CE TYPE EXAMINATION CERTIFICATE

Similar documents
CE TYPE EXAMINATION CERTIFICATE

Analysis Report

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

Vescom bv Sint-Jozefstraat AV Deurne Nederland

Centexbel. General certification regulations. Construction products

MARKING EC Directive 97/23 PED (Pressure Equipment Directive)

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Analysis Report

ethekwini Electricity MV Switchgear flash over, and injury to staff member. Presentation to AMEU Technical Meeting Sept 2009.

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres?

Analysis Report

PPE Global Market Access Program

PRODUCT NUMBER: FlamePro1 JACKET

EC TYPE-EXAMINATION CERTIFICATE (EC Directive 89/686/EEC)

Valve Manufacturers Association of America

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Number K4126/06 Replaces K4126/05. Issued Dated Valid until Indefinite Page 1 of 6

SCOPE OF ACCREDITATION. High-visibility clothing EC type examination LST EN ISO 20471:2013. EC type examination LST EN ISO 11611:2008

EUROPUMP ATEX Guideline Part II

The Machinery Directive 2006/42/EC

Report VNLF Test Report

Flame retardant. Protectivewear fabrics by Klopman International

The European Radio Equipment Directive 2014/53/EU

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

CE marking of noise barriers and foundations

11/2016. Protective clothing BUSHFIRE. 3rd category of Personal Protective Clothing

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

The New PPE Regulation (EU) 2016/425

COMMISSION DELEGATED REGULATION (EU)

ISO INTERNATIONAL STANDARD

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

PRODUCT NUMBER: FirePro PARKA

Your Key to achieving C.E Marking Compliance

~~oeti. Report VN71 O Classification Report. Reference

Council Directive 93/68/EEC of 22 July 1993 amending Directives

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

PROTEK PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

Reaction to fire classification report No C

Being comfortable, warm and dry can make all the difference to your. DeLaval work and milker wear Quality wear for everyone, everywhere

The New EMC Directive 2004/108/EC

PRODUCT NUMBER: FirePro OVER-PANTS

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

1. Terms defined in the Construction Products Regulation (CPR)

Report VNNF Test Report

The PPE Directive and the PPE Regulation

The New EMC Directive 2004/108/EC

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

Contents. EN :2012 (E) Issue 5 ( ) Page

The transition requirements of the new Regulation (EU) 2016/425 of the European Parliament and of the Council on personal protective equipment

ILNAS-EN ISO :2017

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

Reaction to fire classification report No C-rev.1

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

DECLARATION OF PERFORMANCE. No EN

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

ISO INTERNATIONAL STANDARD

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Additional reaction to fire classification report No H

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Training, Assessment, Consultants for Hazardous & Industrial Areas

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

COMMISSION DELEGATED REGULATION (EU) /... of XXX

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

DECLARATION OF PERFORMANCE. No EN

actoolsupply.com YOUR SINGLE SOURCE FOR INDUSTRIAL ELECTRICAL PROTECTION actoolsupply.com

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Guidelines Cooperation between authorities under Articles 17 and 23 of Regulation (EU) No 909/2014

ISO INTERNATIONAL STANDARD

Excel User Guide for Data Gathering. Electrolux Chemical Management Web Application

Declaration of Performance

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

DECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

Webinar November 12, 2014

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 9

DECLARATION OF PERFORMANCE. No EN

Mandate M/118 WASTE WATER ENGINEERING PRODUCTS

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

COMMISSION DELEGATED REGULATION (EU) /... of

AS/NZS 4821:2014. Protective footwear for firefighters Requirements and test methods AS/NZS 4821:2014. Australian/New Zealand Standard

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Overview. Features & Benefits

GUIDELINES. the Interpretation of

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

ATEX/05/1/7. In detail:

Achieve Success with European Medical Device Commercialization. By Russ King

CE MARKING OF WOOD-BASED PANELS

Directive and standards of DHC-metering

8/2017. Firefighter protective clothing ANACONDA. 3rd category of Personal Protective Clothing

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Transcription:

In application of the directive 89/686/EEG of 21 December 1989 concerning the harmonisation of the Member States legislation relative to personal protective equipment, Centexbel Notified body 0493 authorised by decree AV/OA235/ST dated 94-05-25 of the Ministry of Employment and Labour has issued CE TYPE EXAMINATION CERTIFICATE Nr. 031/2015/1186 This CE Type examination certificate is valid until 16 Nov 2020 to: for: Van Puijenbroek Textiel, Goirle Bib and Brace trousers VP-18-BB combined with jacket VP-18-JS The personal protective equipment above mentioned satisfies the applicable essential safety requirements of the Directive. For the argumentation, the following standards are used: EN ISO 11612:2008 EN 1149-5:2008 IEC 61482-2:2009 EN ISO 11611:2007 EN 13034:2005+A1:2009 EN ISO 13688:2013 Protective clothing - clothing to protect against heat and flame Protective clothing - Electrostatic properties - Part 5: Material performance and design requirements Live working - Protective clothing agains the thermal hazards of an electric arc - Part 2: Requirements Protective clothing for use in welding and allied processes Protective clothing against liquid chemicals - Performance requirements for chemical protective clothing offering limited protective performance against liquid chemicals (Type 6 and Type PB[6]) Protective clothing - General requirements This is PPE of category III, subject to regular checks in accordance with article 11 of the European PPE directive. In agreement with the manufacturer s choice random checks shall be carried out to assess the quality of the final product (art.11a). The manufacturer must be able, on request, to present the test report of this quality control check. A first quality control check shall be performed at the latest on 31 Dec 2016 and at least be repeated with intervals of one year. This declaration applies to the equipment as submitted in the type testing and described in the manufacturer s technical file that is registered with number 7366. Issued by Centexbel, Notified Body 0493 (*), in Ghent, on 16 Nov 2015 Inge De Witte Certification Manager Attached: 1 Annex *) Recognized by decree AV/OA235/ST of 94-05-25 of the Ministry of Labor and Employment Technologiepark 7 BE 9052 Gent Belgium phone +32 9 220 41 51 fax +32 9 220 49 55 gent@centexbel.be www.centexbel.be

ANNEX Annex- cerficate 031/2015/1186 Page 1 of 4 CE TYPE EXAMINATION CERTIFICATE Nr. 031/2015/1186 1. Application Van Puijenbroek Textiel Postbus 11 5050 AA Goirle Nederland 2. Description EN 1149-5:2008 EN 13034:2005+A1:2009 Type6 EN ISO 11612:2008 A1 A2 B1 C1 D0 E1 F1

Annex- cerficate 031/2015/1186 Page 2 of 4 ENISO 11611:2007 A1+A2 Class 1 IEC61482-2:2009 ATPV 11.5cal/cm² Class 1

Annex- cerficate 031/2015/1186 Page 3 of 4 3. Materials and accessories Outer fabric D09328MM/D02287 D09339MQ/D02269 D1S246MM/D12246 D1S337MX/D12337 Reflective Tape FR263113 FR263115 FR263132 FR263140 Transfert FO263213: Plastic Window Hook and loop fastener open VEHFR/021 + VE25ZFR/021: Hook& Loop FR Zipper FO263046: Synthetic D-ring FO263224: Synthetic zipper puller FR263000: zipper MEGO FR263010: zipper KUBLO FR263019: zipper KUSPI Press button FD263014/15/16: FR Synthetic press button FD263042/43/44/45: Heavy metal Press button FD263055/56/57/58: light metal press button Seam 75%Cotton/25%Polyester 250g/m² with seam Garment D09328MM/D02287 garment D09339MQ/D02269 garment D1S246MM/D12246 garment D1S337MX/D12337 garment

Annex- cerficate 031/2015/1186 Page 4 of 4 Description/Picture of article The above picture is a general picture of the article. Possible variations of the above article can be present in the technical file. Note: Any modification in material, design, or other technical features must be brought to the attention of the Notified Body.