U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Similar documents
Design & Fabrication of Hybrid Cooler

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

η second law = Second law efficiency

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Pressure Enthalpy Charts

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Enhancement of COP in Vapour Compression Refrigeration System

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

International Journal of Informative & Futuristic Research ISSN (Online):

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

HVAC Fundamentals & Refrigeration Cycle

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Transcritical CO2 Bottle Cooler Development

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

A Review of Different Types of Combine Cooling System

Design of LPG Refrigeration System

Performance Enhancement of Mini Refrigerator with Phase Change Materials

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

ENHANCEMENT OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOFLUIDS

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

CHAPTER 1 INTRODUCTION

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

A Comparison Between Refrigerants Used In Air Conditioning

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

II. OBJECTIVE OF RESEARCH

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

CHAPTER 1 INTRODUCTION

(Refer Slide Time: 00:00:40 min)

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

ISSN Vol.08,Issue.21, November-2016, Pages:

Performance Assessment of Water Cooled Condenser Refrigeration System

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

DEEPAK PALIWAL, S.P.S.RAJPUT

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Sarthak Thakar, 2 R.P.Prajapati 1

Waghmare Tushar Ramrao, D.S.Nakate

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Department of MCE, Islamic University of Technology 2. Abstract

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Study of solar-thermal collector assisted hybrid split air conditioner

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Transcription:

DESIGN OF HYBRID AIR COOLER USING VAPOUR COMPRESSION REFRIGERATION SYSTEM Vimalkirti Shende 1, Sushil Borkar 2, Touseef Iqbal Qureshi 3 Asst. Prof. Nikhil Bhende 1 1,2,3 U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India 1 Associate Professor, Department Mechanical of Engineering, J D Engineering College, Nagpur, Maharashtra, India Email vimalkirti2012@gmail.com Abstract: Now a days, global warming is one of the serious concern for environment to get protected from it every one is taking help of technology by the means of different types of refrigeration system for comfort food process, medicines, blood storage, humidity control, etc. use of refrigeration system is not only ineffective environment but also give total comfort. In India middle class and poor families cannot afford all types of Refrigeration system like an AC, Refrigerator, etc. Generally they purchase only Air cooler. To solve this we can integrate Refrigeration system of AC, refrigerator and Air cooler in one product. In this type of system consist of various components such as compressor, condenser, capillary tube, evaporator, motor, fan, etc. Our project is to use technology of vapour compression refrigeration system. Key words: compressor, condenser, evaporator, expansion valve, electric fan. 1. INTRODUCTION: Refrigeration is the process of maintaining low temperature in comparison to surrounding temperature. Refrigeration is the process of removing heat from an enclosed space or from a substance and rejecting it elsewhere for the primary purpose of lowering the temperature of the enclose space or substance and then maintaining that lower temperature.basic concept of the project is to design an appliance that can work like AC as well as fan but will not consume that much amount of electricity, cost, size and water. In this method of cooling system we are going to use copper pipes, fan, compressor, cooling gas, compact body, condenser, Evaporator, etc.cooling systems or air conditioning systems are going to be in detail description in the following report; these systems also have huge impacts on the surrounding environment. New method of cooling with concept of AC could solve the problems generated by the existing air-conditioning installations. It not only reduces the power consumption but also increases cooling effects and having less cost than air-conditioning system. It works in the absence of water and having less maintenance as compare to domestic cooler. And its cost is cheaper than the AC, so it will beneficial for middle class people. 2. WORKING CONCEPT: The vapor-compression uses a circulating liquid refrigerant (R134a is also known as Tetrafluoroethane) as the medium which absorbs and removes heat from the space to be cooled and subsequently rejects that heat elsewhere. All such systems have four components: a compressor, a condenser, a thermal expansion valve (also called a throttle valve or metering device) and an Evaporator. That hot vapor is routed through a condenser where it is cooled and condensed into a liquid by flowing through a coil or tubes with cool water or cool air flowing across the coil or tubes. This is where the circulating refrigerant rejects heat from the system and the rejected heat is carried away. 3. DESIGN OF HYBRID COOLER: Available online on WWW.IJIRMF.COM Page 77

4. COMPONENTS: COMPRESSOR:- The primary advantage of a hermetic and semi-hermetic is that there is no route for the gas to leak out of the system and less maintenance and it is widely used in household refrigerator. Compressor compresses the refrigerant. We are use hermetically sealed compressor. In hermetically sealed compressor, the compressor and motor are welded in steel casing and the two are connected by a common shaft. This makes whole compressor and the motor a single compact and portable unit that can be handled easily. The hermetically sealed compressor is very different from the traditional open type of compressor. Compressor selection:- Compressor = 96 watt, btu-365, 92Kcal/hr Capacity 1 TR, 50 Hz, 1PH Condenser temp. range =-23.3 c to 54.4 c Temp. Range = -5 c to 15 c Specification:- Inlet pipe 6 mm, 220/50Hz, 1 PH, thermally protected, capacity 1 TR. Fig1:-Compressor CONDENSER: - The initial part of the cooling process de-superheats the gas before it is then turned back into liquid. The condenser is a heat exchanger that rejects all the heat from the refrigeration system. This includes not only the heat absorbed by the evaporator but also the heat energy to the compressor. The condenser accept hot, high pressure refrigerant, usually superheated gas from the compressor and reject heat from the gas to some cooler substance, usually air and water. Specification: - Height 240 mm, Length 255 mm, No coil present in condenser with IP/OP is 8, condenser pipe 10 mm, width 40 mm Fig 2:- Condenser EXPANSION VALVE: The capillary tube substituted for the convectional liquid line from the condenser and soldered to the suction line to form a single heat exchanger. The function of expansion valve to allow the low temperature and high pressure liquid enters with the restricted area, and they can be leave from the expansion valve with low pressure and temperature in form of mixture of vapour and liquid, and then keep the evaporator active. Expansion process one of the main factors responsible for energy loss in VCR cycle. Specification: - Length of capillary tube 1300 mm. No of turns 11, Diameter is 2mm. Available online on WWW.IJIRMF.COM Page 78

Fig3:- Expansion Valve EVAPORATOR: - During this process it changes its state from a liquid to a gas. For the purpose of compression, evaporator part also suggested. The evaporator has number of circular tube inside it as shown in figure bellow, and is manufactured to yield same pressure drop as the original one. The number and diameter of the tubes are selected iteratively to obtain the same design requirements, such as, heat load, pressure drop, at the inlet and exit condition. Fig4:- Evaporator FAN:-An apparatus rotating blades that create a current of air for cooling or ventilation. Specification:- Blade diameter is 234 mm, Angle is 23 0. Fig 5:- Fan MOTOR: 1. Electric motor is used to convert electrical energy into mechanical energy. 2. In particular, the squirrel-cage design is the most widely used electric motor in industrial Applications. 3. Electric motors are used to produce linear and rotary forces (torque). 4. This motor runs at 1500 rpm & 1.5 HP. 5. We used copper winding motor. Fig6:- Motor Available online on WWW.IJIRMF.COM Page 79

REFRIGERANT:- 1. In this project we are use a refrigerant is R-134a. It is also known as tetrafluroethane (CH3CH2F) from the family of HFC refrigerant. 2. Currently it is also being widely used in the air conditioning system in newer automotive vehicles. It exists in gas form when 3. Expose to the environment as the boiling temperature is -14.9 F or -26.1 C. 4. The CFCs and HCFCs refrigerants produce more defects to ozone layer. 5. Hence we are used to R134a and concluded that energetic defect occurred in compressor was highest as compare to the other refrigerant through their analysis it has been found that instead of 145g of R134a if 60g of R600a is use in consider system gave same performance which ultimately result in economical advantages. V. Analysis of standard vapour compression refrigeration system:- Fig 7:- Standard vapour compression refrigeration cycle on p-h chart Evaporator: Heat transfer rate at evaporator or refrigeration capacity Q e =m(h 1 -h 4 ) The evaporator pressure P=P sat (T e ) Where, m-mass flow rate in kg/s h 1, h 4 are specific enthalpies kj/kg P sat - saturation temperature Te-evaporator temperature Compressor : Power input to the compressor W c =m(h 2 -h 1 ) h 1, h 2 -specific enthalpies Condenser : Heat transfer rate of condenser Q c =m(h 2 -h 3 ) h 1, h 2 -specific enthalpies Expansion device: h 3 =h4 The COP of the system is given by COP= (Q e /W e ) = (m (h 1 -h 4 )/m (h 2 -h 1 )) = (h1-h4)/ (h 2 -h 1 ) At any point in the cycle, the mass floe rate of refrigerant m can be written in terms of volumetric flow rate and specific volume at that point i.e., M=V/v Applying this equation to the inlet condition of the compressor M=V 1 /v Where, V 1 -volumetric flow rate at compressor inlet, v 1 -indication of the size if the compressor. The refrigeration capacity in terms of volumetric flow rate Q e =m (h 1 -h4) =V 1 ((h 1 -h 4 )/v 1 ) (h 1 -h 4 )/v 1 -volumetric effect (kj/m 3 ) Available online on WWW.IJIRMF.COM Page 80

5. CONCLUSION: R134a refrigerant is non-toxic and does not flare up within the whole range of operational temperatures. This project is very cheap and effective as compared with the conventional cooler and air conditioner system as it based on VCRs system. It has very low power consumption which ultimately increases the COP of the system which increases the cooling effect (refrigeration effect) of the system. It has very low effect on environment as it saves electricity and water. The concept is very cost effective as compared to AC and Very Energy Effective system. 6. LITERATURE REVIEW: Taliv Hussain, Arjun Sharma, Effect Of Sub-cooling in VCRS Cycle and Compared to simple VCRS System, ELK Asia Pacific Journal,Punjab 978-81-930411-4-7. According to this paper, Decreasing the consumption of power in a vapors compression air conditioning system with increase in refrigeration effect and reduction of compressor work is a major concern and challenging problem especially in the area where extreme weather conditions of about 50 C exists.experimental results show that the use of sub-cooling by heat exchanger will improve the COP. G Venkatarathnam, S Srinivasa Murthy, Refrigerants for Vapour Compression Refrigeration Systems, General Article on Feb 2012. In this article, various issues related to this changeover of refrigerants being used in vapor compression refrigeration systems are discussed. This paper Discuss the mandate of Montreal Protocol banning ozone depleting substances, and Kyoto Protocol later on curtailing the use of substances which contribute to global warming, conventional refrigerants are to be replaced by environment friendly working fluids. R. T. Saudagar, U. S. Wankhede, Experimental Analysis of Vapor Compression Refrigeration System with Diffuser at Condenser Inlet, International Journal of Engineering and Advanced Technology (IJEAT) on April 2013. This concept reduces size of condenser to achieve the same system efficiency. This paper discusses design and testing of diffuser at condenser inlet in vapors compression refrigeration system. K. Nagalakshmi, G. Marurhiprasad Yadav, The Design and Performance Analysis of Refrigeration System Using R12 & R134a Refrigerants, Int. Journal of Engineering Research and Applications Feb on 2014. In this report, the design and performance analysis of refrigeration system using R12 & R134a refrigerants are presented. The design calculations of the suitable and necessary refrigerator equipment and their results are also reported here. REFERENCES: 1. Taliv Hussain, Arjun Sharma, Effect of Sub-cooling in VCRS Cycle and Compared to simple VCRS System, ELK Asia Pacific Journal Punjab 978-81-930411-4-7. 2. G Venkatarathnam, S Srinivasa Murthy, Refrigerants for Vapor Compression Refrigeration Systems, General Article Feb 2012. 3. R. T. Saudagar, U. S. Wankhede, Experimental Analysis of Vapor Compression Refrigeration System with Diffuser at Condenser Inlet, International Journal of Engineering and Advanced Technology (IJEAT) April 2013. 4. K. Nagalakshmi, G. Marurhiprasad Yadav, The Design and Performance Analysis of Refrigeration System Using R12 & R134a Refrigerants, Int. Journal of Engineering Research and Applications Feb on 2014. 5. Shireesha Mary Ch, Nandini Ch, Divya Samala, Siva Kumar B, Parthasarathy Garrr, A review: Increase in Performance of vapor compression refrigeration system using fan, International Journal of Engineering and Applied Sciences. Available online on WWW.IJIRMF.COM Page 81