Saunier Duval Clima, S.A.

Similar documents
Saunier Duval Clima, S.A.

Saunier Duval Clima, S.A.

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Choosing the installation site. Installation. 07 Choosing the installation site

AIR CONDITIONER INSTALLATION MANUAL INSTALLATIONSANLEITUNG MANUEL D INSTALLATION MANUAL DE INSTALACIÓN MANUALE DI INSTALLAZIONE

INSTALLATION MANUAL AIR CONDITIONER OUTDOOR UNIT INSTALLATION MANUAL. INSTALLATIONSANLEITUNG Nur für autorisiertes Personal.

INVERTER SPLIT - TYPE

Split Air Conditioner

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

DAIKIN AIR CONDITIONER

[FLARE CONNECTION TYPE] ATTENTION

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO )

Notices for installation

Nortek Global HVAC, LLC

AIR CONDITIONER CONSOLE

SPLIT WALL-MOUNTED AIR CONDITIONER

Split-type Air-Conditioner

AIR CONDITIONER CASSETTE

Split-type Air-Conditioner

AIR CONDITIONER BRANCH BOX INSTALLATION MANUAL. For authorized service personnel only. [UTP-PY03A] [UTP-PY02A] PART NO.

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

CENTRAL AIR CONDITIONER SPLIT SYSTEM

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

SPLIT-TYPE ROOM AIR CONDITIONER

ROOM AIR CONDITIONER INSTALLATION MANUAL

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

1. BEFORE INSTALLATION

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

1. BEFORE INSTALLATION

AIR CONDITIONER FLOOR CEILING

INSTALLATION INSTRUCTION

AIR CONDITIONER OUTDOOR UNIT

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

GENERAL INFORMATION CONTENTS

AIR CONDITIONER OUTDOOR UNIT

1. BEFORE INSTALLATION

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

BEFORE USING THE APPLIANCE SAFETY PRECAUTIONS AIR CONDITIONER PRECAUTIONS

1. BEFORE INSTALLATION

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

ADL DYNAMIC STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE ADL 2012 ADL 3018 ADL 4024 ADL 5030

AIR CONDITIONER OUTDOOR UNIT

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

Split-type Air-Conditioner

DC Inverter U-match Series Duct Type Unit

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

INSTALLATION MANUAL ENGLISH FRANÇAIS AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-30, 32SK Series. Outdoor unit RAS-30, 32S Series

1. BEFORE INSTALLATION

INSTALLATION MANUAL For authorized service personnel only.

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

INSTALLATION MANUAL. AIR CONDITIONER Indoor Unit (Duct type) PART No Contents. En-1 1. SAFETY PRECAUTIONS WARNING

Installation Manual Forest Series All Model Numbers

Split Air Conditioner

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-05, 07, 10, 13, 16BKV-E. Outdoor unit RAS-05, 07, 10, 13, 16BAV-E

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION

AIR CONDITIONER (SPLIT TYPE) Installation manual. Outdoor Unit. English. Model name: For commercial use

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

Installation manual for room air conditioner

INVENTER SPLIT -TYPE ROOM AIR CONDITIONER

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Air Conditioner Service Manual KSWT SERIES INSTALLATION INSTRUCTION. Wall-mounted Split Type

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

AIR CONDITIONER OUTDOOR UNIT

AIR CONDITIONER CASSETTE

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

RAV-SM1104AT8P-E RAV-SM1104AT8JP-E RAV-SM1404AT8P-E RAV-SM1404AT8JP-E

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

FLOOR TYPE AIR CONDITIONERS

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION R410A INSTALLATION MANUAL

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Mini-Split Air Conditioner

Installation Instructions

AIR CONDITIONER (MULTI-SPLIT TYPE)

R410A SPLIT SERIES DC INVERTER

IOM & Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.

AIR CONDITIONER (SPLIT TYPE) Installation manual. Outdoor Unit

Reverse Cycle Inverter Split System Air Conditioner

SPLIT -TYPE ROOM AIR CONDITIONER

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.

Transcription:

Saunier Duval Clima, S.A. INSTALLATION MANUAL SDC/H 050 F SDC/H 065 F SDC/H 085 F SDC/H 105 F SDC/H 105T F SDC/H 120 M2F Safety Regulations...3 Indoor Unit Installation Dimensions... 4 Unit Location... 5-6 Outdoor Unit Installation Location... 7 Pipe Lenght... 7 Dimensions... 8 Installation Details... 8-9 Wiring Diagrams...10

1- SAFETY REGULATIONS The installation shall be made by authorised personal only Do not allow the customer to fit the air conditioning unit. Installation of the unit must be carried out by either the local distributor or a specialist fitter. The fitter is responsible for any problems caused by a faulty installation. The installation instructions must be followed closely. A faulty installation can lead to water leaks, electrical discharges or fires. Do not use any coolant other than R22. The mixture of gases in the cooling cycle can lead to damage or impaired performance. Check that the mounting and fastening devices are sufficient to withstand the weight of the unit. If they are not, the unit may fall and cause an accident. Ensure that all fastening devices and accessories are used. Use of any items not shown can lead to water leaks, electrical discharges or fires. Carry out electrical connections in accordance with local regulations and the instructions laid down in the installation manual. Ensure that the proper cables have been used. If they have not, this may cause electrical discharges or fires. While connecting the outdoor unit, keep the cabling conduit rigid. Faulty cable fitting can cause overheating, electrical discharges or fire at these connections. The system must always be earthed. If it is not, this may lead to electrical discharges. Do not fit units in places which may be affected by leaks of inflammable gas. If the gas is in circulation around the units, this may cause explosions. Place the drainage hose in a suitable position. An improperly fitted hose will force the water back to the room, thus damaging the furniture. This air conditioning system is for home use only. Do not use it for any unspecified applications: warehouses, foodstuff depots, animals, plants, precision machinery, works of art etc. These items may be damaged as a result. Use the voltage shown. If this is not used, it may cause a fire or other problems. IMPORTANT NOTES Saunier Duval, along the lines of its continuos product quality improvement policy, reserves the rights to modify the specifications without previous notice. Saunier Duval cannot foresee all circumstances that could result in hazard potentials. This A.C. unit is designed exclusively for air conditioning. Do not use this unit for any other purposes like drying clothes, cooling foodstuff or any other heating or cooling purposes. No part of this manual can be copied without written permission. Should you have any queries, please contact your nearest Saunier Duval distributor. This A.C. unit has been designed for the operating temperatures specified below. Do not let it work outside said ranges. This unit should be installed and used in compliance of the following: - Low Voltage Electrotechnical Regulations - Safety Regulations for Cooling Plants and Facilities - Pressure Vessel Regulations - Basic Building Standards - Technical Building Standards - Municipal Regulations EXTREME OPERATIONS CONDITIONS SUMMER - OUTDOOR 0ºC Min. 43ºC Max. - INDOOR 19ºC Min. 32ºC Max. WINTER - OUTDOOR -5ºC Min. 24ºC Max. - INDOOR 15ºC Min. 27ºC Max. 3

2- INDOOR UNIT INSTALLATION Decide the mounting position together with the customer as follows: 1. INDOOR UNIT - Install the unit where the drain pipe can be easily installed. - Take servicing, etc. into consideration and leave the spaces for the aftersale service. INDOOR UNIT DIMENSIONS MODELS A B C D E F Weight (kg) 050 FI 645 955 199 280 185 873 30 065 FI 645 955 199 280 185 873 30 090 FI 645 1.250 199 280 185 1.168 40 105 FI 645 1.600 245 300 80 1.470 63 Units in mm. 4

2- INDOOR UNIT INSTALLATION 2- INSTALLATION PROCEDURE 1- PREPARING INDOOR UNIT INSTALLATION Remove the intake grille and side cover(s) by removing the tapping screws. 2. INSTALLING DRAIN HOSE Insert the drain hose into the drain port, then secure the drain hose with a nylon fastener. 2- INDOOR UNIT INSTALLATION A. FLOOR INSTALLATION Wrap the insulation around the drain hose connection. 1. DRILLING FOR PIPING Select piping and drain direction. The piping and drain can be made in two directions. Be sure to arrange the drain hose so that it is levelled lower than the drain port of the indoor unit. - The drain hose can be connected to the drain port either left or right side. - Do not install the unit so that the drain hose side is too high. Height A should be less than 5. - When the direction are selected, drill 4 (100 mm) dia. hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow. When the pipe is led out from the rear, make a hole in Fig. 7 at the position shown. 5

2- INDOOR UNIT INSTALLATION B. CEILING INSTALLATION Using the distance between drilling holes as shown below, drill holes for piping and anchor bolts. Insert the anchor bolts into the drilled holes, and drive the pins completely into the anchor bolts with a hammer. 3. INSTALLING HANGERS Install the hangers with nuts and spring washers. 1. DRILLING FOR PIPING Select piping directions. 4. INSTALLING INDOOR UNIT Reset the bolts as shown below. - Install the drain hose at the rear, it should not be installed on the top. Apply the indoor unit to hangers. When the directions are installed, drill a 3 1/8 (80 mm) an 2 (50 mm) or 6 (150 mm) dia. hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow. Now, securely tighten the bolts in both sides. 5. INSTALL THE DRAIN HOSE Be sure to arrange the drain hose so that its level lower than the drain port of the indoor unit. 2. DRILLING HOLES FOR ANCHOR BOLTS AND INSTALLING THE ANCHOR BOLTS With a concrete drill, drill four 3/8 (9,5 mm) dia. holes. - Always check that the drain cap is installed to the unused drain port and is fastened with the nylon fastener. If the drain cap is not installed, or is not sufficiently fastened by the nylon fastener, water may drip during the cooling operation. 6

3- OUTDOOR UNIT INSTALLATION 1. OUTDOOR UNIT (1) If possible, do not install the unit where it will be exposed to direct sunlight. (2) Install de outdoor unit in a place where it will be free from being dirty or getting by rain as much as possible. (3) During heating operation, drain water fl ows from the outdoor unit. Therefore, install the outdoor unit in a place where the drain water fl ow will not be obstructed. (Heat pump model only). (4) Do not place animals and plants in the path of the warm air. (5) Take the air conditioner weight into account and select a place where noise and vibration are less. (6) Select a place so that the warm air and noise from the air conditioner do not disturb neighbours. (7) Provide the space so that the air flow is not blocked. Also for effi cient operation, leave open three or the four directions front, rear and both sides. (8) When the outdoor unit will be exposed to strong wind, fasten it with bolts at the places indicated by the arrows. (9) When installing the drain pipe, plug another hole () in the bottom of the outdoor unit with drain cap so there is no water leakage. Location for a correct air flow. PIPE LENGHT ORIGIN DISTANCE IN LINEALS m. Models R22 (kg) Lines( ) 15 m (4 curves) 20 m (6 curves) 30 m (8 curves) 50 m (6 curves) Max. Height (m) Cool Heat Gas Líq. % Aprox. R22 Oil % Aprox. R22 Oil % Aprox. R22 Oil % Aprox. R22 Oil Over Under (g) (g) (g) (g) (g) (g) (g) (g) IU IU 050 CO 1.500 1.500 5/8 3/8 99 250 --- 98 400 --- 96% 800 20 92 1.500 50 45 20 050 HO --- --- --- --- --- --- --- --- --- --- --- --- --- --- 070 CO 1.850 1.850 5/8 3/8 98 250 --- 96 400 --- 92 800 --- 87 1.500 50 45 20 070 HO 3/4 3/8 100 300 --- 99 500 --- 97 800 20 94 1.500 50 085 CO 1.700 2.000 3/4 3/8 98 300 --- 97 500 --- 94 800 20 89 1.500 50 45 20 085 HO 7/8 3/8 102 300 --- 101 500 --- 99 900 20 96 1.600 50 105 CO 2.800 3.200 3/4 3/8 97 300 --- 95 500 --- 92 800 20 85 1.500 50 45 20 105 HO 7/8 3/8 101 300 --- 100 500 --- 98 900 20 94 1.600 50 105T CO 2.800 3.200 3/4 3/8 97 300 --- 95 500 --- 91 800 20 85 1.500 50 45 20 105T HO 7/8 3/8 101 300 --- 100 500 --- 98 900 20 94 1.600 50 Optional 7

3- OUTDOOR UNIT INSTALLATION 2- OUTDOOR UNIT INSTALLATION - Set the unit on a strong stand, install protective rubber pieces under it. - Do not install the unit directly on the ground, because it will cause trouble. - Install the unit where it will not be tilted by more than 5º. Dimensiones de las Unidades Exteriores 3. CHECKING THE PIPE CONNECTIONS FOR GAS LEAKING - For both the indoor and outdoor unit sides, check the joints for gas leaking by the use of a gas leakage detector without fail when the pipes are connected. 4. HEAT INSULATION ON THE PIPE JOINTS - Put coupler heat insulator on the joints. AIR PURGE - Close the high pressure side valve fully. - Check if the piping connections are secure. - Check that the stems of both 3- way valves are closed fully. - Connect the gauge manifold service hose to the charging port of the 3- way valve (side with the projection of pushing in the valve core). - Open the low pressure side valve of the gauge manifold fully. - Operate the vacuum pump and start pump down. - Pump down the system for at least 15 minutes, then check if the compound pressure gauge reads - 100kPa (- 76 cm Hg, -1bar) Units in mm. - At the end of pump down, close the low pressure side gauge of the gauge manifold fully and stop the vacuum pump. - Slowly loosen the valve stem of the 3- way valve. When the compound pressure gauge reading reaches 1-2 kg/ cm2, retighten the valve stem and disconnect the service hose from the 3- way valve charging port. (If the stem of the 3- way valve is opened fully before the service hose is disconnected, it may be difficult to disconnect the service hose.) 8

3- OUTDOOR UNIT INSTALLATION - Fully open the valve stems of both 3- way valves using a hexagon wrench. (After the valve stem begins to turn, turn it with a torque of less than 2.9 N- m (30 kgf- cm) until its stop turning.) - Firmly tighten both 3- way valves blank cap and the charging port cap. (3) The circuit breaker is installed in the permanent wiring. Always use circuit that can trip all the poles of the wiring and has an isolation distance of at least 3 mm. between the contacts of each pole. (4) Perform wiring work in accordance with standards so that the room air conditioner can be operated safely and positively. 7- ELECTRICAL WIRING (1) Connect the connection cords fi rmly to the terminal block. Imperfect installation may cause a fi re. (2) If the indoor unit connection cord (to the outdoor unit) and power supply are wired incorrectly, the air conditioner may be damaged. (3) Always connect the ground wire. ADDITIONAL CHARGE - Refrigerant suitable for a piping length of 10 m. Is charged in the indoor unit at the factory. - When the piping is longer than 10 m., additional charging is necessary. WARNING! (1) When moving and installing the air conditioner, do not mix gas other than the specifi ed refrigerant (R-22) inside the refrigerant cycle. (2) When adding refrigerant, add the refrigerant from the charging port at the completion of work. 5- GAS LEAKAGE INSPECTION WARNING!- After connecting the piping, check the joints for gas leakage with gas leak detector. 6- POWER (1) The rate voltage of this product is monophase (230V/1Ph/50 Hz) / triphase (400V/3Ph/50Hz). (2) Use a circuit breaker an receptacle matched to the capacity of the room air conditioner. 9

4- WIRING DIAGRAMS SDC/H 050 / 065 / 085 / 105 F SDC/H 105T F SDC/H 120 M2F The installation of electric assault to the machine, it should have a switch of Bipolar court or Tetrapolar according to machine model, (monophase or treephase), of at least 3 mm of separation among contacts (norm IN 60355-40). Reight Section mm 2 MODELS Power Supply* up to 25 m. Magnetothermique Defferential (V/Ph/Hz) Manoeuvre Force Type D 1 n SDC/H 050 F 230/1/50 1,5 2,5 15 A 0,03 A SDC/H 065 F 230/1/50 1,5 2,5 20 A 0,03 A SDC/H 085 F 230/1/50 1,5 4,0 25 A 0,03 A SDC/H 105 F 230/1/50 1,5 4,0 32 A 0,03 A SDC/H 105T F 400/3/50 1,5 2,5 10 A 0,03 A SDC/H 120 M2F 230/1/50 1,5 6,0 32 A 0,03 A * Always connect the ground wire. 10

XT220306/V01-9001872 Saunier Duval se reserva el derecho de introducir modificaciones sin previo aviso www.saunierduval.es