Temperature Controller

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Global Water Instrumentation, Inc.

JDDT1 - Single Stage Digital Thermostat

UDC100 Universal Digital Controller Specifications

Snifter. User Manual. Distributor

EVERWATCH FACE VELOCITY MONITOR MODEL 8610

Installation Manual Tracker 221

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Two-Channel Gas Controller

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Universal controller for panel mounting Models CS6S, CS6H, CS6L

D1000 Arc-fault Protection System

User's Guide. CO 2 Monitor. Model CO200

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

MT-374B/364B Operation User s Guide. The Anti-Sweat Energy Saving Controller user s manual

HVAC Controls Laboratory. Model EVERWATCH Face Velocity Monitor. Operation and Service Manual. P/N , Revision E October 2002

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

4 & 8-POINT ANNUNCIATORS Instruction Manual

Pump-Up Controller MODEL 4062

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

APPLICATION DATA SHEET

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Duct and Rough Service Carbon Monoxide Sensor

Dry Bath Heating Systems

Process & TeMPerATUre UniversAl input DigiTAl MeTers

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

ER65 - Mini Rack Controller Electronic Refrigeration Line

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

PTE0705 Electric Fence Monitor

Oxygen Monitor Operating Manual

EXPERT TRI-STAR. Temperature controller. User s Manual

Arc Fault Protection System D1000

21-light Remote Annunciator. Owner s Manual

Pump-Down Controller MODEL 4052

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

OWNERS MANUAL. HF Oil Content Monitor (OCM)

Nuclear Associates

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

20 Light Remote Annunciator

Oxygen (O2) Single-Point Gas Detection System

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

CRITICAL ENVIRONMENT MONITOR ALNOR AIRGARD 350 CEM

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

MD12-2 Vehicle Loop Detector

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Gas cylinder scale Model GCS-1

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

OPERATION MANUAL MODEL LC2000 COPYRIGHT 2017 PNEUMERCATOR CO., INC EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY 11788

ESSEX ENGINEERING CORPORATION

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Instruction Manual WARNING

Series EDA Electronic Pressure Controller. Specifications - Installation and Operating Instructions

Controllers. Instruction Manual WARNING

Pioneer-R16 Gas Monitor Operator s Manual

Transcription:

MODEL 06206 MARINE WIND TRACKER NOVEMBER 2001 MANUAL PN 06206-90 R. M. YOUNG COMPANY 2801 AERO-PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, U. S. A. TEL: (231) 946-3980 FAX: (231) 946-4772

MODEL 06206 MARINE WIND TRACKER FRONT PANEL YOUNG WIND TRACKER INTRODUCTION The YOUNG Model 06206 Marine Wind Tracker is a compact wind speed and wind direction display. This model has features such as relative wind angle and NMEA compatibility that make it suitable for shipboard use. 1. Wind Speed Display 2. Wind Speed Units Indicator 3. Alarm Status Indicators 4. Maximum Wind Speed or Relative Wind Direction Display 5. Relative Wind Direction and Variability Display 6. Brightness (operate mode), ENTER (setup mode) 7. MAX RESET (operate mode), SELECT (setup mode) BACK PANEL FEATURES 3 digit wind speed display 3 digit maximum wind speed or wind direction display Multi-color wind direction display with variability display Wind speed and direction alarms with delay RS-485/NMEA serial connections Calibrated 0-5 VDC outputs Display brightness control 4-20 ma Sensor Inputs Luminous front panel markings PRECAUTIONS INDOOR USE ONLY unless placed in approved enclosure. Operating temperature range 0-50 C (32-122 F), 0-95% RH. Use only recommended power sources; 12-30VDC, 4.5 W. Disconnect power when making connections or servicing sensors. MAXIMUM 24 VAC/30 VDC on alarm relay contacts. 1. Power input (12-30 VDC) AC adapter supplied 2. Sensor or 4-20 ma inputs 3. Earth ground connection 4. RS-485/NMEA serial connections 5. 0-5 VDC calibrated outputs 6. Alarm relay connections (normally open) 7. Input selector switch Page 1

MOUNTING AND START-UP 1. Select location for display. A location out of direct sunlight provides best visibility. The Wind Tracker may be mounted from a bulkhead or installed in a flush panel by removing the mounting bracket. Panel cutout dimensions are given in the specifications. An optional rack mounting panel (Model 06280) and protective enclosure (Model 06260) are available from your YOUNG supplier. 2. Connect cables to terminals. Refer to diagrams on page 5. Selector switch (item 7 on back panel illustration) should be DOWN for normal sensor inputs, UP for 4-20 ma or Wind Monitor-SE signals. 3. Connect GND terminal to suitable earth ground. 4. Insert power supply plug into power jack, plug into standard AC wall outlet. The Wind Tracker may also be powered from ships batteries. A coaxial power plug (2.1mm) must be used. Center is positive. 5. The Wind Tracker will display a software version number for approximately 4 seconds. It then begins to display wind information. The following information is displayed: Wind Speed Wind Speed Units Maximum Wind Speed or Direction degrees Relative Wind Direction (single orange indicator) Direction Variability (green indicators) WS, WD Alarm Status Indicators (if selected) 6. Observe the unit for a few minutes to verify that it is operating properly. If you wish to change settings (ie: wind speed units). See the following section. CHANGING SETTINGS The Wind Tracker has a setup mode that allows you to easily change sensor type, wind speed units, alarm settings, and other functions. Press and hold ENTER and SELECT keys (about 5 seconds). The display will briefly flash SET UP, then begin the SETUP sequence. Change settings with the SELECT key. Press the ENTER key to save a setting and move to the next step. Abbreviations in the left and right display windows identify each function and the available selections. DISPLAY SETUP FUNCTION LEFT RIGHT Input/Sensor Type InP LDi Line Driver 4-20 ma input 03 Wind Sentry 04 Wind Monitor-Jr 05 Wind Monitor, Wind Monitor-MA SEr Serial input from Wind Monitor-SE or main display If SEr is selected, wind speed units and NMEA output rate selections do not appear. NMEA Output Rate OUT FST 16 sentences sent per second SLO 1 sentence sent per second Display dsp SPd Displays MAXIMUM wind speed in right display. dir Displays WIND DIRECTION degrees (1 resolution) in right display. Wind Direction Alarm ALr no WD alarm not used. YES WD alarm activated. If no is selected, the following 2 steps do not appear. ALr dir Press SELECT to position alarm sector. Press ENTER. ALr SPn Press SELECT to set size (span) of alarm sector. Wind Speed Alarm ALr no WS alarm not used. YES WS alarm activated. If no is selected, the following step does not appear. ALr 000 WS alarm set point. Press SELECT to change digits. ENTER to save. If no alarm is selected, the following 2 steps do not appear. Alarm Delay Time dly 030 Set alarm delay time in seconds (0-999). Sound Snd no No sound with alarm. YES Audible beeper will sound with alarm. Test Functions tst no Skip test functions. YES For troubleshooting only. YES will initiate the following tests. If no is selected, the unit will return to normal operation. tst Snd Press SELECT to sound beeper. tst dsp Press SELECT to illuminate all display segments. tst ALr Press SELECT to close alarm relays. CAL 0.00 Press SELECT to alternate between 0.00 Vout and 5.00 Vout at terminals. Use to calibrate external devices (recorders, etc..) Wind Speed Units SPd unt Press SELECT to change units, ENTER to proceed. Page 2

ADDITIONAL INFORMATION ALARMS Wind speed and wind direction alarm functions are accessed in the SETUP sequence. Either or both alarms may be used. When activated, alarms are indicated on the front panel. When an alarm condition exists, the indicator will blink and the associated relay contact will close and the beeper will sound if selected in SETUP. When a delay time is set, the indicator will not report an alarm condition until it has existed for one complete delay period. Alarm activity will cease when conditions are outside the alarm range for one complete delay period. For a "latching" alarm effect, use the Wind Tracker alarm contacts to activate an external latching-type relay. BRIGHTNESS Adjust display brightness by holding the BRIGHT key. MAXIMUM / WIND DIRECTION DIGITAL DISPLAY The right display window can show either MAXIMUM WIND SPEED or Numerical WIND DIRECTION. This selection is made in the setup mode under Display (dsp). NMEA OUTPUT The Wind Tracker features NMEA serial output from the RS-485 terminals. These terminals can be used to operate remote displays or connect to other NMEA compatible devices. The NMEA output sentence is sent 16 times per second (Fast) or once per second (Slow) depending on the NMEA Output (OUT) setting in SETUP. For best remote display, use the Fast setting. REMOTE DISPLAYS The Wind Tracker can be used as a remote display by selecting "InP SEr" during SETUP. Remote displays are connected to the main display using the RS-485 terminals. NMEA Serial Protocol is used to operate remote displays. Up to 16 remote displays can be connected to one main display. Use the serial input when connecting to a Model 09101 Wind Monitor-SE sensor. See wiring diagram. VOLTAGE OUTPUTS The Wind Tracker offers calibrated voltage outputs for both wind speed and wind direction. This feature allows the use of recorders and other devices. Full scale voltage for each channel is 5.00 VDC. 4-20mA INPUTS The Wind Tracker accepts 4-20 ma (Line Driver) inputs. Line Driver circuit must provide 0-50 M/S Wind Speed scaling ("M" suffix). Connect cable as indicated on page 4. Slide switch on back must be UP at power up for correct 4-20 ma operation. Select LDI as input in SETUP. 24 VDC power is required for line driver applications. ERROR MESSAGES The Wind Tracker detects and indicates two errors. Once corrected, the error indication disappears. DISPLAY WARRANTY The Wind Tracker is warranted to be free of defects in materials and construction for a period of 12 months from date of purchase. Coverage is limited to repair or replacement of defective unit. SPECIFICATIONS Size: 144 mm (5.65 in) x 144 mm (5.65 in) x 36 mm (1.4 in) Panel Cutout: 138 mm (5.43 in) x 138 mm (5.43 in) Compatible Sensors: Wind Monitor-SE Wind Monitor Wind Monitor-MA Wind Monitor-JR Wind Sentry Other Inputs: 4-20 ma NMEA Serial Input/Output $WIMWV,ddd,R,sss,u,A[CR][LF] where: ddd wind direction in degrees Accuracy: sss u ±0.6% F.S. Display Resolution: Wind Direction: Wind Speed & Maximum: wind speed (ss.s for m/s) units (N = knots, K = kilometers/hour, M = meters/second, S = miles/hour) 10 circular pattern (36 points) 1 w/ dsp dir selected 1 Knot, 1 MPH, 1 KM/H, 0.1 M/S Voltage Outputs: Wind Direction Range: 0-5 VDC 0-360 Wind Speed Range: (dependent on units selected) 0-5 VDC 0-100 Knots 0-100 MPH 0-200 KM/H 0-50 M/S Alarm Relays: Non-latching Normally Open contacts for WS and WD. Contact rating 5A resistive, 2A inductive @ 24 VAC, 30 VDC. Input Power: 12-30 VDC, 4.5 W Weight: 1.0 lb (.45 kg) without AC adapter LDi Err 4-20 ma (line driver) signal. Signal is missing or outside of acceptable range. Verify proper switch position or signal. SEr Err Unit is set to receive RS-485 NMEA serial signal, but no serial data is coming in. Verify that NMEA source is operating. Check cables for proper connection. Page 3

CE COMPLIANCE This product has been tested and shown to comply with European CE requirements for the EMC Directive. Please note that shielded cable must be used. Declaration of Conformity Application of Council Directives: 89/336/EEC Standards to which Conformity is Declared: EN 50081-1 EN 55022 (CISPR 22 class A) EN 50082-1 (IEC 801-2, 3, 4) Manufacturer's Name and Address: R. M. Young Company Traverse City, MI, 49686, USA Importer's Name and Address: See Shipper or Invoice Type of Equipment: Meteorological Instruments Model Number / Year of Manufacture: 06206/1996 I, the undersigned, hereby declare that the equipment specified conforms to the above Directives and Standards. Date / Place: Traverse City, Michigan, USA February 19, 1996 David Poinsett R & D Manager, R. M. Young Company Page 4

Page 5

Page 6