Condensate Boiler Feed Water Make-Up

Similar documents
Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

5. CONDENSATE PUMPS/UNITS

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

FLANGE-MOUNT CENTRIFUGAL PUMPS

Hoffman Specialty Pump Products

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Stainless Steel Condensate Return Units

SECTION STEAM CONDENSATE PUMPS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

SECTION STEAM CONDENSATE PUMPS

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

FEATURES. Other Fed-Flush Arrangements

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

SECTION STEAM CONDENSATE PUMPS

INTRODUCTION 09/'16 SUPSD 06/'15

Domestic Pump Condensate Transfer Equipment

DUPLEX CONDENSATE TANK SYSTEM

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

4600 SERIES. Technical Specifications. Condensate Units - Steel Tank. Features

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

BuildingName The Description of the Project P DOCUMENTS

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

JCseries EVAPORATIVE CONDENSER. engineering data

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

Wilo IL Vertical Split-Coupled Inline Pumps

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

.005 ATMOSPHERIC DEAERATOR

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

DEAERATORS .005 ATMOSPHERIC DEAERATOR

CLOSED COUPLED CENTRIFUGAL PUMPS

Deaerator. Specifications

TECHNICAL. Series 18. Pump Packages

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

TYPE POS Oil Shield Sump Pump

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

.03 ATMOSPHERIC DEAERATOR

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Indirect Gas-Fired Make-Up Air

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

380 Series Multi-Stage Centrifugal Pumps

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service

SECTION AIR COMPRESSORS AND ACCESSORIES

6-30 Vertical Deep Well. Close Coupled Vertical Turbine Submersible Turbine. Pump Type. Application. Description. Materials

SECTION FIRE PUMP AND CONTROLS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Mission Critical. Fuel Supply Systems

PIONEERS IN AIR VACUUMS

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

Industrial. Solutions brands you trust. Product Overview

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

1900 Series In-Line Pump

Our Purifier systems

Boiler & Water Heater

Direct Gas-Fired Make-Up Air

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Silhouette. Feedwater Heater. Boiler Feedwater

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

RHP120 RHP300 Steam Boiler Series

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

SECTION PLUMBING EQUIPMENT

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Custom Design TYPE CS

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

TM Series. Induced Draft, Counter Flow Optional Accessories

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

FT900BD FLIGHT-TYPE DISHWASHER

SECTION AIR COOLED WATER CHILLERS

Standard Features. Performance/Capacities

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

Pumps SELECTION OF A PUMP

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Models. Options. Standard Features. LoH 2 O

.2 Section Waste Management and Disposal.

Full-line Product Overview

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Polymer Dilution Blend and Feed Specifications For General Use

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Paragon. Induced Draft, Counter Flow Optional Accessories

Transcription:

1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 Low Inlet Condensate Receiver (7 from floor) Close Grained Cast Iron Simplex and Duplex Design To 0,000 SQ-Ft EDR Pump Capacity to GPM Pressure to 50 PSI Vertical Pump Configuration Receiver Sizes to gallon Temperature to 50 Degree F Individual Float Control or Mechanical Alternating Motors in ODP or TEFC Enclosure Single or Three Phase Power Condensate Boiler Feed Water Make-Up Cast Iron basins are free standing design no bolt down hole connections. Receivers available in round or square configuration. Can be provided with Simplex or Duplex Control Panels mounted to the receivers with motors and float controls wired to the Control Panel provided.

1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 NEMA 1 or NEMA 4 Float Controls Simplex or Duplex Arrangement Mechanical Alternating Switch Available Cast Iron Elevated Float Stand Stainless Steel Float Bulb Stainless Steel Float Rods and Float Stops. Gasket bolt down connections to cast iron tank. Low suction inlet connection to service difficult installations. Vented condensate tank. Optional inlet strainers available. Cold water make-up valve with air gap fitting available for boiler feed or water makeup systems. Optional sight gauge glass and thermometer available VCL Series provides an innovative approach to difficult installations where condensate collection requires low tank connections without compromising pump performance. Motors in ODP or TEFC Construction. Stainless Steel Pump Shaft connected to Pump Motor through ridged steel bolted coupling. Oil lubricated bronze bearing with spring loaded oil cap. Cast Iron bronze fitted pump construction with lower mechanical seal and upper shaft seal assemblies. Integral vertical case assembly with threaded discharge connections. Lower drain connection for condensate tank.

1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 CONVERSION TABLES Multiply By To Get BHP (Boiler Horsepower) 34.5 Lbs./Hr of Steam at 1 F BHP (Boiler Horsepower) 0.069 GPM Water BHP (Boiler Horsepower) 33,479 BTU/Hr Lbs./Hr Steam 0.00 GPM Water Lbs./Sq. In.7 Feet of Water Feet of Water (Head) 0.4335 Lbs./Sq. In Cubic Feet of Water 7.48 Gallons of Water Cubic Feet per Minute 6.43 Lbs. of Water/Minute Cubic Feet per Minute 448.8 Gallons per Hour Heating Water with Steam How many Lbs. per hour of steam is need to heat 60 gallons per minute flow rate of water from 60 F to 180 F? Lbs./Hr= 60 * (180-60) Lbs./Hr= 60 * (10) Lbs./Hr= 700 Lbs./Hr= 3600 Sizing a Boiler Feed Pump Receiver The receiver tank should be able to hold five minutes worth of condensate for boilers up to 00 BHP and minutes of condensate for boilers over 00 BHP. An additional 33 percent should be added as a safety factor. One BHP (Boiler Horsepower) will produce.069 gallons per minute of condensate. Developing a formula results in: BHP x.069 x minutes of storage x 1.33 = Receiver size, in gallons Examples: 0 BHP Boiler 0 x 0.69 x 1.33 = 68.83 gallons Select an available receiver tank equal to or larger than 68.8 gallons. (Probably a 70-gallon tank will be the standard commercially available tank.) 50 BHP Boiler 50 x.069 x x 1.33 = 367.1 gallons

July 0 New Catalogue Release Bulletin 9C.01 Conversion Factors and Equivalent Data Sizing Steam Condensate and Boiler Feed Pumps Boiler H.P. MBH SQ. FT.EDR Lb./Hr Steam Cond. Actual GPM Cond. Boiler H.P. MBH SQ. FT.EDR Lb./Hr Steam Cond. Actual GPM Cond. 66.95 80 70 0.14 5 1740.7 780 180 3.64 4 133.9 560 140 0.8 54 1807.65 7560 1890 3.78 6 00.85 840 0.4 56 1874.6 7840 1960 3.9 8 67.8 110 80 0.56 58 1945 810 0 4.06 334.75 1400 350 0.7 60 008.5 8400 0 4. 1 401.7 1680 40 0.84 6 075.45 8680 170 4.34 14 468.65 1960 490 0.98 64 14.4 8960 40 4.48 16 535.6 40 560 1.1 66 09.35 940 3 4.6 18 60.55 50 6 1.6 68 76.3 950 380 4.76 0 669.5 800 700 1.4 70 343.5 9800 450 4.9 736.45 80 770 4 7 4. 080 50 5.04 4 803.4 3360 840 1.68 74 477. 360 590 5.18 6 870.35 3640 9 1.8 76 544.1 640 660 5.3 8 937.3 390 980 1.96 78 611.05 90 7 5.46 04.5 400 50.1 80 678 1100 800 5.6 3 71. 4480 110.4 8 744.95 11480 870 5.74 34 1138. 4760 1190.38 84 811.9 11760 940 5.88 36 105.1 5040 160.5 86 878.85 1040 6.0 38 17.05 530 13.66 88 945.8 130 80 6.16 40 1339 5600 1400.8 90 1.75 1600 3180 6.3 4 1405.95 5880 1470.94 9 79.7 1880 30 6.44 44 147.9 6160 40 3.08 94 3146.65 13160 390 6.58 46 39.85 6440 16 3. 96 313.6 13440 3360 6.7 48 1606.8 370 1680 3.36 98 380.55 1370 34 6.86 50 1673.75 7000 1750 3.5 0 3349.3 14000 3500 7 Pump BHP=( Flow) X (Head in Feet) X (S.G.) (3960) X(Pump Efficiency) 1 SQ.FT. E.D.R. = 40 BTUH @ F 1 Boiler H.P. = 33493 BTU/Hr Example: Pump rating GPM at PSI with pump efficiency of 58% at that design condition. Fluid is water. ( GPM) X ( PSI) X (.31 /PSI) X ( 1.0 S.G.) (3960) X (.58) BHP= 0.91 Pump BHP at design condition

1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 Unit No. Max. Sq.- Ft Direct Radiation Equivalent Boiler HP Radiation will Condense GPM Pump Capacity GPM Discharge Pressure PSI Motor HP 3450 RPM Receiver Gallons Simplex Receiver Gallons Duplex VCL-1 10 1 140 0 00 00 00 00 00 7. 7. 7. 7. 7. ½ ½ ½ ½ ½ 0 40 50 0.75 1.0 VCL- 0 40 50 000 000 000 000 000 14.5 14.5 14.5 14.5 14.5 1 1 1 1 1 3.0 3.0 3.0 3.0 3.0 0 40 50 0.75 1.0 VCL-4 40 4 440 450 4000 4000 4000 4000 4000 9.0 9.0 9.0 9.0 9.0 6.0 6.0 6.0 6.0 6.0 0 40 50 0.75 1.0 VCL-6 60 6 640 650 6000 6000 6000 6000 6000 43.0 43.0 43.0 43.0 43.0 3 3 3 3 3 9.0 9.0 9.0 9.0 9.0 0 40 50 0.75 1.0 VCL-8 80 8 840 850 8000 8000 8000 8000 8000 58.0 58.0 58.0 58.0 58.0 4 4 4 4 4 1.0 1.0 1.0 1.0 1.0 0 40 50 0.75 1.0 VCL- 0 40 50 000 000 000 000 000 7.0 7.0 7.0 7.0 7.0 5 5 5 5 5.0.0.0.0.0 0 40 50 0.75 1.0 VCL- 0 40 000 000 000 000 8.0 8.0 8.0 8.0 7.5 7.5 7.5 7.5.5.5.5.5 0 40 0.75 1.0 VCL-0 00 0 040 0000 0000 0000 0000 144.0 144.0 144.0 144.0.5.5.5.5 0 40 0.75 1.0 PUMP SELECTION: 3450 RPM

Total Dynamic Head (TDH) in Feet 0 0 40 50 60 70 80 90 0 10 1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 5 3/8... 4 7/8 4 1/ PUMP SELECTION: 3450 RPM Model: VCL 3450 RPM Discharge: 5-3/8 -CC--0 4 7/8 -CC--0 4 1./ -CC--75 3 7/8 -CC--50 3 5/8 -CC--50 3 7/8 3 5/8 0 5 0 5 35 40 Capacity in Gallons per Minute Convert PSI to TDH: PSI X.31= Feet Head PSI = 69.3 TDH Convert HP to kw: HP X 0.746 Convert Watts to Amps Motor Amps: General Guideline 1HP= 0.746 kw=746 Watts 1 HP X 746 W/Voltage= 1V= 6.5 Amps 08V= 3.6 Amps V= 3. Amps 460V= 1.6 Amps HP 1V 08V V 460V 1/3.1 1. 1.1 0.55 1/ 3. 1.8 1.6 0.8 3/4 4.9.8.5 1.3 1 6.5 3.6 3. 1.6 1 1/ 9.8 5.6 5.0.5 Note: Refer to electric motor manufacturer nameplate for exact information.

1144 Utica Ave, Brooklyn, NY 1103 PUMP SELECTION: 1750 RPM July 0 New Catalogue Release Bulletin 9C.01 Unit No. Max. Sq.- Ft Direct Radiation Equivalent Boiler HP Radiation will Condense GPM Pump Capacity GPM Discharge Pressure PSI Motor HP 3450 RPM Receiver Gallons Simplex Receiver Gallons Duplex VCL-1-4 VCL--4 VCL-4-4 VCL-6-4 VCL-8-4 VCL--4 00 000 4000 6000 8000 000 7. 14.5 9.0 43.0 58.0 7.0 ½ 1 3 4 5 3.0 6.0 9.0 1.0.0 ¼ ¼ ¼ ¼ ¼ ¼

1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 Standard Duplex Unit provided with () float switches (1 per pump) 1 ¼ DISCHARGE 1 ¼ DISCHARGE Notes: 1. VCL Condensate unit not provided with bolt down holes. Weight of unit holds it in place.. Duplex VCL units provided with individual float switches. If mechanical alternating float switch selected, second float cover will be provided with blank plate. 3. Refer to separate dimensional print if control panel mounted and wired to receiver.

1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 8 5/8 1 ¼ DISCHARGE 1 ¼ DISCHARGE 1 ¼ DISCHARGE Notes: 1. VCL Condensate unit not provided with bolt down holes. Weight of unit holds it in place.. Duplex VCL units provided with mechanical alternating float switch as standard. If required with individual float switches ensure control panel is provided with 4 hour alternator to provide lead/lag cycle time load sharing. 3. Refer to separate dimensional print if control panel mounted and wired to receiver.

1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 Duplex Control Panel Mounted 8 5/8 Mounted and Wired Duplex Control Panel 1 ¼ DISCHARGE 1 ¼ DISCHARGE 1 ¼ DISCHARGE Notes: 1. VCL Condensate unit not provided with bolt down holes. Weight of unit holds it in place.. Duplex VCL units provided with mechanical alternating float switch as standard. If required with individual float switches ensure control panel is provided with 4 hour alternator to provide lead/lag cycle time load sharing. 3. Refer to separate dimensional print if control panel mounted and wired to receiver.

July 0 New Catalogue Release Bulletin 9C.01 D-100 Duplex Controls with Mechanical Alternating Float H O A L1 Individual Disconnect Switches-Fused SWITCH 1 1 O M1 OL1 L1 L L3 L1 L L3 H A L SWITCH 3 4 M OL PR PR PR PR PR T1-0VA 440/10 M1 M OL1 s s s OL s s s Federal Pump: D-100 Individual Fused Disconnect 10 V Control Transformer Across- the-line magnetic starters Starter Overload protection HOA Selector Switches Pump Run Lights PUMP 1 PUMP September 014 Revision 11

July 0 New Catalogue Release Bulletin 9C.01 D-100 Duplex Controls with Mechanical Alternating Float Single Fused Disconnect Individual Pump Fused Disconnects 8 * H-O-A H-O-A H-O-A H-O-A 1 P-1 RUN P- RUN P-1 RUN P- RUN 8 Federal Pump: D-100A Single Fused Disconnect 10 V Control Transformer Across- the-line magnetic starters Starter Overload protection HOA Selector Switches Pump Run Lights Federal Pump: D-100B Individual Fused Disconnect 10 V Control Transformer Across- the-line magnetic starters Starter Overload protection HOA Selector Switches Pump Run Lights NEMA 1 NEMA 7 NEMA 4 *Dimensions are approximate only and may vary based upon additional options or enclosure specified. For certified dimensions, contact the Factory prior to approval. September 014 Revision 1

July 0 New Catalogue Release Bulletin 9C.01 Suggested Specifications Duplex Condensate Unit Furnish and install where shown in the plans a Federal Pump Model VCL low suction inlet connection Duplex condensate unit with each pump rated as shown in the equipment schedule or as highlighted in the plans. The entire unit including float switch assembly and controls shall be factory assembled and pre-wired and supplied as a single unit. Inlet connection will not exceed 7 from the floor. Each Duplex condensate unit shall include () vertical mounted cast iron bronze fitted pump assemblies with lower and upper shaft mounted mechanical seals suitable for degree F condensate liquid collection and transfer. Pump shall include oil lubricated bronze shaft mounted bearing and be connected the vertical motor with steel bolt on coupling assembly. Pump shaft shall be stainless steel construction. Pumps shall be centerline discharge top pull out design to permit removal of the pump assembly from the cast iron receiver. Electric motors shall be connected to vertical pump support assembly and connected to the pump shaft with solid steel couplings. Motor enclosure shall be ODP (or as shown in the plans) with Class B Insulation and provided with 1. service factor. Cast iron receiver will be free standing design constructed of close grain cast iron, seamless and contain no welded connections. Receivers shall include a single drain connection (to be piped by the contractor to the waste drain) and single inlet connection. Contractor will provide an inlet strainer bolted to the receiver inlet connection. Receiver will be provided with a vent connection. Contractor will pipe the vent connection as shown in the plans. The condensate unit will include a receiver mounted mechanical alternating float switch provided with stainless steel float rods and stops and stainless steel float ball that will control the operation of the pumps based upon the liquid level in the receiver. The mechanical alternating float switch will initiate lead and lag pump operation and sequence lead/lag operation between the pumps upon completion of each pump cycle to ensure even pump wear. Float switch shall be Square D or equal. Pump manufacturer will provide sight gauge glass and externally mounted thermostat to allow visual indication of tank water level and condensate temperature. Provide receiver mounted Duplex Level Control Panel; Federal Pump model D-100 to include individual fused disconnect switches, across-the-line-type magnetic starters with overload protection, pump run lights, HOA selector switches, 1 fused secondary control circuit transformers (for 3 phase voltages), numbered wiring and terminal strip and provided in NEMA 1 enclosure. Control Panel will be UL508 approved. Pump manufacturer will mount and wire the control panel and connect motors and float switches providing automatic operation once installed. Duplex Unit will be tested by the pump manufacturer prior to shipment. Pump manufacturer will provide equipment start-up assistance and verify the unit is installed according to the Pump Manufacturer s requirements. Optional: Pump manufacturer will provide high water alarm float switch contact option that will identify high water alarm and signal alarm condition to remote area. Provide dry contacts in the Duplex Condensate Control Panel for pump operation and high water alarm condition for remote monitoring.

July 0 New Catalogue Release Bulletin 9C.01 Suggested Specifications Simplex Condensate Unit Furnish and install where shown in the plans a Federal Pump Model VCL low suction inlet connection Simplex condensate unit with the pump rated as shown in the equipment schedule or as highlighted in the plans. The entire unit including float switch assembly and controls shall be factory assembled and pre-wired and supplied as a single unit. Inlet connection will not exceed 7 from the floor. Each Simplex condensate unit shall include (1) vertical mounted cast iron bronze fitted pump assemblies with lower and upper shaft mounted mechanical seals suitable for degree F condensate liquid collection and transfer. Pump shall include oil lubricated bronze shaft mounted bearing and be connected the vertical motor with steel bolt on coupling assembly. Pump shaft shall be stainless steel construction. Pump shall be centerline discharge top pull out design to permit removal of the pump assembly from the cast iron receiver. Electric motor shall be connected to vertical pump support assembly and connected to the pump shaft with solid steel couplings. Motor enclosure shall be ODP (or as shown in the plans) with Class B Insulation and provided with 1. service factor. Cast iron receiver will be free standing design constructed of close grain cast iron, seamless and contain no welded connections. Receivers shall include a single drain connection (to be piped by the contractor to the waste drain) and single inlet connection. Contractor will provide an inlet strainer bolted to the receiver inlet connection. Receiver will be provided with a vent connection. Contractor will pipe the vent connection as shown in the plans. The condensate unit will include a receiver mounted float switch provided with stainless steel float rods and stops and stainless steel float ball that will control the operation of the pumps based upon the liquid level in the receiver. The float switch will initiate pump operation. Float switch shall be Square D or equal. Pump manufacturer will provide sight gauge glass and externally mounted thermostat to allow visual indication of tank water level and condensate temperature. Provide receiver mounted Simplex Level Control Panel; Federal Pump model S-00 to include fused disconnect switch, across-the-line-type magnetic starter with overload protection, pump run light, HOA selector switch, 1 fused secondary control circuit transformers (for 3 phase voltages), numbered wiring and terminal strip and provided in NEMA 1 enclosure. Control Panel will be UL508 approved. Pump manufacturer will mount and wire the control panel and connect motor and float switch providing automatic operation once installed. Simplex Unit will be tested by the pump manufacturer prior to shipment. Pump manufacturer will provide equipment start-up assistance and verify the unit is installed according to the Pump Manufacturer s requirements. Optional: Pump manufacturer will provide high water alarm float switch contact option that will identify high water alarm and signal alarm condition to remote area. Provide dry contacts in the Simplex Condensate Control Panel for pump operation and high water alarm condition for remote monitoring.

No Description Required Material Impeller 1 Bronze 9 Mechanical Shaft Seal 1* Various Cap Screw Steel VCL Replacement Part Kits MARCH 0 Replacement Part Kits VCL Condensate Units Page VCL- Replaces Section: 1 Dated: February 001 A Cap Screw Steel D Cap Screw Steel 33 Shaft 1* Stainless Steel 38 Suction Plate 1 Cast Iron 40 Coupling 1* Steel 46B Set Screw 4* Steel 46D Impeller Set Screw 1 Steel 49 Shaft Seal 1* Various 51 Casing Assembly 1 Cast Iron 59 Lower Bearing 1* Bronze 67 Set Screw 1* Steel 71A Float Switch 1* Various 7 Float Rod and Stops Set* Stainless Steel 73B 0 46B 73B Float Switch Pedestal 1 Cast Iron 74A Stuffing Box & Guide Pipe Set Various 75 75 Float 1* Stainless Steel 76 Receiver 1 Cast Iron 77 Gasket * Rubber 3 Cover 1 Cast Iron 1 Motor 1 Various 141 Oil Cup 1 Steel 46D 0 Motor Bolts Steel Repair Items Included Repair Items Included Repair Items Included Gasket Kit Seal Kit 77 + A 9,49 + Gasket Kit Bearing Kit Seal Kit + 59 + 141 Motor Kit: 1/3HP-3500RPM 00-/460V- 3Phase-ODP Motor Kit: 3/4HP-3500 RPM 00-/460V -3 Phase-ODP 1 + 40+ 46B + Motor Bolts 1 + 40+ 46B + Motor Bolts Float Switch Kit 71A + 7 Float Rod Kit 67 + 74A +7 Impeller Kit 46D+ + Bearing Kit Shaft Kit Bearing Kit +33 Casing Kit Motor Kit: 1/4HP-1750 PRM 1V/1Phase-ODP Motor Kit: 1/3HP-3500RPM 1V/1Phase-ODP Motor Kit: 3/4HP-3500 RPM 1V/1Phase-ODP Motor Kit: 1HP-3500RPM 1V/1 Phase Motor Kit: HP-3500RPM 1V/1 Phase 3/17/0 51 + 38 +141+ Bearing Kit 1 + 40+ 46B 1 + 40+ 46B 1 + 40+ 46B 1 + 40+ 46B 1 + 40+ 46B Motor Kit: 1HP-3500RPM 00-/460V -3 Phase-ODP Motor Kit: HP-3500RPM 00-/460V -3 Phase-ODP Motor Bearing Kit ¼ HP Motor Bearing Kit: 1/3 HP Motor Bearing Kit: ½ HP Motor bearing Kit: ¾ HP Motor bearing Kit: 1 HP Motor bearing Kit: HP 1 + 40+ 46B + Motor Bolts 1 + 40+ 46B + Motor Bolts Motor bearing + Coupling Motor bearing + Coupling Motor bearing + Coupling Motor Bearing + Coupling Motor Bearing + Coupling Motor Bearing + Coupling Float Ball Kit Float Stand 75 + Gasket Kit 73B + Gasket Kit Float Guide Pipe Kit 67 + 74+ 7 + Gasket kit Receiver: Gal Cast Iron Receiver: Gal Cast Iron Receiver: Gal Cast iron Replacement Pump Kit 76 + Gasket Kit +3 76 + Gasket kit +3 76 + Gasket Kit + 3 Assembled pump only!

VCL Replacement Part Kits MARCH 0 Replacement Part Kits VCL Condensate Units Page VCL-1 Replaces Section: 1 Dated: February 001 Federal Pump Replacement part kits are designed to provide the end user with factory authorized replacement parts that meet design specifications ensuring proper pump performance. These kits include the accessory and support components to ensure those required repair are addressed properly and included in each kit. Use only Factory Authorized and supplied original replacement parts when repairing the installed Federal Pump. Repair Issue Leaking Seal Failed Pump bearing Leaking Receiver Wobbly pump shaft Bent Float Rod Lack of Pressure Erosion Motor Failure Noisy Motor Loss of Float Control Damaged float Damaged receiver Damaged Coupling Replacement Pump Kit Required Mech Seal Kit Bearing Kit-Pump Gasket Kit Shaft Kit Float Rod Kit Impeller kit Casing Kit Motor Kit Bearing Kit-Motor Float Switch kit Float Kit Receiver kit Coupling Kit Pump Kit Seal Kit: Mechanical seal Upper shaft Seal Gasket Kit Gasket Kit: Pump/receiver gasket Replacement Bolts Float switch/receiver gasket Casing Kit: Lower casing Bearing Kit Coupling Float Kit: Replace Float Replacement Rod Stops Gasket kit Motor Bearing Kit: Motor Bearings Coupling Replacement Bolts Pump Bearing Kit: Seal Kit Lower pump bearing Oil bearing cap Float Switch Kit Float Switch Replacement rod stops Replacement mount bolts Shaft Kit: Pump shaft Bearing kit Coupling Receiver Kit: CI Receiver Gasket Kit Drain Plugs Impeller Kit: Bearing kit Impeller Impeller set screw Float Rod Kit Float Rod/Guide Float Stops Gasket Kit Motor Kit Replacement Pump Kit New Motor Replacement Pump New Coupling New Coupling Motor Bolts Gasket kit 3/17/0 16