TERMOREGOLAZIONE THERMAL REGULATION

Similar documents
GUIDA TASCABILE POCKET GUIDE

IT 66 ESS IT 66 EWSS tavola 1 view 1 A

CP 70 E CP 70 EW tavola 1 view 1 B

CP 30 sc E CP 30 sc EW tavola 1 view 1 B

Accessori. Accessories

Hot Box 25/350-25/500

Mantellatura Body. Tav. 36. KP 175 Rev page 76

04/2015. Mod: CFG 202. Production code:

GENERATORI D ARIA CALDA PENSILI A COMBUSTIONE INDIRETTA INDIRECT COMBUSTION SUSPENDED SPACE HEATERS

Fonderie Sime S.p.A. - Via Garbo, Legnago (VR) - Tel Fax PLANET DEWY 30 BFR

SPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90

SPARE PARTS CATALOGUE CATALOGO PARTI DI RICAMBIO GAS BOILING PAN WITH INDIRECT HEATING 60 L PENTOLA GAS RISCALDAMENTO INDIRETTO 60 L

I-ONE 120 INU No Part Name Descrizione Wall Mounting Frame Dima di fissaggio GR Rear Case Fondo unità interna GR Evaporator Assy

B2009 compact. Dal 1901 COD

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

MURELLE ELITE HE T

displei studio baciocchi 2010

Fan heater Panther 6-15 Efficient fan heater for medium size premises

DEVIATING VALVES ART K063

Motor-driven condensing units MTE MTE R-410A

BLAST CHILLER/FREEZER 10GN 2/1 LENGTHWISE TOUCH LINE USA

Controllers for refrigeration EVBOX1

Ø24 Ø34 CP POLINI WITH KNOB CHOKE ELASTIC CONNECTION POLINI CP STARTER ARIA A POMELLO, ATTACCO ELASTICO

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

ESP 250 ELENCO ESPLOSI RICAMBI. INVOLUCRO / Shell assy. GRUPPO FRIGORIFERO / Cooling system. EVAPORATORE / Evaporator.

Controllers for refrigeration EVBOX1 data-logging extension

EDI 5. Control Box Wash Arm. Wash Pump Rinse Assembly Rinse Aid Injector Detergent Injector Detergent Pump Optional 2009 cod.

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

Section - A. Radiator Valves

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

CABINETS ECOSTORE SUPER PREMIUM

RICAMBI DOCCIA E IDRAULICI

Intellicomfort CH140GSM

SPARE PARTS CATALOGUE CATALOGO PARTI DI RICAMBIO

FORNO CONVEZIONE-VAPORE ELETTRICO 20GN1/1, 20GN2/1

CIMSA-FABAR. Warewashing equipment. Spare parts for: Suitable for:

3480/RCH SERIES INSTALLATION INSTRUCTIONS

SP GW...B. Ventilconvettori "Hydronic Global Cassette" "Hydronic Global Cassette" Fan Coil. Parti di ricambio / Spare parts

B2009 compact. Dal 1901 COD

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

CALDA VETRINA HEATED DISPLAY CABINETS BAGNOMARIA/ A SECCO DRY/BAIN-MARIE BAGNOMARIA BAIN-MARIE A SECCO VETRINA CALDA / HEATED DISPLAY CABINET DRY

INSTALLATION AND MANINTENANCE INSTRUCTIONS

TWO STAGE HEAVY OIL BURNERS

USER MANUAL and INSTALLATION MANUAL

Development of an advanced control system for chillers

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

Murelle HM 25 T. Cod /2013

USER and INSTALLATION MANUAL

Overload relays. General descriptions. Configuration of the front

ISO 9001: 2000 CERTIFIED COMPANY MURELLE HE 35 R (M) ENG. Fonderie SIME S.p.A Cod /2011

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

MICROCASA A LEVA 1GR. CARROZZERIA +VARIE CASING+VARIOUS. Italian Espresso Coffee Machines

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

ESP 2000 ELENCO ESPLOSI RICAMBI. INVOLUCRO / Shell assy. GRUPPO FRIGORIFERO / Cooling system. EVAPORATORE / Evaporator

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

We regulate and supply clean energy

RAUS air-cooled condensing units

Aquamatic Instantaneous DHW production unit with integrated storage tank

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Forced draught gas burner

LAVASTOVIGLIE SOTTOTAVOLO CON ADDOLCITORE UNDERCOUNTER DISHWASHER WITH WATER SOFTENER LS5 WS / WT4 WS

Indirect Fired Water Heater

The Benchmark Scheme

IST 03 C ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL

PRELIMINARY EDITION

Room thermostats for fan-coils, 3 speeds + automatic

Dati Tecnici Technical Data

Miscelatore monocomando lavello con canna girevole abbattibile. Single-control mixer for sink with swivel and knock-down spout.

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for MIWE

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

RS /E-EV C01 SERIES

NICE LINE. 1 Maniglie leggere ed eleganti, curate in tutti i dettagli. Finitura brillante, design attuale e assemblaggio accurato.

EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E

ATC ROC CC-131, CC-131R, CC-131C & CC-132, CC-132R, CC-132C

Wall hung boilers. Compact 29 A. Compact 29 A. Cod.E1042 Rev.12.0 (01/2019)

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

REVISIONE PROGRAM. N.

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

LOW NOx MODULATING GAS BURNERS

A Series Inertia Compressor Applications. Application Bulletin 115

Installation, operating and servicing instructions

REVISIONE PROGRAM. N.

linea mini catalog parts

AIR-CONDITIONER SERVICE MANUAL

PLANET -DIN PAGE 12-2 PAGE 12-6 PAGE 12-5

Stego accessories for cabinets

Thermostatic Radiator Valves (Caleffi)

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

TK-1001, 1101, 1201, 1301, 1601

Metering systems 0548EN April 2014

OWNER S MANUAL LOW-POWER SCREW-IN AND FLANGE-MOUNTED IMMERSION HEATERS (MAXIMUM 3 PINS)

GALATEA DOMUS. Dal 1901 COD

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Accessories. Safety Shut-off Valves. Certifications. Accessories. ASV375NT Safety Shut-off Valve. Combination Gas Control/Valve

Raffaello From serial number Group

SCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Transcription:

Termoregolazione /Thermal regulation Termoregolazione /Thermal regulation 31 TERMOREGOLAZIONE THERMAL REGULATION Termostati, Guaine, Regolatori tiraggio, Valvole di zona, Motori Thermostats, Sheaths, Draught regulators, Zone valves, Motors

32 Termoregolazione /Thermal regulation TA 3 Termostato ambiente meccanico, 3 contatti con spia. Temperatura regolabile 5/30 C Mechanical room thermostat with 3 contacts and warning light. Adjustable temperature 5 to 30 C TA 3l Con interrutore On-Off With On/Off switch 0412 TAC 3 Termostato a capillare di regolazione con sonda a dilatazione di liquido Capillary regulation thermostat with liquid expansion probe TAC 3 Fornito con manopola e ghiera. Temperatura regolabile 0/90 C. Capillare 1000mm. Bulbo Ø6,5x95 Quipped with handle and ring nut. Temperature range: 0 to 90 C. Length of capillary: 1000mm. Bulb: Ø 6.5x95 0423 TCR Termostato a capillare limitatore con riarmo manuale Capillary limit thermostat equipped with reset button TCR Capillare 1500mm. Bulbo Ø6,5x95. Temperatura sicurezza: 100 C Length of capillary: 1500mm. Bulb: Ø 6.5x95. Safety temperature: 100 C 0424 GN Guaina per termostati a capillare Sheath for capillary thermostats GN 7x120 Ø7x8x120 0425 GN 15/Sx120 Ø15x16x120 sagomata / shaped 0426 TC Termostato a contatto bimetallico, inscatolato. Con 3 contatti Contact bimetal thermostat, encased. Fitted with 3 contacts TC Temperatura regolabile 20/90 C. Con fascetta di fissaggio Temperature range: 20 to 90 C. Equipped with fixing band 0419

Termoregolazione /Thermal regulation 33 TIRM Termostato ad immersione limitatore con riarmo manuale, inscatolato. Conforme normative CE Immersion limit thermostat with reset button, encased. Complies with CE standards TIRM Temperatura sicurezza 100 C. Guaina 1/2 x100 Safety temperature: 100 C. 0421 TI Termostato ad immersione regolatore inscatolato. Conforme normative CE Immersion regulation thermostat, encased. Complies with CE standards TI Temperatura regolabile 0/90 C. Guaina 1/2 x100 Temperature range: 0 to 90 C. 0420 BIRM Termostato ad immersione doppio, regolatore e limitatore, con riarmo manuale. Conforme normative CE Immersion control/limit thermostat, with reset button. Complies with CE standards BIRM Temperatura regolabile 0/90 C. Temperatura sicurezza 100 C. Guaina 1/2 x100 Temperature range: 0 to 90 C. Safety temperature: 100 C. 0422 RET Regolatore di tiraggio per caldaie a legna e carbone, caldaie policombustibili e termocucine Draught regulator for wood and coal boilers, multifuel boilers, thermo cookers RET Apparecchio metallico con elemento termosensibile a cera. Campo di regolazione 30-100 C. Raccordo di montaggio conico sulla caldaia 3/4 Metal device with wax thermosensitive element. Temperature range 30 to 100 C. 3/4 cone shaped connection to the boiler 0590

34 Termoregolazione /Thermal regulation V2/S Valvola di zona a sfera 2 vie. Otturatore a sfera con passaggio totale. PN 10. Temperatura -20 +110 C Two-way ball valve. Ball plug for full flow section. Max pressure 10 bar. Temperature: -20 to +110 C V2/S 1/2 Ø 1/2. Con un attacco femmina e un attacco Ø 1/2. With female connection and male tailpiece 0509 V2/S 3/4 Ø 3/4. Con un attacco femmina e un attacco Ø 3/4. With female connection and male tailpiece 0510 V2/S 1 Ø 1. Con un attacco femmina e un attacco Ø 1. With female connection and male tailpiece 0511 V2/S 1 1/4 Ø 1 1/4. Con un attacco femmina e un attacco Ø 1. With female connection and male tailpiece 0512 V2/S 1 1/2 Ø 1 1/2. Ø 1 1/2. 0692 V2/S 2 Ø 2. Ø 2. 0693 V3/S Valvola di zona a sfera 3 vie. Otturatore a sfera a passaggio totale, per deviare il flusso dalla via centrale alle vie laterali. PN 10. Temperatura -20 +110 C Three-way ball valve. The full flow ball plug allows to divert the flow from the middle to the lines. Max pressure 10 bar. Temperature: -20 to +110 C V3/S 3/4 V3/S 1 V3/S 1 1/4 Ø 3/4 Ø 1 Ø 1 1/4. 0686 0687 0691

Termoregolazione /Thermal regulation 35 ZMK Motore per valvola di zona a sfera V2/S e V3/S. Con micro interno per attivazione di contatto ausiliario Motor for V2/S and V3/S ball valves. Micro switch triggers auxiliary contact ZMK 2/R Motore unidirezionale per valvola a 2 vie, alimentazione 230V-50Hz. Apertura e chiusura in 60. Con relè interno, viene azionato da termostato a 2 fili Unidirectional motor for 2 way valves, power supply 230V-50Hz. Opening and closing time 60 sec. With internal relay, it is driven by a 2 wire thermostat 0690N ZMK /3B Motore bidirezionale per valvola a 2 o 3 vie, alimentazione 230V-50Hz. Rotazione di 90 in 60. Con relè interno, viene azionato da termostato a 2 fili Bidirectional motor for 2 or 3 way valves, power supply 230V-50Hz. 90 rotation in 60 sec. With internal relay, it is driven by a 2 wire thermostat 0689N ZMK 20 Motore per valvola di zona a sfera V2/S (da 1 1/2 e 2 ). Con micro interno per attivazione di contatto ausiliario Motor for V2/S ball valves (1 1/2 and 2 ). Micro switch triggers auxiliary contact ZMK 20 Motore bidirezionale, alimentazione 230V-50Hz. Coppia 20Nm. Rotazione di 90 in 90. Con relè interno, viene azionato da termostato a 2 fili Bidirectional motor. Power supply 230V-50Hz. Torque 20Nm. 90 rotation in 90 sec. With internal relay, it is driven by a 2 wire thermostat 0695