WineZone Ceiling Mount Ductless Split 15

Similar documents
Wine Zone Ductless Split System

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD!

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Horizontal/Side Discharge Condensing Units

INSTRUCTIONS! DO NOT DISCARD!

Installation Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

PLATINUM SPLIT TWIN TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Installation Instructions

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Condensing Unit Installation and Operating Instructions

Installation Instructions

Installation Manual BCS2000/3000

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

HEAT PUMP INSTALLATION MANUAL

Platinum Split TECH MANUAL

Installation Instructions

Installation Manual BCS 1000/1500

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Split Floor-Mounted Cooling System Operation Care Installation Manual

CEILING MOUNT. VERSION 2 TECHNICIAN'S MANUAL 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

CM2500 VERSION 2 TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option

MAGNUM SERIES OWNER S MANUAL. Magnum SS9000 Magnum SS12000 QS

Installation Instructions

Read and save these instructions

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

Installation Instructions

AHG**-0B Series Hydronic Air Handling Units

Condensing Unit Installation and Operating Instructions

Installation Instructions

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Warm Case Troubleshooting Guide 9/18/2014

Service Step by Step Trouble-Shooting Check-List

38LB/38LF AIR COOLED CONDENSING UNIT

an ISO 9001:2008 Registered Company ShortPac HEAT/COOL (05000-QUX-A/05000-VUX-A)

Installation Instructions

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Installation Guide & Owner s Manual. Water Source Heat Pumps Vertical / Horizontal 1 5 Nominal Ton GEOCOOL SERIES

Installation Instructions

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

Room Air Conditioner Service and Parts Manual

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

CEILING MOUNT TWIN TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

Split Refrigeration Systems

PLATINUM SPLIT TECHNICIAN S MANUAL PS The Coolest Thing In Wine Storage

Installation Instructions

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

38GHP AIR-COOLED MULTI SPLIT CONDENSING UNITS

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

EarthLinked AFN Series Air Handlers Installation Manual

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Installation Instructions

Installation Instructions

Installation Instructions

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Residential Piping and Long Line Guideline

Installation Instructions

EarthLinked AVN Series Air Handlers Installation Manual

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

VMH09/12/18/24 SU Series

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

Installation, Start-Up and Service Instructions

Installation Owner Diagnostics

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

C13-Series Engineering Guide

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

Air Conditioning Operation and Troubleshooting Matt Dunham

MODELS E1FB180 & E1FB240

MODELS B1PA024, 030 AND 036

CONDENSING UNITS SPLIT-SYSTEM COOLING 6-1/3 TONS INSTALLATION INSTRUCTION MODELS H*DB076 NOMENCLATURE GENERAL LIMITATIONS INSPECTION REFERENCE

Platinum Split OWNER S MANUAL

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

PACKAGE AIR CONDITIONER

Hoshizaki America, Inc.

Installation, Start-Up and Service Instructions

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL COMMERCIAL SPLIT SYSTEM COOLING UNITS 4 PIPE SYSTEMS 15 THROUGH 20 NOMINAL TON HB B-0804

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Transcription:

WineZone Ceiling Mount Ductless Split 15 Requires an HVAC technician to install and charge with R-22 refrigerant. Easy to install. Unit plugs into wall outlet. Industrial grade unit for longer life. Indoor and outdoor condensers available. Drain line, refrigerant and line sets, and electric supply required.

Supplies and materials needed for installation 1. Refrigeration piping 1/4 liquid line and 3/8 insulated suction line set, not to exceed 80 equivalent feet in length 2. Condenser pad 3. Required electrical services A. Dedicated service for condenser and evaporator B. 2-conductor low voltage from thermostat to condenser control panel 4. R-22 refrigerant for system 5. Miscellaneous hardware, brackets, sealant etc 6. Tools and equipment needed to perform the installation Supplies and Materials Furnished with Equipment 1. Condenser with pre-wired control panel 2. Pre-assembled outdoor upgrade kit, if ordered 3. Ceiling mounted evaporator modified for system 4. Thermostat 5. Filter drier 6. Sight glass 7. Access tees 8. Fan cycle control, mounted and wired. 9. Wiring diagrams 10. 50 line set 11. Installation instructions 12. Warranty information

Refrigerant Piping and Charging Instructions Caution: This Refrigeration Equipment must be installed by a qualified technician 1. Select a suitable location for the evaporator with respect to air circulation, racking, drain, refrigerant and electrical lines. Provide adequate clearance for airflow and maintenance. 2. Place the condenser at the desired location outside the wine cellar in a well-ventilated area or outdoors. Indoor condensers must be placed in a space twice the volume of the wine cellar to prevent excessive condensing temperatures. Check local codes for proper venting of mechanical rooms. Condenser face must be at least 8 from any obstruction and entering air must not exceed 110 F. When installing an outdoor condenser, be sure that it is located so that leaves or snow do not accumulate and block the airflow. This can be accomplished by setting the condenser on a concrete slab, blocks, etc. Place the unit so prevailing winds do not blow rain, snow and debris into the open ends of the outdoor cover. Air directed toward or away from the dwelling may cause undesirable noise for owners and their neighbors. This must be considered when placing the unit outdoors. 3. Install the 1/4 x 3/8 line set. The evaporator and compressor may have different fitting sizes, so some field supplied reducers will be necessary. Insulate the suction line the entire length of the run. Maximum line length is 80 equivalent feet. Long sweep elbows are equivalent to 5 linear feet. Horizontal line runs should slope ½ per 10 ft. towards the condenser for proper oil return. Avoid sags or bends that will trap oil. For installations with vertical height differences greater than 20 feet, consult Tecumseh Engineer Assistance. Line lengths in excess of 80 linear feet may cause compressor damage and will void the warranty. 4. Install the access tee provided on the receiver flare fitting. Place the fan cycle control capillary tube on the access tee and tighten securely. Install the filter dryer and sight glass. Wrap with a wet rag to prevent over heating during brazing. 5. Perform a leak test with dry nitrogen, but never expose the system to leak test pressures greater than 150 PSI. Test all fittings including factory installed flare fittings that may have loosened during shipping. 6. Evacuate the system to 1000 microns for 1 hour. 7. Install electrical wiring according to the Electrical Requirements on page 5 and the appropriate wiring diagram. Follow all applicable codes. 8. After isolating the vacuum pump from the system, break the vacuum to a positive pressure using nameplate refrigerant connected to the liquid line. Add approximately 2 lbs. of refrigerant

9. Complete the charging process with the compressor running and add the balance of the charge into the suction line of the system. Liquid refrigerant should never enter the compressor directly. Set the condenser fan cycle control to pressures acceptable for R-22 in your geographic location. Factory settings are a cut in of 250 with a differential of 50, and are sufficient for most locations. Slowly add refrigerant until the bubbles in the sight glass disappear. The condenser fan motor must be running to complete the charge. 10. After the wine room has reached 55, check the sight glass and gauge readings. The sight glass should be free of bubbles. The suction pressure should be 60 to 65 psi and the superheat should be 6 to 10. At the evaporator, the difference between entering and leaving air should be approximately 8. Each installation is unique. Variations in room design, application, local climate, and electrical supply can affect the system performance. Therefore some adjustments to the recommended settings may be necessary. Cool the room to 55 before making adjustments to the fan cycle control or expansion valve. Always monitor the compressor amp draw with an ammeter when making adjustments. Never allow compressor discharge temperatures to exceed 210 F. Service and Maintenance Service Parts Maintenance Procedures Period Indoor unit Outdoor unit 1. Clean dirt and debris from grille or panel with a soft cloth, soap, and water. 2. Inspect evaporator coil, gently remove, brush off dirt and debris 3. Check drain pan. Wipe or vacuum clean as necessary. Check water flow; blow out drain as necessary. 1. Wash condenser coil with appropriate cleanser and garden hose. Check safety devices. Check refrigerant charge. Check system operation As necessary As necessary Monthly Twice per year By qualified technician

Electrical Requirements 1. Wall receptacle on 110-volt, 15-amp dedicated circuit. 2. Evaporator connects to terminals 3 and 4 in the condenser control panel. 3. Low voltage from Y and R on the thermostat connects to terminals 9 and 10 in the condenser control panel. 4. Each unit must be installed in accordance with the National Electric Code. Check local codes for additional precautions and ordnances to installation. Field Wiring Condensing unit Terminal Board Terminal 1 110 Line voltage from the plug Terminal 2 110 volt neutral from the plug Terminal 3 110 volt hot to the evaporator fan motor Terminal 4 110 volt neutral to the evaporator fan motor Terminal 9 Thermostat Y Terminal 10 Thermostat R System Ground Lug Above Terminal Boards

Installation of the Evaporator The evaporator must be securely mounted on a level ceiling, and placed in such a way as to prevent short cycling of the discharge air with the return air. This location must be suitable for piping and drainage, away from doors or windows, and provide suitable clearance for maintenance. Do not discharge air onto the thermostat. The condensate drain must slope downward, have no traps, and requires an air gap to flow properly. Do not permanently attach or solder drain line to the drain stub. The evaporator fan motor receives load voltage from terminals 3 and 4 in the condenser control panel. No low voltage wiring is required at the evaporator. TA C BTO Motor Info. Dimensions (In.) Connections (In.) Model CFM Qty. FLA L H W Liq. Suct. Drain TA 170 2 1.6 20 1/2 4 1/2 13 1/2 1/2 FN 3/8 ID 1/2 OD C 235 1 1.0 14 1/4 8 7/8 13 3/4 1/2 FN 3/8 ID 1/2 OD BTO 240 2 1.6 19 1/8 5 3/4 16 1/8 1/2 FN 1/2ID 1/2 OD

Legend Symbol Description CCH Crankcase Heater Comp Compressor CR Compressor Relay Evap Evaporator Fan Motor FC Fan Cycle Control GND Ground TB1 Terminal Board One TR Transformer - - - - - - - Field Wiring 110 V Compressor 110 V Evaporator TB1 1 Plug 2 Plug 3 110 V Load voltage to evaporator 4 110 V Neutral to evaporator 5 Compressor 6 Compressor neutral 7 Condenser fan motor 8 9 Thermostat Y 24 V 10 Thermostat R 24 V

BTU Length Width Height Liquid Line Specifications For 1500 BTU Outdoor Condenser Suction Line Shipping Weight Power Supply Min. Circuit Amps 1500 27 20 20 ¼ MF 3/8 MF 93 115/60/1 5.8 15 Max. Fuse Size BTU Length Width Height Liquid Line Specifications for 1500 BTU Indoor Unit Suction Line Shipping Weight Power Supply Min. Circuit Amps 1500 24 20 14 ¼ MF 3/8 MF 60 115/60/1 5.8 15 Max. Fuse Size

Troubleshooting Fault Cause Solution Unit does not run 1. Blown fuse or circuit Replace fuse/reset breaker breaker 2. Room at set point Lower set point 3. Thermostat not calling Lower set point for cooling 4. Faulty thermostat or wiring Call a qualified technician Unit runs but does not cool 1. Lack of air flow Make sure louvers and fan are unobstructed. Clean evaporator if necessary 2. Unit low on charge Call a qualified technician 3. Compressor not running Call a qualified technician 4. Unit undersized Call a qualified technician Evaporator coil freezes Water leaking from unit 1. Coil and/or fan wheel Clean the coil and/or fan dirty wheel 2. Temperature set point Set thermostat to 55 too low 3. Fan cycle cut out set too Call a qualified technician low 4. System low on charge Call a qualified technician 1. Condensate drain Clear out drain clogged 2. Evaporator coil frozen See above Evaporator fan runs but compressor does not 1. Compressor and/or starting components faulty Call a qualified technician Compressor runs but evaporator fan motor does not Compressor short cycles Humidity in cellar too low 1. Faulty fan motor Call a qualified technician 2. Faulty fan relay Call a qualified technician 1. Evaporator blows on Move thermostat thermostat 2. Unit low on charge Call a qualified technician 3. Condensing fan Call a qualified technician motor/capacitor faulty 4. Compressor and/or Call a qualified technician starting components faulty 1. Cellar vapor barrier not Install proper vapor barrier sufficient 2. Insufficient air flow Check evaporator