Installation & User Instructions

Similar documents
Installation and User Guide. Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU)

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU)

MAKING MODERN LIVING POSSIBLE. SET 3E Electronic 24 Hour Programmer for Heating and Hot Water. Installation Guide. Danfoss Heating

102E7. Installation & User Instructions. 7-day electronic mini-programmer for controlling hot water and heating

MAKING MODERN LIVING POSSIBLE. SET 1E Electronic Timeswitch for Heating and Hot Water. Installation Guide. Danfoss Heating

CET B-RF Wireless Electronic Hot Water Cylinder Thermostat User & Installation Instructions

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

CET2000B-RF + RX1-S + CS2

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

User Operating Instructions Horstmann 425 Tiara/Diadem Electro-mechanical Programmers

103E7. User Guide. 7-Day Electronic Timeswitch for Controlling Hot Water and Heating (Including Factory Replacement Units FRU) Danfoss Heating

Electronic Dual Cylinder Thermostat Installation Instructions

425 Coronet Electro-mechanical Timeswitch User Operating Instructions

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

ES3247B. 3 Channel Programmer. User and Installation Instructions

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

MAKING MODERN LIVING POSSIBLE RET2000 B/M/MS. Electronic digital thermostat with LCD User Guide. Danfoss Heating

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

CentaurPlus ZW and HRT4-ZW

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

Digital Room Thermostat

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Control Packs Catalogue. Including control packs compliant with 2013 Building Regulations: Part L

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

DOMESTIC HEATING CONTROLS ARE EASY PART 2 - TIMERS & PROGRAMMERS

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

CentaurPlus C21 Series 2 User Operating Instructions

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

4 in 1 Digital Thermostat Control

Installation & Operating Instructions

CentaurPlus C27 Series 2 User Operating Instructions

Heating Controls Technical

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

8000 Series Programmable & Non-Programmable Thermostats for Heat/Cool Applications

CREDA STORAGE RADIATORS

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

ESRTD3. Digital Room Thermostat with TPI & Delayed Start. User and Installation Instructions

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Statesman. Users Instructions. 45/50, 50/70, 70/90, 90/110, System, Flowsure, Flowsure +, Utility 50/70, 70/90, 90/110, 110/130, 130/150

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

425 series Electro-mechanical Programmers

User's Instructions. Alpha CB50

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

RF Programmable Room Thermostat Installation Instructions

RT021 User and Installation Instructions

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

3 Channel Multi-Purpose Programmer User Instructions

TPOne-S. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

E-COMBI EVO E-SYSTEM EVO

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

INSTALLATION AND USER INSTRUCTIONS TOWERCHRON QE1/QE2. WA-EKF 4042/05.01/S:MMS/D:Bau/00/00344/

Digital Thermostat Models: VS30W and VS30B

Electronic timeswitch

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

HEATING & HOT WATER GUIDE FOR SHARED BOILER & HEATING SYSTEMS

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Electronic 7 Installation Instructions

4iE Smart WiFi Thermostat Operating Guide

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

time SWITCH hour time clock Art.-No

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

The guarantee on this appliance is valid for 12 months from the first day of installation.

Programmable Room Thermostat Installation Instructions

Cat. No TPT44. Installation & Operating Instructions

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Battery Powered Electronic Programmable Room Thermostat

ECL Comfort V a.c. and 24 V a.c.

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Installation and User Guide eco Intelligent Radiator Thermostat

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Phone: * Website: wiser.draytoncontrols.co.uk /DraytonHome

INSTALLATION INSTRUCTIONS

ACCESSOIRES ELECTRICAL ACCESSORIES

ES-LCD User Control SD Card Location

ECL Comfort V a.c. and 24 V a.c.

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

MURELLE EV HE 25/55-30/55

GENERAL DESCRIPTION AND INSTRUCTIONS FOR KFG CONTROL

MAINTENANCE AND SERVICE GUIDE

GreenCon On/Off Room Thermostat

Transcription:

3060 electro-mechanical programmer for controlling heating & hot water Installation & User Instructions This product complies with the following EC Directives: Electro-Magnetic Compatibility Directive. (EMC) (2004/108/EC) Low Voltage Directive. (LVD) (2006/95/EC)

Index Installation Product specification 3 Installation 4 Wiring 4-5 User Your programmer 6 Programming the unit 6-7 Setting the clock 7 Using the programmer 8-9 Contact details 12 INDEX 2

Installation Instructions Please Note: This product should only be installed by a qualified electrician or competent heating installer, and should be in accordance with the current edition of the IEEE wiring regulations. Product specification Specification Power supply Switch action 230 ± 15% Vac, 50/60Hz 2 x SPST, type 1B Switch rating Max 264 Vac, 50/60Hz, 3(1) A Timing accuracy ± 1 min/month Enclosure rating IP30 Max. ambient temperature 55 C Dimensions, mm (W, H, D) 102 x 210 x 60 Specification Design standard EN 60730-2-7 Construction Class 1 Control Pollution Situation Degree 2 Rated Impulse Voltage 2.5kV Ball Pressure Test 75 C 3

Installation 1. Remove lower setting dial. Set all four tappets to top of upper dial. Unscrew 4BA screw and remove outer case. 2. Slacken two screws securing plug-in module to backplate and separate module from backplate by pulling upwards. 3. Fix backplate to wall (3 hole fixing). 4. Referring to wiring diagrams below and opposite make electrical connections as shown (as applicable). The diagrams indicate that terminals 3 and 5 are not internally connected to the programmer and may therefore be used as spare wiring terminals if required. 5. Ease of installation can be achieved by the use of the Danfoss Randall Wiring Centre which is obtainable from most Builders Merchants and Distributors. Installation 3060 NOTE: If a Wiring Centre is used follow the installation instructions included with that unit and not the following wiring diagrams. 6. Secure cable cores under cable clamp. 4

Wiring WIRING - FULLY PUMPED SYSTEM 1 2 3 4 5 6 7 3060 Terminals Mains N L Supply Danfoss Randall RMT230 Room Stat 1 4 (N) 2 3 core 2 core 1 Danfoss Randall ATC Cylinder Stat 2 3 3 core 2 core + 1 2 3 4 5 6 7 8 9 10 S/L L N Brown Grey Orange Blue Flying lead Brown Orange Grey Blue Flying lead 3 or 4 core Danfoss Randall HP22 or HP28 SRZV (Heating) Danfoss Randall HP22 or HP28 SRZV (Hot Water) N L Boiler N L Pump Permanent line supply for boiler if required NOTE: This unit is NOT suitable for use with fully motorised zone valves requiring both ON and OFF electrical signals when used in the heating circuit WIRING - GRAVITY HOT WATER SYSTEM 1 1 2 3 4 5 6 7 2 Danfoss Randall RMT230 Room 4 Stat N L Pump N L Boiler 3 2 Danfoss Randall ATC Cylinder Stat 1 3060 Terminals Mains N Supply L 5Wiring

User Instructions Your programmer The 3060 programmer allows you to switch your hot water and heating on and off at times that suit you. Your Programmer & Programming the unit Four tappets on the timing dial let you decide when you want your hot water and heating to come on and go off each day. The programmer provides 2 ON times and 2 OFF times per day. Using the lower dial you can choose how you control your Heating and Hot Water, either at the set times, constantly ON, constantly OFF (each in different combinations). During the summer the central heating can be turned off, whilst still controlling the hot water at the set times. Programming the unit There are four TAPPETS on your timing dial, two red and two blue: o o the red tappets are the ON switches the blue tappets are the OFF switches 1. Hold the central black & silver knob with one hand and move the red tappet marked A clockwise to the time you want your HEATING/HOT WATER to switch on in the morning. 6 NB. you may find the tappets quite stiff, so you may have to push them quite firmly to move them.

2 Still holding the central knob, move the blue tappet marked B to the time you want your HEATING/HOT WATER to switch off in the morning. 3 You can set your other two tappets in the same way to set your HEATING/HOT WATER for the afternoon or evening. EXAMPLE (NB. Clock is in 24 hour mode) If you want your heating and hot water ON between 7am and 10am and ON again between 5pm and 11pm, set tappets as follows: A at 1st ON time = 7 B at 1st OFF time = 10 C at 2nd ON time = 17 D at 2nd OFF time = 23 Setting the Clock o Turn the dial clockwise until the correct time is lined up with the dot labelled TIME NB. clock is in 24 hour mode! REMEMBER You will have to reset the time after a power cut and also when the clocks change in Spring and Autumn 7Setting the clock

Using the Programmer The selector switch is used to select how the 3060 controls your hot water and heating. The heating and hot water can be operated together in various combinations, or the water can be controlled on its own (i.e. during the summer when only hot water is required). H+W ON H - ONCE W - ONCE H - TWICE W - ONCE H - TWICE W - TWICE H - OFF W - TWICE Using the programmer H+W OFF There are six positions into which the selector switch may be set. 1 - H OFF / W OFF Both Heating and Hot Water will remain OFF until you change the setting. 2 - H TWICE / W TWICE In this position the Heating and Hot Water will both come on and go off according to the times you have programmed (ON at A, OFF at B, ON at C, OFF at D). 8 3 - H ONCE / W ONCE This setting overrides tappets B and C, so both Heating and Hot Water will switch ON at the time marked by tappet A and will stay on until the time marked by tappet D. Both services will then switch OFF until A the next day.

4 - H ON / W ON This is the CONSTANT position and the programmer will remain permanently ON for both Heating and Hot Water, irrespective of the position of the tappets. 5 - H TWICE / W ONCE In this position the heating will come on and go off according to the times you have programmed (ON at A, OFF at B, ON at C, OFF at D). The Hot Water will come on at A and stay on until D. 6 - H OFF / W TWICE In this position the Heating will be permanently OFF and the Hot Water will come on and go off according to the times you have programmed (ON at A, OFF at B, ON at C, OFF at D). Note: If hot water is required all day with the heating shut off (i.e. heat off, water once) o Turn the selector switch to H twice / W once and turn down the room thermostat to its lowest setting. If constant hot water is required with heating off (i.e. heat off, water on) o Turn the selector switch to H on / W on and turn the room thermostat to its lowest setting. 9Using the programmer

10

11

Still having problems? Call your local heating engineer: Name: Tel: Visit our website: www.heating.danfoss.co.uk Email our technical department: ukheating.technical@danfoss.com Call our technical department 0845 121 7505 (8.45-5.00 Mon-Thurs, 8.45-4.30 Fri) For a large print version of these instructions please contact the Marketing Services Department on 0845 121 7400. Part No. 7485v03 06/08 Danfoss Ltd Ampthill Road Bedford MK42 9ER Tel: 01234 364621 Fax: 01234 219705