CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Similar documents
CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E DEHUMIDIFIER (FULL PRODUCT RANGE) OWNER S MANUAL

K100P DEHUMIDIFIER OWNER S MANUAL

CD35 / CD35P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM95 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Operation manual. Dehumidifier CFO-20N

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

LUMBER DRYER LD3000 OWNER S MANUAL

Superdryer Dehumidifiers

EBAC MODEL GENESIS AVENGER APOLLO AIR MOVER OWNER S MANUAL

GL-DEH Series Portable Dehumidifier Operating Instructions

T-Series Air Conditioner T15 Model

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

T-Series Air Conditioner T20 Model

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

T-Series Air Conditioner T53 Model

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Condensing Unit Installation and Operating Instructions

Portable Dehumidifier

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Portable Dehumidifier with Internal Pump

Room Air Conditioner Service and Parts Manual

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Ebac Industrial. Products Limited. military environmental control systems

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER DEUMIDIFICATORE DESHUMIDIFICADOR DESUMIDIFICADOR

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

NEWGATE TECHNOLOGIES, INC.

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

Portable Air Conditioner

AC-12200E Portable Air Conditioner

Owner s Manual Unit Specifications...3 Rating Information...3. Built Right First... To Last! Warning!

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

SERVICE MANUAL. CG2 Commercial Grade Dehumidifier. SLS Part Number

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

ROTARY CONTROL AIR CONDITIONER

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

AIR CONDITIONER ELECTRONIC CONTROL

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

WineZone Ceiling Mount Ductless Split 15

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

USER MANUAL TPS-M5/M55/M555

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

Automatic Ice Maker. Service Manual VT ICEMAKER 15

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Transcription:

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 8 Product Support Questions: Contact Ebac USA at (757) 873 6800 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com

UNPACKING Carefully remove the CD30 dehumidifier unit from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing; it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION The Ebac CD30 industrial dehumidifier removes moisture from the air through the refrigeration process. The Ebac CD30 is basically comprised of: A) A compressor B) A refrigerant evaporator coil C) A refrigerant condenser coil D) One circulation fan E) A drain tray for collecting and disposing of condensed moisture F) A solid state timer for hot gas defrost cycle G) An adjustable membrane-type humidistat H) A cabinet to house the above components The fan draws the moist air through the cold evaporator coil which cools the air below its dew point. Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permanent drain. The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated by the compressor. The air is, therefore discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity, than that which entered. Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area. The CD30 dehumidifier is a rugged reliable drying unit designed to operate effectively over a broad range of temperature and humidity conditions. A powerful and reliable active hot gas defrost system, controlled by an electronic timer, guarantees positive de-icing, thereby optimizing operation at low temperatures. The unit incorporates a welded steel chassis and is finished in an epoxy coating for resilience to damage caused by rough handling. The CD30 dehumidifier is fitted with an adjustable humidistat to enable you to select the level of dryness. Page 2 of 8

SPECIFICATIONS MODEL: CD30 / CD30E HEIGHT: 12 WIDTH: 12 DEPTH: 22 WEIGHT: CD30 50 lbs CD30E - 55 lbs AIRFLOW: 170 CFM MAX OPERATING TEMP: 95ºF POWER SUPPLY: 110V, 60Hz CURRENT: CD30 4 A CD30E 5 A REFRIGERANT TYPE: R134a "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed. The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit, please refer to the product data label" Page 3 of 8

OPERATION The operation of the dehumidifier is to remove moisture from the air by having it condense on the cold tubes of the evaporator coil. The air then passes over the hot condenser coil and returns to the conditioned space slightly warmer and dryer than when it entered the dehumidifier unit. TEST FOR CORRECT OPERATION The following procedures should be followed to test the CD30 for correct operation. 1. After unpacking, examine all external features to confirm damage free shipment. Report all defects and damage at once. 2. Check dehumidification process: a) Place unit on a level surface. b) Start up unit by rotating the adjustable humidistat knob counter clockwise to the minimum setting. Plug in the unit to a grounded receptacle with a 15 amp power source. Rotate the humidistat knob clockwise to the maximum setting. c) Check the compressor is running. d) Leave the machine running for 15 minutes. e) Observe the evaporator coils, to confirm frost formation. i. If the air temperature is below 70ºF, an even coating of frost should cover the entire evaporator coils, except for the last one or two coils. ii. If the temperature is above 70ºF, frost and/or droplets of condensed water should cover the entire evaporator coil. If after carrying out all the above checks, the unit does not appear to function correctly refer to the section, Trouble Shooting, or contact your supplier. WARNING: Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice. No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved. If the unit is switched off at the mains power supply for any reason, the unit must be allowed to stand at rest for at least three minutes before restarting. Failure to do so may cause the unit to blow the fuses owing to the compressor due to there being a refrigerant imbalance. Page 4 of 8

ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE ON ITEMS 1, 2, 3, AND 4. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air. Hold the nozzle of the air hose away from the coil (approx 6 ) to avoid damaging the fins. Alternatively, vacuum clean the coils. WARNING: DO NOT STEAM CLEAN REFRIGERATION COILS 2. Check that the fan is firmly secured to the motor shaft and that the fan rotates freely. The fan motor is sealed for life and therefore does not need oiling. 3. To check the refrigerant charge, run the unit for 15 minutes and briefly remove the cover. The evaporator coil should be evenly frost coated across its surface. At temperatures above 25 C, the coil may be covered with droplets of water rather than frost. Partial frosting accompanied by frosting of the thin capillary tubes, indicates loss of refrigerant gas or low charge. 4. Check all wiring connections. 5. To check the operation of the defrost system, switch the machine on and leave it running for approximately 45 minutes. The machine will then enter Hot Gas defrost mode for approximately 4 minutes before returning to normal operation. If the unit will not defrost, the printed circuit timer board may be defective or the by-pass valve may be inoperable. IF ANY OF THE PRECEDING PROBLEMS OCCUR, CONTACT THE EBAC SERVICE CENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO PREVENT PERMANENT DAMAGE. Page 5 of 8

REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a. The source of the leak must be determined and corrected. b. The machine should be thoroughly evacuated before recharging. c. The unit must be recharged with refrigerant measured accurately by weight. d. For evacuation and recharging of the machine, use the crimped and brazed charging stub attached to the side of the refrigerant compressor. The charging stub should be crimped and rebrazed after servicing. NEVER allow permanent service valves to be fitted to any part of the circuit. Service valves may leak causing further loss of refrigerant gas. 3. The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service. Compressor failure can result from the machine losing its refrigerant gas. The compressor can be replaced by a competent refrigeration technician. Failure of the compressor can be confirmed by the following procedure: a. Establish that power is present at the compressor terminals using a voltmeter. b. With the power disconnected, check the continuity of the internal winding by using meter across the compressor terminals. An open circuit indicates that the compressor should be replaced. c. Check that the compressor is not grounded by establishing that a circuit does not exist between the compressor terminals and the shell of the compressor. Page 6 of 8

TROUBLESHOOTING SYMPTOM CAUSE REMEDY Unit inoperative Little or no airflow Little or no water extraction Little or no defrost when required Unit vibrates excessively Water flooding inside the machine 1. No power to unit 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4. Loose electrical wiring 5. Fuse blown or circuit breaker tripped 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas 4. Blocked filter dryer 1. Faulty Timer 2. Faulty bypass timer 1. Loose compressor mounts 2. Damaged fan 1. Drain pipe blocked/frozen 2. Drain pipe too high 1. Check the power from the power supply panel. 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 5. Replace the fuse or reset the circuit breaker 1. Check all of the above 2. Contact the Factory 3. Contact the Factory 4. Contact the Factory 1. Contact the Factory 2. Contact the Factory 1. Tighten the nuts on the compressor mounts 2. Replace fan 1. Clear the obstruction 2. No section of the drainage hose should be above the level of the water outlet Spare parts available online www.eipldirect.com Page 7 of 8

CD30 SPARE PARTS LIST DESCRIPTION QTY PART NUMBER 1133500 Compressor 1 3022147 Condenser Coil 1 3020740 Evaporator Coil 1 1133501 Fan Motor 1 3035773 Fan Blade 1 3040129 Timer Board 1 1617990 Humidistat 1 3035145 Humidistat Knob 1 3030421 Solenoid Coil 1 3020421 Defrost By-Pass Valve 1 3020811 Filter Dryer 1 3020937 Cover Assembly 1 1013703 Control Panel Label 1 2013724 UK Head Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Tel: +44 (0) 1388 664400 Fax: +44 (0) 1388 662590 www.eipl.co.uk sales@eipl.co.uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Tel: +01 757 873 6800 Fax: +01 757 873 3632 www.ebacusa.com sales@ebacusa.com German Sales Office Ebac Industrial Products Ltd Miraustra 64 66 13509 Berlin Germany Tel: +49 3043 557241 Fax: +49 3043 557240 www.eip-ltd.de sales@eip-ltd.de Page 8 of 8 Product Support Questions: Contact Ebac USA at (757) 873 6800 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com