BOILER FOR HOT WATER AND STEAM

Similar documents
BOILER FOR HOT WATER AND STEAM

Rapid. Suspended Warm Air Heater. Caring for the environment!

CYLINDER PLASTICS CERAMIC BAND HEATERS. Main technical characteristics: Mechanics. Electrics

SAGV x 1/1 GN 7-12 x 20 COMBI STEAMER FOR GASTRONOMY

IMMERSION HEATERS GAS AND BSP

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

SAEV x 1/1 GN x 20 COMBI STEAMER FOR GASTRONOMY

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Plate Coil Heat Exchangers

PCH Heating Condensing Module for Air Handling and Roof Top Units

Pro6 Duo. Stampa Novaprint - Tel cod USER MANUAL

NAEB x 2/1 GN - 40 x 1/1 GN x 26 / x 20 DEVICE FOR GASTRONOMY

Steam sterilizer AHS-75-DRY

ELECTRIC HEATING ELEMENTS

Forced draught gas burner

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

PCH/new Series. High performance, total flexibility

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers

Forced draught gas burner

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

VS LD series vertical steam sterilizers

TECH WASH. ranges. TECH Main Features

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

ROTAMAT THE ROTAMAT. The ideal solution for coating of mass-produced small parts WE IMPROVE SURFACES

NAGV x 2/1 GN - 20 x 1/1 GN x 26 / x 20 DEVICE FOR GASTRONOMY

Pro-Clean Stratified Tank scope of delivery:

4L Instant Water Boiler Instructions for Use

Ciao Green Condensing Wall-Hung Boilers

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

P R O F E S S I O N A L C O O K I N G

MATRIX 2 - COD REV.02

Explosion-proof Immersion Heater Type D-8660

MATRIX 2 - COD REV.00

Floor standing boilers. RMG Mk.II RS Mk.II

THERMODYNAMIC STEAM TRAP

CM24T, CM24P Coffee Systems

HEATERS MOUNTED ON THREADED PLUG

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

MANUFACTURER OF HEATING ELEMENTS

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK

Prextherm Rsw High efficiency steel pressurised boilers

C Note! LGI16... Burner Controls. Building Technologies

Ultrasonic From delicate microsurgery instruments to heavy duty sets

ACCUMULATION OF EUROPEAN CLASS

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN. Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

Residential Heating Boilers

Dissolved Oxygen Sensors

D O M E S T I C Solar Thermal

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

Are Thermistors the Right Choice for Your Temperature Measurement Application?

HOLDING CABINETS CP MULTI CP ONE NICE

ROTARY SPRAY HEADS CATALOGUE

requirements can be equipped with an additional product temperature control probe, and with a printer.

Easyfire Standalone biomass pellet boiler

GALATEA DOMUS. Dal 1901 COD

Rotary screw compressors. kw 2, ,5 bar 10 BRIO

PROFESSIONAL REFRIGERATION

Electrolux Professional Customer Care. Accessories & Consumables Catalogue Cook&Chill

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

HEATING ELEMENTS FOR WATER HEATING output 500W W water and similar liquid heating

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

UNICA AND UNMISTAKABLE.

BF2 GLASSLINED CYLINDERS WITH TWO REMOVABLE STAINLESS STEEL HEAT EXCHANGERS ( LITRES)

STATIONARY HEATERS 2011/

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

Grinding mill MISTRAL 50L (art. 650P)

Cooking specialists since 1972

kw COOLING kw HEATING

ConCept // be flexible

Installation & Maintenance Manual

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

B2009 compact. Dal 1901 COD

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Advantages / Characteristics

Packing. Euronda Spa t (+39) m euronda.com

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

B2009 compact. Dal 1901 COD

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

SYRINGES PROCESSING OF PRE-STERILIZED SYRINGES

October Solar Thermal

Model Smart Digital Humidistat

Glem Experience. IO CUCINO con Glem. I cook with Glem

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Washer disinfectors. > CSSD Range - Systems and Automations. devoted to hygiene. For the Environmentally conscious

TECH WASH. ranges. TECH Main Features. FRONT-OPENING DISHWASHERS 500 x 500 mm basket

RS /E-EV C01 SERIES

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

RIELLO 40 GS/M SERIES

CONTROLS FOR ELECTRIC RADIATORS AND TOWEL RAILS

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Transcription:

BOILER FOR HOT WATER AND STEAM

ZIHET Boiler Catalogue Boilers are stainless-steel tanks equipped with heating elements for water heating. Depending on the operating temperature, boilers can produce hot water or steam. In some applications, both hot water and steam. A common application is in the production of hot water and steam on coffee machines, either for household and professional purpose, but for other applications range from steam ironing to spa equipment, from sterilizers to tumble dryers, from dishwasher to washing machines. ZIHET boilers are high performance products offering outstanding power rates in small spaces. Reliability and food compliance are keystones of the products, along with a wide array of customization options. Technical facts of standard boilers Voltage 230 V Power by capacity 0,5 lt 0,7 lt 0,9 lt Power Diameter 600 3000W depending on displacement Ø 76,1 mm Overall Height 147 mm 203 mm 242 mm Surface load < 10 W/cm 2 Fixing Electrical connections Material Compliance Food compliance 2xM4 threaded bush Faston AISI 316L/1.4404 (body) Alloy 800/1.4876 (heating element) 2014/35/UE (LVD) 2014/68/UE (PED) art.4.3 UE 10/2011 (Moca) Production Water Steam Design pressure 12,5 bar 12,5 bar Operating pressure 12 bar 3 bar Operating temperature 5 98 C 5 130 C Cut-off temperature 115 C 145 C 00-03 - 1118

BOILER FOR HOT WATER AND STEAM Water outlet Reliability Heater elements of the boiler are extremely reliable, having successfully exceeded over 300.000 on/off cycles. Mechanical reliability is also synonym of long lifetime: welds are guaranteed for 500.000 high pressure cycles. Water level probe Perimetral fitting Perimetral fitting Upper lid NTC sensor Perimetral fitting M4 threaded bush Options Depending on the final application of the boiler, the product family ranges in a selection of different capacities and electrical power. Combination of size and power are studied to fill any potential need. Safety thermostat Heater element M4 threaded bush Lower lid Water inlet Upper lid: perimetral fittings The water/steam outlet is a standard G1/4 F threaded fitting in the center of the upper lid. Peripherally to the upper lid a series of three fittings are weld in order to allow the boiler to be equipped, on request, with optional. Perimetral threaded fittings, G1/8 F, can either be standard or special for suitable for water level probe. The configurators allows the maximum flexibility for the selection of fittings types. Should the configuration contain one of more fittings for water level probe, the probe itself can be selected in the following steps. G 1/8 F perimetral fitting G 1/8 F perimetral fitting for water level probe Lower lid: perimetral fittings The inlet of water can also be customized up on the need. In particular, beside a standard G1/8 F threaded fitting, a G1/8 F with water spreader is available. The water spreader prevents the cold water from being injected directly toward the heating element, therefore avoiding sudden gas formation. G 1/8 F lower fitting G 1/8 F lower fitting with water spreader 00-04 - 1118

Water level probes The water level probe is the electrical device that opens and closes in response to liquid level sensed inside the boiler. During normal operating condition, the probe is screwed up on the upper lid with the tip positioned precisely at the level that will start the refilling of the boiler or/and at the level that protects the heater element from running dry. The user can option up to two probes, for single-probe or multi-probe applications. While the first provides information as water level is low, the second can be used to stop the refill. Probes are provided of the same length (147mm), bundled in a separated plastic bag. The user will decide which one to use as refill-stop probe by cutting the excess of the chosen one. Herewith suggested lengths for each boiler capacity: Water level probe NTC sensor NTC sensors is a resistor with negative temperature coefficient, specifically encapsulated to comply with working conditions of the boiler. It also provides excellent long-term stability and short response time in high-temperature applications such in the coffee machines. NTC sensor Insulation A proper insulation is essential to save energy, as it works as a barrier to heat losses. The ignition of the heater element results from a temperature drop that can be thwarted by an effective insulating wrapping. Melamine is a material commonly used as insulation for pipes and ductwork as well as the core of the insulating wrapping of the boiler. Foamed melamine is ennobled by a TNT outer layer that allows to wear the coat around the boiler body by mean of a Velcro strip. As for flame resistance, the TNT insulation is compliant with DIN 4102 UNI9177 B1 - Class 1. Melamine + TNT Insulating coat Dummy plug Boiler fittings are not capped by default. Should the user prefer to cap fittings, a set of plugs are available as optional. Standard plugs are G1/4 and G1/8, in a set of combination that can match any possible choice. Caps are bundled in a separated plastic bag. Dummy plug set Safety thermostat (manual reset) It is the device that senses the temperature of the boiler body and opens the circuit, automatically disconnecting power, when the working temperature exceeds the designed set point. The cut-off thermostat is therefore a safety device available as option, with proper set point temperatures that comply with the production of hot water of steam. Optional thermostat includes the cables connection to the power terminals of the boiler. Both phases of the heater are protected by the thermostat. Manual reset cut-off thermostat 00-05 - 1118

BOILER FOR HOT WATER AND STEAM Configuration Each configured Boiler has a unique 20 characters code that embeds all selected options. Note that in order to allow the configuration to be quoted the 21st character is necessary. Example code: The code refers to a Boiler for 230V 50Hz supply, 0,7 liters of capacity, with standard fittings on both the upper lid and fitting with water spreader on the lower lid, NTC sensor, melamine insulation, 1/8 dummy plug and a 115 C cut off thermostat, whose quote is required for a 50pcs delivery batch. List of possible configuration Below a list of possible configured boilers with default options. For further configurations, such as boilers with double water level probe, dummy plugs or with different perimetral fittings combination, please refer to BoPlam configurator. 00-06 - 1118

Via Podgora, 26-31029 Vittorio Veneto (TV) - Italy Tel. +39 0438 9101 - Fax +39 0438 912272-912236 www.zoppasindustries.com cod. 690190425-1118