Multi-Heat. Multi-Heat Datasheet Version Tarm Biomass 4 Britton Lane Lyme, NH 03768

Similar documents
Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60. Benefits at a Glance:

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60, 80/100. Benefits at a Glance:

Econoburn Technical Datasheet

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

Technical Data Manual Model Nos. and pricing: see Price List

Bonus Plus. Installation and Operations Manual. Model 30. Wood-fired central heating boiler

Before selecting your stove, it is very important that you clearly identify what your needs are:

SOLO PLUS. Installation and Operations Manual. Models 30, 40, and 60. Wood-fired central heating boiler

Boiler Technical Specifications (2013)

Owner s Manual for. PennStoker

Before selecting your stove, it is very important that you clearly identify what your needs are:

CHIMNEYS AND VENTS CHAPTER 8

SOLO PLUS. Installation and Operations Manual. Models 30, 40, and 60. Wood-fired central heating boiler

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Technical Data Manual Model Nos. and pricing : See Price List

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Funnel Casing -- ZENON, I M NOT SURE WHAT THIS IS. I CAN DELETE REF- ERENCE TO IT OR PROVIDE SOME DETAIL IF YOU CAN HELP ME UNDER- STAND IT.

iq1001, Gen II Submittal Data

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

CHAPTER 8 CHIMNEYS AND VENTS

Technical Data Manual Model Nos. and pricing : See Price List

CHAPTER 8 CHIMNEYS AND VENTS

CHIMNEY INSTALLATION. Technical Bulletin #1

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Utica Boilers MAC Submittal

Get The Edge Over The Competition with The Summit

Boiler Manual Installation and Operation Instructions

HEATING WITH WOOD Wood Boiler Planning Guide. Boiler Planning Plumbing Layouts Thermal Storage Clearances Wiring.

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Boiler Manual. Finned Copper Tube Gas Boilers (MB) & Water Heaters (MW) Installation and Operation Instructions. HeatNet Control Manual

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

HEATING WITH WOOD Wood Boiler Planning Guide. Boiler Planning Plumbing Layouts Thermal Storage Clearances Wiring.

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

NY Thermal Inc. WF-200 Wood Fired Boiler

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Introduction Engineering and Design Manual

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

iq251, Gen II Submittal Data

Peerless Boilers. Series MI. Residential Gas Boilers

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

Computer Controller. The Bio-Burner has user regulated settings as well as built-in safety features to protect you and your burner.

DIVISION FINNED WATER-TUBE WATER HEATERS

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

POWER VENTER. Model: PVE Series

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

C1210ES Tankless Water Heater

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Technical Data Manual Model Nos. and pricing : See Price List

C1050ES Tankless Water Heater

INSTALLATION AND SERVICE MANUAL. Hot Water Heating Boilers Domestic Hot Water Supply Boilers 399, ,000 Btu/hr Models

Installation & Operation Manual Models:

Installation & Operation Manual Models: 502, 752, 1002, 1302, 1501, 1701, and 2001 Up To 5:1 Turndown

Project Name: Location: Engineer: Contractor: I. GENERAL

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Hitzer Energy Master II Stoker Furnace Model 710 Owner s Manual Installation and Operation

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

PUSHING THE LIMITS OF WHAT IS POSSIBLE

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

i200, Gen II i250, Gen II Submittal Data

DIVISION FINNED WATER-TUBE WATER HEATERS

FINNED WATER-TUBE POOL HEATERS

DESIGNER S GUIDE COPPER-FIN

Columbia Boiler Company

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Commercial Gas Water Heaters

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Installation & Service Manual Models:

DOMESTIC WATER HEATER OIL FIRED

napoleonfireplaces.com WOOD BURNING WOOD BURNING FIREPLACES

INSTALLATION AND OPERATING INSTRUCTIONS

MFC Series Boiler Vent and Combustion Air Guide

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Installation & Operation Manual Models:

Single stage operation oil burner

DIVISION FINNED WATER-TUBE BOILERS

Wood Boiler Plumbing Schematics

Corn Flame Energy Corn Stove Model 3000

Suggested Specifications Prestige Excellence 110

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Pellet Vent INSTALLATION INSTRUCTIONS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

940ES Tankless Water Heater

Before selecting your stove, it is very important that you clearly identify what your needs are:

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

INSTALLATION AND SERVICE MANUAL

GS Series. Installation and Operation Manual

K-2 & K-6 with 6 Inch Stack

Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Triple-Flex High Efficiency Boilers

Transcription:

MULTIHEAT Models.5, 2.5 and 4.0 Technical Datasheet MultiHeat High quality wood pellet and corn fired boiler with variable heat output from 3000%. Designed for hydronic heating systems. Heat output ranging between 546 MBH. Benefits at a Glance: Burns wood pellets and corn which are economical, environmentally friendly and domestic fuel sources. MultiHeat boilers can be very easily incorporated into existing heating systems. Combustion efficiency of up to 9%. Constant heating gives optimum building comfort. Simple operation via a multifunctional digital control on the front panel. No storage tank required. Automatic shutoff to prevent hopper burn back. Delivered fully assembled. Easy to position: Top flue exit and reversible doors provide maximum flexibility. Sturdy construction features include acidproof stainless steel (AISI 36L) in the combustion chamber and 6mm (¼ ) water cooled steel plates in the boiler interior. Automatic hopper refilling available.

Boiler Information Boiler CutAway Section 7 8 9 20 2 22 6 5 4 3 2 2 3 4 5 6 7 8 0 (This shows the MultiHeat 4.0) 9a 9. Boiler control panel 2. Upper cleaning door (reversible) 3. Heat exchange tubes and turbulators 4. Combustion area 5. Hot combustion area 6. Ash door (reversible) 7. Observation flap 8. Air apertures for the combustion 9. Fill/drain connection with valve (on type 2.5 this is placed between the fire box and the hopper) 9a. Drain plug for air ducts (on type 2.5 this is placed directly over the bottom frame on the righthand side) 0. Combustion chamber refractory. Cleaning opening (for hopper 2.5 and 4.0 only) 2. Fuel auger ( transport the fuel to the combustion area) 3. Burn back safety flood valve 4. Auger motor and gearbox 5. Blower fan 6. Air intake louvers 7. Ash cleanout cover (one on each side) 8. Fuel storage hopper 9. Cover for hopper 20. Flue gas exhaust collar 2. Supply and return water connections 22. Overheat coil

Specification Data Technical Data Units MH.5 MH 2.5 MH 4.0 MEASUREMENTS Depth Boiler & Fuel Hopper Total inches 56.5 62.2 66.7 Width Boiler or Fuel Hopper inches 9.9 23.6 23.6 Height including smoke pipe stub inches 45.9 58. 58. Fuel Hopper capacity Cu ft 7 2.7 2.7 Hopper Hatch dimensions (length x width) inches 5.8 X 5.8 20.5 X 20.5 20.5 X 20.5 Smoke Pipe Stub outside diameter inches 5.2 5.9 5.9 Weight Empty lbs 750 68 279 Water Contents gallons 3.2 33 39.6 Distance behind Boiler for replacing worm conveyor inches 3.5 39.4 39.4 Distance in front of Boiler to fully open doors inches 9.7 23.7 23.7 Space around Hopper for service access inches 4 4 4 OPERATING DATA Operating TemperatureWater 4085 4085 40 85 Nominal OutputWood Pellets or Corn Btu/hr 5,200 (pellets only) 85,300 46,700 Output at 30% (minimum)wood Pellets or Corn Btu/hr 5,700 (pellets only) 25,600 40,950 Approximate Output in Standby Btu/hr,700 (pellets only) 2,700 3,300 Smoke Temperature at Nominal OutputWood Pellets Corn Smoke Temperature at 30% OutputWood Pellets Corn Smoke Gas Volume at Nominal OutputWood Pellets Corn Fuel Consumption at Nominal OutputWood Pellets Corn Cu meters/hr Cu meters/hr lbs/hr lbs/hr Required Draft inch WC.04..04..04. Safety Listings UL 39995, CAN/CSA B366. M9,UL726, ANSI Z2.3200, CSA 4.9M2000 MultiHeat Datasheet 8007829927 Version 070 2 302 22 36 7.5 356 392 230 239 58 60 2.6 3.2 UL 39995, CAN/CSA B366. M9,UL726, ANSI Z2.3200, CSA 4.9M2000 356 392 230 239 93 97 22 24.3 UL 39995, CAN/CSA B366.M9,UL726, ANSI Z2.3200, CSA 4.9M2000 Noise Level Db(A) <70 <70 <70 ELECTRICAL DATA Boiler Power Requirement 240V60Hz/5A 240V60Hz/5A 240V60Hz/5A Electricity Consumption KW.3.46.46 Auger Motor KW.2.37.37 Blower W 90 90 90 Auger Motor Protection Setting Amps. 2.3 2.3 PIPING DATA Boiler Test Pressure psi 58 58 58 Cooling Coil Test Pressure psi 362 362 362 Boiler Relief Valve Setting psi 30 30 30 Supply & Return pipe stub size (male npt) inch Minimum Boiler Loop size inch.25.25 Cooling coil & fire suppression connection size inch.5.5.5 Fill/ drain valve size inch.5.5.5 Pressure Drop for 0 degrees C temperature difference psi.067.78.435 Mixing Valve Opening Setting 62 62 62 Internal Overheat Aquastat Setting 22 22 22

Specification Data 2 3 4 Description Units MH.5 MH 2.5 MH 4.0. Flue Pipe, External Diameter inches 5.25 5.875 5.875 2. Return Connection inches 3. Supply Connection inches 4. Burnback Protection Connection inches.5.5.5 L. Measurement inches 23 23 27.5 L2. Measurement inches 7.750 8.5 8.5 L3. Measurement inches 9.5 24.250 24.250 L4. Measurement inches 56.5 62.5 66.67 L5. Measurement inches 4.2.5 5.875 L6. Measurement inches 5 5 5 L7. Measurement inches 6.5 9.750 9.67 H. Measurement inches 39.750 50.375 50.375 H2. Measurement inches 45.875 50.375 50.375 B3. Measurement inches 9.750 23.625 23.625 3

Boiler Clearances Specification Data Clearances to Combustibles Measurement Minimum Distance Notes ABackwall to Appliance 8 Minimum Distance BBackwall to Appliance 40 Minimum distance for removal of feed auger from the rear of the MH 2.5 and MH 4.0 CSidewall to Appliance 6 Minimum Distance on left or right side DSidewall to Appliance 2 Minimum Distance on left or right side to allow clearance for cleaning and maintenance tasks. EFront of Appliance 36 Required distance for cleaning the boiler. FFront of Appliance 40 Minimum distance for removal of feed auger from the front of the MH 2.5 and MH 4.0 GCombustibles to Pipe 8 Minimum Distance HCeiling to Appliance 8 Minimum Distance 4

System Design Considerations Sizing The boiler is designed to operate continuously at its rated output. If it will be the only heat source in the building, the boiler should be capable of supplying the building s total heating load. When plumbed in parallel with a fossil fuel boiler capable of supplying the building s total heating load it is recommended that the MultiHeat boiler not be < 85% of the total heating load of the boiler. It is necessary to have a minimum constant load on the boiler when it is operating to prevent it from going into standby mode for long periods of time. A constant circulating loop is recommended. Chimney The boiler must be connected to a tilelined chimney or to a Factory Built Type UL 03 HT (ULC S629 in Canada) approved chimney. The chimney must be in good condition. No other appliance should be connected to this flue unless allowed by local code authority. Consult your local inspector for chimney requirements and install the boiler in accordance with all applicable codes. If corn burning is contemplated, use of higher grade stainless steel (a grade of 36 or higher is recommended). Flue gas exhaust temperatures can be low enough to cause condensation in chimneys. Condensation will, over time, damage a masonry chimney. Accordingly, installation of a stainless steel chimney liner (such as 36 or AL294C) inside the chimney flue is strongly recommended. The boiler has a builtin combustion blower fan. Therefore only small demands are made on the chimney draft. A 5 diameter flue is required for the model.5. A 6 diameter flue is required for the model 2.5 and 4.0. At the connection to a factorybuilt chimney, a dripless adapter must be used. The chimney draft must be stable and between 0.025 and 0.05 water column. Outside Combustion Air Provision for outside combustion air may be necessary to ensure that fuelburning appliances do not discharge products of combustion into the house. Guidelines to determine the need for additional combustion air may not be adequate for every situation. If in doubt, it is advisable to provide additional air. The MultiHeat boiler is not suitable for direct connection to outside air. Outside air should be ducted to no closer than 2 from the boiler. The boiler must not be installed in an area or room where there are flammable liquids or combustibles. Examples include, refrigerants, paint, thinner, bleach, etc. Boiler Location The boiler is not suitable for outdoor installation. It must be located in a weathertight, protected space. The boiler must be placed on a level and stable foundation. The floor on which the boiler sits must be made from a noncombustible material. Consider the logistics of delivering fuel to the boiler when choosing a boiler location. Electrical 240 VAC, 60 hertz, 4wire power supply is required. If building power is lower (208 VAC, for example), a boosting transformer should ne installed to correct the voltage. This electrical connection should be from a dedicated 5 amp, doublepole circuit breaker. Water Quality If water quality is poor, water treatment should be considered. Boiler system ph should be 8.08.6. An antifreeze can be utilized in areas where freezing could occur. Automotive or silicatebased antifreeze cannot be used. Use only anti freeze approved for heating systems. Using antifreeze can cause a loss in heating efficiency and some heating components within the system could be negatively impacted. System Plumbing For the heating system piping, it is possible to use either copper or iron piping materials. The supply and return pipe should be insulated to avoid heat loss. In systems where plastic tubing is used, it must have an oxygen diffuser barrier. If nonoxygen barrier tubing is used, the boiler must be separated from the tubing by a heat exchanger. A thermostatic mixing valve, set to open at 40 ºF (60 ºC), is required to temper return water to prevent cold return water from reaching the boiler. This valve helps prevent boiler corrosion. Boiler Accessories Ash Hoe Ash Pan Barometric Damper Termovar Mixing Valve Automatic Feed Device 5