ECM Blower, All Hookups, WarmFlo ST/OT CFM Selection

Similar documents
Installation & Operating Instructions

A complete product line to fi t all your application needs GENERAL PRODUCT FEATURES

Installation & Operating Instructions

WARMFLO COMPATIBLE. Upflow. Number of Stages. This is a single package unit, it contains the WarmFlo II controller with a built-in WF- EZ3.

Dual Heat System. Universal Furnace Interface Module. Specially Equipped for 2-Speed HP. Controller Portion of Electro-Mate

ELECTRIC MAKE-UP AIR

Installation & Operating Instructions

WF-DFSLT Dual Fuel Kit

Providing Comfort Through Efficient Energy Solutions PRICE BOOK (USD) - LIST EFFECTIVE JUNE 1,

Installation & Operating Instructions

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

SERVICING S-15 CHECKING CAPACITOR

ELECTRO-BOILER. Midsize INSTALLATION & OPERATING INSTRUCTIONS

Field Application of Advanced Residential Air Conditioning Systems

Multiple Boilers Electro TS Series Application EB-C-STG5

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Troubleshooting the Indoor AHU as a Standard Product

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

B SERIES ELECTRIC FURNACE

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

E3EH-xxx-H Series E3EB-xxx-H Series

Installation & Operating Instructions

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

BASIC INSTALLATION AND OPERATION MANUAL

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

Installation Instructions

ELECTRO-BOILER Commercial Series

ELECTRO-BOILER. Commercial Series. INSTALLATION & OPERATING INSTRUCTIONS Model EB-C* Series

Your safety and the safety of others are very important.

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

Model 8120 and 8126 Safety & Installation Instructions

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SmartZone TM System Manual

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Installation Instructions

Industrial Series. Electric Hot Water Boiler EB-NB Series Installation & Operating Manual

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16)

L SERIES UNITS 505,191M. 4/2006 Supersedes 504,908M

TSTAT0201CW Recommended (sold separately)

36,000-62,000 BTUH Nominal Capacity

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

SYST0101CW Product Specifications

INSTALLATION INSTRUCTION

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

INSTALLATION INSTRUCTION

Installation Instructions

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Installation Guide.

Industrial Series. Electric Hot Water Boiler EB-NB Series Installation & Operating Manual

Operator: Save these instructions for future use!

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Models: 1F95U-42WF, ST75 Version: October Sensi TM. Touch Wi-Fi Thermostat MANUAL OPERATION GUIDE

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

AVPTC Multi-Position, Internal Txv

Variable Speed Convertible Air Handler 5 Ton

Model Number(s): WiFi Thermostats: 8840, 8830, 8820, 8810 Models Tested: 8820 rev 1.04

Indoor Unit (IDU) Installation & Operating Instructions Model: NC-FE-***

AVPTC Multi-Position, Internal Txv

JH Series Installation

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

Installation Instructions

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

Heat Pump Defrost Board Replacement Kit

Vertical Air Handler Unit

L SERIES UNITS 504,908M. 10/2004 Supersedes 9/2004

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

59MN7A Series 100 TROUBLESHOOTING GUIDE

Installation, Operation and Service Manual

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

Advanced Installation and Configuration Instructions

H32 Uni- Zone Model H32

Hydronic Air Handler Powered by Tankless Technology

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

Technical Data Manual Model Nos. and pricing: see Price List

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT

Troubleshooting Guide

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

RCS Residential Control Systems Inc.

AG Series Electric Heaters

Comfort Control 2 HD Thermostat

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Electro Industries Make-Up Air II

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT!

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Transcription:

Assumptions Electro-HELPS VIII ECM Blower, All Hookups, WarmFlo ST/OT CFM Selection 1. Typically the furnace will be setup for a top (Y2) speed relating to cooling requirement. Installer must determine whether the setup for cooling is adequate for the CFM required for the electric section, Electro-Mate. Example 2-ton AC only requires 800 CFM but 20 kw requires 1200 CFM. 2. The furnace bit switch setup may need to be sized for the kw heating instead of the cooling tons, see number 1 above. 3. The Brand X furnace or air handler has a Y1 and a Y2 speed. Y2 relates to the maximum speed (see numbers 1 and 2 above). Y1 typically is 20% to 30% less CFM. If the furnace only has a single Y, it must be assumed this is the highest CFM speed. 4. A furnace manufacturer s proper programming of the ECM motor provides a CFM rating to various terminal block input points, not RPM. The GE Series 2.3 motor, properly programmed, varies its RPM based on static pressure and loading. It makes every attempt to produce the CFM as setup. 5. Furnace terminal point G is typically 50% of full setup CFM. Therefore, the Electro-Mate or WarmFlo cannot be run with a G input only. 6. Certain manufacturers reduce the airflow approximately 10% during heating which is controlled by the furnace O terminal. The 2-speed WF-HP2 takes that into consideration. On other applications the installer may want to run the stat O to the furnace O and also to the outdoor O (to our knowledge, this only relates to manufacturers where reversing valve is high during cooling). 7. If furnace terminal BK is desired, use standard instructions provided with furnace and suggestions from their specified room thermostat or humidistat. 8. Gas furnace 2-stage or variable burner generally ties in with this wiring or field connection decision. See separate document Electro-Helps VII 2-Speed Equipment, Control Interface. Air Conditioning This Helps document reviews each Electro product with suggestions, connection drawings, etc. The first three provide only a single speed step-up when in heating or cooling. These relate specifically to single speed air conditioning equipment. See above Assumptions 1 and 2 relating to furnace bit switch setup and the comparison of cooling and heating sizing. 1. Electro-Mate, DFC type (EH001-1) a roomstat W or Y provides a non-feedback 24-volt to a furnace Y* terminal. Two field installed jumpers are required at the board upper right W to NO tab and board Y2 to NC tab. The BL tab goes to the furnace Y*. 2. HeatChoice (EI203 F2) basically identical to DFC. a. HeatChoice II (EI204 F12) effective manufacturing date 8-1-07, only a single wire from the right center Y tab directly to the furnace Y screw is required. See diagram on next page. 3. WarmFlo, WF-EM3 (HD319 F1) two field installed jumpers, the tabs are similar to DFC but AC-Y to NC tab and stat W to NO tab. The BL tab goes to furnace Y*. Note the stat G wire goes down to a G1 terminal and there is no wire under the EM3 stat G screw. 4. Electro-EZ-Mate (EH808) and WarmFlo Select SL1 (EH709) configuration mode switch is setup for AC. This board provides a direct terminal to terminal connection arrangement (Y is considered high speed). This latest WF+ board has provisions for a WarmFlo temperature sensing speed-up which typically can be associated with Y2. Drawing EH811 provides 4 hookup options. 1/12/2009 1 XC017

LED2 SW1 DFC Electro-Mate W Y2 R T1 W T2 STAT G T13 Y T11 Y2 T12 Y2 LED1 J1 OFF PEAK LED4 3 T10 T3 LED6 HL T4 HL T18 K2 K4 A/C K1 K3 T17 T16 T15 NO BL NC T20 COM T22 EL NO NC BL FURNACE "Y" CONDENSER T21 SB LED5 W1 F1 PWR ON K5 W2 T19 A 24 VAC T5 R T6 R UPCB5626 CS COM LED3 T9 T8 T14 T7 W G C C FAN CENTER C 02-18-03 EI203 F2 HeatChoice Figure 12 HeatChoice II 1/12/2009 2 XC017

1/12/2009 3 XC017

Heat Pump Single Speed This document reviews each Electro product with suggestions, connection drawings, etc. The first two provide only a single speed step-up when in heating or cooling. These relate specifically to single speed heat pump equipment. See above Assumptions relating to furnace bit switch setup and the comparison of cooling and heating sizing. 1. WarmFlo WF-EZ3 (HD319 F4 and HI320 p25) as shown, this only requires one jumper, T1 tab to NO tab. The BL tab goes to a furnace Y* terminal. a. Upgrade WF-EZ3 (HD319 and HI320 p25) board Rev B and after manufacturing date 9/17/07 add only a single wire connection between right tab BL and furnace Y screw. 2. WarmFlo WF-LGR3 (older) and HP-5043** (HD319 F4) same as WF-EZ3 prior to 9-17-07. 3. WarmFlo WF-LGR4 (HH341) for furnaces with single Y, as mentioned above, simply add the 5 th wire from terminal block Y to furnace Y. 4. Electro-EZ-Mate (EH811) and WarmFlo Select SL1 (EH709) configuration mode switch is setup for HP. This board provides a direct terminal to terminal connection arrangement. This latest WF+ board has provisions for a WarmFlo temperature sensing speed-up which typically can be associated with Y2. Drawing EH811 (previous page) provides 4 hookup options. Main WarmFlo II Board Options Using Internally Provided ST/OT Temperature Sensing Speed Functions Must be 5615B version board, manufactured after 6-04. Program chip version 2.35 and above, dated 5-10-05 and above, has a Spd A and Spd B output function. An ST and an OT temperature can be assigned to each. When the appropriate sensor passes through this set point, the Spd A or Spd B output is activated. Once the temperature detected point is active, the output continues to the end of that thermostat cycle. ST setup value when the ST sensor receives a temperature greater than this value, the appropriate speed output is active. OT setup value when the ST sensor receives a temperature less than this value, the appropriate speed output is active. The factory default: ST Spd A 96 ST Spd B 104 OT Spd A 50 OT Spd B 30 WarmFlo Analyzer, WF-ANZ*, after 4-05 has the last two screens available for changing these Spd A and Spd B set points. However, WF+ boards only allow speed B. WarmFlo PC software 4.00 dated 4-27-05 also has these functions. Drawing HH345 provides information to add EE-5053 relays with an Electro cable, WFCBSPD, for interface to furnace Y1 and/or Y2. This is standard with WF-HP2. 1/12/2009 4 XC017

1/12/2009 5 XC017

1/12/2009 6 XC017

Heat Pump, 2-Speed WarmFlo Select SL2 This model is designed for single control board interface with all 2-speed heat pump and ECM variable speed furnace requirements. It has provisions and setup arrangements for furnace Y and furnace Y2. See installation manual EI710 with hookup drawing EH710. Order EM-WU(WD)**-SL2 WF-HP2 the furnace speed relationship is the difference between cooling and heating. In cooling there is a direct function by function relationship and action between room thermostat, furnace, and heat pump unit. This is typically just as the heat pump manufacturer s normal arrangement. Y1 Y1 Y1 Y2 Y2 Y2 In heating the furnace Y1 and Y2 speeds are controlled by the WarmFlo sensor or dial switch position A. Dial switch position B provides immediate Y1 and dial switch position C provide immediate both Y1 and Y2 speeds. The following is the heating information directly from the WF-HP2 installation and setup manual, HI210B. Via factory defaults (changeable via WF-ANZ* or software downloads) there is a supply temperature setting for furnace Y1 and Y2, plus an OT temperature setting for furnace Y1 and Y2 (see bypass below). Factory defaults: ST, 96 and above Y1 ST, 104 and above Y2 OT, 50 and less Y1 OT, 30 and less Y2 In case of the ST, if the temperature rises above this preset value, the blower speed will increase. In the case of the OT, if the outdoor is below this temperature at the initial call for heat, the blower speed increase. Once this condition is crossed, it remains for the completion of the heat call cycle. This technique allows for maximum heat pump usage with minimum Electro-Mate/WarmFlo resistance. Note: If your furnace only has a Y1 or Y, WF-HP2 Y2 will not be used. Setup or installer temperature sensing bypass provisions are included for the installer to bypass the above temperature sensing/blower speed provision for direct heat call blower speed up condition. Approximately top center on the circuit board are two dial switches. The SOT TIME dial switch is detailed on page 12 (relates to cooling only and 4-wire stat). Above this is a dial switch marked A, B, C, D. The factory default is position B which provides heat call direct control of furnace Y1 and Y2 (1HEAT mode, stat Y1/2HEAT mode, stat Y2). If you desire to use WarmFlo temperature sensing to control the Y1 and Y2 blower speeds as described above, set the dial switch to A. If you desire an immediate heat call Y1 blower speed and allow WarmFlo temperature sensing to control Y2 as described above, set dial switch to C. 1/12/2009 7 XC017

WarmFlo Electric Furnace/Air Handler (assuming heat pump model HE-H-**) This product has all ECM variable blower motor features with speed selection setups and ST/OT Spd B temperature sensing override features. The Electro control board provides A, B, C, D pin jumper cooling speed selection and LO, MED, HI pin jumper heating speed selection. Thus you can match the cooling tons and the heating kw to its own speed arrangement. Also if the specific Electro electric furnace model has a WF II board with an ST and OT active sensor code chip, during the heating mode the Spd B function will override the heating setup pin jumper and force blower to full speed. Typically this has a higher factory default, suggest ST = 115 and OT = 30 F. Heat Minimal Blower Speed Selection On the right side is a peg jumper for a LO/MED/HI selection. The WarmFlo technology and action of both of the remote sensors will determine the full speed or maximum CFM when required by the heating system. This selection is simply a first step blower speed and does not necessarily have to match the kw capacity. The suggestions are as following, but 20 kw will function just fine with the LO position. 10 kw LO 765 CFM 15 kw MED 900 CFM 20 kw HI 1035 CFM Cool Minimal Blower Speed Selection At the control board right side is A/B/C/D selection. It is very important that this selection be matched to the cooling ton installed within the system. This is independent of the heating as outlined and setup above. A 3-3.5 ton 1200 CFM B 2.5-3 ton 1100 CFM C 2-2.5 ton 1000 CFM D 2 ton 900 CFM 1/12/2009 8 XC017