WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE

Similar documents
Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

WOLF GAS CONDENSING BOILERS COMFORTLINE

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

Gas condensing centre CGS-2 gas condensing centre

ENERGY TOP. Condensing boiler solutions

Logamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

1 VICTRIX ZEUS Superior kw I features

Price list Heating systems. Issue March 2016

Wall mounted gas condensing boiler CGB-2 wall mounted gas condensing boiler CGB-2K wall mounted gas condensing combi boiler

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

GHP AWO 38 Technical overview

Technical documentation Solar technology

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Domestic Gas Boiler Guide

Domestic Gas Boiler Guide

VIESMANN. Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P. Pellet boiler 4to48kW. Vitotec folder, register 12. File in: Type VL3B

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

ACCUMULATION OF EUROPEAN CLASS

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Solar technology. Technical documentation. Flat-plate collectors CFK-1/TopSonF3-1/F3-Q Vacuum tube collector CRK Swimming pool absorber

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Ciao Green Condensing Wall-Hung Boilers

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

Technical documentation Comfort domestic ventilation system

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

The iqe Boiler Range. Combination and System T Boilers.

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Sirius FS. Working towards a cleaner future

Domestic Product Guide

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

4FLOOR-STANDING GAS CONDENSING BOILERS

VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

Gas heaters and convectors ROBUR

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

Seradens Super Seradens Super Plus

Domestic Gas Boiler Guide

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

WOLF VENTILATION SYSTEM PRICE LIST

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

CITY OPEN - CITY BOX from 25 to 35 kw

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

Power X High Power Condensing Wall-Hung Boilers

Sirius WH. Working towards a cleaner future

Exclusive Green E Condensing Wall-Hung Boilers

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

RIELLO 40 GS/M SERIES

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Power X High Power Condensing Wall-Hung Boilers

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Operating instructions Oil condensing boiler

C Tahiti. condensing

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

SGE Condensing Gas - Solar Water Heater

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

SPECIFICATIONS - NIKE

Gas wall system and combination boilers. Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Domestic Product Guide

Light commercial products. High output boilers Cascade systems

CAST IRON ATMOSPHERIC BOILERS

BFC Cyclone Condensing Glass-Lined Water Heater

VIESMANN. Installation instructions VITODENS 200-W. for contractors

Gas condensing boilers

Mynute Green Condensing Wall-Hung Boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

VITOPLEX. Low temperature oil and gas fired boilers Rated output Vitoplex 100: 575 to 1750 kw Vitoplex 200: 90 to 560 kw Vitoplex 300: 80 to 1750 kw

TopGas Wall Hung Condensing Gas Boiler

Transcription:

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE CGB-2(K) / CGW-2 / CGS-2L / CGS-2R / CSZ-2 30m 3 /h

THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation projects alike. The range of WOLF control units can meet any requirement for heating convenience. All equipment is easy to operate, highly energy efficient and reliable. Solar thermal systems can be swiftly integrated into existing systems. WOLF equipment is easy and quick to install and maintain.

COMFORTLINE GAS CONDENSING BOILERS CGB-2 04-05 CGB-2(K) 06 CSW-120 06 CGW-2 07 CGS-2L 08 CGS-2R 09 CSZ-2 10-11 SPECIFICATION CGB-2 / CGB-2(K) 12-13 CGW-2 14-15 CGS-2L 16-17 CGS-2R 18-19 CSZ-2 20-21 CSW-120 22-23 STANDARD CONTROL UNIT 24 CONTROL ACCESSORIES 25-27 AIR/FLUE GAS ROUTING 28-29 ACCESSORIES 30-32 03 COMFORTLINE GAS CONDENSING BOILERS

Gas condensing boilers, sealed combustion chamber, for room sealed or open flue operation High standard seasonal efficiency [to DIN] up to 110 % (net cv) / 99 % (gross cv) for the best possible energy efficiency Meets the requirements for the "Blue Angel" eco-label according to RAL-UZ 61 when operated with natural gas Premix burner for natural gas E, LL and LPG, variable modulating heating output from 1.8 kw With expansion vessel, modulating high efficiency pump (EEI <0.23) and 3-way valve as standard Appliance converts automatically to a different gas type without conversion kit or resetting of the control unit Automatic CO2 setting with self-calibrating combustion air controller for extremely clean combustion Optimum utilisation of condensing technology by controlling the spread without an overflow valve; no return temperature raising required Heating water heat exchanger can be pivoted under system pressure for maintenance without having to drain the heating water WOLF "ALUPro" coated heating water heat exchanger 04

Communication via smartphone, laptop or PC WOLF WRS 2 control system can be set and operated via smartphone or PC BENEFITS OF WOLF GAS CONDENSING BOILERS UP TO 24 KW CGB-2(K) / CGW-2 / CGS-2 / CSZ-2 Efficient combustion technology with gas-adaptive self-calibrating combustion controller that adjusts automatically to the prevailing gas quality Easy flue gas emissions testing from outside without opening the appliance Convenient access to all components for quick installation and easy operation and maintenance 05 COMFORTLINE GAS CONDENSING BOILERS

CGB-2-14, -20, -24 GAS CONDENSING BOILER FOR HEATING with option to connect a DHW cylinder, e.g. CSW-120 MODULATION RANGE for flow / return 50 / 30 C BOOSTER OUTPUT for cylinder heating CGB-2-14 from 2.1 to 15.2 kw CGB-2-20 from 4.4 to 20.4 kw CGB-2-20 22.2 kw CGB-2-24 from 5.6 to 25.8 kw CGB-2-24 27.1 kw CGB-2K-20, -24 GAS CONDENSING BOILER FOR HEATING AND DHW - with integral stainless steel DHW heat exchanger - for demand-dependent, hygienic DHW heating - precise flow control ensures constant draw-off temperature MODULATION RANGE for flow / return 50 / 30 C BOOSTER OUTPUT for DHW heating CGB-2K-20 from 4.4 to 20.4 kw CGB-2K-20 22.2 kw CGB-2K-24 from 5.6 to 25.8 kw CGB-2K-24 27.1 kw CSW-120 DHW CYLINDER Cleaning aperture and R¾" connections for flow, return, cold water, hot water and DHW circulation at the top of the cylinder for easy pipework connection and cleaning Internal indirect coil with large heat exchanger surface area for short heat-up times White RAL 9016 / powder-coated casing High continuous DHW output thanks to generously sized indirect coil 810 542 Rigid PUR foam thermal insulation all around the cylinder, applied directly to the cylinder surface, highly effective for low heat losses R½" drain outlet at the front, incl. drain valve and hose fitting Adjustable feet 542 Corrosion protection through enamelled cylinder interior and internal indirect coil to DIN 4753, Part 3. Additional corrosion protection through sacrificial magnesium anode integrated into the inspection and cleaning aperture 5 year statutory warranty 06

CGW-2-14/100L, -20/120L, -24/140L GAS CONDENSING CENTRE WITH HIGH PERFORMANCE STAINLESS STEEL STRATIFICATION CYLINDER Wall mounted gas condensing centre, comprising a wall mounted gas condensing boiler with a stainless steel DHW heat exchanger and a stainless steel stratification cylinder in modular design MODULATION RANGE for flow / return 50 / 30 C BOOSTER OUTPUT for stratification cylinders CGW-2-14/100L from 2.1 to 15.2 kw CGW-2-20/120L from 4.4 to 20.4 kw CGW-2-20/120L 22.2 kw CGW-2-24/140L from 5.6 to 25.8 kw CGW-2-24/140L 27.1 kw Integral and convenient DHW heating better than a DHW cylinder (with indirect coil) with 100, 120 or 140 l capacity "DHW turbo" with a stainless steel routing and distribution system for hot and cold water ensures quiet, radial water distribution and excellent DHW output (European patent pending) With the CGW-2-14/100L, filling a bath tub with around 140 l of water at 40 C only takes 10 minutes High savings on operating costs through efficient DHW heating and innovative insulation technology with integral annular gap system (utility model protection) Controlled cylinder heating for optimum energy efficiency through the effective utilisation of condensing technology (European patent granted) Compact layout as condensing boiler with attached stratification cylinder ensures very low installation costs Gas condensing centre is fully wired and ready to connect to the water system Can be split quickly and easily into two transportable modules weighing 35 kg and 19 kg for straightforward installation THE FOLLOWING ACCESSORIES ARE AVAILABLE TO ENSURE QUICK AND CLEAN INSTALLATION: DHW connection set with pressure reducer for concealed installation / surface mounting DHW connection set without pressure reducer for concealed installation / surface mounting Solar connection set Pipe cladding Disconnection point heating module / stratification cylinder DHW heating Cold water supply Heating circuit DHW outlet 07 COMFORTLINE GAS CONDENSING BOILERS

CGS-2-14/120L, -20/160L, -24/200L GAS CONDENSING CENTRE WITH STAINLESS STEEL DHW HEAT EXCHANGER AND ENAMELLED STEEL STRATIFICATION CYLINDER Gas condensing centre, comprising a wall mounted gas condensing boiler with a stainless steel DHW heat exchanger and a stratification cylinder in modular design MODULATION RANGE for flow / return 50 / 30 C BOOSTER OUTPUT for DHW heating 1462 CGS-2-14/120L from 2.1 to 15.2 kw CGS-2-20/160L from 4.4 to 20.4 kw CGS-2-20/160L 22.2 kw CGS-2-24/200L from 5.6 to 25.8 kw CGS-2-24/200L 27.1 kw The "Turbostop system" provides convenient DHW heating inside the stratification cylinder better than a DHW cylinder (with indirect coil) with 120, 160 or 200 l capacity Controlled cylinder heating for optimum energy efficiency through the effective utilisation of condensing technology (European patent granted) With the CGS-2-20/160L, filling a bath tub with around 230 l of water at 40 C only takes 10 minutes; the CGS-2-14/120L fills a bath with around 190 l of water at 40 C in the same time High output factor N L = 1.3 or 2.5 for heating from 10 C to 60 C Minimal heat losses thanks to highly efficient insulation technology just 1.0 kwh standby loss in 24 hours Compact layout as a wall mounted condensing boiler with stratification cylinder. Can be split easily into two modules of 35 kg and 49 kg respectively for easy installation Heating circuit 600 635 THE FOLLOWING ACCESSORIES ARE AVAILABLE TO ENSURE QUICK AND CLEAN INSTALLATION: Pipework connection set with flexible stainless steel pipes and thermal insulation, suitable for surface mounting or concealed installation Solar connection set for the additional control of a solar cylinder Drain outlet kit with triple hose retainer Pipework cladding with variable knock-out entries DHW heating DHW outlet Cold water supply Disconnection point heating module / stratification cylinder 08

CGS-2-14/150R, -20/150R, -24/150R GAS CONDENSING CENTRE WITH ENAMELLED STEEL DHW CYLINDER WITH INDIRECT COIL Gas condensing centre, comprising a wall mounted gas condensing boiler and DHW cylinder with indirect coil in a modular design MODULATION RANGE for flow / return 50 / 30 C BOOSTER OUTPUT for DHW heating CGS-2-14/150R from 2.1 to 15.2 kw CGS-2-20/150R from 4.4 to 20.4 kw CGS-2-20/150R 22.2 kw CGS-2-24/150R from 5.6 to 25.8 kw CGS-2-24/150R 27.1 kw Controlled cylinder heating for optimum energy efficiency through the effective utilisation of condensing technology (European patent granted) With the CGS-2-20/150R, filling a bath tub with around 230 l of water at 40 C only takes 10 minutes; the CGS-2-14/150R fills a bath with around 210 l of water at 40 C in the same time High output factor N L = 1.4 or 1.8 for heating from 10 C to 60 C Minimal heat losses thanks to highly efficient insulation technology just 1.47 kwh standby loss in 24 hours Compact design as condensing boiler and DHW cylinder with indirect coil. Can be split easily into two modules of 35 kg and 80 kg respectively for easy installation Cylinder heating via robust internal indirect coil with generously sized heat exchanger surface area for short heat-up times Heating circuit THE FOLLOWING ACCESSORIES ARE AVAILABLE TO ENSURE QUICK AND CLEAN INSTALLATION: Pipework connection set with flexible stainless steel pipes and thermal insulation, suitable for surface mounting or concealed installation Solar connection set for the additional control of a solar cylinder Drain outlet kit with triple hose retainer Pipework cladding with variable knock-out entries DHW outlet Cold water supply Disconnection point heating module / stratification cylinder 09 COMFORTLINE GAS CONDENSING BOILERS

CSZ-2-14/300R, -20/300R, -24/300R GAS CONDENSING SOLAR CENTRE WITH SOLAR CYLINDER, SOLAR PUMP ASSEMBLY AND CONTROL UNIT With its CSZ-2 series, WOLF offers the optimum compact solution gas condensing technology combined with solar DHW heating with a solar coverage rate of up to 60 % for buildings of up to 150 m² available floor area. Gas condensing boiler, solar cylinder, solar pump assembly with SM1-2 solar module and 25 l expansion vessel; 10 l drip pan for solar fluid, standard control unit for gas condensing boiler with BM-2 programming unit incl. outside temperature sensor Solar boiler stop for high solar yield Compact design the gas condensing solar centre fits in almost any recess BENEFITS OF WOLF GAS CONDENSING SOLAR CENTRES CSZ-2 Side clearances for service purposes are not required, as all components are accessible from the front; minimal clearance required on the connection side Solar cylinder with highly effective thermal insulation, incl. cylinder floor insulation Connections for central heating and solar circuit either on the left or right; connections for DHW, cold water and DHW circulation at the top 10

CSZ-2-14/300R, -20/300R, -24/300R GAS CONDENSING SOLAR CENTRE WITH SOLAR CYLINDER, SOLAR PUMP ASSEMBLY AND CONTROL UNIT Gas condensing solar centre, comprising a wall mounted gas condensing boiler with solar cylinder, a solar pump assembly with SM1 solar module and 25 l expansion vessel; 10 l drip pan for solar fluid, standard control unit for gas condensing boiler with BM-2 programming unit incl. outside temperature sensor, in a modular design MODULATION RANGE for flow / return 50 / 30 C BOOSTER OUTPUT for cylinder heating CSZ-2-14/300R from 2.1 to 15.2 kw CSZ-2-20/300R from 4.4 to 20.4 kw CSZ-2-20/300R 22.2 kw CSZ-2-24/300R from 5.6 to 25.8 kw CSZ-2-24/300R 27.1 kw Wall mounted gas condensing boiler, sealed combustion chamber, for open flue and room sealed operation High standard seasonal efficiency [to DIN] up to 110 % (net cv) / 99 % (gross cv) for the best possible energy efficiency Meets the requirements for the "Blue Angel" certificate of environmental excellence according to RAL-UZ 61 when operated with natural gas Premix burner for natural gas H, LL and LPG, variable modulating heating output from 1.8 kw With expansion vessel, modulating high efficiency pump (EEI <0.23) and 3-way valve as standard Heating water heat exchanger can be pivoted under system pressure for maintenance without having to drain the heating water WOLF "ALUPro" coated heating water heat exchanger Convenient access to all components for quick installation and straightforward operation and maintenance Easy flue gas emissions testing from outside without opening the appliance Efficient combustion technology with gas-adaptive, self-calibrating combustion controller that adjusts automatically to the prevailing gas quality flue gas inspection only required every 3 years Conversion between natural gas and LPG without conversion kit Automatic CO 2 setting with self-calibrating combustion controller for all gas types (natural gas, LPG) New WOLF WRS control system can be set and operated via smartphone or PC Optimum utilisation of condensing technology by controlling the spread without an overflow valve; no return temperature raising required WOLF Link home LAN/WLAN module allows communication via smartphone, laptop or PC KW Solar cylinder, 285 l capacity, made from steel with two robust, smooth tube internal indirect coils for very hard water, with enamel coating to DIN 4753 Highly effective thermal insulation and low heat losses through high grade rigid PUR foam insulation below the foil jacket of the cylinder The interior of the cylinder and the indirect coils are protected by an enamel coating and a sacrificial magnesium anode Large internal indirect coil surface areas ensure a short heat-up time and a high continuous DHW output Control unit with solar boiler stop for high solar yield With its compact design in a single casing, requiring just 600 x 1013 mm installation area, the gas condensing solar centre fits in almost any recess Minimal clearance required on the connection side only All control and service elements are accessible from the front, enabling a wide range of siting options 11 COMFORTLINE GAS CONDENSING BOILERS

SPECIFICATION CGB-2 14 20 24 - - CGB-2K - - - 20 24 Energy efficiency class, central heating A A A A A Energy efficiency class, DHW heating A A Rated heating output at 80/60 C kw 13.5 18.9/22.2 1) 23.8/27.1 1) 18.9/22.2 1) 23.8/27.1 1) Rated heating output at 50/30 C kw 15.2 20.4 25.8 20.4 25.8 Rated heat input kw 14.0 19.6/23.0 24.6/28.0 19.6/23.0 24.6/28.0 Lowest heating output (modulating) at 80/60 C kw 1.8/4.6 2) 3.8/6.8 2) 4.8/6.8 2) 3.8/6.8 2) 4.8/6.8 2) Lowest heating output (modulating) at 50/30 C kw 2.1/5.4 2) 4.4/7.4 2) 5.6/7.4 2) 4.4/7.4 2) 5.6/7.4 2) Lowest heat input (modulating) kw 1.9/4.9 2) 3.9/6.9 2) 4.9/6.9 2) 3.9/6.9 2) 4.9/6.9 2) Heating flow connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) Heating return connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) DHW connection G ¾" ¾" ¾" ¾" ¾" Cold water connection G ¾" ¾" ¾" ¾" ¾" Gas connection R ½" ½" ½" ½" ½" Air/flue pipe connection mm 60/100 60/100 60/100 60/100 60/100 Dimensions Depth 378 mm Width 440 mm Height 790 mm Air/flue gas routing Type B23 P, B33 P, C13(x), C33(x), C43(x), C53(x),C63(x), C83(x), C93(x) Gas category II 2N3B/P Gas connection values Natural gas E/H (net cv = 9.5 kwh/m³ = 34.2 MJ/m³) m³/h 1.44 2.06/2.42 2.52/2.95 2.06/2.42 2.52/2.95 Natural gas LL (net cv = 8.6 kwh/m³ = 31.0 MJ/m³) m³/h 1.59 2.28/2.67 2.79/3.25 2.28/2.67 2.79/3.25 LPG P (net cv = 12.8 kwh/m³ = 46.1 MJ/m³) kg/h 1.07 1.53/1.80 1.87/2.19 1.53/1.80 1.87/2.19 Supply pressure, natural gas (permissible min./max.) mbar 20 (17-25) Supply pressure, LPG gas (permissible min./max.) mbar 30 (25-35) Standard seasonal efficiency [to DIN] at 40/30 C (net cv/gross cv) % 110/99 Standard seasonal efficiency [to DIN] at 75/60 C (net cv/gross cv) % 107/96 Efficiency at rated load at 80/60 C (net cv/gross cv) % 98/88 Efficiency at 30 % partial load and TR = 30 C (net cv/gross cv) % 108/97 Flow temperature, factory setting C 75 Flow temperature up to approx. C 90 Max. total pressure bar 3.0 Max. residual head for heating circuit: High efficiency pump (EEI <0.23) 600 l/h flow rate (14 kw at t=20 K) mbar 550 860 l/h flow rate (20 kw at t=20 K) mbar - 430 1030 l/h flow rate (24 kw at t=20 K) mbar - - 280-280 DHW flow rate l/min - - - 2.0-6.5 2.0-8.0 Minimum flow pressure to EN 625 bar - - - 0.4 0.65 Spec. water throughput D at T = 30 K l/min - - - 10.3 13.0 Max. permissible total pressure, DHW bar - - - 10 10 DHW temperature range (adjustable) C - - - 45-65 45-65 DHW capacity of heating water heat exchanger l 1.3 Expansion vessel, total capacity l 10 Expansion vessel, pre-charge pressure bar 0.75-0.95 Flue gas temperature 80/60-50/30 at Qmax C 62-45 70-50 76-50 70-50 76-50 Flue gas temperature 80/60-50/30 at Qmin C 30-25 30-25 33-27 30-25 33-27 Flue gas mass flow rate at Qmax g/s 6.2 8.8/10.7 1) 10.9/13.0 1) 8.8/10.7 1) 10.9/13.0 1) Flue gas mass flow rate at Qmin g/s 0.9 1.8 2.3 1.8 2.3 Available gas fan draught at Qmax Pa 125 135 180 135 180 Available gas fan draught at Qmin Pa 10 14 17 14 17 Flue gas category G 52 NOx class 6 Amount of condensate at 50/30 C l/h appr. 1.4 appr. 2.0 appr. 2.4 appr. 2.0 appr. 2.4 Condensate ph value appr. 4.0 Power consumption on standby W 3 Maximum power consumption W 17-45/59 1) 17-51/63 1) 17-62/88 1) 17-51/63 1) 17-62/88 1) IP rating IP IP X4D Electrical connection/fuse protection 230 V / 50 Hz / 16 A/B Total weight kg 33 35 1) Heating mode/dhw mode 2) Natural gas/lpg (G31) 12

DIMENSIONS + CONNECTION DIMENSIONS CGB-2/CGB-2K CGB-2/CGB-2K 165(*106) 84 344 261(*202) 165(*106) 84 Ø 80/125 CGB-2 Ø 60/100 190 344 Ø 80/125 Ø 60/100 70 70 190 261(*202) 165(*106) 84 Darstellung A3 auf 1:9 TEB-lan CGB-2K 344 Darstellung A3 auf TEB-lan Ø 80/125 Ø 60/100 31 654 790 70 70 100100 440 48(*68) 378 654 790 40 31 70 100100 440 Side view 48(*68) 378 40 31 7 70 100100 440 1:5. 0,000 Front view 17.07.14 Lan Front view CGB-2-14 TW05046/14 Catia V5 R19 17.07.14 Lan 8614060 1:5 1 1 CGB-2-1 Cylinder return G¾" DHW connection with connection elbow G¾" TW05046/14 Catia V5 R19 861406 Heating return G¾" V.0000303958 Heating flow G¾" Gas connection R½" Gas connection R½" Heating flow G¾" Heating return G¾" Cylinder flow G¾" Cold water connection with connection elbow G¾" View from below 13 COMFORTLINE GAS CONDENSING BOILERS

SPECIFICATION CGW-2 14/100L 20/120L 24/140L Energy efficiency class, central heating A A A Energy efficiency class, DHW heating A A A Rated heating output at 80/60 C kw 13.5 18.9/22.2 1) 23.8/27.1 1) Rated heating output at 50/30 C kw 15.2 20.4 25.8 Rated heat input kw 14.0 19.6/23.0 24.6/28.0 Lowest heating output (modulating) at 80/60 C kw 1.8/4.6 2) 3.8/6.8 2) 4.8/6.8 2) Lowest heating output (modulating) at 50/30 C kw 2.1/5.4 2) 4.4/7.4 2) 5.6/7.4 2) Lowest heat input (modulating) kw 1.9/4.9 2) 3.9/6.9 2) 4.9/6.9 2) Heating flow connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) Heating return connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) DHW connection G ½" ½" ½" Cold water connection / DHW circulation G ¾" ¾" ¾" Gas connection R ½" ½" ½" Air/flue pipe connection mm 60/100 60/100 60/100 Dimensions Depth 378 mm Width 800 mm Height 790 mm Air/flue gas routing Type B23 P, B33 P, C13(x), C33(x), C43(x), C53(x),C63(x), C83(x), C93(x) Gas category II 2N3B/P Gas connection values Natural gas E/H (net cv = 9.5 kwh/m³ = 34.2 MJ/m³) m³/h 1.44 2.06/2.42 2.52/2.95 Natural gas LL (net cv = 8.6 kwh/m³ = 31.0 MJ/m³) m³/h 1.59 2.28/2.67 2.79/3.25 LPG P (net cv = 12.8 kwh/m³ = 46.1 MJ/m³) kg/h 1.07 1.53/1.80 1.87/2.19 Supply pressure, natural gas (permissible min./max.) mbar 20 (17-25) Supply pressure, LPG gas (permissible min./max.) mbar 30 (25-35) Standard seasonal efficiency [to DIN] at 40/30 C (net cv/gross cv) % 110/99 Standard seasonal efficiency [to DIN] at 75/60 C (net cv/gross cv) % 107/96 Efficiency at rated load at 80/60 C (net cv/gross cv) % 98/88 Efficiency at 30 % partial load and TR = 30 C (net cv/gross cv) % 108/97 Flow temperature, factory setting C 75 Flow temperature up to approx. C 90 Max. total pressure bar 3.0 Max. residual head for heating circuit: High efficiency pump (EEI <0.23) 600 l/h flow rate (14 kw at t=20 K) mbar 550 860 l/h flow rate (20 kw at t=20 K) mbar - 430 1030 l/h flow rate (24 kw at t=20 K) mbar - - 280 Max. permissible total pressure, DHW bar 10 DHW temperature range (adjustable) C 15-65 Water capacity of heating water heat exchanger l 1.3 Nominal capacity of stratification cylinder / equivalent nominal capacity l 44 / 100 44 / 120 44 / 140 Spec. water throughput D at T = 30 K l/min 14.3 18.0 20 Continuous DHW output l/h (kw) 366 (14.6) 560 (23.1) 684 (27.8) Output factor to DIN 4708 N L 0.8 1.1 1.5 DHW output l/10 min 115 150 171 Standby heat loss to EN 12897 kwh/24 h 0.8 Corrosion protection, DHW heat exchanger / cylinder Stainless steel Expansion vessel, total capacity l 10 Expansion vessel, pre-charge pressure bar 0.75-0.95 Flue gas temperature 80/60-50/30 at Qmax C 62-45 70-50 76-50 Flue gas temperature 80/60-50/30 at Qmin C 30-25 30-25 33-27 Flue gas mass flow rate at Qmax g/s 6.2 8.8/10.7 1) 10.9/13.0 1) Flue gas mass flow rate at Qmin g/s 0.9 1.8 2.3 Available gas fan draught at Qmax Pa 125 135 180 Available gas fan draught at Qmin Pa 10 14 17 Flue gas category G 52 NOx class 5 Amount of condensate at 50/30 C l/h appr. 1.4 appr. 2.0 appr. 2.4 Condensate ph value appr. 4.0 Power consumption on standby W 3 Maximum power consumption W 17-45/93 1) 17-51/110 1) 17-62/135 1) IP rating IP IP X4D Electrical connection/fuse protection 230 V / 50 Hz / 16 A/B Total weight kg 54 (35+19) 1) Heating mode/dhw mode 2) Natural gas/lpg (G31) 14

DIMENSIONS + CONNECTION DIMENSIONS CGW-2 CGW-2 CGW-2 261(*202) 261(*202) 165(*106) 165(*106) 84 84 70 70 Ø 80/125 Ø 60/100 190 190 Ø 80/125 Ø 60/100 344 344 214 214 120 120 40 40 31 31 54 54 84 84 654 654 790 790 100100 100100 220 220 440 440 800 800 180 180 280 280 48 48 140 140 178 178 378 378 Front view Side view View from below Drain & fill valve 18.07.14 18.07 DHW circulation connection G¾" 92 3792 Cold water connection G¾" DHW connection G½" Heating return G¾" Gas connection R½" Heating flow G¾" Catia 15 COMFORTLINE GAS CONDENSING BOILERS

SPECIFICATION CGS-2 14/120L 20/160L 24/200L Energy efficiency class, central heating A A A Energy efficiency class, DHW heating A A A Rated heating output at 80/60 C kw 13.5 18.9/22.2 1) 23.8/27.1 1) Rated heating output at 50/30 C kw 15.2 20.4 25.8 Rated heat input kw 14.0 19.6/23.0 24.6/28.0 Lowest heating output (modulating) at 80/60 C kw 1.8/4.6 2) 3.8/6.8 2) 4.8/6.8 2) Lowest heating output (modulating) at 50/30 C kw 2.1/5.4 2) 4.4/7.4 2) 5.6/7.4 2) Lowest heat input (modulating) kw 1.9/4.9 2) 3.9/6.9 2) 4.9/6.9 2) Heating flow connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) Heating return connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) DHW connection G ½" ½" ½" Cold water connection / DHW circulation G ¾" ¾" ¾" Gas connection R ½" ½" ½" Air/flue pipe connection mm 60/100 60/100 60/100 Dimensions Depth 378 mm Width 600 mm Height 1462 mm Air/flue gas routing Type B23 P, B33 P, C13(x), C33(x), C43(x), C53(x),C63(x), C83(x), C93(x) Gas category II 2N3B/P Gas connection values Natural gas E/H (net cv = 9.5 kwh/m³ = 34.2 MJ/m³) m³/h 1.44 2.06/2.42 2.52/2.95 Natural gas LL (net cv = 8.6 kwh/m³ = 31.0 MJ/m³) m³/h 1.59 2.28/2.67 2.79/3.25 LPG P (net cv = 12.8 kwh/m³ = 46.1 MJ/m³) kg/h 1.07 1.53/1.80 1.87/2.19 Supply pressure, natural gas (permissible min./max.) mbar 20 (17-25) Supply pressure, LPG gas (permissible min./max.) mbar 30 (25-35) Standard seasonal efficiency [to DIN] at 40/30 C (net cv/gross cv) % 110/99 Standard seasonal efficiency [to DIN] at 75/60 C (net cv/gross cv) % 107/96 Efficiency at rated load at 80/60 C (net cv/gross cv) % 98/88 Efficiency at 30 % partial load and TR = 30 C (net cv/gross cv) % 108/97 Flow temperature, factory setting C 75 Flow temperature up to approx. C 90 Max. total pressure bar 3.0 Max. residual head for heating circuit: High efficiency pump (EEI <0.23) 600 l/h flow rate (14 kw at t=20 K) mbar 550 860 l/h flow rate (20 kw at t=20 K) mbar - 430 1030 l/h flow rate (24 kw at t=20 K) mbar - - 280 Max. permissible total pressure, DHW bar 10 DHW temperature range (adjustable) C 15-65 Water capacity of heating water heat exchanger l 1.3 Nominal capacity of stratification cylinder / equivalent nominal capacity l 90 / 120 90 / 160 90 / 200 Spec. water throughput D at T = 30 K l/min 18.7 23.2 25.2 Continuous DHW output l/h (kw) 366 (14.6) 560 (23.1) 684 (27.8) Output factor to DIN 4708 N L 1.3 2.1 2.5 DHW output l/10 min 161 199 215 Standby heat loss to EN 12897 kwh/24 h 1.0 Corrosion protection, DHW heat exchanger / cylinder Stainless steel / two-layer enamel coating to DIN 4753 Expansion vessel, total capacity l 10 Expansion vessel, pre-charge pressure bar 0.75-0.95 Flue gas temperature 80/60-50/30 at Qmax C 62-45 70-50 76-50 Flue gas temperature 80/60-50/30 at Qmin C 30-25 30-25 33-27 Flue gas mass flow rate at Qmax g/s 6.2 8.8/10.7 1) 10.9/13.0 1) Flue gas mass flow rate at Qmin g/s 0.9 1.8 2.3 Available gas fan draught at Qmax Pa 125 135 180 Available gas fan draught at Qmin Pa 10 14 17 Flue gas category G 52 NOx class 5 Amount of condensate at 50/30 C l/h appr. 1.4 appr. 2.0 appr. 2.4 Condensate ph value appr. 4.0 Power consumption on standby W 3 Maximum power consumption W 17-45/93 1) 17-51/110 1) 17-62/135 1) IP rating IP IP X4D Electrical connection/fuse protection 230 V / 50 Hz / 16 A/B Total weight kg 84 (35+49) 1) Heating mode/dhw mode 2) Natural gas/lpg (G31) 16

DIMENSIONS + CONNECTION DIMENSIONS CGS-2L CGS-2L CGS-2L CGS-2L 66 1462 264 264 180(*121) 180(*121) 84 84 41.5 41.5 41.5 00 454 400 300 200 151 824 70 66 Drain outlet R½" 204 156 300 824 600 41.5 41.5 272 272 272 282 204 204 151 452 204 600 454 400 454 300 400 200 300 156 200 Front view 272 282 452 300 156 300 Ø 80/125 Ø 60/100 70 70 66 109 66 151 151 262 262 190 824 824 204 204 85 65 SW22 109 563 635 272 282 272 282 452 452 85 Ø 80/125 Ø 60/100 65 646 SW22 563 635 Side view 726 190 109 646 109 262 262 726 85 85 65 691 Heating flow G¾" 65 SW22 563 SW22 635 563 635 Gas connection R½" 190 DHW connection G½" DHW circulation connection G¾" 190 691 646 646 Back view 726 Cold water connection G¾" Heating return G¾" 726 617 16.07.13 Trm 16.07.13 Trm 02 02 01.12.16 A10 01.12.16 A10 02 01.12.16 A10 Catia V5 R19 Catia V5 R19 02 01.12.16 A10 A3 Maßsta TEG-TRM 672 684 691 617 1:5 691 MA 3063612_M MA 16 2 8614 1 Top view 17 COMFORTLINE GAS CONDENSING BOILERS

SPECIFICATION CGS-2 14/150R 20/150R 24/150R Energy efficiency class, central heating A A A Energy efficiency class, DHW heating A A A Rated heating output at 80/60 C kw 13.5 18.9/22.2 1) 23.8/27.1 1) Rated heating output at 50/30 C kw 15.2 20.4 25.8 Rated heat input kw 14.0 19.6/23.0 24.6/28.0 Lowest heating output (modulating) at 80/60 C kw 1.8/4.6 2) 3.8/6.8 2) 4.8/6.8 2) Lowest heating output (modulating) at 50/30 C kw 2.1/5.4 2) 4.4/7.4 2) 5.6/7.4 2) Lowest heat input (modulating) kw 1.9/4.9 2) 3.9/6.9 2) 4.9/6.9 2) Heating flow connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) Heating return connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) DHW connection G ½" ½" ½" Cold water connection / DHW circulation G ¾" ¾" ¾" Gas connection R ½" ½" ½" Air/flue pipe connection mm 60/100 60/100 60/100 Dimensions Depth 635 mm Width 600 mm Height 1792 mm Air/flue gas routing Type B23 P, B33 P, C13(x), C33(x), C43(x), C53(x),C63(x), C83(x), C93(x) Gas category II 2N3B/P Gas connection values Natural gas E/H (net cv = 9.5 kwh/m³ = 34.2 MJ/m³) m³/h 1.44 2.06/2.42 2.52/2.95 Natural gas LL (net cv = 8.6 kwh/m³ = 31.0 MJ/m³) m³/h 1.59 2.28/2.67 2.79/3.25 LPG P (net cv = 12.8 kwh/m³ = 46.1 MJ/m³) kg/h 1.07 1.53/1.80 1.87/2.19 Supply pressure, natural gas (permissible min./max.) mbar 20 (17-25) Supply pressure, LPG gas (permissible min./max.) mbar 30 (25-35) Standard seasonal efficiency [to DIN] at 40/30 C (net cv/gross cv) % 110/99 Standard seasonal efficiency [to DIN] at 75/60 C (net cv/gross cv) % 107/96 Efficiency at rated load at 80/60 C (net cv/gross cv) % 98/88 Efficiency at 30 % partial load and TR = 30 C (net cv/gross cv) % 108/97 Flow temperature, factory setting C 75 Flow temperature up to approx. C 90 Max. total pressure bar 3.0 Max. residual head for heating circuit: High efficiency pump (EEI <0.23) 600 l/h flow rate (14 kw at t=20 K) mbar 550 860 l/h flow rate (20 kw at t=20 K) mbar - 430 1030 l/h flow rate (24 kw at t=20 K) mbar - - 280 Max. permissible total pressure, DHW bar 10 DHW temperature range (adjustable) C 15-65 Water capacity of heating water heat exchanger l 1.3 Nominal capacity of cylinder with internal indirect coil l 145 Spec. water throughput D at T = 30 K l/min 19.7 21.4 21.7 Continuous DHW output l/h (kw) 324 (13.6) 555 (22.6) 612 (25) Output factor to DIN 4708 N L 1.7 2.0 2.2 DHW output l/10 min 162 176 182 Standby heat loss to EN 12897 kwh/24 h 1.47 Corrosion protection, DHW heat exchanger / cylinder Stainless steel / two-layer enamel coating to DIN 4753 Expansion vessel, total capacity l 10 Expansion vessel, pre-charge pressure bar 0.75-0.95 Flue gas temperature 80/60-50/30 at Qmax C 62-45 70-50 76-50 Flue gas temperature 80/60-50/30 at Qmin C 30-25 33-27 Flue gas mass flow rate at Qmax g/s 6.2 8.8/10.7 1) 10.9/13.0 1) Flue gas mass flow rate at Qmin g/s 0.9 1.8 2.3 Available gas fan draught at Qmax Pa 125 135 180 Available gas fan draught at Qmin Pa 10 14 17 Flue gas category G 52 NOx class 5 Amount of condensate at 50/30 C l/h appr. 1.4 appr. 2.0 appr. 2.4 Condensate ph value appr. 4.0 Power consumption on standby W 3 Maximum power consumption W 17-49/59 1) 17-51/63 1) 17-62/88 1) IP rating IP IP X4D Electrical connection/fuse protection 230 V / 50 Hz / 16 A/B Total weight kg 115 (35+80) 1) Heating mode/dhw mode 2) Natural gas/lpg (G31) 18

CGS-2R CGS-2R DIMENSIONS + CONNECTION DIMENSIONS CGS-2R CGS-2R 180(*121) 264 70 180(*121) 1792 70 1792 Ø 80/125 Ø 60/100 70 1792 262 85 190 262 85 Ø 80/125 Ø 60/100 190 262 85 190 A3 M TEG- 65 1152 Drain outlet R½" 66 1152 1152 65 974 1054 65 974 66 1054 946 974 1054 946 946 1000 66 946 1000 1014 5 W22 00 454 400 300 200 204 156 300 SW22 600 41.5 41.5 272 454 400 300 200 204 151 156 204 272 282 300 41.5 SW22 600 Front view 454 400 300 200 151 452 156 204 272 282 300 41.5 109 452 151 204 272 282 109 563 635 452 563 109 635 Side view 563 635 Cold water connection G¾" DHW connection G½" DHW circulation connection G¾" Heating flow G¾" Gas connection R½" Back view 14.07.14 Trm 10500051 Heating return G¾" 1:10 14.07.14 Trm MA 306361 14.07.14 10500051 86 105 Catia V5 R19 Catia V5 R19 Catia V5 Top view 19 COMFORTLINE GAS CONDENSING BOILERS

SPECIFICATION CSZ-2 14/300R 20/300R 24/300R Energy efficiency class, central heating A A A Energy efficiency class, DHW heating A A A Rated heating output at 80/60 C kw 13.5 18.9/22.2 1) 23.8/27.1 1) Rated heating output at 50/30 C kw 15.2 20.4 25.8 Rated heat input kw 14.0 19.6/23.0 24.6/28.0 Lowest heating output (modulating) at 80/60 C kw 1.8/4.6 2) 3.8/6.8 2) 4.8/6.8 2) Lowest heating output (modulating) at 50/30 C kw 2.1/5.4 2) 4.4/7.4 2) 5.6/7.4 2) Lowest heat input (modulating) kw 1.9/4.9 2) 3.9/6.9 2) 4.9/6.9 2) Heating flow connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) Heating return connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20) DHW connection G ½" ½" ½" Cold water connection / DHW circulation G ¾" ¾" ¾" Gas connection R ½" ½" ½" Air/flue pipe connection mm 60/100 60/100 60/100 Dimensions Depth 1013 mm Width 600 mm Height 1785 mm Air/flue gas routing Type B23 P, B33 P, C13(x), C33(x), C43(x), C53(x),C63(x), C83(x), C93(x) Gas category II 2N3B/P Gas connection values Natural gas E/H (net cv = 9.5 kwh/m³ = 34.2 MJ/m³) m³/h 1.44 2.06/2.42 2.52/2.95 Natural gas LL (net cv = 8.6 kwh/m³ = 31.0 MJ/m³) m³/h 1.59 2.28/2.67 2.79/3.25 LPG P (net cv = 12.8 kwh/m³ = 46.1 MJ/m³) kg/h 1.07 1.53/1.80 1.87/2.19 Supply pressure, natural gas (permissible min./max.) mbar 20 (17-25) Supply pressure, LPG gas (permissible min./max.) mbar 30 (25-35) Standard seasonal efficiency [to DIN] at 40/30 C (net cv/gross cv) % 110/99 Standard seasonal efficiency [to DIN] at 75/60 C (net cv/gross cv) % 107/96 Efficiency at rated load at 80/60 C (net cv/gross cv) % 98/88 Efficiency at 30 % partial load and TR = 30 C (net cv/gross cv) % 108/97 Flow temperature, factory setting C 75 Flow temperature up to approx. C 90 Max. total pressure bar 3.0 Max. residual head for heating circuit: High efficiency pump (EEI <0.23) 600 l/h flow rate (14 kw at t=20 K) mbar 550 860 l/h flow rate (20 kw at t=20 K) mbar - 430 1030 l/h flow rate (24 kw at t=20 K) mbar - - 280 Max. permissible total pressure, DHW bar 10 DHW temperature range (adjustable) C 15-65 Water capacity of the heat exchanger, heating/solar l 6.6 / 8.8 Nominal cylinder capacity l 285 Spec. water throughput D at T = 30 K l/min 20.5 24.5 24.5 Continuous DHW output l/h (kw) 366 (14.6) 560 (23.1) 684 (27.8) Output factor to DIN 4708 N L 1.5 2.3 2.3 DHW output l/10 min 175 210 210 Standby heat loss to EN 12897 kwh/24 h 2.3 Cylinder corrosion protection Two-layer enamel coating to DIN 4753 Expansion vessel, total capacity l 10 Expansion vessel, pre-charge pressure bar 0.75-0.95 Flue gas temperature 80/60-50/30 at Qmax C 62-45 70-50 76-50 Flue gas temperature 80/60-50/30 at Qmin C 30-25 33-27 Flue gas mass flow rate at Qmax g/s 6.2 8.8/10.7 1) 10.9/13.0 1) Flue gas mass flow rate at Qmin g/s 0.9 1.8 2.3 Available gas fan draught at Qmax Pa 125 135 180 Available gas fan draught at Qmin Pa 10 14 17 Flue gas category G 52 NOx class 5 Amount of condensate at 50/30 C l/h appr. 1.4 appr. 2.0 appr. 2.4 Condensate ph value appr. 4.0 Power consumption on standby W 3 Maximum power consumption W 17-49/59 1) 17-51/63 1) 17-62/88 1) IP rating IP IP X4D Electrical connection/fuse protection 230 V / 50 Hz / 16 A/B Total weight kg 160 (35+125) 1) Heating mode/dhw mode 2) Natural gas/lpg (G31) 20

(*139) 282 198 (*139) CSZ-2R DIMENSIONS + CONNECTION DIMENSIONS CSZ-2R CSZ-2R 814 190 814 190 890 955 1785 1855 1984 2068 1785 1855 1984 2068 440 604 457 372 302 232 440 604 457 372 302 Front view 232 668 748 828 908 668 748 828 908 232 302 372 584 997 232 302 372 584 997 Top view Side view 22.07.14 Lan 22 21 COMFORTLINE GAS CONDENSING BOILERS

SPECIFICATION CSW 120 Cylinder energy efficiency class Cylinder capacity l 115 Continuous cylinder output (80/60 10/45 C) kw l/h 29-710 Standby heat loss kwh/24 h 1.11 Output factor N L 1.0 Permissible operating pressure, DHW bar 10 Permissible operating pressure, heating water bar 12 Max. permissible cylinder water temperature C 95 Max. permissible heating water temperature C 110 Cold water connection G ¾" DHW connection G ¾" Cylinder flow R ¾" Cylinder return R ¾" DHW circulation G ¾" Drain outlet R ½" Sensor well Ø mm 12 Dry weight kg 65 B 22

CSW-120 DIMENSIONS + CONNECTION DIMENSIONS CSW-120 440 344 1800-1950 CSW-120 154 144 120 542 790 810 122 175 270-420 Drain outlet R½" Front view Top view DHW connection G¾" DHW circulation G¾" Cold water connection G¾" Cylinder flow R¾" Cylinder return R¾" Cleaning aperture with protective anode Sensor well Ø 12 mm Top view 23 COMFORTLINE GAS CONDENSING BOILERS

STANDARD CONTROL UNIT The operation of a CGB-2(K)/CGW-2/CGS-2/CSZ-2 gas condensing boiler requires either an AM display module or a BM-2 programming unit. AM or BM-2 The AM functions solely as a display module for the heat generator. Appliance-specific parameters and values can be programmed and displayed. AM display module Display module for the heat generator Only required if BM-2 is used as a remote control or in a cascade circuit Operated by rotary selector with pushbutton function 4 quick start keys for frequently used functions Backlit LCD AM is always inside the heat generator BM-2 programming unit in black and white weather-compensated flow temperature Time programs for heating, DHW and DHW circulation 3.5" colour display Easy user prompts via plain text display Operated by rotary selector with pushbutton function 4 function keys for frequently used functions microsd card slot for software update Installation either inside the boiler control unit or in wall mounting base as a remote control Only one programming unit required for multi boiler systems Can be extended with MM-2 mixer module (up to 7 heating circuits with mixer) Part of the standard delivery for CSZ-2 BM-2 can also be used as a remote control for the CWL Excellent ventilation unit (one programming unit for heating and ventilation) 2-wire ebus connection AM display module or BM-2 programming unit; an essential requirement BM-2 programming unit in black or white (if BM-2 is inside the heat generator, max. 6 additional remote controls are possible) 24

CGB-2(K) / CGW-2 / CGS-2 / CSZ-2 CONTROL ACCESSORIES MM-2 mixer module Extension module to control one circuit with mixer Weather-compensated flow temperature control Easy controller configuration by selecting one of the preset system versions 1... 7 BM-2 programming unit with wall mounting base can be extended to serve as a remote control Rast 5 connection technology Incl. flow temperature sensor 2-wire ebus connection SM1-2 solar module Extension module to control one solar circuit incl. collector temperature sensor, cylinder temperature sensor and sensor wells In conjunction with WOLF heat generators, greater energy savings through intelligent cylinder reheating, i.e. blocking cylinder reheating when there is sufficient solar energy Heat metering with external heat meter Function check for flow rate and gravity brake Temperature differential control for one heat consumer Maximum cylinder temperature limit Indication of set and actual values on the BM-2 programming unit Integral hours run meter ebus interface with automatic energy management Rast 5 connection technology Part of the standard delivery for CSZ-2 SM2-2 solar module Extension module to control one solar thermal system with up to 2 cylinders and 2 collector arrays, incl. 1 collector sensor and 1 cylinder sensor, each with sensor well Easy controller configuration by selecting one of the preset system versions In conjunction with WOLF heat generators, greater energy savings through intelligent cylinder reheating, i.e. blocking cylinder reheating when there is sufficient solar energy Heat metering with external heat meter for all configurations Selection of cylinder operating mode Indication of set and actual values on the BM-2 programming unit ebus interface with automatic energy management Rast 5 connection technology KM-2 cascade module Extension module to control systems with a low loss header or cascade operation Suitable for wall mounted gas condensing boilers (4 appliances) Easy controller configuration by selecting one of the preset system versions Switching of one heating circuit with mixer BM-2 programming unit slots into wall mounting base and can be extended to serve as a remote control 0-10 V input for BMS systems; 230 V fault message output ebus interface with automatic energy management Rast 5 connection technology 25 COMFORTLINE GAS CONDENSING BOILERS

CGB-2(K) / CGW-2 / CGS-2 / CSZ-2 CONTROL ACCESSORIES Wireless outside temperature sensor (only in conjunction with receiver for wireless outside temperature sensor and remote control, part no. 27 44 209) Wireless receiver for wireless outside temperature sensor and wireless remote control incl. radio clock (DCF77 signal) Wireless remote control (only in conjunction with receiver for wireless outside temperature sensor and remote control) Max. one wireless remote control per circuit with mixer. 2-wire ebus connection AFB analogue remote control Simple WRS remote control for heating circuits and circuits with mixer Each heating circuit can be operated separately with a remote control Integral room temperature sensor Temperature and program selection via rotary selector Only in conjunction with BM-2 programming unit ISM 6 LON interface module For communication between the control unit and the building management system using LON standard network variables ISM8i Ethernet interface module Interface module with disclosed TCP/IP protocol for system-independent integration of WOLF heating appliances and ventilation units. KNX interface set Interface set for integration of WOLF heat generators into a KNX network Comprising: ISM8i interface module, KNX-IP-BAOS module, installation/operating instructions, network cable I/O module Extension module for 2 programmable inputs and outputs 26

CGB-2(K) / CGW-2 / CGS-2 / CSZ-2 CONTROL ACCESSORIES WOLF LINK HOME LAN / WLAN interface for accessing the control unit via the internet or a local network. Operation via ios, Android or the WOLF portal. Installation in the appliance control unit. Local (home) network WOLF heat generator with Wolf Link home interface module WOLF portal server WLAN LAN / WLAN DSL router (LAN / WLAN) LAN 2-wire ebus connection LAN / WLAN Wolf Link home enables WOLF heat generators to be integrated into the SmartHome system from wibutler. In combination with the Smart Home system provider s room sensors and thermostats, the set enables demand-driven individual room temperature control via flow temperature adaptation based on the actual heat demand of the occupants and the structural conditions of the house. At the same time, the SmartHome set enables contractors to carry out remote maintenance and diagnostics via the WOLF internet portal. Local (home) network WOLF portal server WLAN LAN / WLAN DSL router (LAN / WLAN) LAN LAN / WLAN WOLF heat generator with ISM9i interface module 27 COMFORTLINE GAS CONDENSING BOILERS

AIR/FLUE GAS ROUTING FOR WALL MOUNTED GAS CONDENSING BOILERS CGB-2(K) / CGW-2 / CGS-2 / CSZ-2 Provide ventilation for B23, B33, C53 28

AIR/FLUE GAS ROUTING FOR WALL MOUNTED GAS CONDENSING BOILERS CGB-2(K) / CGW-2 / CGS-2 / CSZ-2 Design variants Type B23 B33 B33 C13x C33x C43x C53 C53x Flue pipe in a shaft and combustion air directly via the appliance (open flue) Flue pipe in a shaft with horizontal concentric connection pipe (open flue) Connection to a moisture-resistant flue gas chimney with a horizontal concentric connection pipe (open flue) Horizontal roof outlet through a pitched roof (room sealed on-site dormer) Vertical concentric roof outlet through pitched or flat roof, vertical concentric balanced flue system for installation in a shaft (room sealed) Connection to a moisture-resistant balanced flue chimney, maximum pipe length from centre of boiler bend to connection 2 m (room sealed) Connection to flue in a shaft and ventilation air supply through external wall (room sealed), 3 m ventilation air pipe incl. Connection to flue routed over an external wall, combustion air intake via external wall (room sealed) CGB-2-14 CGW-2-14 CGS-2-14 CSZ-2-14 Maximum length 1) [m] CGB-2(K)-20 CGW-2-20 CGS-2-20 CSZ-2-20 CGB-2(K)-24 CGW-2-24 CGS-2-24 CSZ-2-24 DN 60 45 25 21 DN 80-50 50 DN 60 43 23 19 DN 80 50 50 50 Calculation to EN 13384 (balanced flue chimney manufacturer) DN 60/100 10 10 10 DN 80/125 10 10 10 DN 60/100 16 14 12 DN 80/125 17 22 26 DN 110/160 18 25 30 Calculation to EN 13384 (balanced flue chimney manufacturer) DN 80/125 50 50 50 DN 60/100 46 24 20 DN 80/125-50 50 C83x Connection to flue in a shaft and ventilation air through external wall (room sealed) DN 80/125 50 50 50 C83x C93x C93x Concentric connection to moisture-resistant flue gas chimney and combustion air through external wall (room sealed) Flue pipe for installation in a shaft Connection pipe DN 60/100, vertical DN 60 Flue pipe for installation in a shaft Connection pipe DN 60/100 or DN 80/125, vertical DN 80 1) The maximum length refers to the total length from the appliance to the flue terminal Calculation to EN 13384 (balanced flue chimney manufacturer) rigid 17 17 17 flexible 13 13 13 rigid 18 21 26 flexible 14 17 22 Note: Systems C33x and C83x are also suitable for installation in garages. The calculation was made taking the pressure conditions into account (geodetic height: 325 m). Where necessary, adapt the installation examples to the relevant building regulations and requirements in your country/region. Any questions relating to the installation, particularly regarding the provision of inspection components and ventilation apertures (ventilation generally required above 50 kw output) should be raised with your local flue gas inspector prior to installation. The specified lengths refer to concentric balanced flues and standard flues, and apply to original WOLF components only. Balanced flue systems DN 60/100, DN 80/125 and DN 110/160 are certified as systems together with WOLF wall mounted gas condensing boilers. The following balanced flues or standard flues with CE-0036- CPD-9169003 certification may be used: - Flue DN 60, DN 80, DN 110, DN 125 and DN 160 - Concentric balanced flue DN 60/100, DN 80/125 and DN 110/160 - Concentric balanced flue (on an external wall) DN 80/125 - Flexible flue DN 60, DN 83 and DN 110 WOLF accessories are supplied with the necessary identification labels. Please also observe the installation information supplied with the accessories. Calculating the length of the air/flue gas routing The calculated length of the balanced flue or standard flue is derived from the straight pipe length and the length equivalent of any pipe bends. Example: Length of straight balanced flue pipe = 1.5 m 87 bend = 2.0 m 2 x 45 bends = 2 x 1.2 m L = 1.5 m + 1 x 2.0 m + 2 x 1.2 m L = 5.9 m Bend Type Calculated length [m] 30 Single wall 0.4 45 Single wall 0.6 87 Single wall 1.0 30 Concentric 0.7 45 Concentric 1.2 87 Concentric 2.0 29 COMFORTLINE GAS CONDENSING BOILERS

COMFORTLINE WALL MOUNTED GAS CONDENSING BOILERS ACCESSORIES CGB-2 CGB-2K CGW-2 CGS-2L CGS-2R CSZ-2 Wall mounted gas condensing boiler for central heating with option to connect a DHW cylinder Wall mounted gas condensing boiler for DHW and central heating Gas condensing centre for DHW and central heating with wall mounted stainless steel stratification cylinder Gas condensing centre for DHW and central heating with enamelled steel stratification cylinder Gas condensing centre for DHW and central heating with enamelled steel DHW cylinder with indirect coil Gas condensing solar centre in modular form for DHW and central heating Tested in accordance with EC directives and EN 483 for heating systems according to EN 12828 with flow temperatures up to 90 C and 3 bar permissible operating pressure. Suitable for modulating operation down to room temperature; modulating output control; gas-adaptive, self-calibrating combustion controller for extremely clean combustion and fluctuating gas qualities. Premix burner suitable for natural gas E, LL or LPG; sealed combustion chamber for open flue and room sealed operation. Control unit with gas burner control unit, electronic ignition and ionisation flame monitor; variable speed fan. White RAL 9016 powder-coated casing. Accessories CGB-2-14 -20-24 CGB-2 with CSW-120 CGB-2K -20-24 CGW-2-14/100L -20/120L -24/140L CGS-2-14/120L -20/160L -24/200L CGS-2-14/150R -20/150R -24/150R CSZ-2-14/300R -20/300R -24/300R Control accessories AM display module BM-2 programming unit Wall mounting base AFB analogue remote control MM-2 mixer module SM1-2 solar module SM2-2 solar module KM-2 cascade module Heat meter set for capturing solar yield Wireless receiver for wireless outside temperature sensor and wireless remote control incl. radio clock (DCF77 signal) Wireless outside temperature sensor Wireless remote control WOLF Link home / pro - LAN/WLAN interface module incl. PC software Included in standard delivery Optional accessory 30

COMFORTLINE WALL MOUNTED GAS CONDENSING BOILERS ACCESSORIES Accessories CGB-2-14 -20-24 CGB-2 with CSW-120 CGB-2K -20-24 CGW-2-14/100L -20/120L -24/140L CGS-2-14/120L -20/160L -24/200L CGS-2-14/150R -20/150R -24/150R CSZ-2-14/300R -20/300R -24/300R Hydraulic accessories and gas supply accessories Gas ball valve (angle or straight-through version), chrome plated, with thermally activated shut-off valve Safety valve Rp½" up to 3 bar Drain outlet kit R1" with trap and bezel, grey plastic Filling device Accessories for concealed installation Angle maintenance valve G¾", chrome plated Angle maintenance valve G¾" with connection R½" for safety valve, chrome plated DHW connector G½", chrome plated Cold water connector G½", chrome plated Connection set for concealed installation DHW connection set with or without pressure reducer Accessories for surface mounting Straight-through maintenance valve Rp¾", chrome plated Straight-through maintenance valve Rp¾" with connection R½" for safety valve, chrome plated DHW connector R½", chrome plated Cold water connector R½", chrome plated Connection set for surface mounting Pre-assembled connection set for surface mounting DHW connection set with or without pressure reducer Included in standard delivery Optional accessory 31 COMFORTLINE GAS CONDENSING BOILERS

COMFORTLINE WALL MOUNTED GAS CONDENSING BOILERS ACCESSORIES Accessories CGB-2-14 -20-24 CGB-2 with CSW-120 CGB-2K -20-24 CGW-2-14/100L -20/120L -24/140L CGS-2-14/120L -20/160L -24/200L CGS-2-14/150R -20/150R -24/150R CSZ-2-14/300R -20/300R -24/300R Accessories for connection sets Solar heating connection set for the additional control of a solar cylinder Set for solar integration Partially pre-assembled gas condensing centre pipework connection set for connection to heating flow/return, DHW/cold water, gas Flow and return connection set for heating and solar circuit and gas supply DHW/cold water connection set with thermostatic water mixer and high efficiency DHW circulation pump DHW circulation accessories High efficiency DHW circulation pump Other accessories Pipe cladding Height-adjustable support platform for unfinished floors Impressed current anode Solar heat meter set CSW-120 DHW cylinder Balanced flue accessories Concentric balanced flue External wall system Flue system connection set for flues in a shaft Included in standard delivery Optional accessory 32

33 COMFORTLINE GAS CONDENSING BOILERS NOTES