Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation Instructions

Installation Instruction

Installation Instructions

Fig. 1--Typical Coil Installation

Installation Instructions

_"RETURN. s ) EVAPORATOR COIL _ DOWNFLOW FURNACE UPFLOW I R I! / _[_SUPPLY

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

Installation Instruction

Installation Instructions

Installation Instructions

Installation Instructions Part No , Part No Part No

INSTALLATION INSTRUCTIONS

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Owner s Information Manual

Installation Instructions

INSTALLATION INSTRUCTIONS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Installation Instructions

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

PL Series Premier Indoor Plenum Coils

Installation Instructions

Residential Piping and Long Line Guideline

Installation Instructions

Installation Instructions

C7 Series Split System Uncased Indoor Coils

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

Fig. 1 - Unit PHD4 and WPH4

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

Installation Instructions

Installation Instructions

Installation Instructions

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

INSTALLATION INSTRUCTIONS

Owner s Information Manual

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

Installation Instructions

Installation Instructions

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Installation Instructions

INSTALLATION MANUAL WARNING WARNING FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CF

Installation Instructions

Installation Instructions

40TCQ Vertical Ducted Fan Coil Unit for Variable Refrigerant Flow (VRF) Heat Pump or Heat Recovery System

INSTALLATION INSTRUCTIONS

Installation Instructions

Fig. 1 - Unit PGD4, PGS4, WPG4

Installation Instructions

Installation Instructions

UPFLOW/DOWNFLOW COILS

Installation Instructions

Installation Instructions

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

Installation Instructions

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Installation Instructions

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Installation Instructions

Installation Instructions

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

Installation Instructions

CAUTION. Check Equipment and Job Site. Clearance Requirements. Unpack Unit

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS APARTMENT FAN COIL UNIT FMA4X, FMA4P

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

Installation Instructions

Transcription:

Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and National Electrical Codes (NEC) for special requirements. It is important to recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices, which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. WARNING: Before installing or servicing system, always turn off main power to system. There may be more than one disconnect switch. Turn off accessory heater power if applicable. Electrical shock can cause personal injury or death. CAUTION: This coil contains Nitrogen precharge of 15 PSIG. Release of this pressure through the center of the rubber plugs is required before removing the plugs. Failure to follow this CAUTION could result in minor personal injury or product and property damage. IMPORTANT: Nitrogen can leak out through the needle pierce hole in the plugs. This does not indicate a leaking coil nor warrant return of the coil. Form: IM-CK3B-08 Cancels: IM-CK3B-07 Printed in U.S.A. 05-03 Catalog No. 63CK-3B6

B 20 3 4 3 15 16 3 8 IN. LIQUID LINE A OPTIONAL DUCT FILLER PANEL E DUCT OPENING TYPICAL BOTH ENDS 3 2 7 8 UNIT 4 3 8 9 1 8 C D SUCTION LINE FRONT A 3 8 1 1 2 1 11 16 3 4 IN. NPT DRAIN B CK3BXA024(0,T)17 17 9/16 19 1/16 10 1/16 5/8 16 37.0 CK3BXA030(0,T)17 17 9/16 19 1/16 10 1/16 3/4 16 40.5 CK3BXA036(0,T)17 17 9/16 22 1/16 10 1/4 3/4 16 45.5 CK3BXA042(0,T)21 21 1/16 22 1/16 10 1/4 7/8 19 1/2 47.0 CK3BXA048(0,T)21 21 1/16 22 1/16 10 1/4 7/8 19 1/2 51.0 CK3BXA060(0,T)24 24 9/16 28 1/8 13 3/16 7/8 23 64.0 Note: For the 10th digit position in the model number, 0 = standard copper coil and T = tin-plated copper coil. C Fig. 2 Dimensional Drawing INTRODUCTION The CK3B is a horizontal, multi-use cased furnace coil. (See Fig. 1.) With the use of field-supplied transition duct, these furnace coils can also be applied to other similar horizontal furnaces on the market. The CK3B is available in sizes 024 through 060. (See Fig. 2.) NOTE: Models with tin-plated copper coils ( T in the 10th position of the model number) are installed the same as standard copper coils. INSTALLATION The unit can be installed on a work platform, secured to roof truss in an attic, suspended from hangers on floor joists in crawl space, or installed on blocks. It is designed to allow airflow in either direction, to mate with horizontal-left (see Fig. 5) or horizontal-right (see Fig. 6) furnace installations. NOTE: Before placing ductwork on casing opening, check the rubber grommet (see Fig. 3) to ensure that the grommet is located so the bottom end is within the condensate pan. Moisture on the header tube will run down the grommet and drip into the pan. NOTE: Remove shipping brace from both ends of casing prior to installation. Also remove corrugated shipping block from inside the right end of casing prior to installation. PROCEDURE 1 FURNACE ATTACHMENT A. Attach coil to furnace. The attachment plates (3) and filler plate (1) are packaged together and placed in coil carton. Remove these items, verifying the correct amount. Use the following procedure to attach CK3B horizontal coil to furnace. 1. Three attachment plates are used to attach coil to furnace. Application determines which end of the coil will be attached to the furnace. 2. Use self-tapping screws to mount attachment plates to coil casing. (See Fig. 4A.) 3. Connect furnace snugly against coil casing. 4. Use self-tapping screws to attach furnace. (See Fig. 4B.) 5. Seal joint between coil casing and furnace to create air tight seal using locally approved materials. D 1 1 4 E 18 7 8 RIGHT SIDE SHIPPING WEIGHT (LB) A97521 2

GROMMET A00188 Fig. 3 Grommet Location DRILL AFTER COIL IS INSTALLED SELF-TAPPING SCREWS A B A97201 Fig. 4 Duct Flange Assembly PROCEDURE 2 HORIZONTAL ATTIC INSTALLATION A. Construct work platform to support coil/furnace combination. 1. Construct work platform, using material in platform that will support the weight of an installer or a service person. 2. Place work platform in front of discharge end of furnace. 3. Secure platform to building joists. B. Install coil. To suspend CK3B: 1. Cut plumbers strap to desired lengths. 2. Attach plumbers strap to 4 corners of coil casing. (See Fig. 7.) 3. Use a minimum of 2 screws per corner to attach plumbers strap to casing. 4. Position and secure coil in front of furnace discharge end. 5. Make sure coil is level for proper condensate drainage. 6. Using appropriate fasteners for duct type, connect supply-air duct to coil. 7. Coils are shipped with a filler plate included in the package for use when coil is coupled with a narrow furnace. Attach filler plate between coil flange in furnace as shown in Fig. 5 and 6. PROCEDURE 3 HORIZONTAL CRAWL SPACE INSTALLATION As an alternate to horizontal attic installation, the CK3B horizontal coil can be installed in a crawl space by mounting on suitable blocks, pads or by hanging from floor joists. 3

FILLER PLATE AIRFLOW N-COIL DRAIN CONNECTION FURNACE Fig. 5 Horizontal Left Installation with Filler Plate To suspend CK3B: 1. Cut plumbers strap to desired lengths. 2. Attach plumbers strap to 4 corners of coil casing (See Fig. 7). 3. Use a minimum of 2 screws per corner to attach plumbers strap to casing. 4. Position and secure coil in front of furnace discharge end. 5. Make sure coil is level for proper condensate drainage. 6. Using appropriate fasteners from duct type, connect supply-air duct to coil. PROCEDURE 4 REFRIGERANT LINES Refrigerant lines must be configured per local building codes. Lay out lines in relation to specifications and job site requirements. PROCEDURE 5 CONNECT REFRIGERANT LIQUID AND SUCTION LINES For matched and mismatched systems, use line sizes recommended in outdoor unit Installation Instructions. The coil can be connected to outdoor units using accessory refrigerant line sets or field-supplied lines of refrigerant grade. Always evacuate lines and reclaim refrigerant when making connections or flaring refrigerant lines. Leak check connections before insulating entire suction line. CAUTION: If unit is to be installed on system with a thermostatic expansion valve, removal of indoor coil piston is required. Failure to follow this CAUTION could result in minor personal injury or product and property damage. A97203 A. Suction Line Suction line is designed for field sweat connections. Provide inverted loop on suction line if line set exceeds 50 ft. per long line application guide. Sweat stub has a rubber shipping plug to keep out moisture and dirt. Remove plug only when ready to make field sweat connection. CAUTION: To avoid damage while brazing, wrap tubing or fittings with a heat-sinking material such as a wet cloth. Failure to follow this CAUTION could result in minor personal injury or product and property damage. B. Liquid Line Liquid line is designed for sweat connection. During installation these steps should be followed: 1. Replace piston, if required. Check piston size stamped into side of brass hex nut. (See Fig. 8.) If piston number does not match required piston shown on outdoor unit rating plate, replace indoor piston with piston shipped with outdoor unit. 2. When piston is replaced finger tighten plus 1/4 turn. CAUTION: Remove Teflon seal during brazing. Replace when fitting has cooled. Failure to follow this CAUTION could result in minor personal injury or product and property damage. 3. Liquid stub has a rubber shipping plug to keep out moisture and dirt. Remove plug only when ready to make field sweat connection. SYSTEM REFRIGERANT CONTROL A refrigerant control device (bypass type) is factory supplied with coil. (See Table 2.) The piston has a refrigerant metering hole through it, and is field replaceable. The piston shipped with indoor coil may be different from piston shipped with outdoor condensing unit. If this is the case, change the indoor piston. Always use piston shipped with outdoor condensing unit. PROCEDURE 6 CONNECT CONDENSATE DRAIN LINE The CK3B coil is designed to dispose of accumulated water through built-in condensate drain fittings. It is recommended that PVC fittings be used on the condensate pan. Do not over-tighten. Finger tighten plus 1 1/2 turns. Be sure to install plastic plug in unused condensate drain fitting. 4

FILLER PLATE AIRFLOW FURNACE N-COIL DRAIN CONNECTION A97037 Fig. 6 Horizontal Right Installation with Filler Plate PLUMBERS STRAP 2 SCREWS FOR ATTACHMENT TO CASING A97014 Fig. 7 CK3B Suspension with Plumbers Strap Table 2 Refrigerant Metering Device MODEL CK3B COIL SIZE PISTON NUMBER 024 59 030 67 036 70 042 78 048 84 060 90 Install a trap in condensate line as close to the CK3B coil as possible. Make trap at least 2 1/4 in. deep and not higher than the bottom of unit condensate drain openings. (See Fig. 9.) NOTE: If unit is located in or above a living space where damage may result form condensate overflow, a field-supplied, external condensate pan should be installed under the entire unit, and a secondary condensate line (with appropriate trap) should be run from unit into pan. Any condensate in this external condensate pan should be drained to a noticeable place. As an alternative to using an external condensate pan, some localities may allow the running of a separate 3/4 in. condensate line (with appropriate trap) to a place where condensate will be noticeable. The owner of the structure must be informed that when condensate flows from the secondary drain or external condensate pan, the unit requires servicing or water damage will occur. 5

PLUG 13 16 IN. BRASS HEX NUT PISTON RETAINER STRAINER PISTON DISTRIBUTOR 5 9 PISTON NUMBER STAMPED INTO SIDE OF NUT TEFLON SEAL Fig. 8 Refrigerant Control Device Components 3 4 IN. BRASS HEX BODY COPPER TUBE A96248 Install traps in condensate lines as close to coil as possible. (See Fig. 9.) Make sure that outlet of each trap is below its connection to condensate pan to prevent condensate from overflowing drain pan. Prime all traps, test for leaks, and insulate traps and lines if located above a living area. Consult local codes for additional restrictions or precautions. 3 * * OR TRAP TO LOCAL CODE Fig. 9 Condensate Trap A03087 6

SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG 1-800-644-5544 [ ] Packaged Service Training [ ] Classroom Service Training 7 A94328

2003 CAC/BDP 7310 W. Morris St., Indianapolis, IN 46231 imck3b08 8 Catalog No. 63CK-3B6