Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Similar documents
Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Temperature controller type KTR96EX PTB 97 ATEX 1031 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

PEPPERL+FUCHS GmbH

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

VERSAFLOW VORTEX Supplementary instructions

Technical Data. Dimensions

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Technical Data. Dimensions

Electrical Installations Design, Selection, Erection and Inspection

Operating Instructions

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

OPTIBAR DP 7060 Supplementary Instructions

Technical Data. Dimensions

Technical Data. Dimensions

Explosion-proof Immersion Heater Type D-8660

OPTIBAR P 1010/2010 C Supplementary instructions

Translation of the assembly instructions with operating instructions and technical appendix

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Earth-Rite II PLUS Static Earthing System

INSTRUCTION MANUAL (ATEX / IECEx)

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Operating Manual Distribution box

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Multipoint temperature sensor

User Information Sheet 008 : 2010

MANUAL Oil Level Sensor

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

IECEx Certificate of Conformity

Flameproof Manual Call Points

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Manual Power relay SR853

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

Exp, pressurized systems

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Explosion Protection Enclosure with integrated measuring system

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

Survey of electrical equipment installed in hazardous areas on tankers

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

RFM Series RFM-ISR Barrier. Installation Manual

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

MANUAL Overflow sensor NVF-104/34-PF

GENERAL SPECIFICATION ELECTRICAL

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

BKA-EN Fire Damper. Additional operating instructions according to

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

Operating Manual MS220DA

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Manual for QX0201 Push Button

BSK-RPR Fire Damper. Additional operating instructions according to

INTERNATIONAL STANDARD

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Technical Data. General specifications. Rated operating distance s n 5 mm

Installation, Operating and Servicing Instructions. Lynx 400 Heavy-Duty Contact Grill GG1, GG1R, GG1P

Overload Relay EMT6 Overload monitoring system for machines operating in the EEx e area

Operating Manual MS220KA and MSR220KA

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Explosion-protected actuator Page 259 of 292

4) Intrinsic Safety Certification

SITRANS. Temperature sensors SITRANS TSinsert/TS100/TS200/ TS500. Introduction 1. Safety information 2. Description 3. Installation 4.

Certification Supplement Manual


Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

ExPolar Heating System

manual addendum DELPHI Ex

polar zone components and systems for extreme temperatures

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

IECEx Certificate of Conformity

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

QFM21... Duct sensors. Symaro. for relative humidity and temperature

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Documentation. Parallel Heating Cable. Type: ELP

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

Transcription:

Immersion heating type IN 16.. PTB 99 ATEX 1009 U May 1999 thuba Ltd. CH-4015 Basle Telefon +41 061 307 80 00 Telefax + 41 061 307 80 00 headoffice@thuba.com www.thuba.com

Manual PTB 99 ATEX 1009U 2 Immersion Heater Type IN 16.. Target group: Experienced electricians as defined by ElexV and properly instructed personnel. Contents: 1. Safety rules 2. Conformity with standards 3. Technical data 4. Installation 5. Maintenance 1. Safety rules The immersion heater is used for heating liquids and gas/air mixtures. The immersion heater may be used only for heating combustible and noncombustible liquids with a flash point 55 C in open systems that are not heated above their flash point. It is not suitable for use in Zone 0. The immersion heater is designed for attachment to vessels, apparatus and piping systems by means of a flange connection. The safety precautions taken for the heating of closed systems must be reviewed by an expert. During operation, do not leave this instruction Manual or other objects in the junction box. Operate the immersion heater for its intended duty in undamaged and clean condition, and only where the resistance of the enclosure material to the ambient conditions is assured. The junction box s minimum protection of IP 54 applies only in the case of correct assembly in compliance with EN 60 529: 1991. No modifications to the immersion heater are allowed. The manufacturer has adapted the immersion heater to the specific requirements during project planning and/or has established the temperature class and other duty conditions by routine thermal testing prior to initial start-up taking local and

Manual PTB 99 ATEX 1009U 3 operating circumstances into account; the temperature class and other duty conditions may not be changed thereafter. The manufacturer has designed the control system as an integral part of the immersion heater installation in terms of safety and type aspects in accordance with EN 50 019:1994. The heating of liquids is permissible only if there is sufficient cover ( 50 mm). This requirement can be fulfilled with a level detector or comparable precautionary measures. In the case of installations with flowing liquids, the flow monitor provided is an integral part of the installation. Modifications to it are also forbidden. Whenever work is done on the immersion heater installation, be sure to observe the national safety and accident prevention codes as well as the safety rules that follow in this Instruction Manual, which are stated in italics like this paragraph! 2. Conformity with standards The immersion heater complies with the requirements of EN 50 014:1997, EN 50 018: 1995 and EN 50 019:1996. It was developed, manufactured and tested in accordance with state-ofthe-art engineering practice and EN 29 001. 3. Technical data Explosion protection EEx de IIC T1...T6 EC Type Test Certificate PTB 99 ATEX 1009U Junction box enclosure material stainless steel or polyester, depending on the version Enclosure protection type IP 54 (to IEC Publication 529) Admissible ambient temperatures 20 C to +40 C

Manual PTB 99 ATEX 1009U 4 Marking 0102 II 2 G 3.1 Electrical data Maximum figures for the power circuits: Rated voltage e.g. max. 750 V (see rating plate) Rated current e.g. max. 63 A (depending on version) Max. conductor cross-section e.g. 16 mm² (depending on version) Maximum figures for the control circuits: Rated voltage e.g. max. 250 V (see rating plate) Rated current e.g. max. 16 A (depending on version) Max. conductor cross-section e.g. 2.5 mm² (depending on version Type code IN 16.. Heating rod diameter 08 8.5 mm 10 10 mm 12 12.8 mm 14 14 mm 16 16 mm 63 63 mm

Manual PTB 99 ATEX 1009U 5 4. Installation For installation/operation, the provisions of ElexV and the Equipment Safety Law apply, as do generally accepted engineering practice (EN 60079-14) and this Instruction Manual. The immersion heater is designed for attachment to vessels, apparatus and piping systems by means of a flange connection only. It is inadmissible to undertake modifications to the operation of the immersion heater. Only the manufacturer may carry out such modifications. A wiring diagram is provided with every immersion heater. It provides information on utilization of the junction box terminals by the power and control circuits and should be observed without fail. Be sure to observe the figures stated on the rating plate and any other information provided by the manufacturer. Supplementary documentation from the manufacturer should be observed and taken into account whenever changes are made (e.g. replacement of a control contactor). The cable and conductor entry glands in the junction box are made of plastic or metal. Take care to bring in the cables and conductors through these glands in such a way that selfloosening will be prevented and permanent sealing of these cable and conductor entry glands is assured. Depending on the heater version, the conductor cross-sections are carried to the respective terminals as indicated in the wiring diagram. 4.1 Temperature The temperature class is established during the type testing or during the thermal testing that takes local and operating conditions into account and is subject to approval by an expert. It is absolutely necessary to observe the maximum ambient temperature. In this connection, take nearby sources of heat into account in order to ensure safe operation of the control and monitoring equipment. The connection head of any immersion heater is subject to temperature limitations. Use the heater only for its intended

Manual PTB 99 ATEX 1009U 6 purpose, and do not exceed the maximum admissible temperature. At the same time, make sure that the heat from the connection head can be dissipated unhindered. The thermostat reset elements in the junction box may be actuated only after the cause of tripping has been rectified and normal operating conditions have been restored. Prior to initial start-up and during operation, make sure that the parts of the immersion heater in contact with the medium are fully covered by liquid. They should be covered by no less than 50 mm of liquid at all times. 4.2 Equipotential bonding The internal and external potential terminals are provided for reliable connection of the equipotential bonding conductor. They are laid out for a maximum connection cross-section of 16 mm² (depending on the version). 5. Maintenance The provisions of ElexV 9, ElexV 13 and EN 60079-17 applicable to maintenance/overhaul/testing must be observed. When performing maintenance work, pay special attention to checking those parts that govern the equipment s type of protection.