TEC PELTIER TEC 30X30 4MM 2.5A x30 4. TEC PELTIER TEC 30X30 3.2MM 3.9A x30 3.

Similar documents
AC-162 Peltier-Thermoelectric Air Cooler

MicroSL Silicon Photomultiplier Detectors

The Art and Science of Being Cool

SEALED ENCLOSURE COOLING

AC-046 Peltier-Thermoelectric Air Cooler

Advantages / Characteristics

VAPOR SOLDERING DEVICE. RESEARCHER: ING. DO MAI LAM SUPERVISOR:Prof.Ing. IVAN UHLIR DrSc Ing. MARTIN NOVAK Ph.D.

International Engineering Research Journal Performance assessment of multistage thermoelectric cooling module based refrigerator

A Design of Thermoelectric Cooler and Optimization

Development and Testing of Hot Cold Tumbler Operating on Peltier Effect

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

Hotplates, Magnetic Stirrers and Stirring Hotplates

DESIGN, ANALYSIS AND FABRICATION OF THERMOELECTRIC COOLING AND HEATING SYSTEM FOR WATER DISPENSER

Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT A. P.O. Box Industry Road Hatfield, PA 19440

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT

Review on Thermo-electric cooling for Atmospheric water extraction

IEC THE PROMISE THE PROOF HEATEX INDIRECT EVAPORATIVE COOLING AIR-TO-AIR HEAT EXCHANGERS

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

A Chiller is equipment to control temperature of customers heating sources. Application Examples

Certificate of Compliance

Safe Enclosure Cooling

Cooled Butterfly 980nm Pump Laser Module

Product Brochure. RF/Microwave Manufacturing Services


COMPRESSOR LESS SOLAR REFRIGERATOR

TC-PLUS Thermal Cyclers

TORREY PINES SCIENTIFIC, INC.

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

Ultra low temperature freezers. -40 C and -86 C. Green Line

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

LAUDA ECO. Precise, economical, flexible

GAS FREE REFRIGERATOR USING PELTIER MODULE

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

COOLING OF BIKER S HELMET USING PELTIER MODULE

Thermal Electronics Corp. Service & Parts Manual. Rev.1 07

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP

BIOMEDICAL REFRIGERATORS

Integration of electronic system with electrothermally cooled IR detector: thermal analysis

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

COMPARISON OF THE EXPERIMENTAL PERFORMANCE OF A THERMOELECTRIC REFRIGERATOR WITH A VAPOUR COMPRESSION REFRIGERATOR

Fabrication of A Prototype for Condensation of Water on Metal Surface Using Peltier Modules

Manufacturer since

Silicone Rubber Enclosure Heaters

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

Thermoelectric Bath. Series HEB

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

HEB Series. Peltier-Type Thermoelectric Bath

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

MD-MINI Dry Bath. Instruction Manual

Thermoelectric Bath. Series HEB

RF Admittance Technology FACTS

XIAMEN NORINT INDUSTRIAL CO., LTD. RIPS NEW MATERIAL TECH CO., LTD.

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

2018 Midstream Lighting Product Catalog

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Solar Refrigeration using Peltier Module Uttam Kumar Chaudhary 1, Adarsh patel 2, Deepak Arya 3, Deepanshu Gautam 4, Prasoon Choudhary 5

Technical Data Sheet 3mm Phototransistor T-1

INDUSTRIAL APPLICATIONS THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

HEB Series. Thermoelectric Bath

Proximity Sensor Components

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

International Journal of Engineering Science Invention Research & Development; Vol. V, Issue VI, DECEMBER E-ISSN:

XPIN -XT X-ray Detector Operation Manual

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

CR A-F-A-E-HQQE 3x400/ HZ

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

CR20-07 A-F-A-E-HQQE 3x400/ HZ

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Technical Data Sheet 5mm Phototransistor T-1

Low Cost Heat Pump Water Heaters

OTC, OTM and OTI Series Options

RIGID DC LIQUID CHILLER

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Code 542 Peltier Rack User's Guide

Certificate of Compliance

Keywords: Thermo-Electric Module, Peltier Effect, Solar Energy, Solar Cells, Coefficient of Performance.

Project Name. Date. Cat. Number. Type

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

Journal of Environmental Research And Development Vol. 6 No. 4, April-June 2012

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

TP /4-A-F-A-BQQE 400D 50HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets

CLI Refrigerant Gas Leak Detector. User s Guide

Transcription:

TEC Series Wakefield-Vette s Peltier, thermoelectric coolers can meet the requirement of higher current and large cooling. It is often applied to experimental, scientific and biomedical instruments, laboratory equipment, industry and electrical equipment and consumables. The ambient temperature can arrive 100C, long-term working temperature is recommended to be below 90C. Features: All products are RoHS and REACH compliant, SGS ISO9001 verified Thermoelectric module material are UL certification Standard Wire is 150mm Thermoelectric module moisture protection standard is sealed by white RTV silicone, but also support select other moisture protection style, Such as translucent silicone, black epoxy. Thermoelectric module flatness tolerance support select 0.2mm, 0.13mm, 0.1mm. WKV Part Number Description Current Q max (W) V max (V) @ max (A) @ 27 C 27 C T max ( C) @ 27 C # of Couples Outline (L/W/) Height (mm) TEC-30-40-127 PELTIER TEC 30X30 4MM 2.5A 2.5 21.4 15.4 68 127 30x30 4 TEC-30-32-127 PELTIER TEC 30X30 3.2MM 3.9A 3.9 33.4 15.4 68 127 30x30 3.2 TEC-40-47-127 PELTIER TEC 40X40 4.7MM 3.9A 3.9 33.4 15.4 69 127 40x40 4.7 TEC-40-33-127 PELTIER TEC 40X40 3.3MM 8.5A 8.5 72 15.4 69 127 40x40 3.3 TEC-30-36-127 PELTIER TEC 30X30 3.6MM 3.0A 3.0 25.7 15.4 68 127 30x30 3.6 TEC-30-47-71 PELTIER TEC 30X30 4.7MM 3.9A 3.9 18.7 8.6 69 71 30x30 4.7 TEC-30-38-71 PELTIER TEC 30X30 3.8MM 6.0A 6.0 28.7 8.6 69 71 30x30 3.8 TEC-40-38-127 PELTIER TEC 40X40 3.8MM 6.0A 6.0 51.4 15.4 69 127 40x40 3.8 TEC-20-33-31 PELTIER TEC 20X20 3.3MM 8.5A 8.5 16.8 3.75 69 31 20x20 3.3 TEC-30-33-71 PELTIER TEC 30X30 3.3MM 8.5A 8.5 72 15.4 69 71 30x30 3.3

TEC-40-47-127 1/2

TEC-40-47-127 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-30-32-127 1/2

TEC-30-32-127 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-30-40-127 1/2

TEC-30-40-127 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-40-33-127 1/2

TEC-40-33-127 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-30-36-127 1/2

TEC-30-36-127 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-30-47-71 1/2

TEC-30-47-71 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-30-38-71 1/2

TEC-30-38-71 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-40-38-127 1/2

TEC-40-38-127 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-20-33-31 1/2

TEC-20-33-31 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2

TEC-30-33-71 1/2

TEC-30-33-71 Operation Tips: Maximum Operating Temperature: 90 o C Do not exceed Imax or Vmax when operating module Please consult Wakefield-Vette for moisture and corrosion protection options as well as specific application inquiries 2/2