floor heating system

Similar documents
ELEKTRA HEATING MATS. Designed to be installed under laminate flooring and/or engineered wood UK PL RU. Installation manual

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

Underfloor Heating Cable Installation Manual

Underfloor Heating Mat Installation Manual

Uponor Comfort E AL-Foil Mat

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

ELEKTRA RadiantFloor Heating

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Single-side powered heating cables

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

Installation Instruction

Heating Mats. Single-side power supply Double-side power supply

Intro. Intro. Table of Contents

Installation Guide For your AHT Underfloor Heating System

electric floor heating for everyone Heating mats Heating cables Temperature controllers

electric floor heating Heating mats Heating cables Temperature controllers

Undertile Heating Mat. Instructions. CORGI Underfloor Heating - Quality, Flexibility, Safety 1

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co.

electric floor heating Heating mats Heating cables Temperature controllers

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

HEATING USER GUIDE. Philex Support Line: Monday to Friday 9.00am to 5.00pm (Local rate - UK only)

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Royden. Look how easy it is to roll out the heat

Electric Warm-Stretch under floor heating

emat Pro 100/150/200 Installation Manual

amuheat Cable Mat floor heating systems Installation Manual CM02-12

LIFETIME. INSTALLATION MANUAL efoil WARRANTY

Underlaminate Foil Heater

FloorHeat Installation Manual

Underwood Heater Installation Manual

ELECTRIC UNDERFLOOR HEATING SYSTEMS. Operating Guide & Guarantee. The Underfloor Heating Specialists Tel:

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

Installation And User Instructions

UNDERWOOD HEATING SYSTEM

HANDBOOK FOR COMFORTABLE WARM FLOORS

Carbon Film Installation Instructions

DOMOTHERM CLASSIC TWIN/S MAT

Installation And User Instructions. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Underfloor Heating Inscreed Cable System

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet

WATCH OUT! UNDERNEATH THE WOODEN FLOORING IS A 230 VOLT HEATING FOIL SYSTEM! NEVER DRILL OR SCREW INTO THE FLOOR!

TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP years warranty

Always make sure to check the heating film before, during, and after installation of the floor covering.

Classic Mats Installation Manual

ELECTRIC HEATING THERMOSYSTEM

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

INSTALLATION INSTRUCTIONS

I.D.L. Heaters Thermal Products Ltd. IdealMat Installation Manual

CASE STUDY UNDER FLOOR HEATING. Electric Underfloor Heating Display Stand

Installation Manual. Warmset. Warmset srl. Floor heating system

TXLP Heating Cable Nexans Underfloor Heating. TXLP Nexans Underfloor Heating

Electric Under Floor Heating

4 1 Heating. wooden floors or renovated floors.

IdealFILM. Do-It-Yourself Installation Manual

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

Installation And User Instructions. devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

INSTALLATION INSTRUCTIONS ONE LARGE ZONE

INSTALLATION INSTRUCTIONS SINGLE CIRCUIT

Installation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com

MONTAGE INSTRUCTIONS OF HEAT DECOR S HEATING FILM BELOW CONCRETE OR TILES

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS

Electrical Heating Solutions. Energy efficient building technology

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

Click & Plug Floor Heating. Installation instruction Devidry Kit

Installation Manual. Warmset. Warmset srl. Floor heating system

Toll Free:

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

Assembly instructions and instructions for use for electric sauna oven with evaporator. Bi-O-Mat W MADE IN GERMANY IPX en / -44.

HEAT CABLE underfloor heating

Installation Instruction Devidry - for installation with Devidry Pro Kit

Under Carpet Heater Kit Installation Guide

Introduction. Please read the following instructions carefully before commencing installation.

Under-floor heating system The technology of tomorrow

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable

EN-SUITE & KITCHEN HEATING

ATC Electric Under Floor Heating

Foil Heating System. Installation Manual. for Carpet and Laminate TECHNICAL HELPLINE 0800 WARMUP ( )

US: CA:

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

Installation Guide Heating Elements

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

INSTALLATION INSTRUCTIONS

English. Dear Client,

Underlaminate Foil Heater

Polymer solutions Heating mat EM2-CM

Overview Frost Heave Prevention for Freezer floors on ground.

amuheat Laminate Panel 14 floor heating systems Installation Manual LP12-V1

Installation and User Guides

Self Regulating Trace Heating Systems Installation and Maintenance. Non-Hazardous Area Installations

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

F1202 TRACE HEATING. Road & Ramp

Installation instructions

2 KW OIL FILLED RADIATOR

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

Catalogue SPREAD THE WARMTH

Transcription:

floor heating system Installation manual Instrukcja montażu Инструкция по установке EN PL RU

EN The package contains: Thin self-adhesive heating mat Thermostat and temperature sensor (option) Installation pipe for the temperature sensor Instruction manual You can do it yourself By following the simple instructions, you will be able to install ekomat yourself without any problems. Only its connection with the mains should be carried out by a qualified electrician.

The will provide you with heat comfort resulting from favourable temperature distribution -the, so-called, warm feet -cool head. 16 18 20 22 24 26 0 C Vertical temperature distribution within the room for various types of heating. electric floor heating ideal profile convection heaters, located near indoor walls air heating 3

Why will the warm up your life? reliable performance itis simple to install only desired areas are heated or warmed up uniform temperature is in the whole room can be installed on existing tiles -without removal because it is thin, the floor level is only slightly raised nomaintenance safe: with the power supply protected by an RCD (Residual Current Device), risks are eliminated, the cable is screened and earthed all you have to do is set the thermostat to your desired temperature and -your floor will soon be warm and dry Where can be used? everywhere -in new building projects or renovations it is especially useful in renovated kitchens, bathrooms, anterooms, halls... as raising the floor level is kept to a minimum on any base: on concrete floors, on existing (old) ceramic tiles, terrazzo, moisture - proof chipboards 4

What kind of floor finishes are compatible with? in general, ceramic, porcelain and natural stone floor tiles, which provide optimal heat transmission; also compatible are : wooden mosaic, oak parquet or laminated floor panels carpet (check compatibility) vinyl (check compatibility) Look for quality marks that indicate compatibility with Electric Underfloor Heating: How is manufactured? It is produced in ready-made kits. The heating cable is attached to a plastic mesh, connected to a'cold tail' supply cable 4m long. The plastic mesh is coated with adhesive to enable the mat to stick to the base floor. The mat thickness is approx. 3.5mm. 5

a heating cable joint supply ( cold tail ) cable Types of mat type dimensions area power 100 W/m 2 100/1.0 100/1.5 100/2.0 100/3.0 100/4.0 100/5.0 100/6.0 100/8.0 100/10.0 2 [m xm] [m] [W] 0.5 x 2.0 1.0 100 0.5 x 3.0 1.5 150 0.5 x 4.0 2.0 200 0.5 x 6.0 3.0 300 0.5 x 8.0 4.0 400 0.5 x 10.0 5.0 500 0.5 x 12.0 6.0 600 0.5 x 16.0 8.0 800 0.5 x 20.0 10.0 1000 Note: the nominal power output may differ by +5, -10% 6

160 heating mats 160W/m 2 mat type dimensions area power 160 W/m 2 [m xm] 2 [m] [W] 160/1.0 0.5 x 2.0 1.0 160 160/1.5 0.5 x 3.0 1.5 240 160/2.0 0.5 x 4.0 2.0 320 160/2.5 0.5 x 5.0 2.5 400 160/3.0 0.5 x 6.0 3.0 480 160/3.5 0.5 x 7.0 3.5 560 160/4.0 0.5 x 8.0 4.0 640 160/5.0 0.5 x 10.0 5.0 800 160/6.0 0.5 x 12.0 6.0 960 160/7.0 0.5 x 14.0 7.0 1120 160/8.0 0.5 x 16.0 8.0 1280 160/10.0 0.5 x 20.0 10.0 1600 Note: the nominal power output may differ by +5, -10% 2 The mats of 160W/m can beinstalled only under floor tiles. The mats of 100W/m2 power can be installed under any floor type. What is the thermostat used for? It controls the mat performance by means of atemperature sensor, located between the heating cables, i.e., directly in the floor. With the temperature sensor, you can maintain desired floor temperature. The connection of the heating mat to the electric mains is possible only via the thermostat! The connection can only be done by a qualified electrician. 7

Where tostart? 1) Measure the part of the floor on which the heating mat istobeinstalled. Note: If you start the installation works in a new build with no fixed furniture - draw (mark) the fixed elements (cabinets, a bathtub, a toilet, a shower, etc.) on the floor and calculate the area to be heated. Calculate the area of the "free" floor and choose an appropriate mat. 2) Install aninstallation box for the thermostat, ready for the power supply tobeinstalled. Remember! At a later stage of installation works, you are going to install the thermostat in that installation box. The thermostat should be placed (for aesthetic and practical reasons) close to light switches - perhaps within the same frame. 8 wall box temperature sensor

Very important! The thermostat should be mounted on the outside bathroom or sauna wall for protection against moisture and tocomply with regulations. 3) Install two (2) conduits from the installation box (the inside dia. minimum 11mm) to the floor. For aesthetic reasons, lay them inpreviously made chases in the wall. a) Later on (at the stage ofthe mat installation), you are going toinsert acable with the temperature sensor into one ofthe conduits. a 230V conduit cable a junction box a conduit for the mat feeder ( cold ) cable inlet a conduit for the temperature sensor inlet the so-called pilot (for cable fishing) 9

Remember! The temperature sensor should be placed possibly at the centre of the heated surface -therefore, the conduit (laid in the groove, cut in the floor) should "enter" the heating zone. b) the cold tail cables will be inserted into the other conduit. Cut out agroove inthe floor (but much shorter) and lay aconduit in it, leading ittothe installation box. Very important! The conduits cannot be bent at a right angle (at the contact of the wall with the floor); a smooth bend should be maintained. Before fixing the mat 1) Clean the base on which the mat istobelaid a) level the surface b) carefully scrub any old tiles 2) Install the cable with the temperature sensor (in the conduit under the wall plaster) upto the installation box. 3) Lay the conduit in the groove, previously cut in the floor. Important! Seal the end of the conduit with, for example, insulating tape to protect against tile adhesive oozing inside the pipe and damaging the temperature sensor. 10

Now start fixing the mat 1) Spread the mat out on the floor in such away as to avoid fixed furniture, such as a bathtub, a shower, a toilet, standing cabinets without legs... Note: In order to adjust the mat to size and shape of the free floor surface, you can cut the mesh, to which the heating cable is fixed. Remember! You must not damage the heating cable. You must not cut it! Where the mesh is cut, you must carefully straighten the loose cable and place the cut mat sections close to each other. Keep equal distances between heating cables. 11

Important: You have to lay the mat in such away as to allow supply ("cold") cable to reach the thermostat. Note: The temperature sensor has to be placed at an equal distance between heating cables. Important: After gluing the mat to the base, check the resistance of the core with an ohmmeter, and the insulation resistance of the core with a megaohmmeter. Note the result. After covering the mat with flexible tile adhesive or with self-levelling compound, you must measure the resistance again. It is necessary to make sure that the mat is not damaged during installation works. Very important: The heating cable of the mat should be covered with a 3 mm layer of tile adhesive or self-levelling compound. Important: The joint between heating cable and cold tail should be embedded in the flexible tile adhesive or self-levelling compound. 12 2) Prepare a plan indicating the mat layout and position of the floor sensor. Keep the drawing in order to facilitate, if necessary, locating the heating mat and the temperature sensor in the future. 3) Once the mat is fixed tothe base, coat it with a layer of flexible tile adhesive or self-levelling compound.

When the mat is already installed 1) Wait until the adhesive isdry. 2) Insert the cold tail cable into the installation box (through the conduit of course) -you may shorten the cold tail cable length, if necessary. 3) Measure again the resistance ofthe core and the insulation ofthe heating cable -compare with the initial value -note the result. the thermostat the heating mat feeding cable (in conduit) the conduit with the temperature sensor cable muff the heating mat feeding cable the temperature sensor (in conduit) 13

Remember! If you put more than one heating mat inone room, all the cold tails must be led tothe installation box /thermostat. Connecting the heating mat to the mains Important: Leave this task to a qualified electrician. Remember! The connection of the heating mat should be done through the thermostat -follow the circuit diagram. The protective cable (green-yellow) must be connected to the protective cable of the electric installation (green-yellow) by means of a clamp terminal on the thermostat. 14

thermostat PE N N L L 1 2 3 4 5 6 7 the 230V conduit green-yellow blue blue black black the temperature sensor cable the heating mat feeding cable the temperature sensor 15

Earth leakage protection The power supply should beequipped with an RCD (Residual Current Device) with 30mA sensitivity. Switching on the heating system Important: Only after complete drying ofthe tile adhesive and the grout, as specified bythe manufacturer. Your task: Set the desired temperature on the thermostat. The last advice Remember to avoid making changes in furniture layout that will affect heat radiation bythe floor: do not put objects with large surfaces on the floor, e.g.: mattresses, cabinets without legs If you have todrill holes, check itwith the cable layout plan first inorder to avoid damaging the heating cables. 16

The guarantee card The manufacturer provides a 10-year guarantee for and a 2-year guarantee for the thermostat from the date of purchase. The guarantee conditions 1. In order to have the submitted claim acknowledged: the installation of the heating mat should comply with the installation instructions the connection of heating mat and the thermostat to the electric mains, as well as measurements of the heating cable core and insulation resistance should be done by a qualified electrician the electric installation, supplying the heating circuit, should be equipped with an RCD a plan of the layout should be submitted the properly filled guarantee card (with product label) should be submitted 2. The guarantee does not cover defects, caused by: mechanical damage improper power supply 3. Regarding the guarantee, the manufacturer is obliged to incur costs, connected exclusively with the repair or replacement of a defective heating cable. 17

Guarantee Card Your 10 year guarantee commences on the date of purchase. This card must be retained for the duration of the guarantee. INSTALLATION ADDRESS Address Post Code Town DETAILS OF INST ALLER / ELECTRICIAN Name Address Post Code Town Any claim must be accompanied by this guarantee card & proof of purchase. Professional body enrolment number E-mail Tel. Fax

The electrician carrying out the electrical connections / installation must provide a test certificate. Sketch of Heating Layout

Heating core and insulation resistance Date After heating mat installation, before floor installation Ω MΩ Installer s signature Company stamp After floor installation Ω MΩ Caution: The measurement results of the heating core s resistance should not vary from the one given on the nameplate with more than -5% and +10%. Resistance of the heating wire insulation should be at least 10 MΩ when measured with a megaohmmeter (Insulation Resistance Tester) with a rated voltage of 1000V.