INSTRUCTION BULLETIN

Similar documents
JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Service Bulletin Trucks Date Number Page

TECHNICAL INSTRUCTIONS

JOHN DEERE X465, X475, X485, X495, X575, X585

TECHNICAL INSTRUCTIONS

TOOLS REQUIRED: Crimping tool A/C Recovery Unit Wrench set up to 1 ¼ 4 Hole saw

Heater Core Replacement

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

2002 Dodge Caravan SE

INSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS

MOUNTING INSTRUCTIONS

Do not open the cooling system while it is hot or while the engine is running.

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

When checking the vehicle for DTCs, the ECM may report one or more of the following DTCs set as current or in history: P0442, P0446, P0449 or P0455.

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

DISTRIBUTION > HOUSING, HVAC > INSTALLATION > AIR INLET HOUSING

600 Floor Stripper Applicator

Engine Block Heater Service Kits (Tank Type) ROZJ 6076T and 6076A (John Deere Powered Standby Generator Sets)

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

MOUNTING INSTRUCTIONS

Operating Instructions

HEATING AND AIR CONDITIONING

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

186E. MM160 Rev. 12 (12 95)

ADD FLUID 300 NDNL 300 CT 300 OC 700 NDNL 725 NDNL 950 NDNL

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

T15 Product Guide UNCOMPROMISED INDUSTRIAL-STRENGTH PERFORMANCE TO CLEAN BOTH OPEN AREAS AND TIGHT SPOTS PRODUCT HIGHLIGHTS KEY PRODUCT ENHANCEMENTS

OPERATION MANUAL VCX-4 Vacuum Coolant Exchanger

V-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17)

Service Bulletin

Document ID: The EVAP canister vent solenoid (CVS) valve draws fresh air into the system through a vent.

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

BC BRONCOS AIR CONDITIONING UNIT

CABS/BLADES/ SPREADERS/ACCESSORIES

OPERATIONAL & MAINTENANCE MANUAL For SEM Model 0101 HD Crusher Serial Numbers: 1010 thru 1057

TECHNICAL INSTRUCTIONS

Heater with Air Conditioning. E-Series Ford Aeromaster

This site is based on a but applies to all 1971-on Saab 99 and Saab 900.

INSTALLATION INSTRUCTIONS

DRAIN WATER TEMPERING INSTALL

Trouble Shooting and Help Guide TT / TTB 1840

HEATING. Additional heating

PUMP OWNERS MANUAL. ProVac 3 PUMP

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V

TECHNICAL INSTRUCTIONS

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

1350 & AMMCO Brake Washer Systems. Installation and Operating Instructions With Safety and Maintenance Instructions and Parts Identification

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Product Support Bulletin

Symphony Plus Pressurized Water Sanitizing Kit P/N

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

Parts List. RevA _85609INST

Thermo-Bob 4 Installation Manual KT5A Kit

Sleeper Heater and Air Conditioner, Blend Air System 83.05

Trooper Portable Carpet Extractor. Operator and Parts Manual. Model No.: Can Rev. 00 (09-99)

RAYPAK REPLACEMENT INSTRUCTIONS

TECHNICAL INSTRUCTIONS

I had to remove front splash shield to drain the radiator.

Sedan Range. Remove and destroy Bulletin 14-13, amended 10/97. Replace with this Bulletin. Revised text is marked with a bar and in bold text.

INSTALLATION INSTRUCTIONS

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST FORD TRUCK

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

REMOVE AND INSTALL AIR CLEANER ASSEMBLY

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

Cordless Electric Broom

SECTION AUXILIARY HEATER

Service Bulletin

Installation Instructions 36 Inch Refrigerator

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

OPERATING & MAINTENANCE MANUAL

PORTABLE KEROSENE HEATER OPERATION AND MAINTENANCE INSTRUCTIONS. Model RCA-2800

HVAC Module Assembly Replacement. Tools Required. J A Halogen Leak Detector. Removal Procedure

INSTALLATION INSTRUCTIONS FOR ACCESSORY COMBUSTION AIR INLET FILTER KIT FOR ULTRA HIGH EFFICIENCY WATER HEATERS (PART# ) KIT CONTENTS:

Heat Exchanger Block Replacement Instructions

SERVICE BULLETIN A

Media Service Instructions 1500 Series BAT Media Plants

Dirt and dust intrusion into the EVAP canister vent hose assembly, resulting in restricted air flow, may cause this condition.

1 of 8 5/11/17, 10:01 AM

REVISED AIR GOVERNOR LINES CX AND CH MODEL CHASSIS WITH ASET AC ENGINE

BMW E36 Thermostat Removal And Coolant Flush

G-10f/GCG-10f UPRIGHT COOLER

55-Gallon Dispenser Package


Dyna-Star HP, HF, 10:1 Pumps: 120# and 400# Drum Cover and Follower Plate

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter. EcoWater Systems Poland

Installation Manual Chevrolet Vehicles

SAN JUAN FRESH WATER COOLING SYSTEMS

ADVISORY. Recommendation: Air trapped in the cooling system can cause cavitation which may be damaging to some system components.

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

Installation Manual Mopar Engine Compartment Upgrade Kit

Installation, Operating, and Maintenance Manual

INSTALLATION & OWNER S MANUAL

MICRO CLEANER. OPERATOR MANUAL Advance MODEL /10 Rev E Document Number

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

Item # /2" NPT, 2 STAGE AIR FILTER/DRYER SYSTEM INSTRUCTIONS

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 2021 BEF33H & BEF40H ELECTRIC FIREPLACE

SUBJECT: NO: Rev. B No Restart/Rough Idle After A Hot Soak GROUP: Vehicle Performance. DATE: Jun. 12, 1998

Transcription:

INSTRUCTION BULLETIN No. 340853 Machine: M20 / T20 Published: 12-2015 Rev. 03 NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the Parts List in the appropriate place in the machine manual for future reference. Retaining the Parts List will make it easier to reorder individual parts and will save the cost of ordering an entire kit. NOTE: Numbers in parenthesis ( ) are reference numbers for parts listed in Bill of Materials. Installation instructions for kit number 9003455 SYNOPSIS: This kit contains the parts needed to replace scrub vacuum fan assembly on M20 (Serial Numbers 000000-006877) and T20 (Serial Numbers 000000-005892) machines. Please follow step-by-step instructions. SPECIAL TOOLS / CONSIDERATIONS: (Estimated time to complete: 3.5 hours) 1. Thoroughly clean outside of hydraulic components before disconnecting hydraulic hoses or fittings and flush hoses and fittings with air, solvent, or hydraulic fluid and cap disconnected hoses or open ports to prevent contaminants from entering system. 2. Mark hydraulic hoses with locations of where they are attached. Markings make it easier to reconnect hoses to proper locations. 3. Discard all hydraulic fluid drained from the system. Use only new approved hydraulic fluid to replenish hydraulic reservoir. Hydraulic fluid is potentially dangerous to the environment. Obey all federal, state, and local laws/regulations governing the disposal of environmentally hazardous materials when disposing hydraulic fluid. PROTECT THE ENVIRONMENT Please dispose of packaging materials, used machine components such as batteries and fluids in an environmentally safe way according to local waste disposal regulations. Always remember to recycle. PREPARATION: 1. Park the machine on a clean level surface and engage the parking brake. FOR SAFETY: Before leaving or servicing machine, stop on level surface, turn off machine, and remove key. 2. Disconnect the battery cables from the batteries. WARNING: Always disconnect battery cables from machine before working on electrical components. NOTE: Do not discard removed parts unless instructed to do so. Most parts are reinstalled after the scrub vacuum fan is replaced. 3. Remove the engine cover from the machine. Set the engine cover aside. IB 340853 (12-2015) 1

4. Remove the coolant reservoir from the bracket and move the reservoir away from the scrub vacuum fan. (Fig. 1) NOTE: If necessary, unplug spark plug cables before moving the coolant reservoir. INSTALLATION: 1. M20 machines serial numbers 000000-002699 only: Disconnect both steel tubes from the lower valve. (Fig. 3) FIG. 1 5. Remove the hardware holding the air cleaner bracket to the machine and move the air cleaner/air cleaner bracket away from the scrub vacuum fan. (Fig. 2) FIG. 3 2. Disconnect the hose attached to location P1 on the scrub valve. (Fig. 4) FIG. 4 FIG. 2 6. Drain hydraulic fluid from the system. NOTE: It is not necessary to drain hydraulic fluid if a hydraulic vacuum is used to vacuum down the hydraulic system. 3. Disconnect all main wire harness leads from the scrub valve. 4. Remove the support bracket. Set the support bracket and hardware aside. (Fig. 5) FIG. 5 2 IB 340853 (12-2015)

5. Loosen the hardware holding the scrub valve bracket to the solution tank. (Fig. 6) 8. Disconnect the four hydraulic hoses (A), (B), (C), and (D) from the fittings on the scrub fan motor. (Fig. 9) A B D C Scrub Fan Motor FIG. 6 6. Lift the scrub valve assembly up from the hardware and away from the solution tank. (Fig. 7) FIG. 9 NOTE: If working on an LP machine, the fuel tank can be removed to make access to scrub vacuum fan easier. Refer to Operators Manual for instructions how to remove LP tank. NOTE: If working on a diesel or gasoline machine without FaST, ES, or spray hose options, the operator station removable panel can be removed to make access to scrub fan easier. Set the panel and hardware aside. (Fig. 10) FIG. 7 7. Disconnect the intake hose from the sweep fan. Move the intake hose away from the scrub vacuum fan. Set the hose clamp aside. (Fig. 8) FIG. 10 FIG. 8 IB 340853 (12-2015) 3

9. Remove the hardware holding the scrub vacuum fan to the solution tank. Set the hardware aside. (Fig. 11) Set aside Solution Tank Set aside FIG. 11 10. Disconnect the hose from the scrub vacuum fan. Set the hose clamp aside. (Fig. 12) FIG. 12 11. Remove the scrub vacuum fan from the machine. (Fig. 12) 4 IB 340853 (12-2015)

2 NOTE: Do Not remove hydraulic motor from scrub vacuum fan. Hydraulic motor is enlarged / shown off scrub vacuum fan to show orientation / locations of hydraulic fittings 5 4 3 Saved clamp Saved hardware 1 Solution Tank FIG. 13 12. Remove the plugs from the new scrub vacuum fan (1) motor. (Fig. 13) 13. Install the straight fitting (5) into the vacuum fan (1) motor. (Fig. 13) 14. Install the t- fitting (2) into the straight fitting (5) installed into the scrub vacuum fan (1) motor. Do not completely tighten t- fitting. The t- fitting is tightened during later adjustment. (Fig. 13) 19. Hold hydraulic hoses (A) and (B) to the t- fitting (10) installed on the hydraulic motor (1) and note distance t- fitting must be adjusted for hose installation. (Fig. 14) A 2 B 15. Install the 90_ fitting (4) and 45_ fitting (3) into the scrub vacuum fan (1) motor. Note orientation of both fittings on the hydraulic motor. (Fig. 13) D 1 16. Place the new scrub vacuum fan (1) where the old scrub vacuum fan was previously installed. (Fig. 12 / Fig. 13) 17. Clamp the vacuum hose onto the scrub vacuum fan (1). (Fig. 12 / Fig. 13) 18. Use the saved hardware to install the scrub vacuum fan (1) onto the solution tank. (Fig. 13) C FIG. 14 20. Adjust the t- fitting (10) as necessary to connect hydraulic hoses (A) and (B). (Fig. 14) 21. Connect hydraulic hoses (A), (B), (C), and (D) to the scrub fan motor (1). (Fig. 14) IB 340853 (12-2015) 5

22. Reconnect the intake hose to the sweep fan. (Fig. 15) 25. Reconnect both steel tubes to the lower valve. (Fig. 18) FIG. 15 23. Reinstall the scrub valve assembly onto the solution tank. (Fig. 16) FIG. 18 26. Reconnect the main wire harness leads to the scrub valve. 27. Reinstall the support bracket. (Fig. 19) FIG. 16 24. Reconnect the hose removed from location P1 on the scrub valve. (Fig. 17) FIG. 19 28. Reinstall the air cleaner assembly/air cleaner assembly bracket onto the machine. (Fig. 20) FIG. 17 FIG. 20 6 IB 340853 (12-2015)

29. Reinstall the coolant reservoir onto the bracket. (Fig. 21) 30. If hydraulic fluid was drained to install this kit, replenish the hydraulic system with Tennant approved hydraulic fluid. Refer to the Operators Manual for additional information. 31. Reinstall the LP tank, operator station removable panel, and other parts/ components removed to install the new vacuum fan assembly onto the machine. 32. Reconnect the battery cables to the battery. FIG. 21 33. Start and test the machine. Observe the scrub vacuum fan and other hydraulic components that had fittings / hoses removed / replaced for leaks. Run the scrub vacuum fan to ensure it operates. Bill of Materials for Fan Kit, Scrub, Replmt [M20 & T20] - 9003455 Ref. Tennant Part No. Description Qty. o 9003455 ) Fan Kit, Scrub, Replmt [M20 & T20] 1 Y 1 1022559 Housing Wldt, VacFan, Rear 1 Y 2 76315 Fitting, Hyd, Tee, JF08/JM08/JM08, Br 1 Y 3 47513 Fitting, Hyd, E45, JM08/OM10 1 Y 4 77098 Fitting, Hyd, E90, JM06/OM04 1 Y 5 56692 Fitting, Hyd, Str, JM08/OM10 1 TENNANT COMPANY P. O. Box 1452 Minneapolis, MN 55440-1452 IB 340853 (12-2015) 7