Portable sample gas conditioning PCS.smart+

Similar documents
Portable sample gas conditioning PCS.smart

Gas cooler series TC-Standard+

Gas cooler series RC 1.1

Gas cooler series TC-Standard+ X2

Gas cooler series RC 1.1

Portable sample gas conditioning. PCS.smart (+) Installation and Operation Instructions. Original instructions. Analysentechnik BE /2017

Portable sample gas conditioning. PCS.smart (+) Installation and Operation Instructions. Original instructions. Analysentechnik BE /2018

Peristaltic condensate pumps CPsingle, CPdouble X2 (Versions with ATEX 2, IECEx and Cl.1 Div.2 approval)

Sample Gas Probes Series GAS 222

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

Compact Gas Conditioning MAK10

VC-1, VC-1-SL, VC-2-L, VC-2-SL

Vacuum drying oven for non-flammable solvents

gas monitoring system

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

HYGROPHIL H process hygrometer

2 OZONFILT And Bono Zon Ozone Plants

EC Ultra Low Gas Cooler EC-30C Instruction Manual Version Software Version 1.00

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Ultra Low Gas Cooler Series EC EC30 and EC-30/FD

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

portable gas analyser

Rotavapor R-220 SE Technical data sheet

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Safety vacuum drying oven for flammable solvents

Dew point set DS 400

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Users Manual Pury 250e Gas Purification System

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Certificate: / 9 September 2014

Differential pressure gauge with electrical contact type Model: P650 series

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Heated Gas Sampling Probe PSG Basic

Short Path Distillation Unit. KDL 1 BASIC Version 2015

Rotavapor R-220 Pro Technical data sheet

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

VD 53 - Vacuum drying oven for non-flammable solvents

Rotavapor R-220 Pro Technical data sheet

Refrigerant Dryers Refrigerant Compressed Air Dryer with integrated DF Filters

Company profile. ANKERSMID is a privileged partner of several companies like Siemens, BASF, Bayer, Umicore, Dräger and many more.

Safe Enclosure Cooling

BURAN OEM DC 0020 AB - DC 0850 AB

LAUDA Additional devices Immersion coolers, through-flow coolers, circulation heat exchangers

Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE. What You Measure, We Manage

KMF Environmental test chamber for constant climate

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Gas cylinder scale Model GCS-1

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

6-2.1 ANKERSMID Diaphragm pump Application No contamination of the media AMP 510/518/530 due to oil-free operation Low maintenance

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

OEM Sensors for HVAC manufacturers Heat recovery Chiller

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL

Heat Exchanger Earny Type

Vacuum Pumps for moist Gases. Self-drying Vacuum Pump for moist Gases. Series LABOPORT SD N FT Vacuum Pump. Spare parts.

Ultrasonic Proximity Sensor

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

portable gas analyser

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

Environmental simulation chamber for complex alternating climate profiles

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Snifter. User Manual. Distributor

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press (bar g) (kg)

Cooling with compressed air partial flow: the Heat Regenerating Adsorption Dryer EVERDRY FRP

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Temperature measurement with current output and PNP/NPN transistor switching output output 2 reprogrammable as switching output TS-400-LI2UPN8X-H1141

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Chemical Pumps Vertical Chemical Pump Type TNP

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

DATA SHEET 01. Function. Features SUP. OUT EX optional OUT EX OUT SUP OUT SUP. Customized connection possibilities as standard.

TA-SCOPE. Balancing instrument ENGINEERING ADVANTAGE

Sintrol Snifter A1+ Manual. Version 1.2.2

Lamp Supply (Recommended)

Infrared Detectors. Special-Sensors for. Automation

M7100 Pressure Transducer

Constant climate chamber with ICH-compliant illumination

Electronic Temperature Controller 70304,

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

General Specifications

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Emission Monitoring System

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

Constant climate chamber with humidity

Adsorption dryer PDAD. (en) Operating instructions g [ ]

Operation Manual. Time controlled condensate drain unit UFZ. 000_H_uf_UFZ_GB_R00_D011002

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Labkotec Ice Detector

ULTRAFLOW 54 DN

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

NT 75/2 Ap Me Tc. On-board storage. ApClean (semi-automatic filter cleaning system) Integrated drain hose. Hose and bend attachment

Dry Bath Heating Systems

Constant climate chambers

DRI-AIR INDUSTRIES, INC. HA750B B HOT AIR DRYER OPERATING MANUAL

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Transcription:

Gas Analysis Portable sample gas conditioning PCS.smart+ Carrying out accurate and reliable gas analyses in changing locations requires a small, compact gas conditioning system. We developed a complete sample gas conditioning system protected inside a case for this application. The basic version of this system consists of a gas cooler with condensate pump and a filter. A gas pump, moisture detector, flow meter or temperature controller are optional. The sample gas cooler cools the sample gas to the preset dew point (factory preset +5 C) regardless of the ambient temperature. The safety circuit only activates the sample gas pump once the cooler has reached its operating point. The sample gas cooler in the PCS.smart+ features a new generation heat exchangers with a particularly low scrubbing effect of water-soluble components and are specifically suitable for measuring emissions. The PCS.smart+ can therefore be used for measurements according to EN 15267-4. Low scrubbing effects of water-soluble gas components Particularly suited for sample measurement in emissions monitoring Adjustable outlet dew point and alarm thresholds TC-Standard OEM Cooling system with 80 kj/h nominal capacity Optional moisture detector, sample gas pump, flow meter, bypass Optimal for Smartline heated line or alternative heated lines Optionally available with built-in controller up to max. 1600 W DE464006 08/2018 page 1 / 6 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 E-Mail: analyse@buehler-technologies.com Internet: www.buehler-technologies.com

Description and Function The PCS.smart series portable gas conditioners offer a variety of options and other useful features for a variety of applications. An optional built-in type P1 sample gas pump with bypass valve and flow meters is available to supply up to two gas outputs separately. A heated line can be connected directly. An unregulated or regulated sample gas line can be connected. The PCS.smart will also control the temperature. The Smartline is specially coordinated and as a heated line with panel filter can simultaneously also be used as a portable probe. We offer a variety of gas inlet or outlet fittings which can be mixed and matched. The "cold start" function ensures it is ready for use quickly if the storage temperature before use is +5 C. Unlike the PCS.smart (see data sheet no. 464005), the PCS.smart+ has two heat exchangers. The special configuration of the PCS.smart+ reduces scrubbing of water-soluble gas components. This makes the PCS.smart+ particularly suited for sample measurement when monitoring emissions. Flow chart PCS.Smart+, Item No. CSPS 2xxx 1 Cooler 6 Filter 2 Condensate pump 7 Sample gas pump with bypass (optional) 3 Cooler 8 Flow meter (optional) 4 Condensate pump 9 Flow meter (optional) 5 Moisture detector (optional) Technical Data Technical Data PCS.smart Ambient temperature: +5 to 50 C 1) Gas output dew point: Warning thresholds: Flow rate: approx. 50 280 L/h 2) Operating pressure: 0.2 2 bar abs. 2) Dew point static throughout the range: adjustable, 2 20 C adjustable, -3-1 K and +1 +7 K around dew point 0.1 K ±1.5 K Inlet dew point max.: 70 C 1) Gas inlet temperature: max. 140 C 1) 2) 3) Rated cooling capacity (at 25 C): 80 kj/h Electric supply: IEC connector, termination length: Power input: Operational readiness: Dimensions without line (h x w x d): Weight standard version: 230/115 V, 50/60 Hz 2.5 m max. 250 VA (without heated line) after approx. 10 min. approx. 460 x 360 x 260 mm approx. 13.5 kg Parts in contact with media: PVDF, glass, stainless steel, PTFE, Norprene, Viton, epoxy resin, sintered PTFE 2) Protection class: IP 20 D 1) Considering the available total cooling capacity (see Technical Data TC-Standard OEM). Please also refer to our calculation program or contact our sales department for guidance. 2) May vary due to optional add-on parts. 3) Subject to installation conditions 2 Bühler Technologies GmbH We reserve the right to amend specification. DE464006 08/2018

Technical Data - Options Technical Data Sample Gas Pump P1 Inlet: Outlet: Nominal output: Technical Data DK 702 Flow Meter Standard measuring tubes: Meas. range: Options: 0.5 1.3 bar abs. Back-pressure max. 1 bar rel. 280 L/h (at p = 1 bar abs.) Air 20 C, 1.2 bar abs. 25 250 NL/h Built-in needle valve Technical Data Controller for heated line Temperature, preset: adjustable: 100 C 40 C 200 C Motor power: max. 1600 W (230 V) / 800 W (115 V) Sensor type: Connection: Output PCS.smart+ Rated cooling capacity (at 25 C) Pt100, 2-wire 693 series socket, 7-pin 80 kj/h Max. Ambient temperature 50 C Dew point fluctuations static in the entire specification range Temperature difference between heat exchangers ± 0.1 K ± 1.5 K < 0.5 K Cooling capacity kj/h PCS.smart+ Limit for 2x MTV-2 Ambient temperature C Remark: The limit curve for the heat exchanger applies to a dew point of 50 C. DE464006 08/2018 We reserve the right to amend specification. Bühler Technologies GmbH 3

Heat exchanger description The energy content of the sample gas and the required cooling capacity of the gas cooler is determined by three parameters: gas temperature ϑ G, dew point τ e (moisture content) and volume flow v. The outlet dew point rises with increasing energy content of the gas. The following limits for the maximum flow are specified for a standard operating point of τ e = 40 C and ϑ G = 70 C. Indicated is the maximum flow v max in Nl/h of cooled air, so after moisture has condensed. Values may differ for other dew points and gas inlet temperatures. However, the physical facts are so vast we decided to omit the illustration. Please contact our experts for clarification or refer to our design program. Volume flow temperature chart T e V max [NL/h]* 40 205 50 180 65 100 *at 25 C ambient temperatures. Heat exchanger overview Heat exchanger Version / Material 1) Flow rate v max 1) Inlet dew point τ e,max 1) Gas inlet temperature ϑ G,max Max. Cooling capacity Q max 2x MTV-2 in-line PVDF 100 NL/h 70 C 140 C 90 kj/h 1) Considering the maximum cooling capacity of the cooler 4 Bühler Technologies GmbH We reserve the right to amend specification. DE464006 08/2018

Ordering instructions The item number is a code for the configuration of your unit. Please use the following model key: PCS.smart+ CSP S 2 X 8 1 X X X 2 X X X 0 X X Product characteristic Supply voltage 1 115 V AC 2 230 V AC Heat exchanger 8 PVDF Filter 1 Panel filter, AGF-FE-4 Moisture detector 0 without moisture detector 1 with moisture detector Sample gas pump and flow meter 0 0 none 0 3 without P1, 1x flow meter with needle valve 2 0 P1 with bypass, without flow meter 2 1 P1 with bypass and 1x flow meter 2 4 P1 with bypass and 2x flow meters with needle valve 1) 2 5 P1 with bypass, 1x flow meter and 1x flow meter with needle valve Condensate pump 2 2x CPsingle with angled adapter Gas inlet 0 Screw connection, metric, PVDF, DN 4/6 2) 1 Screw connection, US, PVDF, 1/4" / 1/6" 2) 2 Screw connection, metric, stainless steel, 6 mm 3) 3 Screw connection, US, stainless steel, 1/4" 3) 4 Quick-coupler with counter piece, metric, PVDF, DN 4/6 2) 5 Quick-coupler with counter piece, US, PVDF, 1/4" / 1/6" 2) 6 Quick-Lock 2) Gas outlet 0 Screw connection, metric, PVDF, DN 4/6 1 Screw connection, US, PVDF, 1/4" / 1/6" 2 Screw connection, metric, stainless steel OD, 6 mm 3 Screw connection, US, stainless steel, 1/4" 4 Quick-coupler with counter piece, metric, PVDF, DN 4/6 5 Quick-coupler with counter piece, US, PVDF, 1/4" / 1/6" 6 Quick-Lock heated line 0 0 none 2 0 heated line Status outputs 0 status output only 1 Analogue output option, add-on Trolley 0 No 1 Yes CSP S 2 8 1 2 0 Order key 1) Version 2 x SM with needle valve includes an additional bypass gas outlet. The connection corresponds with the selected gas outlet configuration. 2) Maximum medium temperature 140 C. 3) Recommended for connecting a heated line. DE464006 08/2018 We reserve the right to amend specification. Bühler Technologies GmbH 5

Spare parts and accessories Item no. Description CS PX 00012 Removable trolley case with 50 mm casters; aluminium 44 92 00 35 012 Norprene replacement hose with angled connections for peristaltic pump 0.3 L/h 41 15 10 50 FE-4 spare filter, 8 count 42 28 00 3 Bellow for P1 pump 90 09 39 8 O-ring for bypass P1 pump 42 28 06 6 Set inlet/outlet valves 70 C for P1 pump see data sheet 4640002 Smartline 6 Bühler Technologies GmbH We reserve the right to amend specification. DE464006 08/2018