Engine Block Heater Service Kits (Tank Type) ROZJ 6076T and 6076A (John Deere Powered Standby Generator Sets)

Similar documents
Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

CABS/BLADES/ SPREADERS/ACCESSORIES

DRAIN WATER TEMPERING INSTALL

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

A HEATER KIT With Diesel Engine Connection Fittings

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

DRAIN WATER TEMPERING INSTALL

V-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17)

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

How to Install a Mishimoto Radiator for a Mustang 5.0L

Heater with Air Conditioning. E-Series Ford Aeromaster

SAN JUAN FRESH WATER COOLING SYSTEMS

Kawasaki Teryx Firestorm Heater Kit Instructions.

MOUNTING INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

MOUNTING INSTRUCTIONS

Owner's Manual. WS Series. Water Softener

JOHN DEERE X465, X475, X485, X495, X575, X585

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

ENGINE COOLING 14-1 CONTENTS THERMOSTAT... 3 SERVICE SPECIFICATIONS... 2 LUBRICANT... 2 WATER PUMP... 5 ON-VEHICLE SERVICE... 2

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

Can Am Commander 1000 Radiator Relocation Installation Instructions

SECTION 1D ENGINE COOLING

Product Support Bulletin

INSTALLATION INSTRUCTIONS

APW PSI PRESSURE WASHER

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST FORD TRUCK

A B A B4

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Parts and Service Manual

INSTALLATION INSTRUCTIONS

Cool IR. Model C104 - Cooling System. Instruction Manual

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

READ AND SAVE THESE INSTRUCTIONS

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

Installation Instructions

SuperKlean Washdown Products

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

Installation Instructions. Instructions de montage. Instrucciones de instalación HC

BURWELL BIDET TOILET SEAT INSTALLATION

7165 Dust Collector Owner s Manual

Installation Instructions

FIREPLACE INSTALLATION

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

D400A/W Ice Machine. Installation Manual. D400A ice machine. D400W ice machine. Order parts online.

SM Field Installed Electric Heat Kit

Fountain Classic. Installation and Owner s Manual. Page 16

Removal. CAUTION: Do not let tensioner arm snap back to the freearm position, sever damage may occur to the tensioner.

Installation Instructions

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Service Bulletin Trucks Date Number Page

INSTALLATION INSTRUCTIONS

6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500

Heaters and Defrosters

INSTALLATION INSTRUCTIONS

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

This site is based on a but applies to all 1971-on Saab 99 and Saab 900.

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

P/N CC-100. Coolant Circulator. Operation manual

Chapter 3 Cooling, heating and ventilation systems

BC BRONCOS AIR CONDITIONING UNIT

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

690 and Power Fishing Systems

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

Installation Instructions

Models: GW/R-T GW/R-2-T GW/R-3-T

BMW E36 Thermostat Removal And Coolant Flush

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

ENGLISH USER S GUIDE ThermoCar from 0,5 to 2 kw

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

INSTALLATION INSTRUCTIONS

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST EARLY 1955 CHEVROLET PICKUP

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

A I FAN ASSEMBLY KIT FOR SERIES 3860 AND 3890 DESCRIPTION

INSTALLATION INSTRUCTIONS

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

General System Layout Sketch

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames

ignored. Denotes content that may result in bodily injury and physical damage when ignored.

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS:

Transcription:

TT 760 INSTRUCTIONS 8/91 Engine Block Heater Service Kits (Tank Type) 125 180ROZJ 6076T and 6076A (John Deere Powered Standby Generator Sets) Model Voltage Kit No. 125 150ROZJ 120 276511 125 150ROZJ 240 276512 150* 180ROZJ 120 276513 150* 180ROZJ 240 276514 *Oversized Generator Set This service kit details removal of the immersion type block heater (or earlier version tank type block heater) and installation of a new tank type block heater kit. These instructions cover the installation of several block heater kits. In instances where two different part numbers are mentioned, refer to Figure 3 to determine which part number applies to your application. The engine block heater kit (tank type) heats engine coolant, making starting easier and warm up quicker. The thermostat will automatically turn off when coolant temperature reaches 120 F (49 C). CAUTION Engine block heater can cause electrical shock. Remove engine block heater plug from electrical outlet before working on block heater electrical connections. Block heater will fail if not immersed in water. Always unplug block heater(s) before draining coolant and fill engine block with coolant prior to plugging in block heater(s). Block heater element MUST be immersed in engine coolant before being energized. WARNING Accidental starting can cause death or serious personal injury. Turn Generator Master Switch to OFF position, disconnect power to battery charger, and remove battery cables (remove negative lead first and reconnect it last) to disable generator set before working on any equipment connected to generator. The generator set can be started by automatic transfer switch or remote start/stop switch unless these precautions are followed. WARNING Hot coolant can cause severe burns. Allow engine to cool and release pressure from cooling system before opening pressure cap. To release pressure, cover the pressure cap with a thick cloth then turn it slowly counterclockwise to the first stop. After pressure has been completely released and the engine has cooled, remove cap. If generator set is equipped with a coolant recovery tank, check coolant level at tank.

153659 Reducing Bushing Location of Thermostat Block Heater X 75 22 Pipe Plug Location BF 273000 Figure 1. Block Heater Kit Removal (Immersion Type) DH 273000 PARTS IDENTIFIED WILL NOT BE RE USED. 276209 (Kits 276511 & 276513) 276208 (Kits 276512 & 276514) X 577 10 (6 hose) X 426 10 (2) Hose clamps Former Thermostat Location X 577 35 (30 ) or X 577 41 (33 ) Hose, and X 426 10 (2) Hose clamps Figure 2. Block Heater Kit Removal (Early Version Tank Type)

VIEW A A DH 273000 Pipe Plug Location Thermostat X 202 41 Thermostat Location Kits 276511 & 276512 X 577 42 X 426 10 (2) Kits 276513 & 276514 X 577 40 X 426 10 (2) X 672 3 X 6024 5 X 25 34 VIEW B B Route wire through clamp and tie to block heater hose with cable ties provided in kit. Eng. Mtg. Foot SA 472 X 582 3 Note; Rotate fittings so hose is directed towards block heater. 275582 250081 (2) B 276691 (Kits 276511 & 276513) 276692 (Kits 276512 & 276514) 275583 X 465 7 (4) X 25 40 (4) X 20 1 (4) X 81 1 (4) Figure 3. Block Heater Installation B Kits 276511 & 276512: X 577 36 & X 426 10 (2) Kits 276513 & 276514: X 577 42 & X 426 10 (2) 279047

Installation 1. Move controller master switch to OFF position. Disconnect battery of generator set, negative lead first. Disconnect power from existing block heater. 2. With generator set sufficiently cooled, drain the coolant into a suitable container. Dispose of used engine coolant in an environmentally safe manner. Take used coolant to a suitable collection facility in your area. Do not pour used coolant on the ground, down sewers, or into streams and other bodies of water. Drain valve is located on radiator bottom and/or side of engine crankcase. If set is already installed with a tank type heater (as shown in Figure 2) proceed to Step #8. However, if component parts show wear or are damaged in some way, then replace with parts supplied in kit and follow all instructions provided. 3. Remove electrical connections to block heater and thermostat. Discard electrical connections. These parts will not be reused. See Figure 1. 4. Remove immersion type block heater from engine block and discard. These parts will not be reused. Clean threads on engine and apply pipe sealant to 1 in. pipe plug (X 75 22) and install into block. See Figure 1. Apply pipe sealant to male threads of all components when assembling. 5. Remove thermostat and reducing bushing (153659) and discard. These items will not be reused. Attach elbow (SA 472) and hose connector (X 582 3). See Figures 1 & 3. Rotate fittings so hose is directed towards block heater. 6. Locate hose clamp (X 426 10) 1/4 in. (6 mm) from end of hose (X 577 42 or X 577 40) and tighten to hose connector mentioned in Step 5. 7. Attach mounting bracket (275583) to skid using mounting hardware supplied. 8. Install block heater (276691 or 276692) to mounting bracket. (If installing on unit with tank type heater, remove existing block heater, discard, and replace with new block heater supplied in kit.) Locate hose clamp (X 426 10) 1/4 in. (6 mm) from end of hose (X 577 42 or X 577 40) and tighten to block heater outlet. If set is already installed with a tank type block heater, follow Step #9, otherwise proceed to Step #11. 9. Remove and discard 6 hose (X 577 10) and two hose clamps (X 426 10). See Figure 2. 10. Remove and discard 30 hose (X 577 35) or 33 hose (X 577 41) and two hose clamps (X 426 10). See Figure 2. 11. Connect hose (X 577 36 or X 577 42) to block heater inlet and secure with hose clamp (X 426 10). 12. Position thermostat at location shown in Figure 3 (view A A), by first installing reducer bushing (X 202 41). Route wire through clamp (X 672 3). Install insulator clamp (X 672 3) using washer (X 25 34) and screw (X 6024 5). Tie wire to block heater hose with cable ties provided in kit. See Figure 1, view B B. If set is already installed with a tank type block heater, proceed to Step #15. 13. Locate lower radiator hose and mark hose at 5 in. (127 mm) and 6 in. (152 mm) from radiator outlet. Cut at these marks to remove 1 in. (25 mm) from hose. 14. Place two large hose clamps (250081) on cut radiator hose (one on each end). Install hose

connector (275582) with nipple pointing downward. 15. Locate hose clamp (X 426 10) 1/4 in. (6 mm) from end of hose (X 577 36 or X 577 42) and tighten to nipple on hose connector. Remote City Standard Radiator Water Model Radiator 60HZ 50HZ Cooled 125ROZJ 7.5 (24) 11.8 (44.7) 12.8 (48.4) 5.05 (19.1) 150ROZJ 7.8 (25) 12 (45.4) 13 (49.2) 5.25 (19.9) 180ROZJ 7.8 (25) 13 (49.2) 15 (56.8) 6 (22.7) : Capacities shown may vary from model to model and are subject to change. Table 1. Coolant Capacities U.S. Gal. (L) 16. Use cable ties, as necessary, to protect and secure wiring from sharp objects, exhaust system, and any moving parts. 17. Close petcock valves on radiator and/or engine block. 18. Fill cooling system to proper level with fresh coolant. A solution of 50% ethylene glycol and 50% clean, softened water is recommended to inhibit rust/corrosion and provide freezing protection. See Table 1 for coolant capacities. Coolant mixtures exceeding 50% ethylene glycol may cause block heater element failure. 19. Check that the controller master switch is in the OFF position. Reconnect battery, negative lead last. 20. Test run generator set for a few minutes and check for leaks. Stop generator set and after set has cooled check coolant level. Special attention should be given when checking for proper coolant level. After a radiator has been drained, it normally requires some time before complete refill of all air cavities takes place. 21. Connect block heater electrical plug to proper voltage outlet. Tie tag (279047) to electrical cord coming from block heater. Parts Listing Common Kit Numbers Qty Description Parts 276511 276512 276513 276514 1 Elbow SA 472 4 Washer, Lock 1/4 X 20 1 4 Washer,Plain 9/32 x 5/8 x.05 X 25 40 4 Clamp, Hose (max. range 1.00) X 426 10 4 Screw, H.C. 1/4 20 x 1 X 465 7 1 Hose 37 X 577 36 X 577 36 1 Hose 45 X 577 40 X 577 40 1 Hose 40 X 577 42 1 Connector, Adapter Hose X 582 3 1 Plug, Pipe 1 X 75 22 4 Nut, Hex. 1/4 20 X 81 1 2 Clamp, Hose (max. range 3.00) 250081 1 Connector, Hose 275582 1 Bracket, Mounting 275583 1 Heater, Block 276691 276692 276691 276692 1 Tag, Hang 279047 1 Bushing, Reducer X 202 41 1 Washer, Plain 15/32 x 59/64 x.06 X 25 34 1 Screw, H.C. 7/16 14 x 3/4 X 6024 5 1 Clamp, Insulating X 672 3

S

S

S