UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

Similar documents
Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

Technical data. Danfoss DHP-A

SEALED THERMAL STORE

Technical data. Danfoss DHP-L

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Instructions for Use Installation and Servicing

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

DHP-H Varius Pro+/DHP-L Varius Pro+

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Alpha CombiMax 350 and 600

This manual must be kept with the appliance

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

the electric heating company ELECTRIC BOILER HANDBOOK

Unvented water heater

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Unvented water heater

Unvented Hot Water Storage Cylinders Installation and Maintenance Instruction Manual

Powerflow Unvented water heater

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Multipoint Technical Data

Planning guide. Atec.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

VAILLANT SPARE PART CATALOGUE

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

Unvented Direct & Indirect Hot Water Cylinders (400L L)

MULTIPOINT SS H 50/80 & 100

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

Schuco SS-TC/SC Cylinders

Installation instructions Danfoss heat pump DHP-R

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

Unvented Direct & Indirect Hot Water Cylinders (400L L)

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

unistor Instructions for Installation and Use Unvented hot water storage cylinder

PremierPlus Unvented Hot Water Cylinder Installation and User Manual

Multipoint ECO Horizontal Litres Installation, operation and maintenance manual

Quantum. Installation, User and Service Manual. Hot Spring

Unvented Hot Water Storage Cylinders

Technical and Installation manual All Models

Installation and User Instructions HS10U, HS15U.

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Spare Parts Guide & Price List

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Understand and apply domestic hot water system installation, commissioning, service and maintenance techniques

Installation Manual EXCELSIOR Unvented Water Heater

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

Unvented Electric Water Heater 10/15 litre Undersink

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

DELTA Ultimate technology

T E C H C A L EBS-1 T High technology heating

EPU - WM30 EPU - WM 50 EPU - WM100

Copper-Fin GAS-FIRED WATER HEATERS

ADVANCE ECB ELECTRIC COMBINATION BOILER

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

FASTflo. Working towards a cleaner future

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Installation and Servicing Instructions. Alpha SolarSmart 90

Hotflo Vertical Litres Installation, operation and maintenance manual

Installation & User Instructions

Megaflo Eco SystemReady Unvented Indirect Hot Water Cylinders

INSTALLATION MANUAL. Domestic hot water tank with UK kit for air to water heat pump system EKHTS200AC EKHTS260AC EKHTSU200AC EKHTSU260AC EKUHWHTA

ADVANCE ELECTRIC THERMAL STORE

Combined electric boiler and domestic hot water store

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

Installation Instructions. Unvented hot water storage cylinders for use with Vaillant boilers

Advance Stainless Steel Unvented Hot Water Cylinders for Heat Pump Systems. Installation and Commissioning Manual

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Megaflo Eco Slimline Unvented Direct & Indirect Hot Water Cylinders 100L - 200L

Diplomat Inverter/Diplomat Duo Inverter

HT V2 HT Split

Installation and Servicing Instructions. Alpha GasSaver GS-1

Itho Solar System CombiSolar 150. Installation and service manual

Technical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Design, Installation, User & Servicing Instructions

Design, Installation, User & Servicing Instructions

Technical description. Atec.

INSTALLATION AND MAINTENANCE INSTRUCTIONS MOS GB NIBE VVM 300 UK NIBE VVM 300 UK 230 V VVM 300 LEK

SMART SHOWERS ELITE SP P0985 READ ME THIS IS A HIGH PERFORMANCE HIGH SPECIFICATION PUMP AND HAS PRECISE INSTALLATION REQUIREMENTS

Operating instructions

User manual DHP-AQ VUGFB102

WATER HEATERS INSTALLATION MANUAL

Transcription:

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro VIBMB402 086U8255 Rev 4

To be read together with Installation instructions Contents 1 Important information/safety regulations................... 3 1.1 Test results................................................. 3 2 About documents and labels............................... 4 2.1 Manufacturer labels......................................... 4 3 Piping installation.......................................... 8 3.1 General..................................................... 8 3.2 System solution............................................ 9 3.3 Discharge pipe arrangement............................... 13 4 Commissioning............................................ 14 4.1 How to flush the tap water system......................... 14 4.2 How to drain the tap water system......................... 14 4.3 Inspection access.......................................... 14 2 Appendix UK

1 Important information/safety regulations D D D D D D D D D D D D E E These instructions are a UK-specific appendix to those instructions found in the Installation instructions. Read the Installation instructions prior to installation. For DHP Opti Pro SP (Single Phase) heat pumps it is imperative that the maximum hot water temperature is altered from the default factory setting from 95 C to 60 C. Refer to Chapter 9.8 menu Service HGW Parameter MAX TEMP in Installation instructions. Hard Water Areas; Normally it is not a problem to install a heat pump in hard water areas since the normal domestic hot water working temperature will be not greater than 60 C. In areas where exceptional water conditions prevail, consideration may need to be given to the fitting of a device capable of inhibiting scale. In such circumstances the advice of the local water authority should be sought. The immersion heater, thermostat, and thermal cut-out are supplied by Danfoss and are factory fitted. If a replacement part is necessary, it must be replaced with a Danfoss spare part. The water heater is protected with a sacrificial aluminium anode. Under normal circumstances no maintenance is needed. Note! Leave the following documents with the end-user; - This manual - Installation instructions - User manual The above documents are an integral and essential part of the product. They should be kept with the appliance so that they can be consulted by the user and our authorised personnel. Please read carefully the instructions and notices about the appliance contained in this manual, as they provide important information regarding the safe installation, use and maintenance of the heat pump. 1.1 Test results 1.1.1 Heat up time The heat up time is measured when heating the water from 14 C to 60 C. DWH 300: Heat up time 1 hour 53 minutes DHP-H, DHP-A, DHP-AQ Maxi and DWH 200: Heat up time 1 hour 3 minutes 1.1.2 Re-heat time The re-heat time is measured when 70% of the hot water has been drained and replaced by equal amount 14 C water and re-heated to 60 C. DWH 300: Re-heat times 70% 1 hour 25 minutes DHP-H, DHP-A and DWH 200: Re-heat time 70% 41 minutes DHP-AQ Maxi: 1 hour 6 minutes according to EN12897. 1.1.3 Pressure drop The measured pressure drop throgh the primary heater is 15 kpa. 1.1.4 Hot water capacity DHP-AQ Maxi: 160 liter according to EN12897. Appendix UK 3

2 About documents and labels 2.1 Manufacturer labels The heat pump and the indoor unit are marked with durable, permanently fixed labels. 2.1.1 Manufacturer label: P. O. Box 950 SE-67129 Arvika Sweden DHP-H 6 Heat Pump Source of heat Max Mpa 0,3 System of heat Max Mpa 0,3 Source of heat Min/Max C -10 / +20 Refrigerant Type *R407C Operation Pressure Min/Max MPa 0,08/3,1 Refrigerant Kg 1.2 IP 21 Connection Electric connection V 400 3N~50Hz Power input Total kw 5,0/8,0/11,0 Power input Heat pump kw 2.0 Power input Auxiliary Heater kw 3/6/9 Pressure Vessel Volume Sec/Prim l 1/7.5 Design Pressure Sec/Prim MPa 1.0 / 0.3 Test Pressure Sec/Prim MPa 1.43 / 0.43 Design Temp C 100 Rating condition EN 14511 B0W35 A2/W35 A7/W35 (see technical documentation) Heating capacity kw 5.33 -- -- Coefficient of Performance 4.04 -- -- * This product contains fluorinated greenhouse gases covered by the Kyoto Protocol -- Serial No 086U5000*testBRE 086U5000*testBRE Model -- YY-WW 09-33 4 Appendix UK

2.1.2 Manufacturer label: DHP-AQ P. O. Box 950 SE-671 29 Arvika Sweden DHP-AQ CONTROL MAXI 6-13 SP Heat Pump Source of heat Max Mpa 0 System of heat Max Mpa 0 Source of heat Min/Max C Refrigerant Type * Operation Pressure Min/Max MPa -- Refrigerant Kg IP x 2 Connection Electric connection V 230 1N~50Hz Power input Total kw 3.1/6.1/9.1 Power input Heat pump kw Power input Auxiliary Heater kw 3/6/9 Pressure Vessel Volume Sec/Prim l 1/7.5 Design Pressure Sec/Prim MPa 1.0 / 0.3 Test Pressure Sec/Prim MPa 1.43 / 0.43 Design Temp C 100 Rating condition EN 14511 B0W35 A2/W35 A7/W35 (see technical documentation) Heating capacity kw -- Coefficient of Performance -- * This product contains fluorinated greenhouse gases covered by the Kyoto Protocol -- Serial No 086U0283xxxxxxxx 086L0283xxxxx Model CU-*104-303 YY-WW 11-27 Appendix UK 5

2.1.3 Additional label: This label will ensure that this product conforms to the requirements of United Kingdom Building Regulations. The information is entirely valid in a UK specific installations. Heat Pump *) Weight when full (kg) DHP-H 4 405 DHP-H 6 409 DHP-H 8 409 DHP-H 10 409 DHP-H 12 418 DHP-H 16 422 DHP-A 6 440 DHP-A 8 440 DHP-A 10 440 DHP-A 12 448 *) Incl. DHP Opti and Opti Pro Maximum water supply pressure Pressure reducing valve Expansion valve Expansion vessel charge pressure Operating pressure Temp and pressure release valve Maximum primary working pressure Immersion heater 10 bar 3 bar 6 bar 3 bar 5,5 bar 10 bar; 90 95 C 1,5 bar D76 / 9 kw / 230 V WARNING TO THE USER (a) Do not remove or adjust any component part of this unvented water heater. Contact the installer. (b) If this unvented water heater develops a fault, such as a flow of hot water from the discharge pipe, switch the heater off and contact the installer. WARNING TO THE INSTALLER (a) This installation is subject to building regulation approval, notify the Local Authority of intention to install. (b) Use only manufacturer's recommended replacement parts. (c) INSTALLED BY: Name. Address. Tel No. Completion date. 6 Appendix UK

2.1.4 Additional label: DHP-AQ Control Maxi 6 13 SP This label will ensure that this product conforms to the requirements of United Kingdom Building Regulations and EN12897:2006. The information is entirely valid in a UK specific installation. Weight when full PT valve replacement no. Oper. temp non self-reset. thermostat Maximum flow temperature Operating pressure heat source Primary heating power input Primary flow rate Actual capacity Standing heat loss Maximum water supply pressure Pressure reducing valve Expansion valve Expansion vessel charge pressure Operating pressure Temp and pressure release valve Maximum primary working pressure Immersion heater 286 kg 086U8267 88 C 65 C 1 bar 9 kw 0,16 0,31 l/s 1 liter 1,8 kwh / 24 h 10 bar 3 bar 6 bar 3 bar 5,5 bar 10 bar; 90 95 C 1,5 bar D76 / 9 kw / 230 V WARNING TO THE USER a) Do not remove or adjust any component part of this unvented water heater. Contact the installer. b) If this unvented water heater develops a fault, such as a flow of hot water from the discharge pipe, switch the heater off and contact the installer. WARNING TO THE INSTALLER a) This installation is subject to Building Regulations notification. b) Use only appropriate components for installation and maintenance. c) INSTALLED BY: Name. Address. Tel No. Completion date. Appendix UK 7

3 Piping installation 3.1 General In section 5.2 you will find connection diagrams. 3.1.1 Unvented package DHP and DWH200 Danfoss code reference UNV01. Package contents: Position Danfoss code Number Description 110 FITT0050 1 Expansion vessel 19 liter - FITT0052 1 Expansion vessel bracket 132 FITT0053 1 Flexible hose - FITT0001 1 Tundish 15x22 mm 129 FITT0054 1 Unvented manifold assembly 3.1.2 Unvented manifold assembly E A D B C Figure 1. Unvented manifold assembly. Position Name A Pressure reducing valve B Non-return valve C Cold water to house D To expansion vessel E Safety relief valve 3.1.3 Temperature and pressure relief valve Figure 2. Factory fitted Temperature and pressure relief valve 8 Appendix UK

3.2 System solution 3.2.1 Unvented package installation, DHP-H and DHP-A models 10 11 91 12 86 113 85 129 128 12 126 132 110 Unvented manifold assembly (see figure 1) DHP-H DHP-A E E Figure 3. The principal installation solution of the unvented package on DHP-H and DHP-A models. Position Name 10 Supply line heating system 11 Return line heating system 12 Cold water Shut-off valve 85 Venting valve 86 Safety relief valve heating system 91 Strainer Flexible hose 110 Expansion vessel 113 Expansion heating system 126 Factory fitted combined Temperature and pressure relief valve* 128 Double check valve with Shut-off valve 129 Unvented manifold assembly: Pressure reducing valve, Safety relief valve, Non-return valve 132 Flexible hose Unvented package *) The water heater tank in DHP-H and DHP-A models is factory fitted with a Temperature and pressure relief valve. The connection from this valve must not be used for other purposes other than discharge pipe connection. Please see chapter 5.3 Discharge pipe arrangement. Note! No valve should be fitted between the safety relief valve and the storage cylinder. Appendix UK 9

3.2.2 Unvented package installation, DHP-L models, DWH 200, DWH 300 10 11 104 91 13 12 86 113 129 128 12 126 132 Unvented manifold assembly (see figure 1) 110 DHP-L DWH 200 DWH 300 E E Figure 4. The principal installation solution of the unvented package on DHP-L models together with DWH. Position Name 10 Supply line heating system 11 Return line heating system 12 Cold water 13 Hot water Shut-off valve 86 Safety relief valve heating system 91 Strainer Flexible hose 104 Safety relief valve 2,5 bar 110 Expansion vessel 113 Expansion heating system 126 Factory fitted combined Temperature and pressure relief valve* 128 Double check valve with Shut-off valve 129 Unvented manifold assembly: Pressure reducing valve, Safety relief valve, Non-return valve 132 Flexible hose unvented package *) The water heater tank in DWH is factory fitted with a Temperature and pressure relief valve. The connection from this valve must not be used for other purposes other than discharge pipe connection. Please see chapter 5.3 Discharge pipe arrangement. Note! No valve should be fitted between the safety relief valve and the storage cylinder. 10 Appendix UK

3.2.3 Unvented package installation, DHP-L Opti Pro models, DWH 200, DWH 300 10 11 104 91 13 12 86 113 129 128 12 126 132 Unvented manifold assembly (see figure 1) 110 DHP-L Opti Pro DWH 200 DWH 300 E E Figure 5. The principal installation solution of the unvented package on DHP-L Opti Pro models with DWH Position Name 10 Supply line heating system 11 Return line heating system 12 Cold water 13 Hot water Shut-off valve 86 Safety relief valve heating system 91 Strainer Flexible hose 104 Safety relief valve 2,5 bar 110 Expansion vessel 113 Expansion heating system 126 Factory fitted combined Temperature and pressure relief valve* 128 Double check valve with Shut-off valve 129 Unvented manifold assembly: Pressure reducing valve, Safety relief valve, Non-return valve 132 Flexible hose Unvented package *) The water heater tank in DWH is factory fitted with a Temperature and pressure relief valve. The connection from this valve must not be used for other purposes other than discharge pipe connection. Please see chapter 5.3 Discharge pipe arrangement. Note! No valve should be fitted between the safety relief valve and the storage cylinder. Appendix UK 11

3.2.4 Unvented package installation, DHP-AQ Maxi 10 11 113 85 12 13 128 126 129 12 132 110 Unvented manifold assembly (see figure 1) 5 100 DHP-AQ Maxi 71 E E Figure 6. 91 The principal installation solution of the unvented package on DHP-AQ Maxi Position Name 5 Heat pump unit 10 Supply line heating system 11 Return line heating system 12 Cold water 13 Hot water 71 Flow guard Shut-off valve 85 Venting valve 91 Strainer Flexible hose 100 Safety relief valve 110 Expansion vessel 113 Expansion heating system 126 Factory fitted combined Temperature and pressure relief valve* 128 Double check valve with Shut-off valve 129 Unvented manifold assembly: Pressure reducing valve, Safety relief valve, Non-return valve 132 Flexible hose Unvented package *) The water heater tank in DHP-Q Maxi models is factory fitted with a Temperature and pressure relief valve. The connection from this valve must not be used for other purposes other than discharge pipe connection. Please see chapter 5.3 Discharge pipe arrangement. Note! No valve should be fitted between the safety relief valve and the storage cylinder. 12 Appendix UK

3.3 Discharge pipe arrangement B B D D The tundish must be positioned away from any electrical devices. The tundish must be installed so that it is visible to the occupants. 1 2 600 mm maximum 3 300 mm minimum 4 5 Figure 7. The principal installation solution of the discharge pipe assembly. Position Name 1 Safety device (for example, temperature relief valve) 2 Metal discharge pipe from safety device to tundish 3 Tundish 4 Discharge pipe from tundish, with continuous fall (1 in 200) 5 Discharge below fixed grating 6 Trapped gully Sizing of copper discharge pipe (4) for common temperature relief valve outlet sizes Valve outlet size Minimum size of discharge pipe (2) G1/2 15 mm G3/4 22 mm G1 28 mm Minimum size of discharge pipe (4 from tundish) Maximum resistance allowed, expressed as a length of straight pipe (that is, no elbows or bends) 22 mm Up to 9 m 0.8 m 28 mm Up to 18 m 1.0 m 35 mm Up to 27 m 1.4 m 28 mm Up to 9 m 1.0 m 35 mm Up to 18 m 1.4 m 42 mm Up to 27 m 1.7 m 35 mm Up to 9 m 1.4 m 42 mm Up to 18 m 1.7 m 54 mm Up to 27 m 2.3 m 6 Resistance created by each elbow or bend Appendix UK 13

4 Commissioning 4.1 How to flush the tap water system When the tap water and the heating system have been filled up, the unit shall be running at maximal, normal operating temperature for a minimum of one hour. After that the tap water system shall be flushed out and re-filled. 4.2 How to drain the tap water system E E After the tap water system has been flushed out, the cold and hot water pipes and the water heater tank need to be drained. To drain the system follow the instructions below: 1. Close the shut-off valve on the incoming water supply. 2. Open both cold and hot water taps which are situated as low as possible in the building to depressurise the system. Please note that there can be some water remaining in the cold water pipe which must be taken care of when loosening the pipe. EE 3. Loosen and remove the cold water pipe at the top of the heat pump. 4. Insert a plastic hose to use as a siphon into the cold water connection and bring it to the bottom of the water heater tank. 5. Place the other end of the hose near a gully. 6. Use the siphon effect to empty the water heater tank. DFor location and dimension of connections, please see chapter 4.1 in the Installation Instructions. 4.3 Inspection access The hot water tapping connection can be used as an inspection access. 14 Appendix UK

Appendix UK 15