DESIGN & TECHNICAL MANUAL

Similar documents
DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

6. DUCT TYPE AR 60FUAK, AR 60UUAK

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Hi-spec Design model. Photo : LT series

CASSETTE TYPE AIR CONDITIONER

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

DESIGN & TECHNICAL MANUAL

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

The Intelligent Choice in Comfort

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

Air Conditioner CONTENTS

2 &3-4 Head Multi System

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

HEAT & COOL MODEL (REVERSE CYCLE)

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

JUNE & 3-4 Head Multi System

Hi-Wall Premier INVERTER ASTA09L ASTA12L ASTA18L ASTA24L ASTA30L. Hi-EER: (W/W) Hi-COP: (W/W) Hi-EER: 3.801(W/W) Hi-COP: 3.

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

OPERATING MANUAL UTY-RNNYM P/N English

Hi - Wall Split Systems 12K - 18K - 24K

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

FLOOR CONSOLE / UNDER CEILING DUAL type

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

EDUS Heat Pump - D-Series

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

MANUAL MODE D EMPLOI ASU9RL ASU12RL AOU9RL AOU12RL. English. Español Français CONSERVEZ CE MODE D'EMPLOI POUR RÉFÉRENCE ULTÉRIEUR

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

The New Generation of Heat Pumps

Digital Inverter 4 series 8 & 10HP

Compact Cassette Type

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Compact 4-way Cassette ( ) Type

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Transcription:

AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC

1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24

1. INDOOR UNIT CONTENTS 1. FEATURE... 01-01 2. WIRELESS REMOTE CONTROLLER... 01-03 3. SPECIFICATIONS... 01-05 4. DIMENSIONS... 01-06 5. WIRING DIAGRAMS... 01-07 6. CAPACITY TABLE... 01-08 6-1. COOLING CAPACITY... 01-08 6-2. HEATING CAPACITY... 01-09 7. FAN PERFORMANCE AND CAPACITY... 01-10 7-1. AIR VELOCITY DISTRIBUTION... 01-10 7-2. AIR FLOW...01-11 8. OPERATION NOISE... 01-12 8-1. NOISE LEVEL CURVE... 01-12 8-2. SOUND LEVEL CHECK POINT... 01-13 9. ELECTRIC CHARACTERISTICS... 01-14 10. SAFETY DEVICES... 01-15 11. OPTIONAL PARTS... 01-16 11-1. WIRED REMOTE CONTROLLER... 01-17 11-2. EXTERNAL CONNECT KIT... 01-19

- (01-01) - 111FEATURE MODEL AS A09LKC AS A12LKC FEATURES zenergy-efficiency classification A Europe Energy-Efficiency classification A achieved zall DC a b a b c DC fan motor i-pam control (12TYPE) When operation starts, the machine operates at high voltage and high power and when operation stabilizes, the set temperature is maintained at low voltage. V-PAM control (09TYPE) V-PAM technology makes a compressor more powerful. DC rotary compressor a c Front view

- (01-02) - zsuper quiet Air flow mode can be set in 4 steps and more detailed air flow setting is possible. Fan speed Quiet Noise level 21dB(A) zeasy maintenance Easy maintenance and always clean. Troublesome maintenance has been made easy. Since the front panel is easy to remove, maintenance is also easy. zinner drying operation This model is equipped with an inner drying function. After the power is turned off, the dry starts inside the air conditioner. This prevents the growth of mold and bacteria inside the air conditioner. During dew condensation Approx. 90 mins Drying zlow outdoor air temperature correspondence Corresponds to heating operation at -15 C outdoor air temperature Heating -15 to 24 C zcorresponds to maximum 20m long piping zair conditioner filter features(optional parts) Dirty Air Ion Deodorization Filter Apple-catechin Filter Clean Air Long-life Ion Deodorization Filter Applecatechin Filter

- (01-03) - 222WIRELESS REMOTE CONTROLLER FEATURES ¾Three kinds of timer setup (ON / OFF / SLEEP) are possible. ¾Easy operation. zbuilt-in timers Select from three different timer programs (On/Off/Sleep). zsleep timer The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping. Cooling operation/dry operation When the sleep timer is set, the set temperature automatically rises 1 C every hour. The set temperature can rise up to a maximum of 2 C. Heating operation When the sleep timer is set, the set temperature automatically drops 1 C every 30 minutes. The set temperature can drop to a maximum of 4 C. Timer setting 1 C 2 C 3 C 4 C 60min. 30min. 1 C 2 C 60min. 90min. Timer setting

- (01-04) - FUNCTIONS 1 1 Signal Transmitter 2 OPERATION MODE button 3 SET TEMP. button ( / ) 4 ECONOMY button 5 COIL DRY button 6 START/STOP button 2 3 4 5 6 7 8 9 10 11 12 15 14 13 7 TEST RUN button zthis button is used when installing the air conditioner, and should not be used under normal conditions, as it will cause the indoor unit s thermostat function to operate incorrectly. zif this button is pressed during normal operation, the indoor unit will switch to test operation mode, and the Indoor Unit s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously. zto stop the test operation mode, press the START/STOP button to stop the air conditioner. 8 SLEEP button 9 FAN CONTROL button 10 AIR FLOW DIRECTION SET button 11 SWING button 12 RESET button 13 TIMER OFF button 14 TIMER ON button 15 TIMER CANCEL button 16 Remote Controller Display 17 Transmit Indicator 18 Operation Mode Display Display panel 16 18 21 17 20 19 Timer Mode Display OFF TIMER Mark: ON TIMER Mark: SLEEP TIMER Mark: 20 Fan Speed Display 21 Temperature and time Display It displays the temperature setting. However, when making the Timer setting, it will display the Timer time. (The temperature setting will reappear after finishing the timer setting) 22 COIL DRY Display 23 SWING Display 22 19 23 SPECIFICATION SIZE (H x W x D mm) 139 56 18 WEIGHT ( g ) 85 ACCESSORY Holder

- (01-05) - 333SPECIFICATIONS Type WALL MOUNTED INVERTER HEAT PUMP Model name ASÜA09LKC ASÜA12LKC Power source Available voltage range European energy label Capacity Input power Current Cooling Heating Cooling Heating Cooling Heating Rated Min-Max Rated Min-Max Rated 230V~ 50Hz 198-264V~ 50Hz Cooling A A Heating A A kw 2.50 3.40 BTU/h 8,500 11,600 kw 0.5~3.0 0.9~3.8 BTU/h 1,700~10,200 3,100~13,000 kw 3.20 4.00 BTU/h 10,900 13,600 kw 0.5~3.9 0.9~5.6 BTU/h 1,700~13,300 3,100~19,100 0.78 1.06 Min-Max 0.25~1.02 0.25~1.40 kw Rated 0.885 1.105 Min-Max 0.25~1.15 0.25~1.99 Rated 4.2 4.9 Max 5.5 6.5 A Rated 4.8 5.2 Max 5.5 9.0 EER Cooling 3.21 3.21 kw/kw COP Heating 3.62 3.62 SENSIBLE CAPACITY Cooling kw 1.6 2.2 POWER FACTOR Cooling 81 94 % Heating 80 92 Moisture removal l/h (pints/h) 1.3 1.8 Fan Sound pressure level Heat exchanger type Enclosure Dimensions (H W D) Weight Connection pipe Operation range Remote controller type Drain pipe Air flow rate Type Q'ty Cooling Heating High Med 590 Low 430 Quiet 260 m 3 /h High 730 Med 590 Low 460 Quiet 290 710 Cross flow fan 1 Motor output W 30 Cooling Heating High Med 38 Low 33 Quiet 21 db(a) High 43 Med 38 Low 33 Quiet 21 Dimensions (H W D) mm 256 630 20 Fin pitch 1.1 Rows Stages 2 16 Pipe type Fin type Material Colour 43 Copper Aluminium Polystyrene WHITE Approximate colour of MUNSELL N 9.25/ Net 260 790 202 mm Gross 259 840 328 Net 7.5 (17) kg(lb) Gross 9.5 (21) Size Method Material Liquid Gas Cooling mm Φ6.35 (Φ1/4 in) Φ9.52 (Φ3/8 in) Flare C 18~32 %RH 80 or less Heating C 30 or less Wireless PP+LLDPE Size mm Outer diameter:21 / Outer diameter:13.6 Note : Specifications are based on the following conditions. Cooling:Indoor temperature of 27 C CDB/ 19 C CWB.and outdoor temperature of 35 C CDB/ 24 C CWB. Heating:Indoor temperature of 20 C CDB/ 15 C CWB.and outdoor temperature of 7 C CDB/ 6 C CWB. Pipe length : 5m,Height difference : 0m(Outdoor unit-indoor unit) The maximum current is the maximum value when the operated within the operation range(temperature).

- (01-06) - 444DIMENSIONS MODEL: AS A09LK, AS A12LK (Unit : mm) INSTALLATION PLACE 6 cm or more 5 cm or more Wall hook bracket 9 cm or more 150 cm or more 180 cm or more (Wall cap)

- (01-07) - 555WIRING DIAGRAMS MODEL: AS A09LK, AS A12LK TO

- (01-08) - 666CAPACITY TABLE 66666COOLING CAPACITY MODEL: AS A09LK AFR 11.8 Outdoor temperature Indoor temperature CDB 18 21 23 25 27 29 32 CWB 12 15 16 18 19 21 23 CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 20 2.34 1.60 0.55 2.61 1.61 0.56 2.70 1.75 0.56 2.87 1.76 0.56 2.96 1.90 0.57 3.14 1.89 0.57 3.32 2.01 0.58 25 2.22 1.52 0.62 2.48 1.53 0.62 2.56 1.66 0.63 2.73 1.67 0.63 2.81 1.80 0.64 2.98 1.79 0.64 3.15 1.91 0.65 30 2.10 1.44 0.68 2.34 1.44 0.69 2.42 1.57 0.70 2.58 1.58 0.70 2.66 1.70 0.71 2.82 1.70 0.72 2.98 1.81 0.72 35 1.98 1.35 0.75 2.20 1.36 0.76 2.28 1.48 0.77 2.43 1.48 0.78 2.50 1.60 0.78 2.65 1.59 0.79 2.80 1.70 0.80 40 1.76 1.20 0.75 1.96 1.21 0.76 2.03 1.32 0.77 2.16 1.32 0.78 2.23 1.43 0.78 2.36 1.42 0.79 2.50 1.51 0.80 43 1.63 1.12 0.75 1.82 1.12 0.76 1.88 1.22 0.77 2.00 1.22 0.77 2.07 1.32 0.78 2.19 1.32 0.78 2.31 1.40 0.79 MODEL: AS A12LK AFR 11.8 Outdoor temperature Indoor temperature CDB 18 21 23 25 27 29 32 CWB 12 15 16 18 19 21 23 CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 20 3.18 2.20 0.73 3.55 2.21 0.74 3.67 2.41 0.74 3.91 2.41 0.75 4.03 2.61 0.75 4.27 2.60 0.76 4.51 2.77 0.77 25 3.03 2.09 0.82 3.37 2.11 0.84 3.49 2.29 0.84 3.72 2.30 0.85 3.83 2.48 0.85 4.06 2.47 0.86 4.29 2.63 0.87 30 2.86 1.98 0.92 3.19 1.99 0.94 3.30 2.17 0.94 3.52 2.17 0.95 3.63 2.35 0.96 3.84 2.34 0.96 4.06 2.49 0.97 35 2.69 1.86 1.02 2.99 1.87 1.04 3.09 2.03 1.04 3.30 2.04 1.05 3.40 2.20 1.06 3.60 2.19 1.07 3.81 2.33 1.08 40 2.27 1.57 0.95 2.53 1.58 0.97 2.62 1.72 0.97 2.79 1.72 0.98 2.87 1.86 0.99 3.05 1.85 1.00 3.22 1.97 1.01 43 2.09 1.45 0.95 2.33 1.45 0.97 2.41 1.58 0.97 2.57 1.59 0.98 2.65 1.71 0.99 2.81 1.71 1.00 2.96 1.82 1.01 AFR : Air flow rate (m 3 /min) TC : Total capacity (kw) SHC : Sensible Heat capacity (kw) PI : Power Input (kw)

- (01-09) - 66666HEATING CAPACITY MODEL: AS A09LK AFR 12.2 Outdoor temperature Indoor temperature CDB 16 18 20 22 24 CDB CWB TC PI TC PI TC PI TC PI TC PI -15-16 2.05 0.95 2.00 0.97 1.96 0.99 1.91 1.01 1.86 1.03-10 -11 2.33 0.97 2.28 0.99 2.22 1.01 2.16 1.03 2.11 1.05-5 -7 2.67 1.00 2.61 1.02 2.54 1.04 2.48 1.07 2.42 1.09 0-2 3.17 1.04 3.10 1.06 3.02 1.08 2.95 1.10 2.87 1.13 5 3 3.70 1.08 3.61 1.11 3.52 1.13 3.43 1.15 3.29 1.15 7 6 4.01 1.10 3.92 1.13 3.82 1.15 3.65 1.15 3.47 1.15 10 8 4.23 1.12 4.13 1.14 3.96 1.15 3.79 1.15 3.63 1.15 15 10 4.38 1.15 4.17 1.15 4.00 1.15 3.80 1.15 3.65 1.15 MODEL: AS A12LK AFR 12.2 Outdoor temperature Indoor temperature CDB 16 18 20 22 24 CDB CWB TC PI TC PI TC PI TC PI TC PI -15-16 3.40 1.96 3.29 1.99 3.15 1.99 3.01 1.99 2.87 1.99-10 -11 3.76 1.96 3.65 1.99 3.49 1.99 3.34 1.99 3.19 1.99-5 -7 4.18 1.96 4.05 1.99 3.88 1.99 3.71 1.99 3.55 1.99 0-2 4.68 1.96 4.52 1.99 4.33 1.99 4.14 1.99 3.96 1.99 5 3 5.05 1.73 4.93 1.76 4.81 1.80 4.69 1.84 4.57 1.87 7 6 5.36 1.72 5.23 1.75 5.10 1.79 4.97 1.83 4.85 1.86 10 8 5.55 1.72 5.42 1.75 5.29 1.79 5.16 1.83 5.02 1.86 15 10 5.51 1.61 5.29 1.61 5.03 1.61 4.82 1.61 4.61 1.61 AFR : Air flow rate (m 3 /min) TC : Total capacity (kw) SHC: Sensible Heat capacity (kw) PI : Power Input (kw)

- (01-10) - 777FAN PERFORMANCE AND CAPACITY 77777AIR VELOCITY DISTRIBUTION MODEL: AS A09LK, AS A12LK 2 1 (m) Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Note: Fan speed:high Operation mode:fan Voltage:230V 0 2.0 1.0 0.5 1 2 0 1 2 3 4 5 6 7 8 (m) 3 (m) Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right & Left 2 1 0 1 2.0 1.0 1.0 0.5 0.5 2 3 0 1 2 3 4 5 6 7 8 (m) 3 (m) Unit : m/s SIDE VIEW Vertical flap : Up Horizontal flap : Center 2 2.0 1.0 0.5 1 0 0 1 2 3 4 5 6 7 8 (m) 3 (m) Unit : m/s SIDE VIEW Vertical flap : Down Horizontal flap : Center 2 1 2.0 1.0 0.5 0 0 1 2 3 4 5 6 7 8 (m)

- (01-11) - 77777AIR FLOW MODEL: AS A09LK, AS A12LK zcooling Fan speed Number of rotations (r.p.m) Air flow 710 m³/h HIGH 1400 197 l/s 418 CFM 590 m³/h MED 1200 164 l/s 347 CFM 430 m³/h LOW 920 119 l/s 253 CFM 260 m³/h QUIET 620 72 l/s 153 CFM HEATING z Fan speed Number of rotations (r.p.m) Air flow 730 m³/h HIGH 1440 203 l/s 430 CFM 590 m³/h MED 1200 164 l/s 347 CFM 460 m³/h LOW 980 128 l/s 271 CFM 290 m³/h QUIET 670 81 l/s 171 CFM

- (01-12) - 888OPERATION NOISE 88888NOISE LEVEL CURVE MODEL: AS A09LK zcooling zheating 80 80 70 70 Octave band sound pressure level, db:(0db=0.0002µbar) 60 50 40 30 20 Quiet High NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db:(0db=0.0002µbar) 60 50 40 30 20 Quiet High NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC-15 10 10 0 63 125 250 500 1,000 2,000 4,000 8,000 Octave band center frequency,hz 0 63 125 250 500 1,000 2,000 4,000 8,000 Octave band center frequency,hz MODEL: AS A12LK zcooling zheating 80 80 70 70 Octave band sound pressure level, db:(0db=0.0002µbar) 60 50 40 30 20 Quiet High NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 Octave band sound pressure level, db:(0db=0.0002µbar) 60 50 40 30 20 Quiet High NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 10 10 0 63 125 250 500 1,000 2,000 4,000 8,000 Octave band center frequency,hz 0 63 125 250 500 1,000 2,000 4,000 8,000 Octave band center frequency,hz

- (01-13) - 88888SOUND LEVEL CHECK POINT

- (01-14) - 999ELECTRIC CHARACTERISTICS Model Name ASÛA09LKC ASÛA12LKC Power Supply Voltage V 230 ~ Frequency Hz 50 Max Operating Current A 5.5 9.0 Circuit breaker A 15 *)Wiring Spec Connection Cable mm 2 1.5-2.5 Limited wiring length m 21 *) Wiring Spec Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005)

- (01-15) - 1111 SAFETY DEVICES Model Protection form ASÛA09LKC ASÛA12LKC Circuit protection Current fuse (PCB) 3.15A 250V Terminal protection Current (thermal) fuse 3A 250V 102 C Fan motor protection Terminal protection program MAX: 120±15 C

- (01-16) - 1111 OPTIONAL PARTS Exterior Parts name Model No. Summary Apple-catechin filter Ion deodorisation filter UTR-FA16 UTR-FA16-2 Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples. The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine-particle ceramic. Communication box kit UTY-XCBXE Use to connect with optional devices and air conditioner PC board. SU MO TU WE TH FR SA AM PM 3 6 9 12 15 18 21 Wired remote controller UTB- UD Unit control is performed by wired remote controller. External connect kit UTY-XWZX Use to connect with various peripheral devices and air conditioner PC board.

- (01-17) - 111111 FEATURES WIRED REMOTE CONTROLLER ¾Various timer setup (ON / OFF / WEEKLY) are possible. ¾Equipped with weekly timer as standard function. (2 times Start / Stop per day for a week) ¾When setting up a timer, operation mode and a temperature setup can be changed. ¾When a failure occurs,the error code is displayed. ¾Error indication. ¾Economy operation are possible. ¾Easy installation with a slim shape with no bulge in the back. zsimple function setting Setting of the air conditioner selection function is performed by remote controller. zhigh performance and compact size Three functions are combined in one unit. zbuilt-in timers Wired remote controller Weekly + + timer Setback timer Weekly timer Possible to set ON/OFF time to operate twice each day of the week. SU MO TU WE TH FR SA Easy-to-understand time bar display Setback timer Possible to set temperature for two time spans and for each day of the week. SU MO TU WE TH FR SA 7 7 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 3 6 9 12 15 18 21 Setup screen example (Set to Wednesday: 8:00 to 20:00.) 24 C 3 6 9 12 15 18 21 Screen after setup Setup screen example (Set from Sunday to Saturday: 12:00 to 15:00, 28 C.) 28 C 0 3 6 9 12 15 18 21 Time 0 3 6 9 12 15 18 21 Time At "Weekly timer" + "Set back timer" setup 24 C 28 C 24 C 28 C 24 C 0 3 6 9 12 15 18 21 Time zeasy-to-understand operation Timer area Operation area zsimple installation Components are compatible with standard switch boxes. Flat back construction allows equipment to be installed wherever it is needed. [Variable timer control] The operation/display sections are zoned according to time and operation, enabling variable programming to match application. European switch box JIS box

- (01-18) - FUNCTIONS 2 1 6 3 7 4 8 13 9 12 10 11 Display panel DIMENSION 16 19 20 18 120 17 21 15 5 14 [ Unit : mm ] 17 1 START/STOP button Pressed to start and stop operation. 2 Set temperature button Selects the setting temperature. 3 Master control button Selects the operating mode(auto, HEAT, FAN, COOL, DRY). 4 Fan control button Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH). 5 Economy button Turns the economy efficient mode on and off. 6 Timer mode (CLOCK ADJUST) button Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER). Set the current time. 7 Day (DAY OFF) button Temporarily cancels of one day timer. 8 Set back button Pressed to select the set back timer. 9 Set time button Pressed to set time. 10 Delete button The schedule of a weekly timer is deleted. 11 Set button Sets the date, hour, minute and on-off time. 12 Vertical airflow direction and swing button Push for two seconds to change the swing mode. 13 Horizontal airflow direction and swing button Push for two seconds to change the swing mode. 14 Filter button 15 Operation lamp Lights during operation and when the timer is on. 16 Timer and clock display 17 Operation mode display 18 Fan speed display 19 Operation lock display 20 Temperature display 21 Function display Defrost display Thermo sensor display 120 Economy display Vertical swing display Horizontal swing display Filter display Functions will be different due to type of indoor unit. For details, please see operation manual. SPECIFICATION SIZE (H x W x D mm) 120 x 120 x 17 WEIGHT ( g ) 160 CABLE LENGTH ( m ) 10 POWER ( V ) 12

- (01-19) - 111111 EXTERNAL CONNECT KIT This kit allows to operate the air conditioner, such as stopping and starting, using an external device, and output the operation status of the air conditioner. Only operation and stop signals will be output. Use the remote control to check the operation mode, temperature, and airflow. Check the error information on the display area of the main unit. Operation mode, temperature, and airflow cannot be set by external input. Use the remote controller to set. If the air-conditioner is activated by external input, it will operate in the settings before stop. To change the settings, use the remote controller. 11111111 CONTROL INPUT SETTING You can control air conditioner ON / OFF operation by external input. zsignal specification No voltage ON/OFF continuous signal. Contact capacity : DC12V 10mA External input signal ON OFF Remote controller signal ON OFF ON OFF Indoor unit status OPERATION STOP zinstallation example For remote operation Indoor unit Print circuit board External input 1 3 Orange Yellow External device ( Field supply ) External output For external timer operation Indoor unit Print circuit board External input 1 3 Orange Yellow External device ( Field supply ) External output

- (01-20) - 11111111 Operating output setting You can display air conditioner ON / OFF operation by e xternal o utput. zsignal specification No voltage contact. Contact capacity : Max. DC24V 10mA to 1A or less Indoor unit status OPERATION STOP External output signal SHORT OPEN zinstallation example For operation display Indoor unit Print circuit board External input External output 1 2 Blue Purple External device ( Field supply ) Ic Vc

2. SINGLE TYPE : AO R09LKC AO R12LKC DTR_AO058E_01 2010.02.24

CONTENTS 2. 1. SPECIFICATIONS... 02-01 2. DIMENSIONS... 02-02 3. REFRIGERANT CIRCUIT... 02-03 4. WIRING DIAGRAMS... 02-04 5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH.AND HEIGHT DIFERENCE... 02-06 6. ADDITIONAL CHARGE CALCULATION... 02-08 7. AIR FLOW... 02-09 8. OPERATION NOISE... 02-10 8-1. NOISE LEVEL CURVE... 02-10 8-2. SOUND LEVEL CHECK POINT...02-11 9. ELECTRIC CHARACTERISTICS... 02-12 10. SAFETY DEVICES... 02-13

- (02-01) - 111SPECIFICATIONS Type INVERTER COOLING & HEATING Model name AOÛR09LKC AOÛR12LKC Power source Available voltage range 230V~ 50Hz 198-264V~ 50Hz Starting current A 4.8 5.2 Fan Sound pressure level Heat exchanger type Compressor Refrigerant Air flow rate Type Q'ty Cooling 1,720 1,830 m 3 /h Heating 1,510 1,600 Propeller fan 1 Motor output W 40 Type Q'ty Cooling 45 50 db(a) Heating 45 50 Dimensions (H W D) 650 504 18.2 642 504 36.4 mm Fin pitch 1.3 1.4 Rows x Stages 1 24 2 24 Pipe type Fin type Copper Aluminium Rotary 1 Motor output W 500 750 Type R410A Charge g 650 800 Refrigerant oil Type POE(VG74) Enclosure Dimensions ( H W D) Weight Connection pipe Operation range Material Colour Steel BEIGE Approximate colour of MUNSELL 10YR 7.5/1.0 Net 540 660 290 540 660 290 mm Gross 611 797 401 611 797 401 Net 22(48) 29(64) kg(lb.) Gross 25(55) 32(71) Size Method Liquid Gas mm Φ6.35 (Φ 1/4 in.) Φ9.52 (Φ 3/8 in.) Max. length 20 (chargeless:15) m Max. height difference 15 Flare Cooling 18 to 43 C Heating -15 to 24 Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB.and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / 15 CWB.and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 5 m, Height difference : 0 m.(outdoor unit - Indoor unit) The maximum current is the maximum value when the operated within the operation range(temperature).

- (02-02) - 222DIMENSIONS MODEL: AO R09LK, AO R12LK (Unit : mm) 38 330 φ20 19.5 660 INSTALLATION PLACE 600 mm or more 20 540 353 320 454 103 68 290 100 mm or more 100 mm or more 250 mm or more (Service space) 200 mm or more If the space is larger that is stated, the condition will be the same as that are no obstacles.

- (02-03) - 333REFRIGERANT CIRCUIT MODEL: AO R09LK, AO R12LK 3-Way valve Muffler Heat exchanger ( INDOOR ) 2-Way valve Compressor 4-Way valve Strainer Expansion valve Heat exchanger ( OUTDOOR ) Strainer Cooling Heating Refrigerant pipe diameter Liquid : 1/4" (6.35 mm) Gas : 3/8" (9.52 mm)

- (02-04) - 444WIRING DIAGRAMS MODEL: AO R09LK

- (02-05) - MODEL: AO R12LK

- (02-06) - CAPACITY COMPENSATION RATE FOR PIPE LENGTH 555 AND HEIGHT DIFERENCE MODEL: AO R09LK COOLING Û1 Indoor unit is upper than outdoor unit. Pipe length (m) 5 7.5 10 15 20 15 - - - 0.872 0.910 10 - - 0.961 0.886 0.925 7.5-0.979 0.965 0.890 0.929 Height difference H (m) 5 0.992 0.983 0.969 0.893 0.933 0 1.000 0.991 0.976 0.901 0.940-5 1.000 0.991 0.976 0.901 0.940 Û2 Indoor unit is under than outdoor unit -7.5-0.991 0.976 0.901 0.940-10 - - 0.976 0.901 0.940-15 - - - 0.901 0.940 HEATING Pipe length (m) 5 7.5 10 15 20 15 - - - 0.832 0.822 Û1 Indoor unit is upper than outdoor unit. 10 - - 0.917 0.832 0.822 7.5-0.961 0.917 0.832 0.822 Height difference H (m) 5 1.000 0.961 0.917 0.832 0.822 0 1.000 0.961 0.917 0.832 0.822-5 0.995 0.956 0.912 0.828 0.818 Û2 Indoor unit is under than outdoor unit -7.5-0.954 0.910 0.826 0.816-10 - - 0.908 0.824 0.814-15 - - - 0.815 0.805 Height difference H Indoor unit Outdoor unit Outdoor unit Indoor unit Connection pipe 1 Indoor unit is upper than outdoor unit. Connection pipe 2 Indoor unit is under than outdoor unit.

- (02-07) - MODEL: AO R12LK COOLING Û1 Indoor unit is upper than outdoor unit. Pipe length (m) 5 7.5 10 15 20 15 - - - 0.858 0.868 10 - - 0.929 0.872 0.882 7.5-0.960 0.933 0.876 0.885 Height difference H (m) 5 0.992 0.964 0.937 0.879 0.889 0 1.000 0.972 0.944 0.887 0.896-5 1.000 0.972 0.944 0.887 0.896 Û2 Indoor unit is under than outdoor unit -7.5-0.972 0.944 0.887 0.896-10 - - 0.944 0.887 0.896-15 - - - 0.887 0.896 HEATING Pipe length (m) 5 7.5 10 15 20 15 - - - 0.896 0.879 Û1 Indoor unit is upper than outdoor unit. 10 - - 0.968 0.896 0.879 7.5-0.994 0.968 0.896 0.879 Height difference H (m) 5 1.000 0.994 0.968 0.896 0.879 0 1.000 0.994 0.968 0.896 0.879-5 0.995 0.989 0.963 0.891 0.875 Û2 Indoor unit is under than outdoor unit -7.5-0.987 0.961 0.889 0.873-10 - - 0.959 0.887 0.871-15 - - - 0.878 0.862 Height difference H Indoor unit Outdoor unit Outdoor unit Indoor unit Connection pipe 1 Indoor unit is upper than outdoor unit. Connection pipe 2 Indoor unit is under than outdoor unit.

- (02-08) - 666ADDITIONAL CHARGE CALCULATION MODEL: AO R09LK Refrigerant type R410A Refrigerant amount g 650 zrefrigerant CHARGE Pipe length m ~15 20 Additional charge g 0 (Charge less) +100 20g/m MODEL: AO R12LK Refrigerant type R410A Refrigerant amount g 800 zrefrigerant CHARGE Pipe length m ~15 20 Additional charge g 0 (Charge less) +100 20g/m

- (02-09) - 777AIR FLOW MODEL: AO R09LK zcooling Number of rotations (r.p.m) 730 Air flow 1720 m 3 /h 478 l/s 1012 CFM zheating Number of rotations (r.p.m) Air flow 1510 m 3 /h 650 419 l/s 889 CFM MODEL: AO R12LK zcooling Number of rotations (r.p.m) Air flow 1830 m 3 /h 860 508 l/s 1077 CFM zheating Number of rotations (r.p.m) Air flow 1600 m 3 /h 760 444 l/s 942 CFM

- (02-10) - 888OPERATION NOISE 88888NOISE LEVEL CURVE MODEL: AO R09LK zcooling 80 70 zheating 80 70 Octave band sound pressure level, db:(0db=0.0002µbar) 60 50 40 30 20 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db:(0db=0.0002µbar) 60 50 40 30 20 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC-15 10 10 0 63 125 250 500 1,000 2,000 4,000 8,000 Octave band center frequency,hz 0 63 125 250 500 1,000 2,000 4,000 8,000 Octave band center frequency,hz MODEL: AO R12LK zcooling 80 zheating 80 70 70 Octave band sound pressure level, db:(0db=0.0002µbar) 60 50 40 30 20 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db:(0db=0.0002µbar) 60 50 40 30 20 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC-15 10 10 0 63 125 250 500 1,000 2,000 4,000 8,000 Octave band center frequency,hz 0 63 125 250 500 1,000 2,000 4,000 8,000 Octave band center frequency,hz

- (02-11) - 88888SOUND LEVEL CHECK POINT

- (02-12) - 999ELECTRIC CHARACTERISTICS Model Name AOÛR09LKC AOÛR12LKC Power Supply Voltage V 230 ~ Frequency Hz 50 Starting Current A 4.8 5.2 *) Wiring Spec Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005)

- (02-13) - 1111 SAFETY DEVICES Protection form AOÛR09LKC Model AOÛR12LKC Circuit protection Current fuse (Near the terminal) Current fuse (MAIN PRINTED CIRCUIT BOARD) 20A 250V 3.15A 250V Fan motor protection Terminal protection program OFF:100 +15-10 C ON:95 +15-10 C Compressor protection Terminal protection program (DISCHARGE TEMP) OFF:110 C ON: After 7 minutes