New Fire Safety Order

Similar documents
Technical reference Reference & design

Handout Notes Major changes in BS : 2016

Emergency Lighting Design

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager

Guidance Note. Guidance Document for Testing and Maintaining Self-Contained Emergency Lighting and Luminaires

Emergency Lighting Guide. An authoritative guide to emergency lighting systems and design techniques

A Guide To BS Understanding the selection, spacing & siting of detectors

EMERGI-LITE An authoritative guide to emergency lighting & central power systems

EMERGENCY LIGHTING COMPLETION CERTIFICATE For small installations and verification of existing installations

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Fire Safety Register

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

EMERGENCY LIGHT SERIES

FIRE SAFETY LOG BOOK

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Fire Management Guide

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Emergency Evacuation Lighting Inspection & Maintenance

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

Fire Risk Management Policy. UK September 2017

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

Fire Risk Assessment Safety Checklist

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

The Social Accountability International (SAI) Fire Safety Checklist

Fire Safety Protocol

- CONSTRUCTION FIRE SAFETY STANDARDS

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Management Standard: Fire Safety

FIRE RISK ASSESSMENT

Date Issued: December 14, 2017 Revision: 2.1

Fire Safety Policy Date: 0

NOT PROTECTIVELY MARKED. Fire Legislation

- CONSTRUCTION FIRE SAFETY STANDARDS

Fire Safety Policy. Contents. This policy was approved by the Trustees on 6 September 2018 and will be reviewed not later than every 5 years.

FIRE RISK ASSESSMENT Self Assessment

ISO Clean Version of Revised Working Draft (N 348)

Fire Risk Assessment 2017

Health and Safety Services. Safety Guide 5. Fire drills

Fire Safety. A TUC guide for trade union activists

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

ISLE OF WIGHT FIRE & RESCUE SERVICE

PREMISES FIRE SAFETY LOGBOOK

If there are more than ten people working other than on the ground floor,

ISO INTERNATIONAL STANDARD. Safety identification Escape and evacuation plan signs. Identification de sécurité Plans d'évacuation et de secours

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years.

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

FIRE POLICY ST.GEORGES AND OUR LADY QUEEN OF PEACE PARISHES OF WORCESTER INTRODUCTION. Fire is one of the most common workplace hazards.

SELF PRESERVATION SOCIETY By Jim Creak

Dublin airport - Dublin, Ireland

INITIAL FIRE SAFETY ASSESSMENT

FIRE RISK ASSESSMENT

Policy for Safe Evacuation of Persons with Disabilities

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT

Fire Risk Assessment. ABC Car Workshop. Prepared for. Redacted

ISO INTERNATIONAL STANDARD

OPERATIONAL GUIDELINE. Office of the Fire Commissioner O.G.# Revision #1 TITLE: ISSUING ORDERS Page 1 of 8

5 Key Stages to Risk Assessment

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

NOTTINGHAM CITY HOMES

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

GI/GN7520. Guidance on Lighting of Railway Premises. Railway Group Guidance Note

LYHA Fire Safety Policy

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION

Joint Responsibility for Health and Safety Internal Guidance for Members and other occupiers of the Scottish Parliament Campus.

Charlotte Building, 17 Gresse Street, London W1T 1QL

Fire Safety Strategy

Design Guidelines Fire Safety in New and Refurbished Buildings

GDST Fire Safety Strategy March 2016

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

Fire Risk Assessment Mechanics Institute Manchester Road Burnley BB11 1JA

CHILD CARE CENTER INSPECTION CHECKLIST 06C

Fire Safety Policy SH HS 06. Version: 4. Summary:

Arbour House. Fire Policy and Procedures

FIRE SAFETY RISK ASSESSMENT AUDIT - CENTRE. Identification of hazards

Electrical Safety Policy and Management System

INITIAL FIRE SAFETY ASSESSMENT

FIRE RISK ASSESSMENT CHECKLIST

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

FIRE SAFETY POLICY Revised March 2013

Fire Risk Assessment 2016

Fire Risk Assessment Report

Emergency light. Safe solutions

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING

DEF Fire Evacuation and Emergency Planning Criteria

Transcription:

Voltimum Technical seminar New Fire Safety Order Implications for the Emergency Lighting Systems Presented by Chris Watts Cooper Lighting and Security Chairman of - British Standards CPL 34/9 Code of Practice (BS 5266) CPL 34/2/2 Emergency Luminaires (BS EN 60598-2-22) CEN CEN 169 Working group 3 (EN 1838 & pr EN 13032-3) CENELEC BTTF 62/8 Central Battery systems (EN 50171) Emergency Lighting Application (EN 50172) IEC Lumex ELP Luminaires & Auto. Test (IEC 60598-2-22 & 62034 ) IEC Wiring Reg. CEI 60364-5-5664-MT34 Wiring for safety services Trade Association ICEL Technical committee chairman Vice Chairman BFPSA training committee

Fire Safety Order - Implementation Oct 06 Main points- Fire certificates cease to have any effect. Responsibility for complying with the Fire Safety Order will rest with the 'responsible person'. In a workplace, this is normally the employer or any other person having control of the premises, e.g. the occupier or owner. The responsible person must carry out a fire risk assessment focusing on the safety of all people on the premises. The assessment must include an action plan to use appropriate fire precautions to compensate for the risks in the building.

Steps for a Risk Assessment The responsible person (normally the employer) MUST perform a risk assessment. 1 Identify fire hazard- sources of ignition- fuel- work processes 2 Identify the location of people at risk 3 Evaluate the risks Check existing fire safety measures are adequate Fire detection & means of escape, including emergency lighting Maintenance and testing of fire precautions- Carry out any improvements needed 4 Record findings and action taken Prepare emergency plan and train employees 5 Keep assessment under review and revise for changes.

Fire Safety Guides - E L Requirements Emergency Escape Lighting- In premises with internal escape routes or which are used during darkness including early darkness on winter days then emergency lighting is likely to be required. In larger more complex premises it is likely that automatic emergency escape lighting will be needed for all escape routes. Checklist -Are your premises used during periods of darkness? The installation of an emergency escape lighting system should be carried out by a competent person in accordance with BS 5266-1 and-8

No. 0-5 6-20 20 + Implications for emergency lighting Fire precautions act Fire Certificate No requirements No requirements except for sleeping risks above 6 people Fire certificate required From Fire Authority Fire Safety Order Risk Assessment Must comply but no written record needed Must comply, with a written record and reports from competent engineer. Self certification with audit by Fire authority.

Premises to old standards prior to 2005 Previous legislation was not retrospective so existing fire precautions and certificates may not be adequate. Risk assessment must consider the risks based on current recommendations and standards not those that applied when the building was constructed. Hotel built in 1970 no lights in open areas, unchecked levels in corridors Hotel built in 2007 0.5lux in open areas - 1 lux in corridors

Removal of fire certificates & the statutory bar Likely changes that may be needed to Emergency Lighting Systems Typical 1970 Premises Escape routes poorly engineered to 0.2 Lux Min Open Areas not covered or to 1 Lux Average Testing facilities not provided Luminaires & C. Systems not 3 rd party certified 2007 Premises Escape routes correctly engineered to 1 Lux Min Open Areas covered to 0.5 Lux Minimum Appropriate testing facilities provided Luminaires to BS EN 60598-2-22 C. Systems to EN 50171

Implications of the Legislation Many smaller premises will now have to install fire precautions Many older premises will now have to improve and upgrade their fire precautions. They will now need to be able to ensure that their testing is kept up to date. Systems need repair quickly after failure to limit the time temporary safety procedures are used. The responsible person needs to use trained competent persons to conduct their system design and installation. The guide directs people to the latest issue of BS 5266 for emergency lighting systems

Changes to BS 5266-1 in Dec 2005. The Code of Practice is an umbrella document for relevant emergency lighting standards The requirements for cinemas and similar establishment are now included replaces CP1007 Consultation - takes account of the risk assessment Exit signs - where occupants are unfamiliar with the building, maintained operation should be considered The requirements for toilets are clarified Luminaires are now referred to BS EN 60598-2-22 clarifying parts of the luminaire to be fire resistant. Format of completion and test certificates now updated

CP 1007 Application Changes CP 1007 BS 5266-1 2005 Mains healthy or mains failed - All emergency lights fully maintained Mains healthy- Whatever maintained lights are needed for safe operation Mains failed- Escape routes (i.e. the aisles) to EN 1838 Note This only applies to premises with seats fixed to the floor

Lighting Levels Escape routes Escape Routes, Verified values are given in ICEL Authenticated Photometric Data Spacing tables 1 Lux to wall 0.5+0.5 = 1 Lux Transverse spacing to wall Transverse spacing Between fittings

6.3.3 - BS 5266-1:2005 Illuminances and response times for open areas are given in BS EN 1838:1999/BS 5266-7:1999, 4.3. It requires 0.5 lux minimum anywhere in the central core of the floor area. This core area excludes the 0.5m to the perimeter of the area. The shadowing effects of movable objects in the core area are excluded. Wall of room Under table excluded Round fixed pillar included 0.5 meter border excluded from requirements Central core requiring 0.5 Lux minimum

6.6 - BS 5266-1:2005 The luminance of escape route signs is specified in BS EN 1838:1999/BS 5266-7:1999, Clause 5. The risk assessment should identify the premises where this is important to make the exit signs maintained to be conspicuous if evacuation is needed while the mains is healthy The product standards BS EN 60598-2-22 checks that the illumination levels are adequate Minimum luminance of any part of the signboard 2 cd/m2 The ratio of maximum to minimum luminance of any area of either colour of the sign shall not be greater than 10:1 The ratio of luminance between white and adjacent colour shall be between 5:1 & 10:1

6.6 Emergency Signs Viewing Distance as BS 5266 pt 7 / EN 1838 H (Height of panel) D (Distance from sign) Internally illuminated Maximum D less than 200 x H Externally illuminated Maximum D less than 100 x H Note the Guide also requires Photoluminescent signs to have Emergency Lights illuminating them

7.4 - BS 5266-1:2005 Provision of reliable emergency escape lighting is essential. The illumination by the emergency escape lighting system of a compartment of the escape route shall be from two or more luminaires so that the failure of one luminaire does not plunge the route into total darkness or make the directional finding effect of the system ineffective. For the same reason two or more luminaires shall be used in each open area This clarifies the previous edition of BS5266-1 6.3 which said that a consideration should be given to eliminating hazards from the failure of a single lamp

Toilets and changing facilities Emergency lights-needed If above 8 m 2 floor area (2 needed) If no windows (1 needed if less than 8m 2 ) Facilities for disabled(1 needed if less than 8m2 ) E. lights not needed If the facilities are smaller than 8 m 2 floor area and have natural daylight available Or if they are single facilities for the able bodied or are part of a hotel suite.

Standards upgrade to support risk assessments Experience of designing systems to protect hazards identified by risk assessments has identified that emergency lighting can fulfil a very useful function beyond the normal protections of escape routes. Protection of those particularly at risk from disabilities or from their location. To protect those who must conduct or complete actions in a supply failure To provide sufficient illumination to enable tasks related to safety activities to be conducted. BSI is developing a standard to give advice on values.

Kitchens Identify fire hazard- Sudden failure of lighting while staff are cooking hot food is potentially dangerous, currently these areas need an emergency light over the extinguisher but guidance should be given as to the light level, response and duration times of emergency lighting over the area for hot food preparation and evacuation routes

Treatment areas Identify people at risk Current value 5 lux on floor if not on escape route Currently the requirement is for the light level needed to evacuate the premises on escape routes we are now considering the light level, response and duration times of emergency lighting of first aid rooms Split between - First Aid points. - Treatment areas for minor Operations/ Dentistry.

Refuges Identify people at risk Refuge areas for disabled staff. In these areas fire wardens will now have to go and collect disabled persons often also transferring them into rescue sleds to enable them safely to be taken down stairs should consider the light level response and duration times of emergency lighting in refuges

Illumination of crash bars Where the exit doors have security devices that require manipulation such as crash bars then the bars should have appropriate downwards illumination Illumination for exit signs on doors that require operation of a manipulative security device should also provide sufficient illumination to facilitate the location and operation of the device

Facilities for checking the Panel It is part of the responsible persons duty to investigate the source of the alarm and investigate the cause Consequently the emergency lighting must be sufficient to read the panel and any associated building plans Light levels at both the panel and building plans must be adequate for them to be read correctly

Operation of Test Facilities Are the users staff trained and capable of operating and recording them correctly? Operators must be trained to Understand and keep to the test schedule intervals They must know the procedure to initiate and terminate the test then check recharge. They must be able to assess if the test is satisfactory and note any needs for maintenance such as blackening of tube ends or excess dirt on diffusers They must be able to initiate rectification in the event of failure of a test and introduce measures to protect occupants until repairs are made

Cooper products to assist compliance LED powered exit signs which have significantly better lamp life than fluorescent signs. Improved light outputs from Alfalux dedicated High power luminaire Conversion of high efficiency mains luminaires High output central systems High quality portable emergency luminaires Automatic Testing systems to assist responsible persons to demonstrate that test schedules have been met safely Products have full data to assist correct designs

Cooper Menvier Britesign Britesign uses two high power LED (Light Emitting Diodes) optimised to provide sign illumination to BS EN 1838/BS 5266-7 for a design life of continuous maintained operation of 4 years. The LED s are mounted at the base of the sign and also give threshold light on crash bars etc.

Cooper Alfalux High Bay The Alfalux self contained luminaire uses a large battery with a high output from the lamp which is then optimised to give the high light outputs needed to compensate for the risks now being identified by risk assessments. Alternatively conversions or central systems can be used

Cooper Menvier Portable Handlamp The use of hand lamps may be appropriate in very small premises but some have a tendency to get broken, discharged lost or stolen. This hand lamp is also particularly useful to assist managers and fire wardens to check if evacuation is complete This rechargeable hand lamp operates automatically in the event of supply failure, it is robustly constructed in accordance with BS EN 60598-2-22 and the draft specific requirements

Automatic Test Systems Automatic test systems are available either as self contained luminaires or as part of a system which collects the controls and indications of test results at a single position and can be used with either self contained or central battery systems

Where Further Data and Advice Voltimum Web Site can be obtained BSI for standards courses and publications ICEL Web Site and training courses CIBSE for design guides and courses Cooper Lighting and Security for detailed product and application guides or our exhibition stand Associated Technologies Fire Alarms FIA web site

Relevant Standards Open Area Lighting BS5266 Luminaire Pt 7:1999 (EN1838) Product Standard EN60598-2-22: 22: 1999 Escape Route Lighting Fire Points BS5266 Pt 7:1999 (EN 1838) Wiring HD384-5 Other Areas (eg Lifts) BS 5266-1 Signage Signs Directive HSE Guide Maintained or non-,main. Duration of Luminaires BS 5266-1 Central System Product Standard EN 50171 New BS5266-10 to cover risk assessment hazards