Cooling Strip Model SPB

Similar documents
Fire protection unit

Units for suspended ceilings

Units for suspended cei lings

Ceiling swirl diffusers

Ceiling swirl diffusers

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Passive chilled beams

Additional operating instructions according to ATEX 2014/34/EU Ceiling Impulse Diffuser Model PIL

Fan Coil Unit CULTRA

Halton Rex 600 Basic R6B - Active chilled beam

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

Ceiling diffusers. Type DLQL

Chilled Ceiling Elements

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

Halton CPT Passive Chilled Beam

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Installation, Mounting and Maintenance DISA-300

iq Star LYRA II chilled beam cassette

Contact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.

CHILLED BEAM CASSETTE IQ STAR LYRA

Halton Rex for Vario R6O - Variable air volume chilled beam

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

Air distribution systems. Opticlean OC-Q...

Smoke extraction duct of sheet steel

iq Star LYRA II chilled beam cassette

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

BSK-RPR Fire Damper. Additional operating instructions according to

BKA-EN Fire Damper. Additional operating instructions according to

KLIMA Active Chilled Beams

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

LindabArchitect. Supply air beam. lindab we simplify construction

Halton CHB Active chilled beam with boost function for bulkhead installation

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

Units for suspended ceilings Type DID632

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Carat. Chilled beams. Use. Worth noting. Installation. Key figures. lindab chilled beams

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

PARAGON. Compact comfort module. Key figures

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Radiant Ceiling. Metawell Klimadecke 1

Primo Hotel. General. Indoor climate units for hotel rooms

Ultraflex Ceiling Grid (UFR)

LindabCapella. Supply air beam

C o o l i n g a n d h e a t i n g s y s t e m s

Technical Concept. Ultraflex Ceiling Grid (UFR) All Types Cleanroom Ceiling Systems

ACBH/ACBV ACTIVE CHILLED BEAM INSTALLATION MANUAL. Date: 05/12 Reference # : L-50.

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

Metropolitan high output natural and powered trench heaters

Polaris-I-60. active chilled beam. the future of space conditioning

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

HOTEL CHILLED BEAM IQ STAR SILENCIA

lindab ventilation Lindab Comfort Waterborne indoor climate solutions Product overview

Cassette units Model Comfort Circle. - heating - cooling - ventilation

CASSETTE UNIT. Comfort Circle

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Technology for life. Unit heater LH

Thermostatic valves with radiator connection systems

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

CONDOR. Supply air ceiling QUICK FACTS

Ceiling displacement outlet non-adjustable Q-DN... adjustable Q-DV...

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

T6 - Centrally Connected & VONOPLAN T6.

Chilled ceiling panel INDUCOOL-Compact

System architecture. Air treatment Index

Supply air unit VEKA Installation & Maintenance

Metal Cassette Ceiling with BEKA Heating and Cooling Mats

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.

PARASOL EX. Suspended comfort modules QUICK FACTS

4 Storage cabinets SCALA

Type CODE Speed Heating Cooling

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Heating and cooling ceiling systems Zehnder ZBN Planning document. Heating Cooling Fresh Air Clean Air

WOLF VENTILATION SYSTEM PRICE LIST

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Mikrotherm. Manual Radiator Valves With presetting

Thermostatic valve bodies

ATC Heating Devices. P. 1 ATC Heating Devices

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

TopVent Design Handbook

QZHW Fan Coil Unit. Key features. Specifications

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

Recessed. Air Curtain. Fig 1. Recessed air curtain

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Transcription:

Cooling Strip Model SPB Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de

Contents Description...3 Advantages... 3 Quick selection... 3 Short overview of data... 3 Material and surface... 3 Dimensions and weights...4 Dimensions... 4 Weight... 4 Water connection... 4 Accessories...5 Venting nipple at the cooling register (-EN)... 5 Mounting shackle painted (-MB)... 5 Mounting shackle painted to RAL9010 (-MBL)... 5 Mounting bracket for false ceiling assembly (-MW)... 5 Adjusting piece for housing (-PS)... 5 Set of hoses (-FS)... 5 Technical Data - Cooling...6 Layout example... 8 Legend...9 Order code...9 Specification text... 10 Z11/11-2

Description Quick selection SPB-PA SPB-LB The cooling strip SPB is used for room cooling. Heat transfer is by radiation and convection. Warm room air rises to the ceiling area, is cooled at the cooling strip, and sinks down to the occupied area as a result of the higher specific density. The underside of the cooling strip consists of perforated painted sheet steel with a free cross-section of 50%. The cooling strips are available in lengths of 1200...4200 mm at intervals of 100 mm. The coolings are either integrated into the false ceiling or mounted freely suspended without a false ceiling When a false ceiling is mounted, exhaust openings having the same surface area as the cooling strips must be provided. For maintenance, service, retrofitting, etc., inspection openings in sufficient number and size must be provided on site. Attention! The cold water supply temperature must be selected such that it does not fall below the dew point, Advantages - High energy efficiency - High performance (compensation of high thermal loads) - Low mounting and maintenance expenditure - Easy cleaning of the cooling register and the housing The diagram shows the approximate cooling capacity P in watts at an amount of water q v of 0.05 l/s and a temperature difference between room air and the average water temperature of 8 K. P k (W) = Cooling capacity NL (mm) = Nominal length Short overview of data NL (mm) L (mm) h (mm) b (mm) 1200-4200 (per 100 mm) Cooling capacity: approx. 260 W/m (Δt = 10 K) Underside made of perforated sheet steel painted to RAL 9010 (white) with a free cross-section of 50%. Material and surface The housing is made of sheet steel painted to RAL 9010 (white). The housing can also be painted to other RAL colours at an extra charge. The cooling register consists of copper pipes ø15 x 1.0 mm with pressed-on aluminium blades. Max. operating pressure =NL-8 140 = 1600 kpa 430 570 Z11/11-3

Dimensions and weights Dimensions SPB 430 SPB 570 Lengths - 1200...4200 mm at intervals of 100 mm Weight SPB 430 SPB 570 = 8.0 kg/m = 9.0 kg/m Water connection (-WAH) horizontal (-WAV) vertical Z11/11-4

Accessories Venting nipple at the cooling register (-EN) - To ventilate the cooling register when the level of the hydraulic network is lower than the level of the cooling register. Mounting shackle painted (-MB) - Specific mounting plate for suspending the cooling strips from the load-bearing raw ceiling. Movable in longitudinal direction 1 set (2 pieces) per cooling strip. Mounting shackle painted to RAL9010 (-MBL) - Specific mounting plate for suspending the cooling strips from the load-bearing raw ceiling. Movable in longitudinal direction 1 set (2 pieces) per cooling strip. Set of hoses (-FS) - Flexible hoses, diffusion-resistant to DIN 4726 nominal width 13 mm with stainless steel braid temperature-resistant from -40 C to +80 C, test pressure 30 bar, working pressure 10 bar, lengths 500, 800, 1200 mm. - with two-sided 90 bend plug-in fitting - with one-sided 90 bend plug-in fitting at the cooling sail and straight plug-in fitting for connection to onsite ductwork. - with one-sided 90 bend plug-in fitting at the cooling sail and ½" flat seal spigot nut for connection to on-site ductwork. - with one-sided 90 bend plug-in fitting at the cooling sail and ¾" flat seal spigot nut for connection to on-site ductwork. Mounting bracket for false ceiling assembly (-MW) - The brackets are fastened to the raw ceiling and connected to the mounting shackles via threaded bars. Adjusting piece for housing (-PS) - To adjust the strip length or when the strips are arranged in rows, an adjusting piece of the same shape as the cooling strip can be installed. In the standard model, the adjusting piece has open front sides, allowing the duct and water pipes to be passed through the adjusting piece. If, for example, a front side jacket is desired, this must be indicated in the order. The bottom plate of the adjusting piece can be simply removed, for example in order to connect the copper tubes. Lengths 400, 600, 900, 1200 mm Accessories (-MW) (-MB / MBL) (-GS) (-MB / MBL) (-GS) M8 threaded rod on site Z11/11-5

Technical Data - Cooling Cooling capacity (W/m), effective length P k0.05 for cooling strip SPB Amount of water = 0.05 l/s Correction of the cooling capacity for water mounts unequal to 0.05 l/s Correction factor Z11/11-6

Amount of water (l/h) Pressure drop, water (kpa) Z11/11-7

Layout example Prerequisites: Max. length of strip 4200 mm Cooling capacity 700 W Room air temperature 24 C Cooling support temperature 14...16 C Solution, cooling: Temperature difference between air and water Δt = 24 (14 + 16) / 2 = 9 K. According to the diagram "Cooling capacity in W/ m, effective length, P k0.05, for cooling strip SPB", the P k0.05 for a 430 mm broad cooling strip with perforated underside and an amount of water of 0.05 l/s is 218 W/m. The correction of the amount of water according to the diagram "Correction of the cooling capacity for amounts of water other than 0.05 l/s" is K = P k 0.083 /P k 0.05 = 1.05. Thus, due the higher amount of water, the actual capacity is 5% higher than the value shown in the diagram. P k = 1.05 x 218 = 229 W/m Required effective length (battery length) L eff = 700/229 = 3100 mm. Correction Housing length L = 3100 + 100 = 3200 mm. This means that the max. housing length of 4200 mm does not have to be used. According to the diagram "Pressure loss, water", the pressure loss of the above the battery Δp w is 12 kpa. In the diagram "Amount of water, l/s", the amount of water q w is 0.083 l/s at Δt w = 2 K and a cooling capacity of700 W. Correction of the amount of water based on the diagram Selecting an SPB-430-1 If the temperature of the air entering the strip is 1 K above room temperature (defined at 1100 mm above floor height), Δt = 25 (14 + 16)/2 = 10 K compared with 9 K in the above example. Under these conditions, an effective length of 2800 mm instead of 3100 mm is required. Z11/11-8

Legend NL (mm) = Nominal length L (mm) = Housing length (NL - 8) L eff (mm) = Effective length = battery length = NL - 100 b (mm) = Strip width X (mm) = Extension P k (W or W/m L eff ) = Cooling capacity P k0.05 (W or W/m L eff ) = Cooling capacity at an amount of water of 0.05 l/s q w [l/s] = Amount of water t r (K) = Room air temperature Δt w (K) = Temperature difference between water supply and water return t mw (K) = Average water temperature Δt (K) Temperature difference between (t r t mw ) upon cooling Δp w (kpa) = Pressure drop, water Order code Width 430 mm -430 horizontal -WAH Cooling strip SPB with perforated sheet grille Water connection Width 570 mm -570 vertical -WAV Nominal length -NL (1200-4200mm in 100mm steps) Order example: SPB-430-LB-WAH-1200 Unless stated otherwise, the thick-frame model will be delivered! Accessories Mounting shackle unpainted -MB Venting nipple -EN Adjusting piece -PS (-400/-600/-900/-1200) Mounting shackle painted to RAL 9010 (white) -MBL Mounting bracket -MW Set of hoses -FS (-500/-800/-1200) Control units Z11/11-9

Specification text The passive cooling strip SPB is used for room cooling and for removing high internal heat loads. The cooling strips are mounted either flush with the ceiling or freely suspended. On-site suspension is done either with threaded rods or - more easilydirectly in the support profiles of the false ceiling by means of mounting shackles that lock into place and can be moved in longitudinal direction. The housing and the perforated sheet grille consist of galvanised sheet steel, as standard painted to RAL9010 (white), optionally to a different RAL colour. The cooling register consists of a copper pipe with joint of diameter 15 mm and aluminium blades, while the working pressure is 1600 kpa. The cooling strips are available in lengths of 1200...4200 mm at intervals of 100 mm. Product: SCHAKO type SPB Cooling strip width: - 430 mm - 570 mm Model: - With perforated sheet grille (-LB) Nominal length: - 1200...4200 mm at intervals of 100 mm (-NL) Water connection: - horizontal (-WAH) - vertical (-WAV) Accessories: - Venting nipple on the battery (-EN) - Mounting bracket (-MW) - Mounting shackle - unpainted (-MB) - painted (-MBL) - Adjusting piece (-PS) - 400 mm (-PS-400) - 600 mm (-PS-600) - 900 mm (-PS-900) - 1200 mm (-PS-1200) - Set of hoses (-FS) - 500 mm (-FS-500) - 800 mm (-FS-800) - 1200 mm (-FS-1200) - Matching controlling and regulating equipment available Z11/11-10