Similar documents
PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS FOR SUGAR CANE HARVESTERS

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

THE WORLD LEADER. in special hazard fire suppression solutions

Ceodeux-Fire Extinguishers Valves Technology S.A.

Fire Protection for Manufacturing Facilities

Don t Compromise on Fire Safety Choose Certified Quality Products

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

SUPPRESSION SALES I INSTALLATION I SERVICE

FIRE SUPPRESSION SYSTEM

AUTOMATIC FIRE SUPPRESSION SYSTEMS

BOC FS125 The Fire Extinguishing Solution

Fire Protection for Servers and Telecoms

PROTECCIÓN DE RIESGOS ESPECIALES AUTOMATIC FIREFIGHTING SYSTEMS IN VEHICLES. con tubo de detección

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

Superior by Design The Kidde ADS TM FM-200 System

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

SECURITY BLANKET Foam Fire Protection Products

SAFETY THE BEST FOR YOUR EQUIPMENT

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

SECTION FM-200 FIRE SUPPRESSION SYSTEM

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

Fire Protection for Buses Micro environment protection

automatic FiReFighTing SYSTeMS in PainT booths

WSU-TFREC Fire Safety Training

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

CHAPTER THREE SPRINKLER SYSTEM AND FM-200 AGENT SYSTEM

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

Protecting Backup Generators and UPS Systems Against Risk of Fire

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

Fire Suppression Solutions

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Fire suppression systems for server rooms and data centres

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Carbon Dioxide Fire Suppression Systems

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Typical Applications: Excavators Haul Trucks Wheeled Loaders Drag Lines Large Dozers Drills

Fire Suppression Systems. Heavy Duty Mobile Plant Protecting Your Business. Head Office: 14 Baynes Place, Chelmsford, Essex, CM1 2QX

Types of Detection. Fusible Link Detection - Most Common

APPUZO RANGE HOOD INSTALLATION

SUPERIOR THINKING. DEEPER DIGGING. Underground Mining Fire Suppression Systems

ODS & SGG Alternatives for the Fire Protection Industry 2018

THE BIGGEST, SMALLEST FIREFIGHTER. CEASEFIRE MINI. Suppression System

Data/ Specification Sheet

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Chapter 10: Laboratory Equipment

Propane Flame Projector Safety instructions and operating manual

Emergency Operating Procedures for: Fire and Emergency

STEPP SRM 10x120(Asphalt Recycler) SPECIFICATIONS. SRM 10x120 Self Loading

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

SECTION AUXILIARY HEATER

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

Element 14.7 Fire Prevention and Control 2018

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

CO2 COCO GAS FLOODING SYSTEM

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

THE IDEAL SOLUTION FOR KITCHENS

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Reflex fire detection and extinguishing system filled with ABC dry powder. Installation, operation and maintenance instructions

Osceola County Department of Fire Rescue and Emergency Medical Services

Kiddie After Discharge Clean-Up

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

Laboratory Equipment. Section 1L. Chemistry I & II

Fire Protection for Cable Tunnels

CO 2 Fire Extinguishing Systems

Fixed plant and mobile equipment fires on surface coal mines

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

How can you minimize consequential damages in case of a fire?

Reflex fire detection and extinguishing system charged with Novec 1230 extinguishing agent. Installation, operation and maintenance instructions

Workplace FIRE SAFETY

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

Inert Gas Fire Extinguishing System

3gb53231b.fm5 Page 12 Friday, April 11, :21 PM

Safety In Chemistry. Identified Risks and Hazards

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

Explosion Protection Engineering Principles

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

EM-3.1 SAFETY ALERT HEAVY EQUIPMENT VEHICLE FIRES AND SUPPRESSION SYSTEMS

and Refrigerant Identifier

A Chiller is equipment to control temperature of customers heating sources. Application Examples

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

Twin-Agent Fire Fighting/Securing Systems Specifications

CORE Protection Fire System Specification

FIRE SAFETY. Department of Chemical Engineering College of Engineering

Contractor Worksheet Underground Fires Major Hazard Standard

1. GENERAL SAFETY RULES

Basic Vehicle Fire Protection Manual

LFL Series Burner Flame Safeguard Control

SNUGGER SNUGGER AIR HEATER AIR SNUGGER USA Technical description. Installation instructions. Operating instructions

Transcription:

FIREDETEC

TECHNOLOGY: DIRECT & INDIRECT PROPERTIES DIRECT SYSTEM (< 1m 3 ) DETECTION TUBE : FIRE DETECTION & EXTINGUISHING AGENT DISCHARGE IDEAL APPLICATION: Small and hard to reach enclosures (< 1m 3 ) BEST PRICE PERFOMANCE VERY EASY TO INSTALL PROPERTIES INDIRECT SYSTEM (< 9m 3 ) DETECTION TUBE : FIRE DETECTION ONLY DISCHARGE THROUGH A SEPARATE DISCHARGE LINE MOST EFFECTIVE PERFORMANCE QUICKER DISCHARGE MANUAL ACTUATION POSSIBLE Only indirect systems can be UL or FM approved

SYSTEM CONSTRUCTION CYLINDER/VALVE ASSEMBLY Cylinder Valve Siphon Tube Mounting bracket Ball Valve Valve End of Line Device Discharge tube DETECTION SUB-SYSTEM Detection Tubing End of line device Mounting clips Cylinder Nozzle Detection Tubing DISCHARGE SUB-SYSTEM Nozzle Discharge Tubing Fittings Flexible Hose Mounting clips

TUBING TECHNOLOGY FIREDETEC TUBING SPECIFICITIES Dual-function: detects and suppresses (direct systems) Compact, flexible and reliable Burst temperature: 110 C or 175 C Linear pneumatic detection: no external power source Can be installed anywhere even in hard-to-reach places Advanced technology polymer construction: Resistant to severe environments, UV, and extreme temperatures Originally developed by Rotarex

TUBING TECHNOLOGY 1 INSTALLS INSIDE EQUIPMENT CLOSER TO THE SOURCE. Compact and Flexible Installs almost anywhere Even in hard to reach spaces Just cm from critical circuitry and mechanics 2 QUICKLY DETECTS AND SUPPRESSES FIRES The tube is pressurized to 16 bar It bursts at 110 C or 175 C at early sign of fire The drop in pressure instantly actuates the valve Extinguishing agent floods the compartment The fire is suppressed in just seconds

CREATE YOUR OWN SYSTEM CYLINDER VALVE HFC-227 CYLINDER VALVE NOVEC 1230 CYLINDER VALVE CO 2 CYLINDER VALVE ABC Dry chemical CYLINDER VALVE FireDETEC F/K CYLINDER VALVE FireDETEC TS55

ADVANTAGES Efficiency Excellent value/price ratio Continuous linear detection Quick reaction time Works 24/7 High-quality & Reliability Certifications from both independent and governmental agencies No accidental discharge Ability to detection of leak Shock and vibration resistant Flexibility Installation on almost every type of applications Installation even in hard to access spaces No external power source needed High & low pressure systems available Easy installation & maintenance Quick installation Simple maintenance steps Environment: Low environmental impact

FIREDETEC DEMONSTRATION

MAIN MARKETS HOSPITALS Electrical Equipment Laboratories Emergency Generators Elevators PORTS AND SHIPPING TERMINALS Reach stackers Elevator Trucks Mobile Cranes Cargo Cranes AIRPORTS Server rooms Radar and control tower equipment Escalators and moving walkways Baggage handling equipment ; de-icing trucks ; fueling trucks MINES Heavy equipment (Bulldozers ; front end loaders ; conveyor systems ) Mobile equipment (Extraction machines ; drilling machines ) Electrical panels INDUSTRY (MACHINE SHOPS + FACTORY) CNC Machines EDM Machines Electrical cabinets Dust extractors WINDMILLS Control Cabinet Hydraulic Station Transformer Braking system Condenser PUBLIC TRANSPORTS Bus vehicle engine Electrical cabinets in metro stations Trains PHARMACEUTICAL & ANALYTICAL LABS Fume Hoods Flammable liquid storage closets Air filtration systems Exhaust systems

APPLICATIONS EXAMPLE ELECTRICAL CABINET Multiple causes of fire: Short-circuits, overloading or overheating of components Formation of intermittent arcs Incorrect installation Faulty equipment (electrical malfunction ; lifetime of equipment ) Available extinguishing agent: CO2 HFC-227 / NOVEC Certifications: FM / UL approval for DOT cylinders (HFC-227 / NOVEC)

APPLICATIONS EXAMPLE INDUSTRIAL MACHINERY Multiple causes of fire: Combustion of oil residues and flammable metals Malfunction (coolant system ; tool breakage ; low maintenance) High friction (static electricity) Human behavior : operator error Available extinguishing agent: CO2

APPLICATIONS EXAMPLE LABORATORY FUME HOOD Multiple causes of fire: Ignition of chemical residues and vapors in the extractor Open flame (Bunsen burner) ; heating plates Volatile and reactive agents Human behavior: technician error Available extinguishing agent: CO2 HFC-227 / NOVEC ABC dry chemical Certifications: FM / UL approval for DOT cylinders (HFC-227 / NOVEC)

APPLICATIONS EXAMPLE COMMERCIAL KITCHEN Multiple causes of fire: Grease Flammable oils Open flames/heat Available extinguishing agent: F/K extinguishing agent Certifications: LPCB

APPLICATIONS EXAMPLE VEHICLE ENGINE Multiple causes of fire: Temperature of engine compartment Little maintenance time Available extinguishing agent: TS-55 extinguishing agent BerkiCold Certifications: SPCR 183

SPECIAL FEATURES Functioning: DIMES Measurement of CO2 contents Capacitance difference between two electrodes. Detection of changes in the mass of CO2 (liquid and gas phases) ADVANTAGES Real-time measurement Temperature compensation Very precise Reduced maintenance costs (Eliminates need to dismount and weigh cylinders) Personal alarm level setting Multiple cylinder controlling Easy installation (system integrated into the valve body) Easy calibration Note: only available with IHP Valves (B0702) and Electromagnetic valve (B0439)

SPECIAL FEATURES DIRECTIONAL VALVES Advantages: Protection of several enclosures with only one cylinder Detection and discharge only in the zone with fire

THANK YOU FOR YOUR ATTENTION