Calm. Service Instructions

Similar documents
Aero. Service Instructions

Wind. Service instruction

Turbo. Service Instructions

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

AXIAL FANS user's manual. model Quiet

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

AXIAL FANS USER S MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

INTELLIGENT AXIAL FAN user's manual

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

CENTRIFUGAL FANS user's manual. model VENTS VK.

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

HEAT RECOVERY AIR HANDLING UNIT

Axial intelligent fan USER S MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

USER S MANUAL. VKP Series INLINE FAN

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

Turbo Inline Fan, White - Non Illuminated Art no.33500

White - Non Illuminated Art no White - Cool White LED Art no.32600

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Centrifugal inline fans

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

HEAT RECOVERY VENTILATOR

USER'S MANUAL PS

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Air handling unit. BlauAir RH USER S MANUAL

USER S MANUAL DN-2. Drain pump

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

AIR HANDLING UNIT WITH HEAT RECOVERY

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Centrif Duo & Centrif Duo Plus

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

HEAT RECOVERY AIR HANDLING UNITS

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation manual Mini Comfort 50 S/L 07/ V EN

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

VH60SS 60CM VISOR HOOD STAINLESS STEEL

G Installation manual Solitude - dmev unit

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

ISCG90SS _03 ISCG90SS

Lo-Carbon Quadra Centrifugal Fan

MODELS HS 1500-OWO HS-1500-OTR INFRARED ELECTRICAL HEATER SAFETY INSTRUCTIONS & OPERATION MANUAL

Lo-Carbon SELV Tempra

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

General safety precautions English

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

Cooker Hood LA-72-CAN.

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

MODELS HS 1300-WS HS-1500-CR HS-1300-TR

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL UET CONTROL UNIT FOR THE AIR HEATING UNIT WITH ELECTRIC HEATER AOE SERIES

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

General safety precautions English

Lo-Carbon Quadra SELV

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

EVG Extractors. Manual for Installation, Use and Maintenance

HEATING AND COOLING DEVICE AGC

DESIGNER WALL CANOPY

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

MHG201 Gas Hob Manual for Installation, Use and Maintenance

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Box60/ 70/ 90. Box60_70_90 v8

Transcription:

Calm E ervice Instructions

BAUBERG VETIATORE GmbH is happy to offer you a new generation product, the BAUBERG Calm fan. The solid team of high-qualified professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fan in its class. BAUBERG ileo fan is the combination of design, high performance and silence operation. ITRODUCTIO The present operation manual contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan BAUBERG ileo. UE BAUBERG ileo fan is designed for ventilation of residential and public premises heated during winter season and is constructed for wall or ceiling mounting, fig. -4. The fan is equipped with a back valve to prevent air backdrafting when the fan is off. COMPETE ET The complete set includes: ame umber Fan item crews and dowels 4 item Plastic screwdriver (for the models with a timer) item Operation manual item Packing box item The fan design is regularly improved, so some models can slightly differ from those ones described in this operation manual.

BAIC CHARACTERITIC Table. Technical data Model Parameters Power voltage and frequency [V/Hz] Calm 00 0/50 7.5 Rated power [W] Max. air flow [m /h] - RPM [min ] oise level, m [dba] Calm 5 Calm50 min max Calm Max 50 min max 0/50 0/50 0/50 0/50 0/50 7 7 9 9 97 87 5 8 8 75 65 5 540 070 780 00 5 8 8 Fan model Option Calm 00 Calm 00 Calm 00 T Calm 00 H Calm 00 T Calm 00 H Calm 00 IR Calm 5 Calm 5 Calm 5 T Calm 5 H Calm 5 T Calm 5 H Calm 5 IR Calm 50 Calm 50 Calm 50 T Calm 50 H Calm 50 T Calm 50 H Calm 50 IR Calm Max 50 Calm Max 50 Calm Max 50 T Calm Max 50 H Calm Max 50 T Calm Max50 H Calm Max 50 IR Table. Fan modifications witch Turn-on delay timer Turn-off delay timer Humidity sensor Motion sensor witch integrated pull cord switch. Timer turn-on delay timer adjustable from 0 up to minutes (only Calm 50 and Calm Max 50 models) and turn-off delay timer adjustable from up to 0 minutes. Humidity sensor humidity control with set point from 60% up to 90%. Motion sensor reach distance from to 4 m and sensor viewing angle up to 00. The fan does not cause interference with radio-, TV- or video- equipment.

Table. Overall dimensions Dimensions [mm] Model a b c d e Calm 00 58 6 8 99 6 Calm 5 8 58 9 4 7 Calm 50 Calm Max 50 4 90 98 48 Fig. B H D OPERATIO RUE The fan is rated for connection to 0...40 V / 50 Hz power mains and is designed for continuous operation always connected to power mains. The air motion direction in the system must match the pointer on the fan casing. The fan is rated for operation at ambient temperature from + C up to +45 C. The fan does not require grounding. 4

AFETY RUE All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 000 V after careful study of the present user's manual. The single-phase power grid must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic switch that is used for connection of the fan to power mains with gap on all poles at least mm. Make sure the impeller, the casing and the grille are not damaged before connecting the fan to power mains. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the fan or any unauthorized modification are not allowed. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. ufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. The maximum permitted pressure difference per living units is 4 Pa. The transported air must not contain any dust or other solid impurities, sticky substances or fibrous materials. The fan is not rated for operation in a media that contains hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or block the fan intake or exhaust vent not to disturb the natural air passage. Do not sit on the fan and do not put objects on the fan. Follow the guidelines of this operation manual to ensure durable operation of the product. 5

MOUTIG AD ETUP The fan is designed for ceiling or wall mounting and installation into a ventilation shaft or connection to a round air duct of respective diameter, fig. -4. The fan mounting sequence is shown in fig. 5-. The wiring diagrams are shown in fig. 4-5. Fig. Fig. Fig. 4 6

Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 6 7

Fig. 0 Fig. Fig. Fig. 8

WIRIG DIAGRAM Fig. 4 Calm 00/5 Calm00/5 Calm 00/5 T Calm 00/5 H Calm 00/5 IR Fig. 5 Calm00/5 T Calm 00/5 H Fig. 6 T Calm 50 Calm MAX 50 Fig. 7 first speed 9 T

Fig. 8 Calm 50 Calm MAX 50 second speed Calm 50 Calm MAX 50 Fig. 9 first and second speed speed speed CDP-/5 CDP-/5 Calm50 Calm MAX 50 Fig. 0 first speed Calm 50 Calm MAX 50 Fig. second speed 0

Fig. Calm 50 Calm MAX 50 first and second speed speed Calm 50 T Calm MAX 50 T Calm 50 H Calm MAX 50 H Fig. Fig. 4 Fig. 5 Calm 50 T Calm MAX 50 T IEO 50 H Calm MAX 50 H IEO 50 IR Calm MAX 50 IR Calm 50 Calm MAX 50 Calm 50 Calm MAX 50

TIME AD HUMIDITY EOR ADJUTMET The control circuit board is under mains voltage! Disconnect the fan from power mains prior to adjustment operations! The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments. You can use the screwdriver to change the turn-on (only Calm 50 and Calm Max 50 models) and turn-off delay timer settings and to set the DIP switch into a required position (only Calm 50 and Calm Max 50 models). Do not use a metal screwdriver, knife, etc. for adjustment operations not to damage the circuit board. Fig. 6 Calm 50/Calm Max 50 Calm 00/5-0 min - H + min + - 60% Ton Toff + 90% min - 0 min Toff + - H + min 0 min O 4 DIP 60% 90%

FA PEED EECTIO The Calm 00 and Calm 5 models are the single-speed fans. The Calm 50 and Calm Max 50 models are the two-speed fans. The required speed for the basic models Calm 50 and Calm Max 50 as well as model modifications is set during connection to power mains. The required speed for the models 50 T/H/T/H/IR is selected by setting the DIP-switch on the electric circuit board into a respective position, fig. 6 and table 4. Use the plastic screwdriver from the delivery set to change the DIP-switch position. The fan models Calm 50 T/T/IR and Calm Max 50 T/T/IR have three operation modes and the fans Calm 50 H/H and Calm Max 50 H/H have five operation modes: Mode (single-speed mode) The fan is turned off by default. The fan starts running at the first speed in case of actuation of any sensor or the switch closing. Mode (two-speed mode) The fan is turned off by default. The fan starts running at the second speed in case of actuation of any sensor or the switch closing. Mode (two-speed mode) The fan runs at the first speed by default. The fan starts running at the second speed in case of actuation of any sensor or the switch closing. Mode 4 (two-speed mode) The fan is turned off by default. The fan starts running at the first speed in case of the switch closing and switches to the second speed in case of actuation of the humidity sensor. Mode 5 (two-speed mode) The fan is turned off by default. The fan starts running at the first speed in case of the switch closing or the humidity sensor actuation. If the switch is closed or the humidity sensor is actuated during the fan running at the first speed, the fan switches to the seconds speed. ATTETIO! Mode is set by default.

Operation mode is selected during the fan mounting or during the fan operation from three or five operation modes. Do not set the DIP switch in any other position except those positions that are stated in the table 4. Otherwise it may result in the emergency mode which is confirmed by the light indicator blinking. In this case disconnect the fan from power supply and set the DIP-switch into required position in compliance with the table 4. Table 4. Operation mode selection Operation mode Calm 50 T Calm Max 50 T Calm 50 T Calm Max 50 T Calm 50 IR Calm Max 50 IR O 4 Operation mode Operation mode Operation mode 4 Operation mode 5 O O 4 4 Calm50 H Calm Max 50 H Calm 50 H Calm Max 50 H O O 4 4 FA OPERATIO MODE IDICATIO The light indicator glows yellow during operation of all the Calm 00, Calm 5 models as well as Calm 50, Calm Max 50 basic and models. The light indicators glows as shown in fig. 7 during operation of the fan models Calm 50 and Calm Max50 T/T/H/H/IR. Fig. 7 o signal from sensors or switch 5 ek Green Humidity sensor or motion sensor is activated Turn-on delay timer is activated ek Green Red Turn-off delay timer is activated witch is closed ek Red Green Green 4

FA OPERATIO OGIC Turn-on delay timer - in case of the switch closing or activation of the humidity or motion sensor the timer countdown from 0 up to minutes is activated. Within this time the fan remains in the previous operation mode. If the switch is not opened or the sensor keeps registering high humidity or motion after the timer countdown, the fan switches to the first or to the second speed depending on the selected operation mode. Turn-off delay timer in case of the switch opening, indoor humidity drop below the set point or no motion registration the timer countdown from up to 0 minutes is activated. Within this time the fan remains in the previous operation mode. After the timer countdown the fan switches off or switches to the first speed, depending on selected operation mode. Humidity sensor if the indoor humidity rises above the set point from 60% up to 90%, the fan either turns on or switches to the second speed depending on the set operation mode, with respect to the turn-on delay timer setting. The fan keeps operating at this speed until the humidity drops to the set point. After that the turn-off delay timer is activated. Motion sensor in case of motion detection the fan either turns on or switches to the second speed, depending on the set operation mode, with respect to the turn-on delay timer setting. The fan keeps operating at this speed until the motion sensor keeps detecting movement. After that the turn-off delay timer is activated. Pull-cord switch or the external switch (models T and H) in case of the switch closing the fan either turns on or switches to the second speed, depending on the set operation mode, with respect to the turn-on delay timer setting. After the switch is opened the turn-off delay timer is activated. The recommended turn-on delay timer setting for the fan with an built-in switch is 0 minutes (factory setting). 5

MAITEACE Disconnect the fan from power mains prior to any servicing and maintenance operations. Maintenance means regular cleaning of the fan surfaces of dirt and dust. To clean the fan, wipe its surfaces with a cloth wetted in a mild soap solution, then wipe the surfaces dry, fig. 8-. Avoid water dripping on the motor and circuit board! Fig. 8 Fig. 9 Fig. 0 atches 6

Fig. Fig. Fig. TORAGE AD TRAPORTATIO RUE Transportation is allowed by any transportation vehicle provided that the product is in the manufacturer's original package. tore the delivered product in the manufacturer's original packing box in a dry ventilated premise with the ambient temperature from +5 C up to + 40 C and relative humidity less than 80%. The storage environment must be free of dust, acid or alkali vapours to prevent corrosion. 7

MAUFACTURER' WARRATY The fan complies with the requirements according to the EU norms and directives, to the relevant EU-ow Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 004/08/EC, 89/6/EEC and ow Voltage Directive 006/95/EC, 7//EEC and CE-marking Directive 9/68/EEC on the approximation of the laws of the Member tates relating to electromagnetic compatibility. This certificate is issued following test carried out on samples of the product referred to above. Assessment of compliance of the product with the requirements relating to electromagnetic compatibility was based on the following standards. Protection degree index according to IP rating against access to hazardous parts and water ingress is IP 45 for Calm 00, Calm 5, Calm 50 and IP X5 for Calm Max 50 model. The fan is double insulated and does not require grounding. The warranty operation period (service life) of the fan is five years from the retail sale date provided observance of the installation and operation regulations. In case of the product malfunctions caused by a manufacturing fault during the warranty period the consumer is entitled for the fan replacement or its warranty repair. WARIG!!! In case of a claim for the product replacement please submit the operation manual with the sales confirmation and/or a payment document that confirms the product sales. If case of no confirmation of the sale date, the warranty term shall be calculated from the manufacturing date. By purchasing this product the user confirms to have read and accepted the operation manual conditions as well as operation, storage, transportation, mounting, setup, wiring, servicing, repair and warranty rules applicable to the product stated in the attached technical documentation. Do not dispose in domestic waste. The product contains in part material that can be recycled and in part substances that should not end up as domestic waste. Dispose of the product once it has reached the end of its working life according to the regulations valid where you are. 8

ACCEPTACE CERTIFICATE 9

Calm Calm Max 00 5 50 T H T H IR Fan is recognized as serviceable. AE DATE OD MAUFACTURED O (DATE): APPROVA MARK Calm_E-07