4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Similar documents
SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

4YCC3048A3096A /3/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A

SEER 1½

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, KBTU R-410A

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 07/08

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

Product Data WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

RGE 13 A T - 1 A

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Advance Release September 2009

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

PAR5. Product Specifications

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Split System Cooling Product & Performance Data

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Split System Cooling Product & Performance Data

Split System Cooling Product Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Split System Cooling Product Data

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data. Split System Heat Pump D-EN. February 2016

Split System Cooling Product Data

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

50TM COMBINATION HEATING/COOLING UNITS

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Product Data. Fig. 1 - Unit 50VR -A

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

13 GEP A L P - 1 A

Split System Heat Pump Product & Performance Data

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Product Data. Split System Heat Pump A-EN. March 2016

48TM GAS HEATING/ELECTRIC COOLING UNITS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

SKYPAK II, 3 Ton Series, gives you a

PAJ3. Product Specifications

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Modular Multi-position Air Handler

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Cooling A. November 2013

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

High Heat COP. High/Low Stage

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

PACKAGE AIR CONDITIONER

AMERICAN STANDARD 14 MODELS 4A7B E

SKYPAK II, 3 Ton Series, gives you a

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Cooling/Heat Pump Convertible Air Handlers

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DCG Commercial. Submittal Data Form

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

SKYPAK II Heating & Cooling Self Contained Packages

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

WPH4 Product Specifications

Split System Cooling Product Data

Vertical Upflow Horizontal Left Air Handlers

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Split System Heat Pump Product Data

Split System Heat Pump Product Data

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Transcription:

4YCC3036A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)] 7 Performance Heating 2 Input BTUH (Natural Gas) 3 AFUE Temp. Rise Min/Max ( F) Orifice Qty / Drill Size (Natural Gas) POWER CONN. V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size Max. (amps) Fuse Size Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 8 Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 5 Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN TYPE Drive/No. Speeds Motor HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) 6 REFRIGERANT Charge (lbs.) 4 GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCC3036A1064B 35000 1200 3.284 11.0 / 13.0 75 600 80.0 25 / 55 2 / #37 25.2 SCROLL 16.7 / 79 SPINE-FIN 2 / 24 13.32 PLATE FIN 4 / 15 3.54 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 32 1/5 / 830 1.1 / 1.9 10 X 10 DIRECT / 2 SEE FAN PERF TBL 1/2 / 1075 200-230/1/60 3.2 / 6.7 1/35 / 3480 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 488 / 392 4YCC3036A1075B 35000 1200 3.284 11.0 / 13.0 75 75000 80.0 30 / 60 2 / #33 25.2 SCROLL 16.7 / 79 SPINE-FIN 2 / 24 13.32 PLATE FIN 4 / 15 3.54 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 32 1/5 / 830 1.1 / 1.9 10 X 10 DIRECT / 2 SEE FAN PERF TBL 1/2 / 1075 200-230/1/60 3.2 / 6.7 1/35 / 3480 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 488 / 392 SPECIFICATIONS 4YCC3036A1096B 35000 1200 3.284 11.0 / 13.0 75 96000 80.0 / 70 3 / #37 25.2 SCROLL 16.7 / 79 SPINE-FIN 2 / 24 13.32 PLATE FIN 4 / 15 3.54 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 32 1/5 / 830 1.1 / 1.9 10 X 10 DIRECT / 2 SEE FAN PERF TBL 1/2 / 1075 200-230/1/60 3.2 / 6.7 1/35 / 3480 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 493 / 397 4YCC3036A1064/75/96B 1 Rated in accordance with AHRI Standard 210/2. AHRI standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG 4 This value is approximate. For more precise value, see Unit Nameplate. 2012 American Standard Heating and Air Conditioning 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 0.05" W.C. 7 Sound Power values are not adjusted for AHRI270-95 tonal corrections. 8 Standard Air Dry Coil Outdoor. The Manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.

SINGLE PACKAGED GAS HEATING ELECTRIC COOLING Unit Clearance and Weight Information American Standard Heating & Air Conditioning www.americanstandardair.com 2

Unit Clearance and Weight Information 3

SINGLE PACKAGED GAS HEATING ELECTRIC COOLING Unit Clearance and Weight Information American Standard Heating & Air Conditioning www.americanstandardair.com 4

Unit Performance Data Indoor Fan Performance 4YC*3036A Horizontal Airflow 4YC*3036A-HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 470 448 434 420 2 378 351 - - - - CFM 1332 1292 12 1177 1100 1007 896 - - - - HIGH WATTS - 670 651 634 616 595 569 536 498 - - CFM - 1542 1472 1426 1364 1267 1135 989 869 - - Down Airflow 4YC*3036A-DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 460 445 431 416 0 381 358 - - - - CFM 1267 1257 1198 1124 1050 966 843 - - - - HIGH WATTS - 713 694 676 657 636 612 588 - - - CFM - 1584 1502 1420 1327 1221 1100 970 - - - 5

SINGLE PACKAGED GAS HEATING ELECTRIC COOLING Optional Equipment BAYCURB050A Full Perimeter Roof Mounting Curb FOR *****018-036 17 7/8 46 3 3 5/8 19 1/2 2 3/16 15 19 1/2 38 7/8 1 1/2 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 35 7/8 43 American Standard Heating & Air Conditioning www.americanstandardair.com 6

Optional Equipment BAYFLTR101, 201B, 1" - 2" Filter Rack - (Mounts in Filter/Coil Section) Filter BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door - Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 7

SINGLE PACKAGED GAS HEATING ELECTRIC COOLING Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood - (Mounts Over Horizontal Return Air Opening) A HVAC Unit Economizer rain hood Mist eliminator Relief damper Roofcurb Outside air dampers Return air dampers Required filter kit, order separately Return Duct ECONOMIZER BAYECON101A BAYECON102A UNIT APPLICATION MODELS 4TC*,WC*,YC*,DC* *018-036 4TC*,WC*,YC*, DC* *042-060 A 20.125" 24.375" BAYECON200,201A Horizontal Economizer and Rain Hood The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Duct Economizer C A B D E Gaskets (2) Rain Hood Mixed Air Sensor ECONOMIZER A B C D E F BAYECON200AA 22" 20" 16 7/8" 15 11/16 11 11/16 15 BAYECON201AA 26" 22 21/32" 19" 17 11/16 14 11/16 21- American Standard Heating & Air Conditioning www.americanstandardair.com 8

Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper - (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. D C A B FULLY OPEN 2/3 1/3 FULLY CLOSED MANUAL FRESH AIR MODEL UNIT APPLICATION MODELS A B C D BAYOSAH001 BAYOSAH002 4YC,WC3018-036 4TC*3018-036 4W/T/Y/DCY24-036 4W/Y/DCZ6036 4YC,WC3042-060 4TC*3042-060 4W/T/Y/DCY42-060 4W/Y/DCZ6048-060 22 7/16" 20 11/16" 12 " 9 3/16" 25 3/16" 20 11/16" 12 " 9 3/16" BAYDMPR101,102A, 25% Motorized Outside Air Damper - (Mounts Over Horizontal Return AIr Opening) A C B E D UNIT APPLICATION MODELS A B C D E BAYDMPR101A BAYDMPR102A 4YC,WC3018-036, 4TC3018-036 4W/T/Y/DCY24-036, 4W/Y/DCZ6036 4YC,WC3042-060,4TC3042-060 4W/T/Y/DCY42-060, 4W/Y/DCZ6048-060 15 13/16" 11 13/16" 10 1/4" 11 1/2" 12 1/4" 18 3/16" 15 1/8" 10 1/4" 11 1/2" 12 1/4" 9

MECHANICAL SPECIFICATIONS General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities shall be rated in accordance with AHRI standards. The 4YCC3 heating/cooling unit design is certified to ANSI 221.47/CSA 2.3, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weatherresistant powder paint. Shipped for horizontal application, convertible to downflow. Casings All panels shall be heavy gauge steel, gasketed and insulated. Foil-faced insulation shall be in the heat exchanger section. Foilfaced insulation shall be in the evaporator section. Base pan shall be heavy gauge steel. WEATHERGUARD exterior corrosion resistant screws shall be used for added resistance to rust and corrosion. Controls Refrigeration cycle controls shall include condenser fan, evaporator fan and compressor contactors. Compressors shall be equipped with a combination internal winding thermostat/current overload. Internal high pressure relief shall also be provided. Refrigeration System Compressors The Duration compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other features include: centrifugal oil pump, and low vibration and noise. Evaporator Coil Internally enhanced inch OD seamless copper tubing me chani cally bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig. All units have TXV to control refrigeration flow. Condenser Coil The Spine Fin condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is inch OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Direct-drive, forward-curved, centrifugal wheel in a Composite Vortica Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan Direct-drive, draw through propeller type. Weather-proofed permanent split capacitor fan motor shall have built-in thermal overload and permanently lubricated motor bearings. Low Ambient Standard refrigerant system operation down to 55 F. Low ambient accessory required for operation to 0 F ambient condition. Gas-Fired Heating System Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electronic Ignition System Main burner is lit each time thermostat calls for gas heat. Flame sensor proves flame and keeps the main burners on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 second. When thermostat is satisfied, main burner is extinguished. Forced Combustion Blower Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger Stainless steel tubes. Free floating design. Burners Stainless steel. Multi-port inshot. Accessories (U.S. Domestic Models) Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weather-tight installation when properly installed. Curb shall ship knocked down for field assembly, and include wood nailer strips. Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor fixed dry bulb enthalpy control, and low voltage polarized plug for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometric relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment off cycle. Manual Fresh Air Hood Manual outside air provides a fixed outside air quantity from 0 to 25 percent. Includes hood and birdscreen. Low Ambient Control Control allows cycling of compressor under low ambient cooling conditions. Required for cooling operation to 0 F. Propane Gas Conversion Kit For conversion from natural gas to LP gas. American Standard Heating & Air Conditioning www.americanstandardair.com