Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q

Similar documents
Documentation. Parallel Heating Cable. Type: ELP

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Heating Mats and Jackets. innovations in heat tracing

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

Consignes d installation

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

GENERAL SPECIFICATION ELECTRICAL

DESIGN GUIDELINES. THERMAL building SOLUTIONS

SELF-REGULATING PIPE TRACING HEATER CABLE

F1202 TRACE HEATING. Road & Ramp

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

AKOCABLE Heating Cable Solutions Electrical Tracing

Snow melting for ramps, access ways, and footpaths

AKOCable Heating Cable Solutions Electrical Tracing

Electrically Heated Sample Lines Type 3/4/5-N/M/H (Ex), PSP 4M(-W), Type 3/4/5-5/30/50/80/100/120 (Ex)

KE-Series Constant-Wattage Heating Cable

Self Regulating Trace Heating Systems Installation and Maintenance. Non-Hazardous Area Installations

Instruction Manual ET0002 / Version 1.0. Heating Tape

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing

HEATRACE. Young Chang Silicone Ltd, Co. SELF-REGULATING PIPE TRACING HEATER CABLE. Installation, Operation & Maintenance Manual

First Trace Heating Product Details

Temperature Sensor TRG Original Installation Instructions English

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Domestic Hot Water Application manual

Installation and Operation. Installation systems for pipes EKL/EMK

Data Sheet. Self regulating process heating tapes RS stock numbers ,

Uponor Comfort E AL-Foil Mat

Design Guide and Installation Details for Self-Regulating Heating Cable

C Electrical Connection Kit

Installation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com

Traction Cable Radox 3 GKW

Royden. Look how easy it is to roll out the heat

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

Drexan Energy Systems Inc.

Installation & Maintenance

Frost Heave Protection System Installation and Operation Manual

Technical Data. General specifications. Rated operating distance s n 5 mm

Fire Sprinkler Freeze Protection Design / Install Guide

CIR Carbon Infrared Emitter. Operating instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Heating Cables and Tapes. Technology. Constant wattage tapes

Technical Databook for Industrial Heat-Tracing Systems 2006/2007

Heaters for. Hot Runner Systems. COIL Heaters l MICRO TUBULAR COIL Heaters l. The first choice, to last...

NELSON HEAT TRACING SYSTEMS INSTALLATION

UNDERWOOD HEATING SYSTEM

High Performance LSZH Fire Resistant Cable

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

NELSON HEAT TRACING SYSTEMS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

OPTIBAR P 1010/2010 C Supplementary instructions

Data Sheet. Self regulating heating tapes. RS stock numbers

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Electrical Safety Requirements

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Principle of Operation:

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

NELSON HEAT TRACING SYSTEMS

Technical Data. Dimensions

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

ELECTRIC HEATING THERMOSYSTEM

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

0.4 In the preparation of this standard, assistance has been derived from the following standards:

Genie Heated Regulator Installation & Operation Instructions

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

Type approval qualification of Photovoltaic Modules Procedures and test experiences

Operating instructions

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

OPTIBAR DP 7060 Supplementary Instructions

DOMOTHERM CLASSIC TWIN/S MAT

Screw-in heater (EHK)

DHCSR Series Drum / Pail Heaters

Energy Saving Band Heaters

National Electrical Code

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Parallel Heating Cables Standard types... 24

WATLOW ELECTRIC MANUFACTURING COMPANY Installation & Maintenance Manual for ECO-HEAT Heaters I&M MANUAL No: Page: 1 Date: 3/15/2017 Rev: 4

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

Carbon Film Installation Instructions

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

FIRE RESISTANT CABLES FP300

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

STARBOX - CONDENSER UNITS

Single core cables with reduced wall thickness

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Toll Free:

Survey of electrical equipment installed in hazardous areas on tankers

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

Technical Databook for Industrial Heating Systems

EasyWire Between Joists Installation Instructions

SECTION ISOLATED POWER SYSTEMS

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Transcription:

Documentation Glass -/quartz insulated Heating Cable Factory terminated Type: ELK-H, -HS, -Q ELW-H, -HS, -Q 05.01.2018 K. Folkerts

Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts

1 05.01.2018 K. Folkerts

Heating Cable for Maximum Flexibility The factory terminated heating cable ELK-H is suitable for trace heating of apparatus, appliances and systems in a dry environment with protected installation. Both the high output and the slight, flexible design provide a wide variety of applications for this heating cable. Advantages: Factory terminated Can be used for high temperatures Ready to be used instantly Highly flexible Small bending radius Easy to assemble Applications: Heat tracing on apparatus, appliances and systems Glass devices and systems with high output needs Laboratory applications Type ELK-H up to 450 C 1.32 Heating Cables / Heating Tapes

Technical Information Type ELK-H up to 450 C Data Insulation E-glass textile Nominal voltage 230 V Output Approx. 125 W/m* Operating temp., max. 450 C Diameter 3.5-4.5 mm Bending radius, flat, min. 8 mm Installation temp., min. Not restricted Moisture proof No Cold lead length 1.2 m, without plug Protection class Depending on installation Standards Manufactured according to Final inspection according to DIN VDE 0721 T2 DIN VDE 0721 T2 1.5 kv AC 1 min *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. Designation Heated length (m) Nominal output (W) Art. No. ELK-H-0.5 0.5 60 0140002 ELK-H-1.0 1.0 126 0140005 ELK-H-1.4 1.4 180 0140008 ELK-H-2.0 2.0 250 0140013 ELK-H-3.0 3.0 375 0140014 ELK-H-4.0 4.0 490 0140019 Designation Heated length (m) Nominal output (W) Art. No. ELK-H-5.0 5.0 622 0140020 ELK-H-6.5 6.5 768 0140024 ELK-H-8.0 8.0 987 0140025 ELK-H-10.0 10.0 1260 0140030 ELK-H-12.6 12.6 1555 0140031 ELK-H-16.0 16.0 1945 0140034 Not all resistances are available ex stock please contact us. Other lengths upon request. Resistance tolerance: +/- 5 % Lengths tolerance ± 2%, max. ± 0.25 m. Cables shall neither intersect nor contact. Provide protection by means of circuit breaker FI 30mA. Please observe the standards EN 60519-1, EN 60519-2. www.eltherm.com 1.33

Heating Cable Robust, for Higher Temperatures This factory terminated heating cable is ideally suited for trace heating of apparatus, appliances and systems in a dry environment. Preferably used for appliances and systems with high output requirements. Small dimensions and high flexibility simplify the assembly. The outer braiding provides protection against mechanical damages and can be integrated in the electrical protection measures. Advantages: Factory terminated Increased safety through protective braid High output Ready to be used instantly Highly flexible Can be used for higher temperatures Small bending radius Easy to assemble Applications: Heat tracing on apparatus, appliances and systems Devices and systems with high output needs Laboratory applications Type ELK-HS up to 450 C 1.34 Heating Cables / Heating Tapes

Technical Information Type ELK-HS up to 450 C Data Insulation E-glass textile Protective braid 1.4301 / SS 304 Nominal voltage 230 V Output Approx. 125 W/m* Operating temp., max. 450 C Diameter 4.5 mm Bending radius, min. 8 mm Installation temp., min. Not restricted Moisture proof No Cold lead length 1.2 m, without plug Protection class I Standards Manufactured according to Final inspection according to DIN VDE 0721 T2 DIN VDE 0721 T2 1.5 kv AC 1 min *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. Designation Heated length (m) Nominal output (W) Art. No. ELK-HS-0.5 0.5 60 0140102 ELK-HS-1.0 1.0 126 0140105 ELK-HS-1.4 1.4 180 0140108 ELK-HS-2.0 2.0 250 0140113 ELK-HS-3.0 3.0 375 0140114 ELK-HS-4.0 4.0 490 0140119 Designation Heated length (m) Nominal output (W) Art. No. ELK-HS-5.0 5.0 622 0140120 ELK-HS-6.5 6.5 768 0140124 ELK-HS-8.0 8.0 987 0140125 ELK-HS-10.0 10.0 1260 0140131 ELK-HS-12.6 12.6 1555 0140134 ELK-HS-16.0 16.0 1945 0140137 Not all resistances are available ex stock please contact us. Other lengths upon request. Resistance tolerance: +/- 5 % Lengths tolerance ± 2%, max. ± 0.25 m. Cables shall neither intersect nor contact. Provide protection by means of circuit breaker FI 30. Please observe the standards IEC 62395-2, EN 60519-10. www.eltherm.com 1.35

Heating Cable for Highest Output The preferred use of the heating cable is for glass, quartz or ceramic devices and systems with the highest output requirements in a dry environment. Small dimensions and high flexibility simplify assembly. The heating cable must be installed touch-protected. If you plan to use the heating cable on metal and at an operating temperature in excess of 650 C, please consult our project engineers. Advantages: Factory terminated Highest output Highest operating temperatures Ready to be used instantly Highly flexible Small bending radius Surface-friendly Applications: Heat tracing on glass, quartz and ceramic devices Devices and systems with high output needs Laboratory & research applications Type ELK-Q up to 900 C 1.40 Heating Cables / Heating Tapes

Technical Information Type ELK-Q up to 900 C Data Insulation Quartz textile Nominal voltage 230 V Output ~ 175 W/m* Operating temp., max. 900 C Diameter Approx. 4 mm Bending radius, min. 5 x outer diameter Installation temp., min. Not restricted Moisture proof No Cold lead length 1.2 m, without plug Protection class Depending on installation Standards Manufactured according to Final inspection according to DIN VDE 0721 T2 DIN VDE 0721 T2 1.5 kv AC 1 min *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. Designation Heated length (m) Nominal output (W) Art. No. ELK-Q 0.6 0.6 106 0160003 ELK-Q 1.0 1.2 138 0160006 ELK-Q 1.4 1.4 270 0160007 ELK-Q 2.0 2.0 319 0160011 ELK-Q 3.1 3.1 533 0160014 Designation Heated length (m) Nominal output (W) Art. No. ELK-Q 4.0 4.0 696 0160017 ELK-Q 5.0 5.0 882 0160020 ELK-Q 6.0 6.0 1062 0160023 ELK-Q 8.0 8.0 1438 0160026 ELK-Q 10.0 10.0 1653 0160029 Not all resistances are available ex stock please contact us. Other lengths upon request. Resistance tolerance: +/- 5 % Lengths tolerance ± 2%, max. ± 0.25 m. Cables shall neither intersect nor contact. Provide protection by means of circuit breaker FI 30. Please observe the standards IEC 62395-2, EN 60519-10. All articles including termination instruction. www.eltherm.com 1.41

Heating Tape for Maximum Flexibility It is used to heat up glass, quartz or ceramic devices and systems in a non-corrosive and dry environment. The tape is highly flexible, does not damage the surfaces and is suitable for high output requirements. The heating tape should be protected mechanically and adjacent metallic parts should be integrated in the electrical protection measures. Advantages: Factory terminated Ready to be used instantly Single end connection Can be used for high temperatures Highly flexible Surface-friendly Small bending radius Easy to assemble Applications: Heat tracing on apparatus, appliances and systems made of glass, quartz or ceramic material Glass devices and systems with high output needs Laboratory & research applications Type ELW-H up to 450 C 1.36 Heating Cables / Heating Tapes

Technical Information Type ELW-H up to 450 C Data Standards Insulation (1) Outer jacket (2) Nominal voltage Output E-glass textile E-glass textile 230 V Approx. 250 W/m* Manufactured according to Final inspection according to DIN VDE 0721 T2 DIN VDE 0721 T411 1.5 kv AC 1 min Operating temp., max. 450 C Dimensions 30 x 5 mm Bending radius, flat, min. 10 mm Installation temp., min. Not restricted Moisture proof No Connection Protection class 1.2 m, without plug Depending on installation 1 2 *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. Designation Heated length (m) Nominal output (W) Art. No. ELW-H-0.50 0.50 126 0240002 ELW-H-0.70 0.70 180 0240005 ELW-H-1.00 1.00 250 0240010 ELW-H-1.50 1.50 375 0240011 ELW-H-2.00 2.00 490 0240016 ELW-H-2.50 2.50 622 0240017 Designation Heated length (m) Nominal output (W) Art. No. ELW-H-3.25 3.25 768 0240021 ELW-H-4.00 4.00 987 0240025 ELW-H-5.00 5.00 1260 0240027 ELW-H-6.30 6.30 1555 0240031 ELW-H-8.00 8.00 1945 0240034 Not all resistances are available ex stock please contact us. Other lengths upon request. Resistance tolerance: +/- 5 % Lengths tolerance ± 2%, max. ± 0,25 m. Cables shall neither intersect nor contact. Provide protection by means of circuit breaker FI 30mA. Please observe the standards EN 60519-1, EN 60519-2. www.eltherm.com 1.37

Heating Tape Robust, for Higher Temperatures This factory terminated heating cable is ideally suited for trace heating of apparatus, appliances and systems in a non-corrosive and dry environment. The heating tape is highly flexible, does not damage the surfaces and is suitable four high output requirements. The braiding provides protection against mechanical damages and can be integrated in the electrical protection measures. Advantages: Factory terminated Ready to be used instantly Single end connection Increased safety through protective braid Can be used for higher temperatures Highly flexible Surface-friendly Small bending radius Easy to assemble Applications: Heat tracing on apparatus, piping, valves and systems Devices and systems with high output needs Laboratory & research applications Type ELW-HS up to 450 C 1.38 Heating Cables / Heating Tapes

Technical Information Type ELW-HS up to 450 C Data Standards Insulation (1) E-glass textile Protective braid (2) 1.4301 / SS 304 Outer jacket (3) Nominal voltage E-glass textile 230 V Manufactured according to Final inspection according to DIN VDE 0721 T2 DIN VDE 0721 T411 1.5 kv AC 1 min Output Approx. 250 W/m* Operating temp., max. 450 C Dimensions 30 x 5 mm Bending radius, flat, min. 10 mm Installation temp., min. Not restricted Moisture proof Cold lead length, both ends No 1.2 m, without plug 1 2 3 Protection class I *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. Designation Heated length (m) Nominal output (W) Art. No. ELW-HS-0.5 0.50 126 0240102 ELW-HS-0.7 0.70 180 0240105 ELW-HS-1.0 1.00 250 0240110 ELW-HS-1.5 1.50 375 0240111 ELW-HS-2.0 2.00 490 0240116 ELW-HS-2.5 2.50 622 0240117 Designation Heated length (m) Nominal output (W) Art. No. ELW-HS-3.25 3.25 768 0240121 ELW-HS-4.0 4.00 987 0240125 ELW-HS-5.0 5.00 1260 0240127 ELW-HS-6.3 6.30 1555 0240131 ELW-HS-8.0 8.00 1945 0240135 Not all resistances are available ex stock please contact us. Other lengths upon request. Resistance tolerance: +/- 5 % Lengths tolerance ± 2%, max. ± 0,.25 m. Cables shall neither intersect nor contact. Provide protection by means of circuit breaker FI 30. Please observe the standards IEC 62395-2, EN 60519-10. www.eltherm.com 1.39

Heating Tape for Highest Output The preferred use of the heating cable is for glass, quartz or ceramic devices and systems with the highest output requirements in a dry environment. Single end connection and high flexibility simplify assembly. The heating tape must be installed touch-protected. If you plan to use the heating cable on metal and at an operating temperature in excess of 650 C, please consult our project engineers. Advantages: Factory terminated Highest output Highest operating temperatures Ready to be used instantly Highly flexible Small bending radius Surface-friendly Single end connection Applications: Heat tracing on glass, quartz and ceramic devices Devices and systems with highest output needs Laboratory & research applications Type ELW-Q up to 900 C 1.42 Heating Cables / Heating Tapes

Technical Information Type ELW-Q up to 900 C Data Standards Insulation (1) Outer jacket (2) Nominal voltage Output Quartz textile Quartz textile 230 V 350 W/m* Manufactured according to Final inspection according to DIN VDE 0721 T2 DIN VDE 0721 T2 1.5 kv AC 1 min Operating temp., max. 900 C Dimensions (wxh) Approx. 35 x 6 mm Bending radius, flat, min. 20 mm Installation temp., min. Not restricted Moisture proof No Cold lead length 1.2 m, without plug 1 2 *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. Designation Heated length (m) Nominal output (W) Art. No. ELW-Q 0.6 0.60 138 0260003 ELW-Q 0.7 0.70 270 0260005 ELW-Q 1.0 1.00 319 0260008 ELW-Q 1.5 1.55 533 0260012 ELW-Q 2.0 2.00 696 0260014 Designation Heated length (m) Nominal output (W) Art. No. ELW-Q 2.5 2.50 882 0260017 ELW-Q 3.0 3.00 1062 0260020 ELW-Q 4.0 4.00 1438 0260023 ELW-Q 5.0 5.00 1653 0260026 Not all resistances are available ex stock please contact us. Other lengths upon request. Resistance tolerance: +/- 5 % Lengths tolerance ± 2%, max. ± 0.25 m. Cables shall neither intersect nor contact. Provide protection by means of circuit breaker FI 30. Please observe the standards IEC 62395-2, EN 60519-10. www.eltherm.com 1.43

2 05.01.2018 K. Folkerts

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com QAA - 025 Installation of glass- or quartz-insulated Heating Cables/Tapes 0. Applications Glas/quartz insulated series trace heaters are suitable for use on tanks, pipes and pipe attachments like valves, pumps etc. in non hasardous areas in laboratory and commercial environments. 1. Receipt of Goods Upon receipt of the goods, check the heater and the accessories and compare with the data on the delivery-note to ensure that the correct material was supplied. 2. Storage The goods have to be stored in a dry place at an ambient temperature of -20 > +60 C. Avoid sharp bends and kinks in order not to break the heating conductor. 3. Length of Heating Circuit The lengths are calculated by eltherm. For shortening or elongation, please contact eltherm. 4. Protective Measures - glass- or quartz-insulated trace heaters are not moisture protected and must be operated in dry areas only. Use in hasardous areas is not possible - Design and installation of heating circuits is to be made compliant to the standards EN 60519-1, -2 and EN 62395-2 as well as to any other locally applicable codes and standards - Series trace heaters should be operated with a controller. A controlled or stabilised mode of operation as per EN 62395-2 is to be implemented - Suitable positioning of the temperature sensors will avoid overheating of pipeline / tank, medium and trace heater. Make sure the sensors are properly attached. - Use of a RCD with a tripping level of max. 30 ma above the inherent leakage current level is recommended for each heating circuit. - When using the trace heaters on metallic surface, this surface also has to be integrat ed in the leakage current protection acc. to DIN VDE 100, part 410 before operation of the system. QAA-025-eng.DOC Revision: 3 page 1 of 5

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com QAA - 025 Installation of glass- or quartz-insulated Heating Cables/Tapes - When using trace heaters with integral protective braid, this has to be earthed. In case of heaters without protective braidt, the installed heaters must be covered by a metallic layer. This metallic layer (e.g. cladding of the thermal insulation) has to be earthed. - Prior to installation work or maintenance, the relevant heaters need to be disconnected from power supply. If required, heated surfaces need to cool down to become accessible. 5. Installation Instructions - Installation is to be done by personnel that has been trained for installation of trace heaters - Heaters and sensors need to be placed on the designated pipes / tanks in the planned positions in order to avoid overheating of equipment as well as insufficient temperature maintenance - The max. operating temperature of the heated device as defined by the plant owner as well as the maximum trace heater temperatures (max. 450 C powered, 500 C unpowered in case of ELK-H; max. 800 C powered, 1000 C unpowered in case of ELK-Q) must not be exceeded. This may be achieved by use of an appropriate temperature control. - Remove any sharp objects from the surface to be heated; clean and degrease the surface - Mark the heater spacing on the surface of the device to be heated - For heaters with bilateral supply: Arrange both cable ends next to each other - in case of two dimensional applications: apply the trace heater onto the surface with adhesive tape (approx. every 300 mm). Max. operating temp. of the adhesive tape must not be lower than the maintenance temperature (or the process temperature, whichever is higher) - on metallic pipes: place the trace heater on the pipe surface along the pipe axis. Spiral glass tape (non adhesive) around pipe and heater, so that it fixes the heater approx. every 300 mm - on glass or ceramic pipes: if required, the trace heater may also be installed in a spiral pattern QAA-025-eng.DOC Revision: 3 page 2 of 5

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com QAA - 025 Installation of glass- or quartz-insulated Heating Cables/Tapes - Take care that the trace heater is not twisted, that the heating elements do not touch nor cross, as it might otherwise lead to local overheating and destruction of the heating elements. Min. bending radius: 5 mm; heating tapes to be bent over the wide side - Attach heater to pumps, valves and other components in such way that those compo nents are accessible for maintenance or exchange without major mechanical stress for the heater - Make sure the heater has a good contact to the surface to be heated. In case of gaps, fill those with thermally conductive and temperature resistant materials. - The heater should be fully covered (the entire length) with aluminum foil in order to prevent insulation material from slipping between the cable and surface to be heated. - If thermal insulation with metallic cladding is used, provide an insulation entry kit to pro tect the supply lead or heating tape against cuts - Electrically heated parts have to be identified in reasonable distances with warning labels Electrical Heating on the thermal insulation (approx. 5 m distance between each label on pipelines or at least 1 warning label per pipe-branch respectively). QAA-025-eng.DOC Revision: 3 page 3 of 5

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com 6. Testing QAA - 025 Installation of glass- or quartz-insulated Heating Cables/Tapes After the completion of a heating circuit and prior to the installation of the thermal insulation, the following steps have to be taken: - visual check of the heating cable/tape regarding possible mechanical damages and check whether the installation instructions have been followed. - test of the insulation resistance: * the insulation resistance of each heating-circuit is measured between each single bus wire and the metal sheath (protective braid) and is to be recorded. * test-voltage: min. 500 Volt, max. 1000 Volt * irrespective of the heating-circuit length, the isolation resistance must not be lower than 10MOhm. - in case of lower isolation resistance, the source of the defect has to be determined and removed. - functional check of the heating circuit (special attention is to be given to heater temperature to avoid any overheating during the performance of this test) - repeat the tests after the thermal insulation has been applied. - Identification: All relevant technical data are given on tag. Make sure tag is in place and information is legible QAA-025-eng.DOC Revision: 3 page 4 of 5

eltherm GmbH Ernst-Heinkel-Straße 6-10 57299 Burbach, Germany Fon: +49 (0) 27 36 / 44 13-0 Fax: +49 (0) 27 36 / 44 13-50 E-Mail: info@eltherm.com Internet: www.eltherm.com QAA - 025 Installation of glass- or quartz-insulated Heating Cables/Tapes 7. Operation and Maintenance - During operation of the system, local laws and regulations for the use of electrical trace heaters in hazardous areas as well as all other applicable standards and safety regula tions are to be followed - The permissible operating conditions as stated on the label,(i.e. voltage, amperage, exposure temp., operating temp., IP protection classification) are to be followed accordingly - When put into operation the first time, lubricant may evaporate from the glass cloth. The vapours are non-toxic but may activate smoke alarms. The colour change of the glass cloth that may be caused by the vapours does not effect the heating and is thus not a warranty issue. - After long heating intervals, the heating cable/tape becomes more rigid due to the loss of lubricant. Avoid narrow bends and treat the heater carefully in order not to break it. - Trace heaters ELK / ELQ are generally maintenance free, although it is recommended that the heating be checked by qualified personnel in regular intervals for damages and insulation resistance. - Lids and cable entries of junction boxes, thermostats splices etc. to which trace heaters are connected need to be closed and sealed as per manufacturers instruct tions. - The opening of controllers, junction boxes and terminations is permitted only when the heating system is not energised - Installed trace heater has to be protected against damages that may occur during repair work on heated components - After completion of the repair, the heating circuit will once again need to be tested as shown in paragraph 6 Testing - Damaged heating circuits shall not be operated. This is the case when: * heater or attached leads show damage or deformation * the circuit is electrically defective (open circuit, high leakage current) * after thermal or mechanical overstress * after failure of temperature controls * after damage to the workpiece to which the heater is installed - Temperature control units and control devices are to be checked at least annually by trained workers or authorized persons QAA-025-eng.DOC Revision: 3 page 5 of 5

3 05.01.2018 K. Folkerts