Thermostats. Type Voltage Max. current Setting range Protection class HxWxD breakpoint [V] [A] [ C] [mm] RTEV C IP30 71x71x28

Similar documents
Fan heater Panther Powerful fan heater for large premises

Industrial infrared heater IR For premises with large volumes and high ceilings

Thermocassette HP RADIANT HEAT CASSETTES FOR CEILING MOUNTING

Original instructions. Panther 6-15 kw

SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see p Original instructions

Fan heater Panther WALL MOUNTED FAN HEATER

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

Original instructions. SIRe Basic Quick guide. SIReB

Fan heater SWT Ceiling mounted fan heater with water heat

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

Original instructions. Infrared heater IRCF...17

Mini Catalogue air curtains radiant heaters fan heaters convectors controls

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

Original instructions. Thermoplus PL RU

Elztrip EZ100 Single panel radiant heater for offices, shops etc.

Fan heater Panther 6-15 Efficient fan heater for medium size premises

Original instructions. Thermoplus

SIRe Advanced Air Curtains Water Ambient, no heat

S A U N A S S H O W E R S S T E A M B A T H S TYLO par Lavudson Sauna Page 1 sur 8

Original instructions AR

Thermozone AC 300/WAC 300

Original instructions SWX C/D NO DE ES... 26

Industrial infrared heater IR

Elztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Thermozone SF. Air curtains for vertical mounting in curved doorways

Radiant heaters - Offices, shops and public premises

SWS SE GB NO DE ES FR IT NL PL RU... 49

Thermozone ADR 200/300 E/W

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

INSTALLATION INSTRUCTIONS FOR USE CC 20

Inverter Ducted Air Conditioners

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Original instructions. SIRe Basic Fan Heaters Electric With quick guide. SIReBX. For wiring diagram, please see last pages.

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

SAT- 3 Installation Setup Guide

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

Original instructions. PF Smart... 60

EXT-CFU-230-D.. Touch Keypad Thermostat

Thermozone AD Corinte

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

Toll Free: Tel: Fax:

ETN-24-SUPER-PROG (US Program - Celsius)

ELECTRIC DESIGNER RADIATORS

Local Climate. Global Comfort. air curtains radiant heaters fan heaters convectors controls

Technical Information HXV - HRV Ventilation

Ceiling Concealed Series

YDS Variable Refrigerant Flow System. Digital Scroll Technology 3rd Generation

Data sheet Thermostatic sensors type RA 2000

Installation and user manual

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Touchpad controller User Manual installation operation

ETN-24-SUPER-SF Series

Mini catalogue air curtains radiant heaters fan heaters convectors thermostats. Comfortable and energy efficient indoor climate.

Comfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

Original instructions AGI4500/6000

5, SE GÅNGHESTER,

General information. Technical data...2 General information...2. Description. Installation

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PART NO. COMBUSTION AIR CAP

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

INSTALLATION & USER MANUAL

TEMPERATURE & PRESSURE CONTROLS

Sitron s CF Line of Flow Switch Monitors

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N


LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises

Thermozone RD. Air curtains for revolving doors

Heating Zone Control. How to apply RESOL MX controller

CONTENTS. Installation Guide. VT7200 Series

XE99 SERIES FAN-COIL THERMOSTATS 2-PIPE & 4-PIPE FAN-COIL CONTROL FEATURES APPLICATION PRODUCT SPECIFICATION SHEET

Operating Instructions Model : HC HC-N

ADVANCE ECB ELECTRIC COMBINATION BOILER

Inverter Ducted Air Conditioners

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

RA 2000 Series RA 15/6T & TB Conversion Valve

Semi flush-mount room thermostats

Daikin Altherma high temperature remote controller guide for schedule timers and operation functions

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

MODEL REO-1620SE ELECTRIC RETHERMALIZER OPERATING INSTRUCTIONS

ROOFTOP PACKAGED AIR CONDITIONERS

TABLE OF CONTENTS. Principle of operation of CAFM...1. Installation instructions...2. Main ADC Operating screen...3. Set process temp and Setback...

Electronic Room Thermostat

User & Installation instruction

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

4 in 1 Digital Thermostat Control

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

RA15/6T & TB Conversion Valve

Two-Position Electric Duplex Room Thermostats

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

IHC

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

PLXSID1605. Warning HEAD OFFICE :

MAKING MODERN LIVING POSSIBLE. Danfoss Air Catalogue. Catalogue DANFOSS HEATING

Transcription:

Thermostats RTE 0/0 RTEV 0/0/0V RTEV 0/0 RTEV 0 Electronic thermostats Setting of temperature on the RTE 0/0 is done on the circuit board under the housing to prevent unauthorised persons from changing the selected temperature. Thermostats are designed to control heat directly or to be used as sensors in larger centrally controlled facilities. RTEV 0/0 is equipped with a dial for setting the temperature. The setting range can be limited on the back of the dial and the thermostat can be calibrated there as well, if necessary. RTEV 0V is also equipped with an alternating relay and can therefore be used for the regulation of heating or cooling. External sensors mounted in ventilation ducts or the floor can also be connected. RTEV 0/0 has a function switch for on/off connection as well as the optional connection of external sensors. A fixed temperature reduction of ºC can be activated by an externally connected contact, such as a weekly timer. The setting range can be limited and calibrated on the setting dial. RTEV 0 also has a built-in clock function in addition to the dial and the option of connecting external duct or floor sensors. The period for temperature reduction by ºC is, 7,, or 6 hours. The preferred period is set on the circuit board upon installation. The reduction period is activated by pushing the start button at the desired time of day. The clock is then set and the reduction period starts at that time every day automatically. An ongoing temperature reduction period can be interrupted with a push of the start button. The following day, the reduction period once again begins at the usual set time. Type Voltage Max. current Setting range rotection class HxWxD breakpoint [V] [A] [ C] [mm] RTE0 0 +7 + C 7x7x8 RTE0 00 8 +7 + C 7x7x8 RTEV0 0 +7 + C 7x7x8 RTEV0 00 8 +7 + C 7x7x8 RTEV0V 0 +7 + C 7x7x8 RTEV0 0 +7 + C 7x7x8 RTEV0 00 8 +7 + C 7x7x8 RTEV0 0 +7 + C 7x7x8 8 Frico AB, Box 0, SE- artille Tel: +6-6 86 00 Fax: +6-6 8 60 mailbox@frico.se www.frico.se

KRT900/90 KRTV9 KRTE Capsulated Thermostats Capillary tube thermostats and electrical thermostats with alternating contacts Capillary tube thermostats with alternating contacts for the control of heaters and fans. The housing is of thermal plastic. Convertible between 0/00 V and approved for 6 A at 0 V and 0 A at 00 V. KRT 900/90 both have internal dials but have different setting ranges. KRTV 9 has an external dial with an adjustable stop for the imum setting. Electronic thermostats are not subject to mechanical wear. Thus, they are very reliable and have longer durability. A sensor on a metres long cable is included with the KRTE thermostat. The sensor can be placed anywhere or fixed directly on the thermostat. The cable is easily extendable. The KRTE has an alternating contact and is approved for 0A at 0V. Type Voltage Setting range rotection class HxWxD KRT900 0/00 0 +0 C I 6x7x60 KRT90 0/00 - +0 C I 6x7x60 KRTV9 0/00 0 +0 C I 6x7x60 KRTE 0-0 +0 C I 6x7x60 Frico AB, Box 0, SE- artille Tel: +6-6 86 00 Fax: +6-6 8 60 mailbox@frico.se www.frico.se 9

KRT800 000 -stage thermostats, capillary tube -stage regulation is appropriate for the soft and economical control of heating output in e.g. fan heaters and air curtains. There are two types to choose from: KRT 800 with an adjustable temperature difference between the stages ( - C). 000 with a fixed temperature difference ( C) between the stages. Both are convertible between 0/00V and approved for 6A at 0V and 0A at 00V. Type Voltage Setting range rotection class HxWxD KRT800 0/00 0 +0 C I 6x7x60 000 0/00 0 +0 C I x00x7 RTI -stage thermostat, electronic -stage thermostat with internal setting. Adjustable temperature difference between the stages ( 0 C). Type Voltage Setting range rotection class HxWxD RTI 0/00 + + C I 0x80x0 0 Frico AB, Box 0, SE- artille Tel: +6-6 86 00 Fax: +6-6 8 60 mailbox@frico.se www.frico.se

WIRIG DIAGRAMS THERMOSTATS Internal wiring diagrams RTE 0 0V~ L 00V~ L RTE 0 RTE(V)0 A RTE(V)0 8 A RTEV 0 RTEV 0 RTEV 0V 6 RTEV0V Cool 0V~ Heat A RTEV 0 RTEV0 0V~ A 6 h h 0V~ RTEV 0 7 h h RTEV0 A Ext. sensor RTEV 0 RTEV0 L 00V~ L 8 A Frico AB, Box 0, SE- artille Tel: +6-6 86 00 Fax: +6-6 8 60 mailbox@frico.se www.frico.se

WIRIG DIAGRAMS THERMOSTATS Internal wiring diagrams KRT(V) 9(00) 6A 0V~ /0A 00V~ KRTE 0A 0V~ /6A 00V~ <ϑ 0V~ KRT900 A B KRTE TC KRTV9 L L () L L ( ) KRT 800, 6A 0V~ /0A 00V~ 000 0A 0/ 00 V~ KRT800 - - 000 L L () L L () RTI 6A 0V~ /0A 00V~ <J <J 0V~ RTI L 6 7 L L ( ) Frico AB, Box 0, SE- artille Tel: +6-6 86 00 Fax: +6-6 8 60 mailbox@frico.se www.frico.se