RETAIL PRICE LIST. season 2017/2018 valid from: April 18, INTELIGENTNE ROZWIĄZANIA

Similar documents
OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3-1

PRODUCT CATALOG INSTALLATION CONTROLLERS ROOM REGULATORS ZONE HEATING CONTROL FLOOR HEATING CONTROL BOILER CONTROLLERS SOLAR SYSTEMS CONTROLLERS

User Manual for model

ecoal.pl V3.5 Adaptive controller Operating manual Kutno Software version:

INSTRUCTION FOR THE USER THC V E OIL BLU

ecomax 800, model R1 Boiler regulator Dzia Zintegrowanego Systemu Zarz dzania version: ec FOR SOLID FUEL-FIRED BOILERS WITH FEEDING SCREW

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Cm Pelet-set (60-90 kw)

PROGRAMMABLE 7-DAY THERMOSTAT

bruli.pl V3.5 Operating manual Kutno Software version:

prestige Control Application Supplement - ACVMax

ISO 9001 TUV CERT CE

prestige Control Application Supplement WARNING

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Control Application. Supplement - ACVMax

ST 53.1 User s manual

BIO 30, BIO 50, BIO 95

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Hydronic & HVAC Control Systems

ecomax 200 W Boiler regulator FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE:

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Operating instructions

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

prestige Control Application Supplement - Type 5 MCBA WARNING

Installation & User s Instructions

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

OPERATION MANUAL RK-2001W2 SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER. Version 9A15

BOILER CONTROLLER COMPACT

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

SOLARCOMP 951 CONTROLLER FOR SOLAR COLLECTORS

Solar controllers Energy under control

Better Design, Better Control, Better Systems.

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Field settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8

INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Boiler regulator ecomax810p3-l TOUCH

prestige Control Application Supplement - TriMax

USER'S INFORMATION MANUAL

prestige Control Application Supplement - TriMax

TECHNICAL AND OPERATIONAL DOCUMENTATION

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves

USER'S INFORMATION MANUAL

Monitoring Software for NPBC-V3M-1 User Manual

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 200

Daikin Altherma Hybrid User Guide

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

Quickheat 30 weather compensated boiler control

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL MANUAL. CENTROMETAL d.o.o. Glavna Macinec Croatia tel: ; fax :

Declaration of Conformity No. 27/2008

BeSMART Thermostat. EN Thermostat Manual

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Rozp.UE2015/ kw kw

30 radiators from one central point. Simply smarter heating. living.danfoss.com. living by Danfoss heating control

G a

VIESMANN. Operating instructions VITODENS 100-W. for the system user

FCX FUEL OIL CONDENSING BOILER RANGE

USER'S INFORMATION MANUAL

1/8. Field settings table [6.8.2] =... ID66F3. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P E

heat interface units A BOILER WITHOUT A FLAME

RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

USER'S INFORMATION MANUAL

Type summary Albatros 2

PROGRAMMABLE 7-DAY RF THERMOSTAT

REGULATOR TIS TRONIC 496P

Heating Zone Control. How to apply RESOL MX controller

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Drayton Digistat +3RF

Room-temperature (economy/night) unit TR 212 E

SPECIFICATIONS - NIKE

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Installation and servicing instructions

Technical Data Manual

English. Heating with logs & wood pellets 20-40

TERMO-Blok TERMO-Extra TERMO-Blok PTV

Boiler controller S-Tronic Plus

V. DIFFERENTIAL THERMOSTAT

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

prestige Control Application Supplement - Type 5 MCBA WARNING

Declaration of Conformity no. 56/2012

USERS GUIDE 24, 30. For installation guide see reverse of book

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER/MODULE WITH THREE STAGE ELECTRONIC CONTROL

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Transcription:

RETAIL PRICE LIST season 2017/2018 valid from: April 18, 2017 www.dksystem.pl INTELIGENTNE ROZWIĄZANIA

Boiler controllers PRODUCT NAME APPLICATION PRICE WITHOUT VAT MASTER 600 SET cat. no. 504101 MASTER 530 cat. no. 501351 Boiler temperature controller with a feeder control of the pump 2 of the circuit control of the circulation pump 3 operating as a circulation pump,return protection pump or underfloor heating pump feeder operation control control of 3 or 4 way valve adjustment of the heating temperature of two circuits on the basis of the outside temperature Boiler temperature controller with a feeder control of a P3 pump operating as a circulation pump, return protection pump or underfloor heating pump feeder operation control control of the boiler operation and domestic hot water pump acc. to one of several weekly programs 250,00 115,50 MASTER 500 cat. no. 501201 Boiler temperature controller with a feeder feeder operation control option of enabling or disabling the DHW priority control of the boiler operation and domestic hot water pump acc. to one of several weekly programs 103,00 MASTER 300 ver. 3 cat. no. 501605 EKOSTER 430 cat. no. 201907 Boiler temperature controller with a feeder* feeder operation control control of the boiler operation and domestic hot water pump acc. to one of several weekly programs *mounting box for boiler installation Boiler temperature controller (3 pumps) control of the circulation pump operation or a floor heating pump smooth fan operation and power settings temperature protection system function of protection against Legionella 104,00 93,00 EKOSTER 420 cat. no. 201905 Boiler temperature controller (2 pumps) temperature protection system smooth fan operation and power settings 80,50

Boiler controllers PRODUCT NAME APPLICATION PRICE WITHOUT VAT EKOSTER 400 cat. no. 201903 Boiler temperature controller (2 pumps) protection against overheating of the boiler protection of the installation from freezing 70,50 EKOSTER 300 ver. 3.1 cat. no. 201705 EKOSTER 200 cat. no. 201601 Boiler temperature controller* smooth fan operation and power settings option of enabling or disabling the DHW priority adjustable damping time and automatic control turn off after extinguishing of the boiler function of protecting the system against freezing and overheating *mounting box for boiler installation Boiler temperature controller smooth fan operation and power settings adjustable damping time and automatic control turn off after extinguishing of the boiler protection of the installation from freezing and overheating of the boiler 79,50 54,50 UNISTER cat. no. 201303 Electronic draught regulator maintaining the preset temperature of a boiler by controlling the air intake flap closure in case of a power failure or engine protection against overheating of the boiler air intake closure when adding the fuel to a boiler combustion supporting function using the so-called blow-bys 81,00 UNISTER DUO cat. no. 201313 Electronic draught regulator control of exhaust fan maintaining the preset temperature of a boiler by controlling the air intake flap closure in case of a power failure or engine protection against overheating of the boiler air intake closure when adding the fuel to a boiler combustion supporting function using the so-called blow-bys 84,00 CONTROL cat. no. 109011 In-room panel constant overview of the temperature measured by a regulator indication of the central heating pump operation sound alarm indicating the over temperature signaling the failure of the temperature sensor remote change of the desired temperature signalling of other parameters, depending on the controller, which actually supports the panel 20,00

DK LOGIC 100 cat. no. 105001 Room thermostat automatic room temperature control by controlling boiler, pump and valve operation built-in two factory programs and a third for individual settings two selectable temperature - day and night six heating periods per day possibility of short-term changes in heating temperature protection function of the installation against freezing possibility of manual work memorizing all the settings 31,50 DK LOGIC 200 cat. no. 106001 Wireless room thermostat automatic room temperature control by controlling boiler, pump and valve operation built-in two factory programs and a third for individual settings two selectable temperature - day and night six heating periods per day possibility of short-term changes in heating temperature heater adjustable every 0,5 C protection function of the installation against freezing wireless radio with receiver 81,50 Regulators and protections for circuits and pumps CH and DHW PRODUCT NAME APPLICATION PRICE WITHOUT VAT EKOSOL 400 cat. no. 506101 DELTA 200 3D cat. no. 201207 Solar controller control of two fields of solar panels control of the solar pump additional control output for circulating pump or heater or pump for loading second tank energy meter or read error choice of solar fluid choice of one of three programs of domestic hot water circulation pump program ability of creating own domestic hot water circulation pump Actuator controller of 3/4-way valve control of the 3/4-way valve actuator operation signaling of the pump and the 3/4-way valve possibility of connecting a room thermostat programming time and valve breaks boiler protection from overheating 76,00 43,00 DELTA 200 DUO cat. no. 201205 Pumps controller control of pump DHW or circulation pump boiler protection from overheating protection of the installation from freezing LED temperature display 48,00 DELTA 200 cat. no. 201203 Pump controller or pump DHW or circulation pump boiler protection from overheating protection of the installation from freezing LED temperature display 34,50

PRODUCT NAME APPLICATION PRICE WITHOUT VAT HYDROS 200 cat. no. 201201 Pump controller or pump DHW or circulation pump boiler protection from overheating protection of the installation from freezing LED temperature display 33,00 DK 5000 cat. no. 201101 Pump controller boiler protection from overheating protection of the installation from freezing switching the continuous operation of the central heating pump signaling pump operation 23,50 UZE 05/25 cat. no. 108001 Electronic safety system protection the pumps from running without water in the so-called dry run mode overload protection set two input current ranges two modes of operation - monostable and astable adjusting the thresholds of the system cooperation with 1 and 3 phase motors 77,00 UZE 05/25 with equipment cat. no. 108101 Electronic safety system protection the pumps from running without water in the so-called dry run mode overload protection set two input current ranges two modes of operation - monostable and astable adjusting the thresholds of the system cooperation with 1 and 3 phase motors system built in switchgear. Equipped with UZE 05, contactor, switch. 144,50 UZE 2000 cat. no. 108201 Electronic safety system protection of single-phase pumps against work without water so-called dry run overload protection cooperation with pressure switch programming thresholds of the system trip 35,00

Blower sets for boilers PRODUCT NAME APPLICATION PRICE WITHOUT VAT SET NO 4. E400 COMFORT cat. no. 601511 Blower set for boilers The set includes: controller EKOSTER 400, fan RV14RK, gasket, room panel CONTROL control of the fan work temperature protection system and room thermostat 126,00 SET NO 4. E 400 cat. no. 601501 Blower set for boilers The set includes: controller EKOSTER 400, fan RV14RK, gasket control of the fan work temperature protection system and room thermostat 108,00 SET NO 3. E200 COMFORT cat. no. 601411 SET NO 3. E200 cat. no. 601401 Blower set for boilers The set includes: controller EKOSTER 200, fan RV14RK, gasket, room panel CONTROL control of the fan work smooth fan operation and power settings adjustable damping time and automatic control turn off after extinguishing of the boiler Blower set for boilers The set includes: controller EKOSTER 200, fan RV14RK, gasket control of the fan work smooth fan operation and power settings adjustable damping time and automatic control turn off after extinguishing of the boiler 113,50 97,00 Fans PRODUCT NAME APPLICATION PRICE WITHOUT VAT WPA 120 cat. no. 803205 RV 14 RK cat. no. 80130909 RV 14 PRK cat. no. 80130505 Blowing fan is designed for blowing the air in the boilers onto the solid fuels and other technological devices aluminium frame, black throttle, flap, 1.6 rm cable with a plug Blowing fan is designed for blowing the air in the boilers onto the solid fuels and other technological devices metal frame, black throttle, flap, 1.6 rm cable with a plug Blowing fan is designed for blowing the air in the boilers onto the solid fuels and other technological devices metal frame, black throttle, flap, 1.6 rm cable with a plug 52,00 46,00 46,00

PRODUCT NAME APPLICATION PRICE WITHOUT VAT U02 cat. no. 981103 Gasket for fan RV14RK 0,60 U03 cat. no. 981105 Gasket for fan RV14PRK 0,60 Replacements PRODUCT NAME APPLICATION PRICE WITHOUT VAT CT102 cat. no. 901103 Temperature sensor measuring range -40 o C to +100 o C PVC white cable L=150cm 8,00 CT105 cat. no. 901109 Temperature sensor measuring range -40 o C to +100 o C PVC white cable L=300cm 9,00 CT132 cat. no. 901403 Temperature sensor measuring range -40 o C to +150 o C silicon cable L=80cm 7,50 CT133 cat. no. 901405 Temperature sensor measuring range -40 o C to +150 o C silicon cable L=150cm 8,00 CT136 cat. no. 901411 Temperature sensor measuring range -40 o C to +150 o C silicon cable L=300cm 9,00 TR102 cat. no. 941103 Thermal switch off temperature 90 o C silicon cable L=80cm 7,50 TR103 cat. no. 941105 Thermal switch off temperature 90 o C silicon cable L=150cm 8,00 CT601 cat. no. 931001 Outdoor temperature sensor measuring range -40 o C to +80 o C accuracy class B 12,50

Description of the icons 1 NUMBER OF PUMPS CONTROLLING OUTPUTS One pump controlling output COLD RETURN PROTECTION Option of controlling the 3-way valve in the boiler protection system against cold return 2 NUMBER OF PUMPS CONTROLLING OUTPUTS Two pump controlling outputs EMERGENCY GRID Emergency grid control 3 Three pump controlling outputs NUMBER OF PUMPS CONTROLLING OUTPUTS SOLAR PUMP Solar pump control mode 4 Four pump controlling outputs NUMBER OF PUMPS CONTROLLING OUTPUTS SUMMER MODE Heating circuit in the summer time control CENTRAL HEATING PUMP Control of the central heating pump OVERLOAD PROTECTION Option protecting the pump against overload DHW PUMP Control of the DHW pump DRY RUN PROTECTION Option protecting the pump against dry run (i.e. operation without water) CIRCULATION PUMP Control of the circulation pump ENERGY METER Produced energy meter in solar installations 2ND CIRCUIT PUMP Control of the second circuit pump or floor heating pump THERMAL FUSE Thermal fuse as additional protection of the boiler against overheating FAN Blowing fan control ROOM THERMOSTAT Cooperation with a room thermostat FEEDER Feeder operation control CONTROL PANEL Cooperation with a remote control panel 3W VALVE 3 - way valve control REED RELAY Cooperation with piston feeders with a contactor 4W VALVE 4 - way valve control FLUE GAS TEMPERATURE Possibility of flue gas temperature measurement THRUST ADJUSTMENT Boiler thrust adjustment by opening and closing the air into the furnace inflow flap CONTROL THE WEATHER Control based on the outside temperature RETURN PROTECTION PUMP Control of the pump operating as a return protection of the boiler FROST PROTECTION Frost protection FAN MODULATION Smooth fan operation and power settings ALARMS Alarms DHW DISINFECTION Programmable disinfection of the DHW circuit protecting against Legionella HALL SENSOR Hall sensor WEEKLY PROGRAM Control of the boiler and DHW pump operation acc. to one of the weekly programs FEEDER REVERSE Feeder reverse function to remove the fouling of fuel PRIORYTET DHW PRIORITY Option of turning on/off the domestic hot water priority COMFORT SYSTEM Periodical pump turning on option to protect against calcification

Notes

Full range of products DK System is on the website: www.dksystem.pl Zeskanuj kod QR

INTELIGENTNE ROZWIĄZANIA Order direct to: biuro@dksystem.pl www.dksystem.pl GIOŚ: E0002018W Sales department 53-030 Wrocław, ul. Przyjaźni 141 tel. 71 / 333 73 88 tel. 71 / 333 74 36 fax 71 / 333 73 31 The price list does not constitute and is published for information purposes only. The prices given are subject to change.